Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
JAMA Pediatr ; 172(11): e182847, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30193325

RESUMO

Importance: In recent years, there has been an exponential increase in the research guiding pediatric mild traumatic brain injury (mTBI) clinical management, in large part because of heightened concerns about the consequences of mTBI, also known as concussion, in children. The CDC National Center for Injury Prevention and Control's (NCIPC) Board of Scientific Counselors (BSC), a federal advisory committee, established the Pediatric Mild TBI Guideline workgroup to complete this systematic review summarizing the first 25 years of literature in this field of study. Objective: To conduct a systematic review of the pediatric mTBI literature to serve as the foundation for an evidence-based guideline with clinical recommendations associated with the diagnosis and management of pediatric mTBI. Evidence Review: Using a modified Delphi process, the authors selected 6 clinical questions on diagnosis, prognosis, and management or treatment of pediatric mTBI. Two consecutive searches were conducted on PubMed, Embase, ERIC, CINAHL, and SportDiscus. The first included the dates January 1, 1990, to November 30, 2012, and an updated search included December 1, 2012, to July 31, 2015. The initial search was completed from December 2012 to January 2013; the updated search, from July 2015 to August 2015. Two authors worked in pairs to abstract study characteristics independently for each article selected for inclusion. A third author adjudicated disagreements. The risk of bias in each study was determined using the American Academy of Neurology Classification of Evidence Scheme. Conclusion statements were developed regarding the evidence within each clinical question, and a level of confidence in the evidence was assigned to each conclusion using a modified GRADE methodology. Data analysis was completed from October 2014 to May 2015 for the initial search and from November 2015 to April 2016 for the updated search. Findings: Validated tools are available to assist clinicians in the diagnosis and management of pediatric mTBI. A significant body of research exists to identify features that are associated with more serious TBI-associated intracranial injury, delayed recovery from mTBI, and long-term sequelae. However, high-quality studies of treatments meant to improve mTBI outcomes are currently lacking. Conclusions and Relevance: This systematic review was used to develop an evidence-based clinical guideline for the diagnosis and management of pediatric mTBI. While an increasing amount of research provides clinically useful information, this systematic review identified key gaps in diagnosis, prognosis, and management.


Assuntos
Concussão Encefálica/diagnóstico , Concussão Encefálica/terapia , Biomarcadores/análise , Criança , Técnica Delphi , Gerenciamento Clínico , Medicina Baseada em Evidências/métodos , Humanos , Testes Neuropsicológicos , Guias de Prática Clínica como Assunto , Prognóstico
2.
Chem Commun (Camb) ; 53(61): 8529-8532, 2017 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-28703825

RESUMO

The future of 89Zr-based immuno-PET is reliant upon the development of new chelators with improved stability compared to the currently used deferoxamine (DFO). Herein, we report the evaluation of the octadentate molecule DFO-HOPO (3) as a suitable chelator for 89Zr and a more stable alternative to DFO. The molecule showed good potential for the future development of a DFO-HOPO-based bifunctional chelator (BFC) for the radiolabelling of biomolecules with 89Zr. This work broadens the selection of available chelators for 89Zr in search of improved successors to DFO for clinical 89Zr-immuno-PET.

3.
Phys Med Biol ; 59(3): 715-31, 2014 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-24442479

RESUMO

The Albira Trimodal pre-clinical scanner comprises PET, SPECT and CT sub-systems and thus provides a range of pre-clinical imaging options. The PET component consists of three rings of single-crystal LYSO detectors with axial/transverse fields-of-view (FOVs) of 148/80 mm. The SPECT component has two opposing CsI detectors (100 × 100 mm2) with single-pinhole (SPH) or multi(9)-pinhole (MPH) collimators; the detectors rotate in 6° increments and their spacing can be adjusted to provide different FOVs (25 to 120 mm). The CT sub-system provides 'low' (200 µA, 35 kVp) or 'high' (400 µA, 45 kVp) power x-rays onto a flat-panel CsI detector. This study examines the performance characteristics and quantitative accuracy of the PET and SPECT components. Using the NEMA NU 4-2008 specifications (22Na point source), the PET spatial resolution is 1.5 + 0.1 mm on axis and sensitivity 6.3% (axial centre) and 4.6% (central 70 mm). The usable activity range is ≤ 10 MBq (18F) over which good linearity (within 5%) is obtained for a uniform cylinder spanning the axial FOV; increasing deviation from linearity with activity is, however, observed for the NEMA (mouse) line source phantom. Image uniformity axially is within 5%. Spatial resolution (SPH/MPH) for the minimum SPECT FOV used for mouse imaging (50 mm) is 1.5/1.7 mm and point source sensitivity 69/750 cps MBq­1. Axial uniformity of SPECT images (%CV of regions-of-interest counts along the axis) is mostly within 8% although there is a range of 30­40% for the largest FOV. The variation is significantly smaller within the central 40 mm. Instances of count rate nonlinearity (PET) and axial non-uniformity (SPECT) were found to be reproducible and thus amenable to empirical correction.


