Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Oncol ; 16(1): 65, 2021 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-33823885

RESUMO

BACKGROUND: This work addresses a basic inconsistency in the way dose is accumulated in radiotherapy when predicting the biological effect based on the linear quadratic model (LQM). To overcome this inconsistency, we introduce and evaluate the concept of the total biological dose, bEQDd. METHODS: Daily computed tomography imaging of nine patients treated for prostate carcinoma with intensity-modulated radiotherapy was used to compute the delivered deformed dose on the basis of deformable image registration (DIR). We compared conventional dose accumulation (DA) with the newly introduced bEQDd, a new method of accumulating biological dose that considers each fraction dose and tissue radiobiology. We investigated the impact of the applied fractionation scheme (conventional/hypofractionated), uncertainties induced by the DIR and by the assigned α/ß-value. RESULTS: bEQDd was systematically higher than the conventionally accumulated dose with difference hot spots of 3.3-4.9 Gy detected in six out of nine patients in regions of high dose gradient in the bladder and rectum. For hypofractionation, differences are up to 8.4 Gy. The difference amplitude was found to be in a similar range to worst-case uncertainties induced by DIR and was higher than that induced by α/ß. CONCLUSION: Using bEQDd for dose accumulation overcomes a potential systematic inaccuracy in biological effect prediction based on accumulated dose. Highest impact is found for serial-type late responding organs at risk in dose gradient regions and for hypofractionation. Although hot spot differences are in the order of several Gray, in dose-volume parameters there is little difference compared with using conventional or biological DA. However, when local dose information is used, e.g. dose surface maps, difference hot spots can potentially change outcomes of dose-response modelling and adaptive treatment strategies.


Assuntos
Neoplasias da Próstata/radioterapia , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Masculino , Órgãos em Risco , Hipofracionamento da Dose de Radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Incerteza
2.
Aesthetic Plast Surg ; 45(3): 1273-1281, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32968820

RESUMO

BACKGROUND: Irradiation therapy limits the utilization of silicone implants for breast reconstruction due to a significant risk for capsular contracture. The injection of the collagenase of the bacterium Clostridium histolyticum (CCH) might trivialize this risk by providing a minimal-invasive treatment option by capsular contracture degradation. However, efficacy in degrading breast implant capsules induced by fractionated irradiation remains unclear. METHODS: Twenty-four rats in three groups received miniature silicone implants in a submuscular pocket. After 3D dose calculation and treatment field definition, rats of two groups underwent fractionated radiotherapy (6 × 8 Gy) using a linear accelerator. A third group served as control. On day 120, one irradiated group received injections of 0.3 mg/ml collagenase. Administration of plain solvent solution served as control in the two other groups. Outcome parameters included CT-imaging, histology, vessel wall analysis, immunohistochemistry, chemical collagen quantification and gene expression analysis. RESULTS: Fractioned irradiation leads to a significant increase in collagen deposition around silicone implants with higher capsule thickness and collagen density when comparing all groups. Additionally, significant alterations of collagen fiber deposition were evident. Vessel wall thickness was significantly increased after radiotherapy. The injection of collagenase led to a significant reduction of capsule thickness, collagen density and content. However, the collagenase application induced a significant overexpression of TGFß1. No side effects were monitored. CONCLUSIONS: The CCH proved to be a safe and effective approach to degrade capsule tissue induced by fractionated irradiation in an animal model. This may pave its way for clinical application in implant-based breast reconstruction patients. LEVEL OF EVIDENCE: This journal requires that authors assign a level of evidence to each submission to which Evidence-Based Medicine rankings are applicable. This excludes Review Articles, Book Reviews, and manuscripts that concern Basic Science, Animal Studies, Cadaver Studies, and Experimental Studies. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Implante Mamário , Implantes de Mama , Contratura , Animais , Implantes de Mama/efeitos adversos , Clostridium histolyticum , Colagenases , Humanos , Contratura Capsular em Implantes/etiologia , Ratos
3.
Front Oncol ; 10: 564857, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33363005

