Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Coron Artery Dis ; 11(7): 549-54, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11023243

RESUMO

BACKGROUND: A major limitation of stress echocardiography remains poor image quality. OBJECTIVE: To investigate the effects of transpulmonary contrast echocardiography (TCE) with BY 963 on endocardial border delineation, detectability of wall motion abnormalities and interobserver variability at rest and during dobutamine stress echocardiography (DSE) in subjects with technically limited baseline echocardiograms. METHODS: BY 963 was administered intravenously to 36 patients (5 ml for parasternal LAX/SAX, 10 ml for apical four-chamber/two-chamber view) both at rest and at peak stress during DSE. Two observers applied a delineation score (0, endocardial border not visible; 1 border poorly visible; and 2, border clearly visible) to 12 wall segments in the parasternal and 10 in the apical views both before and after administration of BY 963. A 16-segment wall-motion score was used. RESULTS: In parasternal views, the delineation score was not improved by TCE. In the apical views, TCE significantly increased the delineation score (from 14.1 +/- 5.4 to 20.7 +/- 4.2 at rest and from 14.6 +/- 5.7 to 21.7 +/- 4.1 under stress, both P< 0.01). For 18 of 25 patients with coronary artery disease (> or = 70% stenosis) results of DSE were positive before TCE, whereas results were positive for 21 patients during TCE. For 10 of 11 patients without coronary artery disease, results of DSE were negative both before and during TCE. For the apical delineation score, interobserver variability was decreased significantly by TCE (from 19.5 +/- 19.6 to 8.2 +/- 15.6% at rest and from 20.2 +/- 19.6 to 3.3 +/- 11.4% at peak stress, both P< 0.01). CONCLUSIONS: TCE enhances endocardial border delineation in apical views at rest and during DSE, resulting in a decrease of interobserver variability and an improvement in assessment of wall motion. Use of TCE, at least how it was applied in this investigation, seems not to be indicated for parasternal projections.


Assuntos
Meios de Contraste , Doença das Coronárias/diagnóstico por imagem , Ecocardiografia/métodos , Endocárdio/diagnóstico por imagem , Fosfatidilcolinas , Cardiotônicos , Angiografia Coronária , Doença das Coronárias/patologia , Dobutamina , Endocárdio/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Variações Dependentes do Observador , Reprodutibilidade dos Testes
2.
Z Kardiol ; 89 Suppl 9: IX/50-3, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11151793

RESUMO

Invasive methods as coronary angiography and intravascular ultrasound (IVUS) are still the routine tools for diagnosis of cardiac allograft vasculopathy (CAV). Nevertheless, invasive tests are expensive and not free of risk. Dobutamine stress echocardiography (DSE) emerged as a useful noninvasive tool for assessment of cardiac allograft vasculopathy (CAV). In our study, echocardiographic wall motion abnormalities (WMA) at rest had a sensitivity of 57% (specificity 88%) to detect CAV defined by IVUS and angiography, which was significantly (p < 0.0001) improved to 72% (specificity 88%) by stress testing. Additional M-mode analysis of systolic wall thickening improved the sensitivity of the resting echocardiogram to 72% (specificity 85%), the combined M-mode and 2D-analysis during stress had a sensitivity of 85% (p < 0.0001; specificity 82%). DSE was also useful to predict prognosis: 1.9% of patients with normal, but 27.3% of patients with abnormal 2D-DSE developed cardiac events (heart failure, infarction, death, re-HTX, PTCA) between annual studies (p < 0.0002). No change in serial DSE studies was associated with a low event rate (4%), compared to serial DSE deterioration (29%, p < 0.0014). Based on our experience, we postpone invasive studies for 12-24 months, if DSE is normal or remains unchanged in serial studies. Angiography is used in patients with abnormal or deteriorating DSE. In conclusion, noninvasive DSE provides useful diagnostic and prognostic information. It appears safe to use DSE as a first step of CAV monitoring.