Assuntos
Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Camundongos , Imagens de Fantasmas
4.
Phys Med Biol ; 47(1): 137-48, 2002 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-11814222

RESUMO

Texture analysis of positron emission tomography (PET) images of the brain is a very difficult task, due to the poor signal to noise ratio. As a consequence, very few techniques can be implemented successfully. We use a new global analysis technique known as the Trace transform triple features. This technique can be applied directly to the raw sinograms to distinguish patients with Alzheimer's disease (AD) from normal volunteers. FDG-PET images of 18 AD and 10 normal controls obtained from the same CTI ECAT-953 scanner were used in this study. The Trace transform triple feature technique was used to extract features that were invariant to scaling, translation and rotation, referred to as invariant features, as well as features that were sensitive to rotation but invariant to scaling and translation, referred to as sensitive features in this study. The features were used to classify the groups using discriminant function analysis. Cross-validation tests using stepwise discriminant function analysis showed that combining both sensitive and invariant features produced the best results, when compared with the clinical diagnosis. Selecting the five best features produces an overall accuracy of 93% with sensitivity of 94% and specificity of 90%. This is comparable with the classification accuracy achieved by Kippenhan et al (1992), using regional metabolic activity.


Assuntos
Doença de Alzheimer/diagnóstico , Doença de Alzheimer/patologia , Tomografia Computadorizada de Emissão/métodos , Adulto , Automação , Diagnóstico por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Teóricos
5.
Neurosurgery ; 48(1): 64-8; discussion 68-9, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11152362

RESUMO

OBJECTIVE: To investigate the effects of smoking, hypertension, and sex on the phenotypic expression of familial intracranial aneurysms (FIAs). METHODS: We retrospectively reviewed the case records of 806 consecutive patients undergoing aneurysm surgery at our institution (1986-1995) and discovered 24 families with at least two affected siblings. Prevalence rates for the smoking, hypertension, and sex risk factors in these nuclear families were compared with those of patients with sporadic intracranial aneurysms (SIAs) and population-based control patients. RESULTS: Affected family members with FIAs exhibited prevalence rates of smoking and hypertension (74% and 43%, respectively) that tended to be higher than those of population-based control patients (52% [P < 0.005] and 36% [P = not significant (NS)], respectively) and comparable to those of patients with SIAs (64% [P = NS] and 40% [P = NS], respectively). A positive association existed between FIA formation and female sex but was somewhat less strong than that observed in the SIAs (59% FIAs, 71% SIAs, 50% control patients). In addition, the prevalence rates of smoking, hypertension, and female sex were higher in affected family members with FIAs than in their unaffected siblings (58% [P < 0.05], 28% [P = 0.06], and 39% [P < 0.05], respectively). Individuals in families with expressed FIAs who had high aneurysmal penetrance had a greater tendency to be smokers, hypertensive, and female (74%, 59%, and 55%, respectively) than did their low-penetrance counterparts (61% [P = 0.1], 27% [P < 0.05], and 45% [P = NS], respectively). CONCLUSION: Together these data suggest that hypertension, smoking, and female sex increase the likelihood that a member of a family with an expressed FIA will have an aneurysm. These observations may prove helpful in guiding the use of screening studies and encouraging education about the potential risks of continued tobacco use and untreated hypertension in this patient cohort.


Assuntos
Hipertensão/complicações , Aneurisma Intracraniano/complicações , Aneurisma Intracraniano/genética , Caracteres Sexuais , Fumar/efeitos adversos , Estudos de Coortes , Feminino , Humanos , Hipertensão/epidemiologia , Aneurisma Intracraniano/cirurgia , Funções Verossimilhança , Masculino , Fenótipo , Prevalência , Estudos Retrospectivos , Distribuição por Sexo , Fumar/epidemiologia
6.
J Clin Endocrinol Metab ; 85(10): 3762-9, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11061536