RESUMO

PURPOSE: To evaluate the potential of cone-beam-CT (CB-CT) guided adaptive radiotherapy (ART) for locally advanced non-small cell lung cancer (NSCLC) for sparing of surrounding organs-at-risk (OAR). MATERIALS AND METHODS: In 10 patients with locally advanced NSCLC, daily CB-CT imaging was acquired during radio- (n = 4) or radiochemotherapy (n = 6) for simulation of ART. Patients were treated with conventionally fractionated intensity-modulated radiotherapy (IMRT) with total doses of 60-66 Gy (pPlan) (311 fraction CB-CTs). OAR were segmented on every daily CB-CT and the tumor volumes were modified weekly depending on tumor changes. Doses actually delivered were recalculated on daily images (dPlan), and voxel-wise dose accumulation was performed using a deformable registration algorithm. For simulation of ART, treatment plans were adapted using the new contours and re-optimized weekly (aPlan). RESULTS: CB-CT showed continuous tumor regression of 1.1 ± 0.4% per day, leading to a residual gross tumor volume (GTV) of 65.3 ± 13.4% after 6 weeks of radiotherapy (p = 0.005). Corresponding PTVs decreased to 83.7 ± 7.8% (p = 0.005). In the actually delivered plans (dPlan), both conformity (p = 0.005) and homogeneity (p = 0.059) indices were impaired compared to the initial plans (pPlan). This resulted in higher actual lung doses than planned: V20Gy was 34.6 ± 6.8% instead of 32.8 ± 4.9% (p = 0.066), mean lung dose was 19.0 ± 3.1 Gy instead of 17.9 ± 2.5 Gy (p = 0.013). The generalized equivalent uniform dose (gEUD) of the lung was 18.9 ± 3.1 Gy instead of 17.8 ± 2.5 Gy (p = 0.013), leading to an increased lung normal tissue complication probability (NTCP) of 15.2 ± 13.9% instead of 9.6 ± 7.3% (p = 0.017). Weekly plan adaptation enabled decreased lung V20Gy of 31.6 ± 6.2% (-3.0%, p = 0.007), decreased mean lung dose of 17.7 ± 2.9 Gy (-1.3 Gy, p = 0.005), and decreased lung gEUD of 17.6 ± 2.9 Gy (-1.3 Gy, p = 0.005). Thus, resulting lung NTCP was reduced to 10.0 ± 9.5% (-5.2%, p = 0.005). Target volume coverage represented by conformity and homogeneity indices could be improved by weekly plan adaptation (CI: p = 0.007, HI: p = 0.114) and reached levels of the initial plan (CI: p = 0.721, HI: p = 0.333). CONCLUSION: IGRT with CB-CT detects continuous GTV and PTV changes. CB-CT-guided ART for locally advanced NSCLC is feasible and enables superior sparing of healthy lung at high levels of plan conformity.

4.
Front Oncol ; 10: 564068, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33134166

RESUMO

BACKGROUND: To investigate deviations between planned and applied treatment doses for hypofractionated prostate radiotherapy and to quantify dosimetric accuracy in dependence of the image guidance frequency. METHODS: Daily diagnostic in-room CTs were carried out in 10 patients in treatment position as image guidance for hypofractionated prostate radiotherapy. Fraction doses were mapped to the planning CTs and recalculated, and applied doses were accumulated voxel-wise using deformable registration. Non-daily imaging schedules were simulated by deriving position correction vectors from individual scans and used to rigidly register the following scans until the next repositioning before dose recalculation and accumulation. Planned and applied doses were compared regarding dose-volume indices and TCP and NTCP values in dependence of the imaging and repositioning frequency. RESULTS: Daily image-guided repositioning was associated with only negligible deviations of analyzed dose-volume parameters and conformity/homogeneity indices for the prostate, bladder and rectum. Average CTV T did not significantly deviate from the plan values, and rectum NTCPs were highly comparable, while bladder NTCPs were reduced. For non-daily image-guided repositioning, there were significant deviations in the high-dose range from the planned values. Similarly, CTV dose conformity and homogeneity were reduced. While TCPs and rectal NTCPs did not significantly deteriorate for non-daily repositioning, bladder NTCPs appeared falsely diminished in dependence of the imaging frequency. CONCLUSION: Using voxel-by-voxel dose accumulation, we showed for the first time that daily image-guided repositioning resulted in only negligible dosimetric deviations for hypofractionated prostate radiotherapy. Regarding dosimetric aberrations for non-daily imaging, daily imaging is required to adequately deliver treatment.