Assuntos
Agonistas Adrenérgicos beta , Cardiotônicos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etiologia , Dobutamina , Ecocardiografia/métodos , Transplante de Coração/efeitos adversos , Doença Aguda , Adulto , Criança , Angiografia Coronária , Seguimentos , Rejeição de Enxerto/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Prognóstico , Risco , Fatores de Risco , Sensibilidade e Especificidade , Fatores de Tempo , Ultrassonografia de Intervenção
3.
Transplantation ; 68(10): 1477-81, 1999 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-10589942

RESUMO

BACKGROUND: Determination of coronary flow reserve (CFR) is increasingly used to assess the functional significance of cardiac allograft vasculopathy. Although the relation between CFR and angiographically defined vasculopathy has been studied extensively, little is known about other factors determining CFR in heart transplant recipients without significant lesions by coronary angiography. METHODS: Sixty consecutive patients were studied 0.5 to 148 months after heart transplantation with intracoronary Doppler and intravascular ultrasound. An endothelium-independent CFR< or =2.5 was defined as abnormal. Stepwise logistic regression analysis was used to identify factors (demographic data of donor and recipient, lipid profile, epicardial vessel morphology by intravascular ultrasound, left ventricular hypertrophy, acute rejection episodes, and hemodynamics) potentially associated with a reduced CFR. RESULTS: Only the presence of left ventricular hypertrophy (48% vs. 14%, P=0.007 and P=0.023, bivariate and multivariate analysis, respectively) and higher donor ages (41+/-12 vs. 29+/-11 years, P=0.002 and P=0.013, bivariate and multivariate analysis, respectively) showed an independent association with an abnormal flow reserve. CFR in patients with left ventricular hypertrophy was reduced due to higher baseline flow velocities (27+/-11 vs. 20+/-6 cm/sec, P=0.004). Furthermore, resting flow velocity increased as a function of donor age (r=0.264, P=0.047), while hyperemic flow velocity was not different. Other patient characteristics and hemodynamics did not affect CFR. CONCLUSION: The presence of left ventricular hypertrophy and higher donor ages independently contribute to a reduced CFR in patients after heart transplantation. This reduction in CFR is due to elevated baseline flow velocities rather than to a change in hyperemic flow velocities. These findings should be taken into account for the interpretation of reduced CFR values obtained by intracoronary Doppler in heart transplant recipients without angiographically overt coronary lesions.


Assuntos
Circulação Coronária/fisiologia , Doença das Coronárias/fisiopatologia , Transplante de Coração/fisiologia , Adulto , Fatores Etários , Pressão Sanguínea , Colesterol/sangue , Doença das Coronárias/diagnóstico por imagem , Feminino , Seguimentos , Hemodinâmica , Humanos , Hipertrofia Ventricular Esquerda/fisiopatologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Complicações Pós-Operatórias , Radiografia , Análise de Regressão , Medição de Risco , Doadores de Tecidos , Triglicerídeos/sangue , Ultrassonografia
4.
Z Kardiol ; 88(9): 615-21, 1999 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-10525922

RESUMO

UNLABELLED: Stress echocardiography has been shown to be a valuable noninvasive method for the diagnosis of restenosis after coronary angioplasty. To determine the usefulness of dobutamine stress echocardiography (DSE) for assessment of restenosis after intracoronary stent implantation, we studied 50 patients (59+/-10 years; 1-vessel disease, n=16; multivessel disease, n=34) after stent implantation. After 6 month, both DSE (5-40 mcg/kg/min, 0-1mg atropine) and angiography were performed within 48 hours and evaluated in a blinded fashion. Restenosis was defined by quantitative coronary angiography as minimal lumen diameter (LD) <50% of average reference LD. Diagnostic criteria of DSE were new or worsening wall motion abnormalities in corresponding perfusion territories during stress. Angiography revealed restenosis in 8 patients; one patient had a denovostenosis distal to the stented segment (8 x left anterior descending artery, 1 ACVB to the right coronary artery). In 6 of these 9 patients, DSE was positive (mean reduction of LD 88+/-7%; sensitivity 67%), in 3 patients negative (mean reduction of LD 62+/-7%, 1 x termination of DSE because of wall motion abnormalities in an area not supplied by the stented vessel). In 38 of 41 patients without restenosis, DSE showed no stress-induced wall motion abnormalities in the LV area supplied by the stented vessel (specificity 93%). CONCLUSIONS: DSE is a useful noninvasive method for detecting restenosis after intracoronary stent implantation. With negative DSE at follow-up, a functionally relevant stent restenosis is highly unlikely.