RESUMO

Short-term studies of GH replacement in adult hypopituitarism have usually demonstrated beneficial effects on body composition and circulating lipids, with neutral or occasionally adverse effects on glucose tolerance. Fasting hyperinsulinemia has been reported. GH effects on cardiac function have been variable. The effects of long-term GH therapy, taking into account the consequences of increasing age, are not fully known. Thirty-three hypopituitary, initially middle-aged adults were studied over a 7-yr period; 12 patients took GH therapy (mean, 0.7 mg daily) continuously (group A); 11 took GH for only 6-18 months, a minimum of 5 yr previously (group B); and 10 patients never received GH therapy (group C). Other pituitary replacement was maintained. Effects on anthropometry, body composition (by bioimpedance analysis, total body potassium, and dual energy x-ray absorptiometry), circulating lipids, glucose and insulin concentrations, cardiac 2-dimensional and Doppler echocardiography, and exercise tolerance were assessed before and after the treatment period. Continuous GH therapy had no significant effect on body weight, but it prevented the increase in waist circumference and waist to hip ratio that occurred in the patients without GH substitution (waist to hip ratio, group A, 0.87+/-0.08 at baseline, 0.85+/-0.09 at 7 yr; group B, 0.89+/-0.11 at baseline, 0.94+/-0.11 at 7 yr; P < 0.005 for GH effect; group C, 0.87+/-0.10 at baseline, 0.92+/-0.10 at 7 yr; P < 0.005 for GH effect). A GH-induced decrease in subscapular skinfold thickness was also observed. By bioimpedance analysis, GH therapy caused an increase in total body water and fat-free mass, and a decrease in the percent body fat. Although changes occurred with time in all groups, no significant additional GH therapy effects were observed on glucose tolerance, insulin concentrations, lipid levels, cardiac dimensions, echocardiographic diastolic function, or exercise tolerance. In conclusion, prolonged GH substitution in middle-aged hypopituitary adults causes a sustained improvement in body composition. Other benefits, e.g. on lipid levels and exercise tolerance, were not apparent at 7 yr when comparisons were made with GH-untreated hypopituitary controls. Potentially adverse effects on glucose tolerance and insulinemia did not develop with prolonged GH therapy.


Assuntos
Hormônio do Crescimento/uso terapêutico , Hipopituitarismo/tratamento farmacológico , Absorciometria de Fóton , Glicemia/metabolismo , Pressão Sanguínea/fisiologia , Composição Corporal/efeitos dos fármacos , Estatura/fisiologia , Índice de Massa Corporal , Peso Corporal/fisiologia , Metabolismo dos Carboidratos , Ecocardiografia Doppler , Feminino , Seguimentos , Coração/fisiologia , Frequência Cardíaca/fisiologia , Terapia de Reposição Hormonal , Humanos , Hipopituitarismo/metabolismo , Hipopituitarismo/fisiopatologia , Metabolismo dos Lipídeos , Masculino , Pessoa de Meia-Idade , Potássio/sangue
7.
Phys Med Biol ; 45(9): 2601-18, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11008960

RESUMO

The 'EXACT3D' positron tomograph, which is now in routine clinical research use, was developed with the aim of achieving unprecedented sensitivity, high spatial and temporal resolution and simplicity of design using proven detector technology. It consists of six rings of standard detector blocks (CTI/Siemens EXACT HR+) with 4.39 mm x 4.05 mm x 30 mm elements, giving an axial field of view (FOV) of 23.4 cm. This extended FOV and the absence of interplane septa and retractable transmission rod sources has allowed greatly simplified gantry and detector cassette design. Operation in exclusive 3D mode requires an alternative to the conventional coincidence method for transmission scanning, and a single photon approach using a hydraulically driven 137Cs point source has been implemented. The tomograph has no other moving parts. A single time frame of data without any compression is very large (> 300 Mbyte) and two approaches are employed to overcome this difficulty: (a) adjacent sinograms can be summed automatically into different combinations and (b) listmode (event-by-event) acquisition has been instituted, which is both storage efficient (particularly for acquisition of sparse data sets) and maximizes temporal resolution. The high-speed I/O and computing hardware can maintain a sustained acquisition rate of about 4 million coincidence events per second. A disadvantage of the large axial FOV in 3D is the increased sensitivity to activity outside the coincidence FOV. However, this can be minimized by additional side shielding. The mean spatial resolution is 4.8 +/- 0.2 mm FWHM (transaxial, 1 cm off-axis) and 5.6 +/- 0.5 mm (axial, on-axis). Its absolute efficiency is 5.8% for a line source in air (just spanning the axial FOV) and 10% for a central point source (with thresholds of 350-650 keV). For a uniform 20 cm diameter cylinder, the efficiency is 69 kcps kBq(-1) ml(-1) (after subtraction of a scatter fraction of 42%). Sensitivity relative to the EXACT HR+ (with four rings of blocks) is 2.5 (3D) and 12 (2D) times respectively. The rate of random events in blood flow studies in the brain and body, using 15O-labelled water, can be controlled by limiting the administered dose and inserting additional side shielding.