5.
Front Oncol ; 10: 989, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32733794

RESUMO

Purpose: Proton radiotherapy (PRT) is potentially associated with a lower risk for secondary malignancies due to a decreased integral dose to the surrounding organs at risk (OARs). Prospective trials confirming this are lacking due to the need for long-term follow-up and the ethical complexities of randomizing patients between modalities. The objective of the current study is to calculate the risk for secondary malignancies following PRT and photon-based intensity-modulated radiotherapy (IMRT). Materials and Methods: Twenty-three patients (16 female and seven male), previously treated with active scanning PRT for malignant mediastinal lymphoma at Heidelberg Ion Beam Therapy Center, were retrospectively re-planned using helical photon IMRT. The risk for radiation-induced secondary malignancies was estimated and evaluated using two distinct prediction models (1-4). Results: According to the Dasu model, the median absolute total risk for tumor induction following IMRT was 4.4% (range, 3.3-5.8%), 9.9% (range, 2.0-27.6%), and 1.0% (range, 0.5-1.5%) for lung, breast, and esophageal cancer, respectively. For PRT, it was significantly lower for the aforementioned organs at 1.6% (range, 0.7-2.1%), 4.5% (range, 0.0-15.5), and 0.8% (range, 0.0-1.6%), respectively (p ≤ 0.01). The mortality risk from secondary malignancies was also significantly reduced for PRT relative to IMRT at 1.1 vs. 3.1% (p ≤ 0.001), 0.9 vs. 1.9% (p ≤ 0.001), and 0.7 vs. 1.0% (p ≤ 0.001) for lung, breast, and esophageal tumors, respectively. Using the Schneider model, a significant risk reduction of 54.4% (range, 32.2-84.0%), 56.4% (range, 16.0-99.4%), and 24.4% (range, 0.0-99.0%) was seen for secondary lung, breast, and esophageal malignancies, favoring PRT vs. X-ray-based IMRT (p ≤ 0.01). Conclusion: Based on the two prediction models, PRT for malignant mediastinal lymphoma is expected to reduce the risk for radiation-induced secondary malignancies compared with the X-ray-based IMRT. The young age and the long natural history of patients diagnosed with mediastinal lymphoma predisposes them to a high risk of secondary malignancies following curative radiotherapy treatment and, as a consequence, potentially reducing this risk by utilizing advanced radiation therapy techniques such as PRT should be considered.

6.
Front Oncol ; 9: 1191, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31788450

RESUMO

Background and purpose: To analyze divergences between the planned and applied treatment doses for post-prostatectomy radiotherapy to the prostatic fossa on a voxel-by-voxel basis based on interfractional anatomic variations and imaging frequency. Materials and methods: For 10 patients receiving intensity-modulated postoperative radiotherapy to the prostatic fossa, position verification was carried out by daily in-room CT imaging in treatment position (340 fraction CTs). Applied fraction doses were recalculated on daily CT scans, and treatment doses were accumulated on a voxel-by-voxel basis after deformable image registration. To simulate weekly imaging, derived weekly position correction vectors were used to rigidly register all daily scans of the respective treatment week onto the planning CT before dose accumulation. Detailed dose statistics of the prescribed and applied treatment doses were compared in relation to the frequency of position verification imaging. Derived NTCP and Pinjury values were calculated for the rectum and bladder. Results: Despite a large variability in the pelvic anatomy, daily CT-based patient repositioning resulted in largely negligible deviations of the analyzed dose-volume, conformity, and uniformity parameters from the planned doses for post-prostatectomy radiotherapy, and only the bladder exhibited significant increases in the accumulated mean and median doses. Derived NTCP for the applied doses to the rectum and bladder and Pinjury values did not significantly deviate from the treatment plan. In contrast, weekly CT-based repositioning resulted in significant decreases of the PTV coverage and dose conformity as well as large deviations of the applied doses to the rectum and bladder from the planned doses. Consecutively, NTCP for the rectum and Pinjury were found falsely reduced for weekly patient repositioning. Conclusions: Our data indicate for the first time in a voxel-by-voxel analysis that daily imaging is required for reliable adaptive delivery of intensity-modulated radiotherapy to the prostatic fossa. This work will help guiding adaptive treatment strategies for post-prostatectomy radiotherapy.