Assuntos
Angioplastia Coronária com Balão , Cardiotônicos , Doença das Coronárias/diagnóstico , Dobutamina , Eletrocardiografia , Teste de Esforço , Stents , Adulto , Idoso , Angiografia Coronária , Doença das Coronárias/terapia , Eletrocardiografia/efeitos dos fármacos , Teste de Esforço/efeitos dos fármacos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento
5.
J Heart Lung Transplant ; 18(9): 904-12, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10528753

RESUMO

BACKGROUND: There are no well-established diagnostic criteria to detect humoral rejection in organ transplantation. The value of commonly used markers in immunohistochemistry, such as C1q, C3c, IgG, IgM and fibrinogen, is questioned by some groups. Complement fragment C4d is a more stable marker of complement activation as it is covalently bound to graft capillaries. C4d has been shown to identify clinically relevant, but otherwise undetectable humoral anti-graft reactions in human kidney transplants. METHODS: Immunohistochemical techniques were used to evaluate 155 endomyocardial biopsies from 56 heart transplant recipients less than 3 months post transplantation for the presence of capillary C4d staining. In a subset of patients, C4d staining was compared with C1q, C3c, IgM and fibrin staining and was correlated with clinical outcome. RESULTS: Within 3 months 9 of 56 patients died. Five of these nonsurvivors had prominent C4d staining (p < .05), whereas C1q, C3c and IgM showed no correlation with clinical outcome. Presence of fibrin correlated with clinical outcome and C4d staining (p < .05). CONCLUSIONS: The capillary deposition of complement split product C4d in human endomyocardial biopsies was significantly associated with graft loss. Determination of fibrin deposition may yield additional information to establish a diagnosis of humoral rejection. The immunohistochemical assessment of capillary deposition of C4d and fibrin appears to be an appropriate tool for the identification of patients, who may require additional or alternative immunosuppressive therapy targeted against the humoral immune system.


Assuntos
Capilares/imunologia , Complemento C4/análise , Complemento C4b , Endocárdio/imunologia , Rejeição de Enxerto/imunologia , Transplante de Coração/imunologia , Miocárdio/imunologia , Fragmentos de Peptídeos/análise , Adulto , Biópsia por Agulha , Capilares/química , Complemento C1q/análise , Complemento C3c/análise , Vasos Coronários/química , Vasos Coronários/imunologia , Fibrina/análise , Rejeição de Enxerto/diagnóstico , Humanos , Imunoglobulina M/análise , Imuno-Histoquímica , Pessoa de Meia-Idade , Fatores de Risco
6.
Circulation ; 100(5): 509-15, 1999 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-10430765

RESUMO

BACKGROUND: Routine methods for surveillance of cardiac allograft vasculopathy (CAV) are coronary angiography and intravascular ultrasound (IVUS). This study analyzed the diagnostic and prognostic value of dobutamine stress echocardiography (DSE) for noninvasive assessment of CAV. METHODS AND RESULTS: In 109 heart transplant recipients, 333 DSEs were compared with 285 coronary angiograms and 199 IVUS analyses. Studies were repeated after 1, 2, 3, 4, and >/=5 years in 88, 74, 37, 18, and 7 patients, respectively. Resting 2D echocardiography detected CAV defined by IVUS and angiography with a sensitivity of 57% (specificity 88%). DSE increased the sensitivity to 72% (P=0.002). M-mode analysis increased the sensitivity of 2D rest and stress analysis (P=0.001, 0.004). Cardiac events occurred after 1.9% of normal stress tests by 2D analysis (combined 2D and M-mode: 0%), compared with 6.3% (3.8%) of normal resting studies. Worsening of serial DSE indicated an increased risk of events compared with no deterioration (relative risk 7.26, P=0.0014). Serial deterioration detected by stress only was associated with a higher risk of events than changes evident from resting studies (relative risk 3.06, P=0.0374). CONCLUSIONS: DSE identifies patients at risk for events and facilitates monitoring of CAV. A normal DSE predicts an uneventful clinical course and justifies postponement of invasive studies. The prognostic value of DSE is comparable to that of IVUS and angiography.