Assuntos
Imagens de Fantasmas , Radioisótopos , Tomografia Computadorizada de Emissão/instrumentação , Tomografia Computadorizada de Emissão/métodos , Radioisótopos de Césio , Desenho de Equipamento , Germânio , Humanos , Radioisótopos do Iodo , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Radioisótopos de Tálio
8.
Phys Med Biol ; 45(8): 2417-39, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10958204

RESUMO

We present an enhancement of the OSEM (ordered set expectation maximization) algorithm for 3D PET reconstruction, which we call the inter-update Metz filtered OSEM (IMF-OSEM). The IMF-OSEM algorithm incorporates filtering action into the image updating process in order to improve the quality of the reconstruction. With this technique, the multiplicative correction image--ordinarily used to update image estimates in plain OSEM--is applied to a Metz-filtered version of the image estimate at certain intervals. In addition, we present a software implementation that employs several high-speed features to accelerate reconstruction. These features include, firstly, forward and back projection functions which make full use of symmetry as well as a fast incremental computation technique. Secondly, the software has the capability of running in parallel mode on several processors. The parallelization approach employed yields a significant speed-up, which is nearly independent of the amount of data. Together, these features lead to reasonable reconstruction times even when using large image arrays and non-axially compressed projection data. The performance of IMF-OSEM was tested on phantom data acquired on the GE Advance scanner. Our results demonstrate that an appropriate choice of Metz filter parameters can improve the contrast-noise balance of certain regions of interest relative to both plain and post-filtered OSEM, and to the GE commercial reprojection algorithm software.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Emissão/instrumentação , Tomografia Computadorizada de Emissão/métodos , Algoritmos , Fenômenos Biofísicos , Biofísica , Modelos Estatísticos , Imagens de Fantasmas , Software
9.
J Clin Endocrinol Metab ; 84(8): 2596-602, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10443645

RESUMO

The long term effects of GH replacement in adult GH-deficient (GHD) patients have not yet been clarified. We studied 21 GHD adults who originally took part in a randomized, double blind, placebo-controlled trial of GH treatment in 1987. After completion of that trial, 10 patients received continuous GH replacement for the subsequent 10 yr, whereas 11 did not. A group of 11 age- and sex-matched normal controls were also studied in 1987 and 1997. Lean body mass, as assessed by total body potassium measurement and computed tomography scanning of the dominant thigh, increased in the GH-treated group (P < 0.01 for both) only (P < 0.05 between groups for total body potassium). Low density lipoprotein cholesterol decreased in the GH-treated group (P < 0.05) only. Carotid intima media thickness was significantly greater (P < 0.05) in the untreated group than in the GH-treated group. Assessment of psychological well-being using the Nottingham Health Profile revealed improvement in overall score, energy levels, and emotional reaction in the GH-treated group compared with those in the untreated group (P < 0.02). In conclusion, GH treatment for 10 yr in GHD adults resulted in increased lean body and muscle mass, a less atherogenic lipid profile, reduced carotid intima media thickness, and improved psychological well-being.


Assuntos
Hormônio do Crescimento/uso terapêutico , Hormônio do Crescimento Humano/deficiência , Adulto , Pressão Sanguínea/efeitos dos fármacos , Composição Corporal , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
10.
J Nucl Med ; 39(10): 1696-702, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9776271

RESUMO

UNLABELLED: The measurement of regional myocardial blood flow (MBF) with H2(15)O and PET requires an additional C15O blood-pool scan for the purpose of region of interest (ROI) definition. This additional scan results in a substantially increased radiation dose, study duration and risk of movement artifacts. Therefore, a method was developed to generate myocardial factor images directly from the dynamic H2(15)O study without the need for a C15O scan. METHODS: The factor sinograms were generated by means of linear dimension reduction of the dynamic sinograms, where the required variate and covariate factors (myocardial and blood time-activity curves) were modeled from the lung time-activity curve. The factor images were generated by iterative reconstruction. RESULTS: No significant difference was found between MBF values from ROIs drawn on the traditional images (using the C15O scan) and those drawn on the factor images. CONCLUSION: It is possible to generate myocardial images directly from the dynamic H2(15)O study, so that the C15O scan can be omitted from MBF studies. The proposed method is robust and results in nearly optimal signal-to-noise ratios in the factor images.