7.
Front Oncol ; 9: 940, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31612106

RESUMO

Background and purpose: To analyze deviations of the applied from the planned doses on a voxel-by-voxel basis for definitive prostate cancer radiotherapy depending on anatomic variations and imaging frequency. Materials and methods: Daily in-room CT imaging was performed in treatment position for 10 patients with prostate cancer undergoing intensity-modulated radiotherapy (340 fraction CTs). Applied fraction doses were recalculated on daily images, and voxel-wise dose accumulation was performed using a deformable registration algorithm. For weekly imaging, weekly position correction vectors were derived and used to rigidly register daily scans of that week to the planning CT scan prior to dose accumulation. Applied and prescribed doses were compared in dependence of the imaging frequency, and derived TCP and NTCP values were calculated. Results: Daily CT-based repositioning resulted in non-significant deviations of all analyzed dose-volume, conformity and uniformity parameters to the CTV, bladder and rectum irrespective of anatomic changes. Derived average TCP values were comparable, and NTCP values for the applied doses to the bladder and rectum did not significantly deviate from the planned values. For weekly imaging, the applied D2 to the CTV, rectum and bladder significantly varied from the planned doses, and the CTV conformity index and D98 decreased. While TCP values were comparable, the NTCP for the bladder erroneously appeared reduced for weekly repositioning. Conclusions: Based on daily diagnostic quality CT imaging and voxel-wise dose accumulation, we demonstrated for the first time that daily, but not weekly imaging resulted in only negligible deviations of the applied from the planned doses for prostate intensity-modulated radiotherapy. Therefore, weekly imaging may not be adequately reliable for adaptive treatment delivery techniques for prostate. This work will contribute to devising adaptive re-planning strategies for prostate radiotherapy.

8.
Strahlenther Onkol ; 194(5): 425-434, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29349601

RESUMO

BACKGROUND: The present work aimed to analyze the feasibility of a shuttle-based MRI-guided radiation therapy (MRgRT) in the treatment of pelvic malignancies. PATIENTS AND METHODS: 20 patients with pelvic malignancies were included in this prospective feasibility analysis. Patients underwent daily MRI in treatment position prior to radiotherapy at the German Cancer Research Center. Positional inaccuracies, time and patient compliance were assessed for the application of off-line MRgRT. RESULTS: In 78% of applied radiation fractions, MR imaging for position verification could be performed without problems. Additionally, treatment-related side effects and reduced patient compliance were only responsible for omission of MRI in 9% of radiation fractions. The study workflow took a median time of 61 min (range 47-99 min); duration for radiotherapy alone was 13 min (range 7-26 min). Patient positioning, MR imaging and CT imaging including patient repositioning and the shuttle transfer required median times of 10 min (range 7-14 min), 26 min (range 15-60 min), 5 min (range 3-8 min) and 8 min (range 2-36 min), respectively. To assess feasibility of shuttle-based MRgRT, the reference point coordinates for the x, y and z axis were determined for the MR images and CT obtained prior to the first treatment fraction and correlated with the coordinates of the planning CT. In our dataset, the median positional difference between MR imaging and CT-based imaging based on fiducial matching between MR and CT imaging was equal to or less than 2 mm in all spatial directions. The limited space in the MR scanner influenced patient selection, as the bore of the scanner had to accommodate the immobilization device and the constructed stereotactic frame. Therefore, obese, extremely muscular or very tall patients could not be included in this trial in addition to patients for whom exposure to MRI was generally judged inappropriate. CONCLUSION: This trial demonstrated for the first time the feasibility and patient compliance of a shuttle-based off-line approach to MRgRT of pelvic malignancies.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias Pélvicas/radioterapia , Radioterapia Guiada por Imagem/métodos , Adulto , Idoso , Tomografia Computadorizada de Feixe Cônico , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Avaliação de Processos e Resultados em Cuidados de Saúde , Posicionamento do Paciente , Neoplasias Pélvicas/diagnóstico por imagem , Neoplasias Pélvicas/patologia , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...