Assuntos
Angiografia Coronária , Doença das Coronárias/diagnóstico , Doença das Coronárias/etiologia , Ecocardiografia , Transplante de Coração , Ultrassonografia de Intervenção , Agonistas Adrenérgicos beta , Adulto , Fatores de Confusão Epidemiológicos , Doença das Coronárias/diagnóstico por imagem , Progressão da Doença , Dobutamina , Ecocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Risco , Transplante Homólogo , Ultrassonografia de Intervenção/métodos
7.
J Heart Lung Transplant ; 18(5): 391-8, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10363681

RESUMO

BACKGROUND: Coronary angiography is still the routine screening method for cardiac allograft vasculopathy in most transplant centers. This study was designed to analyze functional and morphologic changes in heart transplant recipients with normal angiographic findings. METHODS: Dobutamine stress echocardiography and intracoronary ultrasound were obtained in 56 patients with a normal coronary angiogram 41+/-31 months after heart transplantation. Intracoronary Doppler flow velocity measurements before and after intracoronary adenosine administration were performed in 34 of 56 patients. Any regional wall motion abnormalities detected by stress echocardiography were regarded as abnormal. By quantitative intracoronary ultrasound analysis using a 6-grade scale, a mean grade of all coronary segments >3.0 was defined as significant intimal hyperplasia. RESULTS: Only 17 patients (30%) showed both a normal dobutamine stress echocardiogram and absence of significant intimal hyperplasia by intravascularultrasound. Abnormal findings were observed in 39 patients (70%): both by dobutamine stress echocardiography and intravascular ultrasound in 22 patients, by intravascular ultrasound alone in 11 patients, and by dobutamine stress echocardiography alone in 6 patients. Coronary flow velocity reserve did not discriminate between patients with normal or abnormal intravascular ultrasound or dobutamine stress echocardiographic findings. CONCLUSIONS: Only a minority of heart transplant patients with a normal coronary angiogram is free of pathological changes, when assessed by intravascular ultrasound and dobutamine stress echocardiography. Coronary flow velocity reserve does not seem useful to further characterize these patients.


Assuntos
Cardiotônicos , Angiografia Coronária , Doença das Coronárias/diagnóstico , Vasos Coronários/patologia , Dobutamina , Ecocardiografia , Transplante de Coração , Ultrassonografia Doppler , Ultrassonografia de Intervenção , Adenosina/administração & dosagem , Biópsia , Velocidade do Fluxo Sanguíneo , Doença das Coronárias/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Teste de Esforço/métodos , Humanos , Injeções Intra-Arteriais , Pessoa de Meia-Idade , Vasodilatadores/administração & dosagem
8.
J Clin Endocrinol Metab ; 83(10): 3517-22, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9768657

RESUMO

Rapid nongenomic in vitro effects of aldosterone have been demonstrated recently in cultured vascular smooth muscle and endothelial cells. But there is, as yet, little evidence for corresponding in vivo effects. The present study thus investigates the rapid nongenomic effects of aldosterone on human cardiovascular function. In a double-blind placebo-controlled randomized parallel trial on 17 patients with suspected coronary heart disease, the effect of 1 mg aldosterone iv on cardiovascular function was assessed during cardiac catheterization. Hemodynamic parameters (such as heart rate, left ventricular and atrial pressures, arterial pressures, vascular resistances, and cardiac output) were measured before and 3 and 10 min after administration of aldosterone or placebo. Significant changes were found for systemic vascular resistance, cardiac output, and cardiac index, compared with the placebo group (Wilcoxon test, P < 0.02-0.05). The effect of aldosterone dissipated within 10 min. The results are in line with the in vitro data cited above and consistent with earlier findings on acute cardiovascular effects of aldosterone, which have now been confirmed and extended by contemporary techniques. The hypotheses of rapid nongenomic in vivo effects of aldosterone are further substantiated by this study.