Assuntos
Monóxido de Carbono , Imagem do Acúmulo Cardíaco de Comporta , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Radioisótopos de Oxigênio , Água , Estudos de Casos e Controles , Circulação Coronária/fisiologia , Humanos , Isquemia Miocárdica/diagnóstico por imagem
11.
Phys Med Biol ; 43(4): 777-86, 1998 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9572503

RESUMO

The aim of this paper is to report on experience with 3D positron emission tomography (PET) in our institute where we have three 3D scanners, of which two operate exclusively in 3D mode (ECAT ART, EXACT 3D). Fully 3D PET requires attention to a number of factors which are not as problematic in 2D PET. Firstly, 3D tomographs designed for whole-body acquisition suffer from a large single-photon field of view, extending well beyond the coincidence field of view. Single photons from outside the coincidence field of view increase the dead time and random coincidence rates, and contribute scattered events. For brain studies, we have extended the lead side shielding at the ends of the tomograph to mitigate against these effects, and this has dramatically improved the count rate performance. This approach is not as effective for whole-body scanning. In addition, operating in 3D without septa necessitates new approaches to transmission scanning, as measurements using positron emitters such as 68Ge/68Ga have the unfavourable characteristics of high dead time and high scatter. Both of our fully 3D scanners use 137Cs for single-photon transmission measurements, although the data are treated differently. On the ECAT ART, a combination of physical and electronic collimation effectively reduces transmission scatter to acceptable levels. On the EXACT 3D physical collimation is not as readily implemented and therefore segmentation and reassignment of the histogrammed attenuation (mu) values is employed to produce unbiased attenuation correction factors in 3D. Many of the lessons learnt with these BGO (bismuth germanate) based tomographs will be applicable to the next generation of systems using faster detectors such as lutetium oxyorthosilicate (LSO).


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada de Emissão/instrumentação , Tomografia Computadorizada de Emissão/métodos , Radioisótopos de Césio , Desenho de Equipamento , Radioisótopos de Gálio , Germânio , Humanos , Chumbo , Fótons , Proteção Radiológica , Radioisótopos , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
12.
Phys Med Biol ; 43(4): 895-904, 1998 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9572513

RESUMO

The ECAT EXACT3D (CTI/Siemens 966) 3D-only PET tomograph has unprecedented sensitivity due to the large BGO (bismuth germanate) detector volume. However, the consequences of a large (23.4 cm) axial field-of-view (FOV) and the need for a patient port diameter to accommodate body scanning make the device more sensitive to photons arising from activity outside the direct (coincidence) FOV. This leads to relatively higher deadtime and an increased registration of random and scatter (true) coincidences. The purpose of this study is to determine the influence of activity outside the FOV on (i) noise-equivalent counts (NEC) and (ii) the performance of a 'model-based' scatter correction algorithm, and to investigate the effect of side shielding additional to that supplied with the tomograph. Annular shielding designed for brain scanning increased the NEC for blood flow (H[2]15O) measurement (integrated over 120 s) by up to 25%. For 11C tracer studies, the increase is less than 5% over 120 min. Purpose-built additional body shielding, made to conform to the shape of a volunteer, reduced the randoms count rate in a heart blood flow measurement (H[2]15O) by about 30%. After scatter correction the discrepancy between ROI count ratios for compartments within the 20 cm diameter 'Utah' phantom differed by less than 5% from true (sampled) activity concentration ratios. This was so with or without activity outside the FOV and with or without additional side shielding. Count rate performance is thus improved by extra shielding but more improvement is seen in head than in body scanning. Measurement of heart blood flow using bolus injections of H(2)15O would benefit from the use of detectors with lower deadtime and superior timing resolution such as LSO (lutetium oxyorthosilicate).


