1.
Rev Sci Instrum ; 83(7): 073113, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22852677

RESUMO

A technological milestone for experiments employing transition edge sensor bolometers operating at sub-Kelvin temperature is the deployment of detector arrays with 100s-1000s of bolometers. One key technology for such arrays is readout multiplexing: the ability to read out many sensors simultaneously on the same set of wires. This paper describes a frequency-domain multiplexed readout system which has been developed for and deployed on the APEX-SZ and South Pole Telescope millimeter wavelength receivers. In this system, the detector array is divided into modules of seven detectors, and each bolometer within the module is biased with a unique ∼MHz sinusoidal carrier such that the individual bolometer signals are well separated in frequency space. The currents from all bolometers in a module are summed together and pre-amplified with superconducting quantum interference devices operating at 4 K. Room temperature electronics demodulate the carriers to recover the bolometer signals, which are digitized separately and stored to disk. This readout system contributes little noise relative to the detectors themselves, is remarkably insensitive to unwanted microphonic excitations, and provides a technology pathway to multiplexing larger numbers of sensors.

2.
Rev Sci Instrum ; 82(9): 091301, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21974566

RESUMO

The Atacama pathfinder experiment Sunyaev-Zel'dovich (APEX-SZ) instrument is a millimeter-wave cryogenic receiver designed to observe galaxy clusters via the Sunyaev-Zel'dovich effect from the 12 m APEX telescope on the Atacama plateau in Chile. The receiver contains a focal plane of 280 superconducting transition-edge sensor (TES) bolometers instrumented with a frequency-domain multiplexed readout system. The bolometers are cooled to 280 mK via a three-stage helium sorption refrigerator and a mechanical pulse-tube cooler. Three warm mirrors, two 4 K lenses, and a horn array couple the TES bolometers to the telescope. APEX-SZ observes in a single frequency band at 150 GHz with 1' angular resolution and a 22' field-of-view, all well suited for cluster mapping. The APEX-SZ receiver has played a key role in the introduction of several new technologies including TES bolometers, the frequency-domain multiplexed readout, and the use of a pulse-tube cooler with bolometers. As a result of these new technologies, the instrument has a higher instantaneous sensitivity and covers a larger field-of-view than earlier generations of Sunyaev-Zel'dovich instruments. The TES bolometers have a median sensitivity of 890 µK(CMB)√s (NEy of 3.5 × 10(-4) √s). We have also demonstrated upgraded detectors with improved sensitivity of 530 µK(CMB)√s (NEy of 2.2 × 10(-4) √s). Since its commissioning in April 2007, APEX-SZ has been used to map 48 clusters. We describe the design of the receiver and its performance when installed on the APEX telescope.

3.
Rev Sci Instrum ; 80(9): 094501, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19791952

RESUMO

We have designed and demonstrated a superconducting quantum interference device (SQUID) array linearized with cryogenic feedback. To achieve the necessary loop gain, a 300-element series array SQUID is constructed from three monolithic 100-element series arrays. A feedback resistor completes the loop from the SQUID output to the input coil. The short feedback path of this linearized SQUID array (LISA) allows for a substantially larger flux-locked loop bandwidth as compared to a SQUID flux-locked loop that includes a room temperature amplifier. The bandwidth, linearity, noise performance, and 3 Phi(0) dynamic range of the LISA are sufficient for its use in our target application: the multiplexed readout of transition-edge sensor bolometers.

4.
Appl Opt ; 47(24): 4418-28, 2008 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-18716649

RESUMO

The South Pole Telescope is a 10 m diameter, wide-field, offset Gregorian telescope with a 966-pixel, millimeter-wave, bolometer array receiver. The telescope has an unusual optical system with a cold stop around the secondary. The design emphasizes low scattering and low background loading. All the optical components except the primary are cold, and the entire beam from prime focus to the detectors is surrounded by cold absorber.

5.
Radiat Res ; 120(1): 36-71, 1989 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-2798782

RESUMO

We present the final analysis of an experiment to study the interaction of a beam of 670A MeV neon ions incident on a water column set to different thicknesses. The atomic number Z (and, in some cases, the isotopic mass A) of primary beam particles and of the products of nuclear interactions emerging from the water column close to the central axis of the beam was obtained for nuclei between Be (Z = 4) and Ne (Z = 10) using a time-of-flight telescope to measure the velocity and a set of silicon detectors to measure the energy loss of each particle. The fluence of particles of a given charge was obtained and normalized to the incident beam intensity. Corrections were made for accidental coincidences between multiple particles triggering the TOF telescope and for interactions in the detector. The background due to beam particles interacting in beam line elements upstream of the detector was calculated. Sources of experimental artifacts and background in particle identification experiments designed to characterize heavy ion beams for radiobiological research are summarized, and some of the difficulties inherent in this work are discussed. Complete tables of absolutely normalized fluence spectra as a function of LET are included for reference purposes.


Assuntos
Neônio , Íons , Aceleradores de Partículas , Água
6.
Peptides ; 5(3): 463-70, 1984.
Artigo em Inglês | MEDLINE | ID: mdl-6473168

RESUMO

Beta-casomorphin (5) Tyr-Pro-Phe-Pro-Gly, a partial sequence of bovine beta-casein with moderate opioid properties and mu-receptor affinity, was modified by substituting for the natural L-amino acids their D-analogs, and D-pipecolic acid, as well as by amidation of the C-terminal. Substitution of D-Pro or D-pipecolic acid for L-Pro4 considerably increased the analgesic action and the potency on guinea-pig ileum of beta-casomorphin (5) as well as of casomorphin [4] amide. The resulting D-Pro4 analogs Deprolorphin and Deproceptin which showed high analgesic potency after both intracerebroventricular and intravenous administrations. Also, the substitution of D-Phe for L-Phe3 enhanced, even though to a lesser degree, the antinociceptive action. Both naltrexone and naloxone completely blocked the effects in vivo and in vitro. The substitution of D-Pro for L-Pro2 abolished the opioid-like actions, while substituting D-pipecolic acid for L-Pro2 resulted in an increased analgesic effect of remarkably long duration. The correlation of analgesic action with the effects on isolated organs separates the L-Pro4-substituted derivatives and D-Phe3-CM(5) from the other modified casomorphins and morphine, indicating that the analgesic potency of the former was about ten times that of the latter group in the case of identical GPI-potency. This may involve different subpopulations of opiate mu-receptors.


Assuntos
Analgésicos , Caseínas/farmacologia , Endorfinas/farmacologia , Sequência de Aminoácidos , Animais , Relação Dose-Resposta a Droga , Endorfinas/administração & dosagem , Meia-Vida , Injeções Intraventriculares , Masculino , Naltrexona/farmacologia , Ratos , Ratos Endogâmicos , Relação Estrutura-Atividade