Assuntos
Aldosterona/farmacologia , Sistema Cardiovascular/efeitos dos fármacos , Débito Cardíaco/efeitos dos fármacos , Método Duplo-Cego , Feminino , Hemodinâmica/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resistência Vascular/efeitos dos fármacos
9.
J Heart Lung Transplant ; 17(8): 795-800, 1998 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9730429

RESUMO

BACKGROUND: The aim of this study was to investigate whether adult human cardiomyocytes may reexpress vimentin and whether this is linked to cellular activation. METHODS: Myocardial samples of 81 heart transplant recipients (n=183) and patients with dilated cardiomyopathy (n=10) were investigated by immunohistochemistry with the use of the marker molecule vimentin, the muscle-specific protein desmin, and Ki67, a marker for cell activation. RESULTS: Vimentin protein expression in cardiomyocytes was found in 28 samples of transplant recipients and 5 myocardial samples of patients with dilated cardiomyopathy. Coexpression of vimentin and Ki67 was found in 52 of 340 vimentin-positive cardiomyocytes. CONCLUSIONS: We suggest that the vimentin/Ki67 coexpression indicates cell activation processes as the result of different growth stimuli.


Assuntos
Cardiomiopatia Dilatada/metabolismo , Rejeição de Enxerto/metabolismo , Transplante de Coração , Antígeno Ki-67/biossíntese , Miocárdio/metabolismo , Vimentina/biossíntese , Adulto , Feminino , Fase G1 , Humanos , Imuno-Histoquímica , Masculino , Fase de Repouso do Ciclo Celular
12.
Dtsch Med Wochenschr ; 122(11): 323-7, 1997 Mar 14.
Artigo em Alemão | MEDLINE | ID: mdl-9102280

RESUMO

HISTORY AND CLINICAL FINDINGS: A 58-year-old woman was admitted because of jaundice, ascites and marked oedema. For three years she had suffered from nervousness, decreasing fitness and weight loss, which had been assumed as due to chronic alcoholism. Liver biopsy revealed extensive fibrosis, in part with early cirrhotic transformation. This was followed by cardiac failure with atrial fibrillation (ventricular rate 140/min) and marked pleural effusions. The thyroid was diffusely enlarged and there were signs of exophthalmos. INVESTIGATIONS: Bilirubin concentration was 3 mg/dl, lactate dehydrogenase activity was 310 U/l, cholesterase 1.3 kU/l and the prothrombin test was 21%. The TSH level was 0.01 microU/ml while the free thyroxine level was 4.7 ng/dl and that of free triiodothyronine 13.5 pg/ml. Chest radiograph revealed cardiomegaly, bilateral peripheral pulmonary congestion and pleural effusions to midfield. Right heart catheterization excluded pulmonary hypertension; cardiac output was 10l/min. The thyroid was enlarged on ultrasound and diffusely echopoor, as in immune thyroid disease. TREATMENT AND COURSE: Cardiac failure regressed and thyroid function normalized within ten days on propranolol, 4 x 40 mg and thiamazole 3 x 40 mg daily intravenously. Subtotal thyroidectomy was performed three weeks later with subsequent thyroid hormone substitution. Liver functions were normal six months later and ultrasound showed no signs of cirrhotic change and the ascites had resolved. CONCLUSION: Hyperthyroidism is frequently associated with changes in liver functions. In extreme cases, high-output cardiac failure may occur, with liver congestion and clinical as well as histological changes like those in liver cirrhosis.