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia Computadorizada de Emissão/instrumentação , Tomografia Computadorizada de Emissão/métodos , Algoritmos , Radioisótopos de Carbono , Desenho de Equipamento , Humanos , Modelos Teóricos , Fótons , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
13.
Phys Med Biol ; 42(6): 1143-54, 1997 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9194134

RESUMO

A fast iterative method is presented for calculating single detector efficiencies for positron emission tomographs. These efficiencies can be used to extend the normalization scan to areas outside that covered by the normalization source. The root mean square (rms) error of the calculated single detector efficiencies decreases exponentially with the number of iterations. Thirty iterations per normalization image are sufficient and take about 1 s on a SUN Classic. The geometry factors are composed of factors which only depend on the distance from the centre of the field-of-view (FOV) and of factors which show a more complex pattern over the normalization sinogram. The geometry factors are specific to each scanner. On the ECAT 931 scanner the complex part of the geometry factors showed a diamond shaped pattern (caused by the varying sensitivity of single detectors in a detector block with varying angle of incidence) and S-shaped curves (representing attenuation caused by supporting rods for the ring source). The coefficient of variation of the diamond-shaped pattern was 4% for detectors farthest from the centre of the FOV. Extensions of the normalization scan may, therefore, contain a relative rms error of about 4% if the applied geometry factors only take the distance from the centre of the FOV into account.


Assuntos
Tomografia Computadorizada de Emissão/métodos , Fenômenos Biofísicos , Biofísica , Humanos , Modelos Teóricos , Tomografia Computadorizada de Emissão/estatística & dados numéricos
14.
Phys Med Biol ; 42(2): 389-400, 1997 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9044420

RESUMO

Recently, the initial 2D physical characterization of a small-diameter positron emission tomograph, designed specifically for scanning of small laboratory animals, was reported. The physical characteristics of the tomograph operating in 3D mode have now been measured and compared to those obtained in 2D mode. In 3D, the transaxial resolution was measured as 2.4 +/- 0.1 mm full width at half maximum (FWHM) and 6.7 +/- 1.1 mm full width at tenth maximum (FWTM) at the centre of the transaxial field of view (FOV). These values degraded to 4.5 +/- 0.3 mm (tangential) and 6.6 +/- 0.3 mm (radial) FWHM and 10.6 +/- 1.6 mm (tangential) and 11.2 +/- 2.1 mm (radial) FWTM, respectively, at a distance of 40 mm from the centre of the transaxial FOV. The axial resolution was measured as 4.6 +/- 0.1 mm FWHM and 15.0 +/- 0.5 mm FWTM at the centre of the transaxial FOV, increasing to 5.0 +/- 0.1 mm FWHM and 18.8 +/- 3.7 mm FWTM at a radial distance of 40 mm from the centre of the transaxial FOV. These resolutions are similar to those obtained for the tomograph operating in 2D mode. The sensitivity of the tomograph operating in 3D was 4.31 x 10(4) counts s-1 MBq-1 at 250-850 keV compared to 0.995 x 10(4) counts s-1 MBQ-1 in 2D at the same energy thresholds. In this energy window the noise equivalent count rate peaked at 4.1 x 10(4) counts s-1, compared to 1.03 x 10(4) counts s-1 in 2D. A scatter fraction of 30.2% at 250-850 keV was measured for a 18F line source centered in a 60 mm diameter water filled phantom in 3D, compared to 31.0% in 2D for the same scanning geometry and energy thresholds. A comparison was made between 2D and 3D kinetic analyses for a group of five anaesthetized rats scanned using [11C] SCH 23390, a marker of dopamine D1 receptors. The integrity of the results was maintained between 2D and 3D data sets, though in 3D there was a significant reduction in the standard error of the fitted parameter. The results demonstrate that, with regard to sensitivity, there are significant gains in the physical performance of this tomograph when operating in 3D compared to 2D mode and that the quantification of PET studies of small animals using the 3D data reflects this.


Assuntos
Encéfalo/diagnóstico por imagem , Tomografia Computadorizada de Emissão/instrumentação , Animais , Animais de Laboratório , Benzazepinas/farmacocinética , Encéfalo/metabolismo , Radioisótopos de Carbono/farmacocinética , Corpo Estriado/diagnóstico por imagem , Corpo Estriado/metabolismo , Cinética , Ratos , Receptores de Dopamina D1/análise , Receptores de Dopamina D1/metabolismo , Espalhamento de Radiação , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão/métodos
15.
Dig Dis Sci ; 42(1): 79-82, 1997 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9009119

RESUMO

Multiple studies link the use of nonsteroidal antiinflammatory drugs (NSAIDs) with severe upper gastrointestinal bleeding (UGIB); the incidence of such bleeding is 2-4%. One common regimen to assure patency after intracoronary stent placement requires an anticoagulant (warfarin) combined with aspirin as an antiplatelet agent. However, a 13-fold increase in the risk of UGIB occurs with long-term use of oral anticoagulants and NSAIDs. We retrospectively assessed the rate of UGIB in 138 patients who had received coronary stents (group I, receiving heparin followed by warfarin in combination with aspirin) and 109 angioplasty patients without stents (group II, receiving aspirin alone) between 1990 and 1994. UGIB was identified by hematemesis or melena, which led to gastrointestinal consultation. Patients were analyzed for multiple risk factors. UGIB occurred in 28 of 138 group I patients (20%; 95% CI 13.3-26.7%) and 0 of 109 group II patients (P < 0.0001). Esophagogastroduodenoscopy (EGD) findings on the 28 patients with UGIB included 13 patients with esophagitis or gastritis, 7 patients with gastric or duodenal ulcers, and 8 patients with no identifiable source of bleeding. UGIB occurred within a mean of 2.5 days of initiation of combination therapy. Of patients with UGIB, 10 required blood transfusion (mean number of units = 5.3). Previous history of peptic ulcer disease, smoking, and use of antiulcer medication did not significantly differ between the two groups. The concurrent use of anticoagulant and aspirin in patients with coronary stents creates a significant potential for UGIB and should be used only with extreme caution.


Assuntos
Anti-Inflamatórios não Esteroides/efeitos adversos , Anticoagulantes/efeitos adversos , Aspirina/efeitos adversos , Hemorragia Gastrointestinal/induzido quimicamente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/efeitos adversos , Anti-Inflamatórios não Esteroides/administração & dosagem , Anticoagulantes/administração & dosagem , Aspirina/administração & dosagem , Quimioterapia Combinada , Heparina/administração & dosagem , Heparina/efeitos adversos , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Stents/efeitos adversos , Trombose/etiologia , Trombose/prevenção & controle , Varfarina/administração & dosagem , Varfarina/efeitos adversos
16.
Eur J Nucl Med ; 24(1): 6-15, 1997 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9044879

RESUMO

Advances in fully three-dimensional (3D) image reconstruction techniques have permitted the development of a commercial, rotating, partial ring, fully 3D positron emission tomographic (PET) scanner, the ECAT ART. The system has less than one-half the number of bismuth germanate detectors compared with a full ring scanner with the equivalent field of view, resulting in reduced capital cost. The performance characteristics, implications for installation in a nuclear medicine department, and clinical utility of the scanner are presented in this report. The sensitivity (20 cm diameterx20 cm long cylindrical phantom, no scatter correction) is 11400 cps.kBq-1.ml-1. This compares with 5800 and 40500 cps.kBq-1.ml-1 in 2D and 3D respectively for the equivalent full ring scanner (ECAT EXACT). With an energy window of 350-650 keV the maximum noise equivalent count (NEC) rate was 27 kcps at a radioactivity concentration of approximately 15 kBq.ml-1 in the cylinder. Spatial resolution is approximately 6 mm full width at half maximum on axis degrading to just under 8 mm at a distance of 20 cm off axis. Installation and use within the nuclear medicine department does not appreciably increase background levels of radiation on gamma cameras in adjacent rooms and the dose rate to an operator in the same room is 2 microSv. h-1 for a typical fluorine-18 fluorodeoxyglucose (18F-FDG) study with an initial injected activity of 370 MBq. The scanner has been used for clinical imaging with18F-FDG for neurological and oncological applications. Its novel use for imaging iron-52 transferrin for localising erythropoietic activity demonstrates its sensitivity and resolution advantages over a conventional dual-headed gamma camera. The ECAT ART provides a viable alternative to conventional full ring PET scanners without compromising the performance required for clinical PET imaging.


Assuntos
Câmaras gama , Tomografia Computadorizada de Emissão/instrumentação , Desenho de Equipamento , Humanos , Serviço Hospitalar de Medicina Nuclear , Rotação , Tecnologia Radiológica/instrumentação
17.
Phys Med Biol ; 41(12): 2757-74, 1996 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-8971967

RESUMO

A method for scatter correction using dual energy window acquisition has been developed and implemented on data collected with a brain-PET tomograph operated in the septa retracted, 3D mode. Coincidence events are assigned to (i) an upper energy window where both photons deposit energy between 380 keV and 850 keV or (ii) a lower energy window where one or both photons deposit within 200 keV and 380 keV. Scaling parameters are derived from measurements of the ratios of counts from line sources due to scattered and unscattered events in the two energy windows in head-sized phantoms. A scaled subtraction of the two energy windows produces a distribution of scatter which is smoothed prior to subtraction from the upper energy window. In phantoms, the correction was found to restore the uniformity, contrast and linearity of activity concentration. Relative activity concentrations were restored to within 7% of their true values in a multicompartment phantom. The method was found to provide accurate correction for scattered events arising from activity outside the direct detector field of view. In a three-compartment phantom containing water, 18F and 11C scanned in dynamic, multiframe mode, the half-lives of the two isotopes were restored to within 2% of their true value.