Assuntos
Doenças Autoimunes/complicações , Insuficiência Cardíaca/etiologia , Hipertireoidismo/complicações , Cirrose Hepática/etiologia , Antagonistas Adrenérgicos beta/uso terapêutico , Antiarrítmicos/uso terapêutico , Antitireóideos/uso terapêutico , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Doenças Autoimunes/diagnóstico por imagem , Doenças Autoimunes/terapia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Hipertireoidismo/diagnóstico por imagem , Hipertireoidismo/terapia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/terapia , Metimazol/uso terapêutico , Pessoa de Meia-Idade , Propranolol/uso terapêutico , Hormônios Tireóideos/uso terapêutico , Tireoidectomia , Ultrassonografia
13.
Am Heart J ; 133(1): 29-35, 1997 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9006287

RESUMO

To characterize plaque morphologic characteristics of transplant coronary artery disease early and late after cardiac transplantation, 72 patients were studied with intravascular ultrasonography during routine coronary angiography (group 1, 25 patients < or = 2 months after surgery; group 2, 47 patients > or = 12 months after surgery). Both groups had comparable baseline characteristics. Three hundred fifty-one segments were imaged in 127 coronary arteries (4.9 +/- 1.8 segments per patient). By intravascular ultrasonography, relevant intimal thickening (> 0.3 mm) was found in the majority of patients (68% for group 1 and 72% for group 2). Angiography detected abnormal findings in only 16% and 32% for groups 1 and 2, respectively. Mean intimal index was higher in patients late after transplantation (27% +/- 12% vs 17% +/- 12%, respectively; p < 0.01). Maximal and mean plaque thickness were comparable in both groups, whereas a higher mean plaque circumference was found in group 2 (278 +/- 66 degrees vs 211 +/- 75 degrees, respectively; p < 0.002). The lesions were more eccentric in patients early after transplantation (mean eccentricity index 95% +/- 7% vs 77% +/- 15%, respectively; p < 0.0001). Diffuse, concentric intimal thickening was not a common pattern. Maximal plaque thickness correlated with donor age (r = 0.50, p < 0.0001). Coronary lesions were frequent even early after transplantation, with predominantly eccentric plaque morphologic characteristics indicative of preexisting atherosclerosis. Later after transplantation, a more homogeneous plaque distribution was seen, partly with diffuse concentic intimal thickening. Late transplant coronary artery disease appears to be a combination of preexisting native and acquired immune-mediated coronary artery disease.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/patologia , Transplante de Coração/diagnóstico por imagem , Transplante de Coração/patologia , Adulto , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Ultrassonografia
14.
Z Kardiol ; 86(10): 868-76, 1997 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-9454455

RESUMO

Cardiac allograft vasculopathy (CAV) remains a major problem after heart transplantation. This prospective study was performed to analyze the value of quantitative dobutamine stress echocardiography for the diagnosis of CAV compared with coronary angiography and intravascular ultrasound (IVUS). In 80 patients late (> or = 12 months) after cardiac transplantation, a total of 144 studies were evaluated. In addition to the usually performed regional wall motion analysis of 2D-echocardiograms, systolic thickening of septum and left ventricular posterior wall was quantified by M-mode echocardiography. In patients with CAV by invasive angiography and/or IVUS, systolic thickening of the septum and posterior wall was significantly lower at rest and at maximum dobutamine infusion than in patients without CAV. From a subgroup of 23 studies in transplant recipients without TVP or other cardiac complications, normal values for the M-mode parameters were calculated. The lower limits were: systolic thickening of septum at rest, > 17.2%, at maximum stress, > 45.9%; systolic thickening of left ventricular posterior wall at rest, > 41.6%, at maximum stress, > 67.6%. Regional wall motion analysis of 2D-echocardiograms had a sensitivity of 76% (specificity 82%) for diagnosis of CAV defined by invasive methods, evaluation of wall thickening by M-mode alone had a sensitivity of 63% (specificity 76%). The combined 2D- and M-mode-echocardiographic analysis yielded a sensitivity of 85% (specificity 71%). In summary, dobutamine stress echocardiography is a useful method for the noninvasive diagnosis of CAV. The quantitative M-mode analysis improves the sensitivity of the 2D-analysis. The calculated normal values for the M-mode parameters in heart transplant recipients may serve as reference for other studies.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Dobutamina , Ecocardiografia , Teste de Esforço , Transplante de Coração/fisiologia , Complicações Pós-Operatórias/diagnóstico por imagem , Adulto , Angiografia Coronária , Doença das Coronárias/fisiopatologia , Feminino , Seguimentos , Rejeição de Enxerto/diagnóstico por imagem , Rejeição de Enxerto/fisiopatologia , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/fisiopatologia , Masculino , Pessoa de Meia-Idade , Contração Miocárdica/fisiologia , Complicações Pós-Operatórias/fisiopatologia , Sensibilidade e Especificidade , Ultrassonografia de Intervenção
15.
Z Kardiol ; 85(10): 753-60, 1996 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8943501