Assuntos
Encéfalo/diagnóstico por imagem , Imagens de Fantasmas , Tomografia Computadorizada de Emissão , Humanos , Reprodutibilidade dos Testes , Espalhamento de Radiação , Tomografia Computadorizada de Emissão/instrumentação , Tomografia Computadorizada de Emissão/métodos
19.
Phys Med Biol ; 40(6): 1105-26, 1995 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-7659733

RESUMO

A small diameter positron emission tomography, designed specifically for small animal studies, was constructed from existing, commercially available, bismuth germanate (BGO) detectors and electronics. The scanner consists of 16 BGO detector blocks arranged to give a tomograph with a diameter of 115 mm and an axial field of view (FOV) of 50 mm. Each block is cut to produce eight (axial) by seven (radial) individual detector elements. The absence of interplane septa enables the acquisition of 3D data sets consisting of 64 sinograms. A 2D data set of 15 sinograms, consisting of eight direct and seven adjacent cross planes, can be extracted from the 3D data set. Images are reconstructed from the 2D sinograms using a conventional filtered backprojection algorithm. Two methods of normalization were investigated, based on either a rotating 68Ge rod source, or a uniform 68Ge plane source, with a uniform cylindrical 18F phantom. Attenuation of the emitted photons was estimated using a rotating 68Ge rod source. The transaxial resolution of the tomograph was measured as 2.3 mm full width at half maximum (FWHM) and 5.6 mm full width at tenth maximum (FWTM) at the centre of the FOV, degrading to 6.6 mm (radial) and 4.4 mm (tangential) FWHM and 10.4 mm (radial) and 14.4 mm (tangential) FWTM at 40.0 mm from the centre of the FOV. The axial slice width was 4.3 mm FWHM, 10.3 mm FWTM at the centre of the transaxial field of view and 4.4 mm FWHM, 10.6 mm FWTM at 20.0 mm from the centre of the FOV. A scatter fraction of 31.0% was measured at 250-850 keV, for an 18F line source centred in a 60 mm diameter, water-filled phantom, reducing to 20.4% and 13.8% as the lower energy discrimination was increased to 380 keV and 450 keV, respectively. The count rate performance was measured using a noise equivalent count rate method, and the linearity of the dead time correction was confirmed over the count rates encountered during routine scanning. In 2D mode, the absolute sensitivity of the tomograph was measured as 9948 counts s-1 MBq-1 at 250-850 keV, 8284 counts s-1 MBq-1 at 380-850 keV and 6280 counts s-1 MBq-1 at 450-850 keV.


Assuntos
Modelos Estruturais , Tomografia Computadorizada de Emissão/instrumentação , Animais , Constituição Corporal , Desenho de Equipamento , Radioisótopos de Flúor , Germânio , Matemática , Radioisótopos , Tomografia Computadorizada de Emissão/métodos
20.
J Cereb Blood Flow Metab ; 13(4): 617-29, 1993 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8314915

RESUMO

Positron emission tomography regional CBF (rCBF) studies of cognitive processes have traditionally required 30-60 mCi of H2(15)O per scan and intersubject averaging to achieve statistical significance. However, intersubject anatomical, functional, and disease variability can make such an approach problematic. A new method that produces significant results in single subjects is presented. It is based upon high-sensitivity three-dimensional imaging and a "slow" bolus administration of < 15 mCi of H2(15)O per scan. The method is validated in four normal volunteers using control and auditory-language activation tasks with four scans per condition and statistical parametric mapping analysis. It is demonstrated that the rCBF distribution associated with the cognitive state is detected during the arrival of radiotracer in the brain. This occurs over 30 s and constitutes a critical temporal window during which stimulation should be performed. A 90-s acquisition time is found to produce results of greater significance than a 60-s acquisition time. The implications of the results and the functional neuroanatomical findings are discussed. This method is suitable for the study of individual functional neuroanatomy in many neuropsychological, pharmacologic, and symptom states in normal subjects and in patients with psychiatric and neurologic disorders.


Assuntos
Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular , Cognição/fisiologia , Tomografia Computadorizada de Emissão/métodos , Adulto , Eletricidade , Humanos , Masculino , Radioisótopos de Oxigênio , Fatores de Tempo , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...