RESUMO

Previous Doppler studies of transmitral flow profiles in heart transplant recipients suggested left ventricular (LV) diastolic dysfunction. The influence of left atrial filling and emptying on mitral Doppler profiles in heart transplant recipients has not been studied systematically. In the present study, pulmonary venous flow profiles, mitral flow profiles, left atrial area change and mitral annulus motion were analyzed in 20 orthotopic heart transplant recipient and 20 control subjects by transthoracic and transesophageal echocardiography and Doppler. Mitral flow profiles revealed a "restrictive" pattern with a high early-to-late diastolic flow velocity ratio in transplant patients (2.16 +/- 0.52 vs. 1.30 +/- 0.25, p < 0.0001), which was mainly due to a reduced late diastolic maximum mitral flow velocity (32.6 +/- 8.3 vs. 51.6 +/- 12.4 cm/s, p < 0.0001). Left atrial area change (35.9 +/- 13.9 vs. 58.1 +/- 17.0%, p < 0.0006) and mitral annulus motion (9.2 +/- 3.3 vs. 12.2 +/- 2.0%, p < 0.05) were reduced in transplant recipients, compared to controls. Pulmonary venous flow parameters in transplant recipients were markedly altered during systole, when pulmonary venous flow parameters are influenced primarily by atrial function rather than by diastolic LV properties: peak systolic flow velocity (45.5 +/- 8.2 vs. 62.3 +/- 14.0 cm/s, p < 0.001), maximum flow velocity ratio (0.87 +/- 0.19 vs. 1.45 +/- 0.33), time velocity integral of pulmonary venous flow during systole (9.3 +/- 2.3 vs. 17.1 +/- 4.0 cm, p < 0.001) and the systolic fraction of the time velocity integral (52.6 +/- 10.8 vs. 68.5 +/- 6.8%, p < 0.001) were lower in heart transplant recipients than in controls. These findings are compatible with atrial dysfunction and reduced mitral annulus motion. The results of this study indicate that LV diastolic dysfunction is not the only possible cause of altered transmitral Doppler profiles in heart transplant recipients. Atrial abnormalities represent a major contributing factor to altered mitral and pulmonary venous flow patterns. Analysis of transmitral Doppler profiles alone are therefore not adequate for analysis of diastolic LV function in heart transplant recipients.


Assuntos
Ecocardiografia Doppler , Átrios do Coração/diagnóstico por imagem , Transplante de Coração/fisiologia , Pulmão/irrigação sanguínea , Valva Mitral/diagnóstico por imagem , Adulto , Função do Átrio Esquerdo/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Diástole/fisiologia , Ecocardiografia Transesofagiana , Feminino , Átrios do Coração/fisiopatologia , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/fisiopatologia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Sístole/fisiologia , Função Ventricular Esquerda/fisiologia
16.
Am J Cardiol ; 78(2): 168-74, 1996 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-8712138

RESUMO

This study was performed to assess the value of dobutamine stress echocardiography for noninvasive diagnosis of cardiac allograft vasculopathy (CAV) compared with coronary angiography and intravascular ultrasound (IVUS) in 50 consecutive orthotopic heart transplant recipients. In 46 of 50 patients, a technically adequate echocardiogram could be obtained. Using a 16-segment model, a total of 675 segments were analyzed. At rest, wall motion abnormalities were found in 61 of 675 (9.0%) left ventricular segments in 15 of 46 patients. At maximal dobutamine stress, 103 of 675 segments (15.3%) had wall motion abnormalities (25 of 46 patients). Based on IVUS and angiographic findings, patients were allocated to 2 groups. Group I (n=18) had absent or only mild intimal hyperplasia (mean IVUS grade < or = 3.0 on a 6-grade scale). Group II (n=28) had moderate to severe intimal hyperplasia (mean grade > 3.0 with or without angiographic evidence of CAV. The prevalence of wall motion abnormalities was significantly higher in group II than in group I, both at rest (50 of 415 vs 11 of 270 coronary segments in 13 of 28 vs 2 of 18 patients) and during maximal stress (88 of 415 vs 15 of 270 coronary segments in 22 of 28 vs 3 of 18 patients). Quantitative M-mode echocardiography demonstrated decreased wall thickening in group II versus group I patients at maximal dobutamine dosage in the septum (48 +/- 18% vs 61 +/- 17%; p < 0.01) as well as in the left ventricular posterior wall (77 +/- 21% vs 96 +/- 21%; p <0.005). Regional myocardial dysfunction as assessed by dobutamine stress echocardiography was associated with IVUS evidence of moderate to severe intimal hyperplasia. Dobutamine stress echocardiography appears to be a feasible noninvasive method for detection of CAV in heart transplant recipients, which may reduce the need for routine coronary angiography.


Assuntos
Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Ecocardiografia , Oclusão de Enxerto Vascular/diagnóstico por imagem , Transplante de Coração/efeitos adversos , Ultrassonografia de Intervenção , Adulto , Cardiotônicos , Dobutamina , Teste de Esforço , Estudos de Viabilidade , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
17.
J Am Soc Echocardiogr ; 8(6): 839-53, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-8611284

RESUMO

This study investigates the comparative sensitivity of video and radiofrequency imaging to detect changes of the myocardial acoustic properties after intravenous Albunex. Thirty-six patients received Albunex, 0.08 and 0.22 ml/kg intravenously, during transesophageal imaging of the ventricular short axis. Analysis of video images was performed in all patients and of radiofrequency data in 20 patients. Although myocardial videointensity remained unchanged, 57% of the myocardial backscatter plots demonstrated significant contrast enhancement. The study demonstrates that intravenous Albunex is capable of myocardial contrast enhancement and proves the diagnostic superiority of radiofrequency compared with video imaging. Ultrasonic radiofrequency imaging may provide a technical basis for future noninvasive assessment of myocardial perfusion.


Assuntos
Albuminas , Ecocardiografia Transesofagiana/métodos , Processamento de Imagem Assistida por Computador/métodos , Gravação em Vídeo , Adulto , Idoso , Albuminas/administração & dosagem , Aorta Abdominal/diagnóstico por imagem , Meios de Contraste , Feminino , Humanos , Injeções Intravenosas , Modelos Lineares , Masculino , Microesferas , Pessoa de Meia-Idade , Valor Preditivo dos Testes
20.
Z Kardiol ; 82(5): 324-31, 1993 May.
Artigo em Inglês | MEDLINE | ID: mdl-8328183

RESUMO

Orthotopic heart transplantation results in altered atrial anatomy and denervation of the donor heart. To assess the impact of these sequelae on left ventricular filling and systolic performance, 16 heart transplant recipients and 10 normal controls were evaluated by Doppler echocardiography at rest and during graded bicycle exercise. Global and regional systolic ventricular allograft function was normal at rest and during exercise. Resting Doppler profiles demonstrated diminished atrial contribution to ventricular filling in transplant recipients. The response to dynamic exercise was different in both groups; controls increased heart rate, while mitral time-velocity integral was unchanged. Heart transplant recipients, in contrast, showed a blunted heart rate response and increased time-velocity integral. Atrial contribution to ventricular filling was not augmented during exercise as in normal controls. Alterations in transmitral flow profiles in heart transplant recipients do not necessarily reflect ventricular myocardial damage, but may be related to impaired atrial function.


Assuntos
Ecocardiografia Doppler , Teste de Esforço , Transplante de Coração/fisiologia , Hemodinâmica/fisiologia , Complicações Pós-Operatórias/diagnóstico por imagem , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA