1.
ASAIO J ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38588597

RESUMO

Venoarterial extracorporeal membrane oxygenation (VA-ECMO) shunts venous blood to the systemic arterial circulation to provide end-organ perfusion while increasing afterload that may impede left ventricle (LV) ejection and impair cardiac recovery. To maintain flow across the aortic valve and reduce risk of lethal clot formation, secondary mechanical circulatory support (MCS) devices are increasingly used despite limited understanding of their effects on cardiac function. This study sought to quantify the effects of VA-ECMO and combined with either intraaortic balloon pump (IABP) or percutaneous ventricular assist device (pVAD) on LV physiologic state and perfusion metrics in a porcine model of acute cardiogenic shock. Shock was induced through serial left anterior descending artery microbead embolization followed by initiation of VA-ECMO support and then placement of either IABP or pVAD. Hemodynamic measurements, LV pressure-volume loops, and carotid artery blood flow were evaluated before and after institution of combined MCS. The IABP decreased LV end-diastolic pressure by a peak of 15% while slightly increasing LV stroke work compared with decreases of more than 60% and 50% with the pVAD, respectively. The pVAD also demonstrated increased coronary perfusion and systemic pressure gradients in comparison to the IABP. Combined support with VA-ECMO and pVAD improves cardiovascular state in comparison to IABP.

2.
Biomaterials ; 260: 120337, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32937269

RESUMO

Paclitaxel coated balloon catheters (PCB) were developed as a polymer-free non-implantable alternative to drug eluting stents, delivering similar drug payloads in a matter of minutes. While PCB have shown efficacy in treating peripheral arterial disease in certain patient groups, restenosis rates remain high and there is no class effect. To help further optimize these devices, we developed a scanning electron microscopy (SEM) imaging technique and computational modeling approach that provide insights into the coating micromorphology dependence of in vivo drug transfer and retention. PCBs coated with amorphous/flaky or microneedle coatings were inflated for 60 sec in porcine femoral arteries. Animals were euthanized at 0.5, 24 and 72 h and treated arteries processed for SEM to image endoluminal coating distribution followed by paclitaxel quantification by mass spectrometry (MS). Endoluminal surfaces exhibited sparse coating patches at 0.5 h, predominantly protruding (13.71 vs 0.59%, P < 0.001), with similar micro-morphologies to nominal PCB surfaces. Microneedle coating covered a 1.5-fold endoluminal area (16.1 vs 10.7%, P = 0.0035) owing to higher proximal and distal delivery, and achieved 1.5-fold tissue concentrations by MS (1933 vs 1298 µg/g, P = 0.1745) compared to amorphous/flaky coating. Acute longitudinal coating distribution tracked computationally predicted microindentation pressure gradients (r = 0.9, P < 0.001), with superior transfer of the microneedle coatings attributed to their amplification of angioplasty contact pressures. By 24 h, paclitaxel concentration and coated tissue areas both declined by >93% even as nonprotruding coating levels were stable between 0.5 and 72 h, and 2.7-fold higher for microneedle vs flaky coating (0.64 vs 0.24%, P = 0.0195). Tissue retained paclitaxel concentrations at 24-72 h trended 1.7-fold higher post treatment with microneedle coating compared to the amorphous/flaky coating (69.9 vs 39.9 µg/g, P = 0.066). Thus, balloon based drug delivery is critically dependent on coating micromorphologies, with superior performance exhibited by micromorphologies that amplify angioplasty pressures.


Assuntos
Stents Farmacológicos , Paclitaxel , Angioplastia , Animais , Materiais Revestidos Biocompatíveis , Excipientes , Artéria Femoral , Humanos , Suínos , Resultado do Tratamento
3.
Transl Res ; 213: 100-111, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31415732

RESUMO

This study sought to evaluate perisplenic artery nerve distribution and the feasibility of splenic artery denervation (SDN). The NEXION radiofrequency catheter was used to perform SDN in healthy and inflammatory arthritis pigs. Splenic artery anatomy, nerve distribution, and splenic norepinephrine (NEPI) levels were evaluated before and after SDN. Perisplenic artery nerves were primarily distributed within 2.5 mm of the arterial lumen and were largely sympathetic on the basis of tyrosine hydroxylase expression. The pancreas, tended to be circumferentially positioned around the proximal splenic artery, typically >2.5 mm from the lumen, ensuring that most of the nerves could be targeted without affecting this sensitive organ. The mid segment of the splenic artery was relatively free of contact with the adjacent pancreas. Splenic NEPI levels and nerve abundance followed a decreasing gradient from the proximal to distal splenic artery. SDN resulted in significant reductions in splenic NEPI levels at day 14 (60.7%, P = 0.024) in naïve pigs and day 45 (100%, P = 0.001) in inflammatory arthritis pigs. There was no significant effect of SDN on joint soft tissue injury or circulating inflammatory markers in the inflammatory arthritis model. The majority of perisplenic arterial nerves are within close proximity of the lumen and are primarily sympathetic efferent fibers. Nerves in the mid-segment may be the preferred SDN target given their proximity to the artery and paucity of periarterial off-target organs. SDN appears safe and effective at reducing splenic NEPI levels.


Assuntos
Denervação , Artéria Esplênica/anatomia & histologia , Artéria Esplênica/cirurgia , Animais , Artrite/patologia , Catéteres , Citocinas/metabolismo , Modelos Animais de Doenças , Estudos de Viabilidade , Inflamação/patologia , Masculino , Norepinefrina/metabolismo , Suínos
4.
Hypertension ; 74(3): 546-554, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31303108

RESUMO

Radiofrequency renal denervation is under investigation for treatment of hypertension with variable success. We developed preclinical models to examine the dependence of ablation biomarkers on renal denervation treatment parameters and anatomic variables. One hundred twenty-nine porcine renal arteries were denervated with an irrigated radiofrequency catheter with multiple helically arrayed electrodes. Nerve effects and ablation geometries at 7 days were characterized histomorphometrically and correlated with associated renal norepinephrine levels. Norepinephrine exhibited a threshold dependence on the percentage of affected nerves across the range of treatment durations (30-60 s) and power set points (6-20 W). For 15 W/30 s treatments, norepinephrine reduction and percentage of affected nerves tracked with number of electrode treatments, confirming additive effects of helically staggered ablations. Threshold effects were only attained when ≥4 electrodes were powered. Histomorphometry and computational modeling both illustrated that radiofrequency treatments directed at large neighboring veins resulted in subaverage ablation areas and, therefore, contributed suboptimally to efficacy. Account for measured nerve distribution patterns and the annular geometry of the artery revealed that, regardless of treatment variables, total ablation area and circumferential coverage were the prime determinants of renal denervation efficacy, with increased efficacy at smaller diameters.


Assuntos
Ablação por Cateter/métodos , Hipertensão/cirurgia , Rim/inervação , Norepinefrina/sangue , Artéria Renal/cirurgia , Simpatectomia/métodos , Animais , Biópsia por Agulha , Modelos Animais de Doenças , Eletrodos , Feminino , Humanos , Hipertensão/fisiopatologia , Imuno-Histoquímica , Masculino , Distribuição Aleatória , Valores de Referência , Suínos , Resultado do Tratamento
5.
EuroIntervention ; 11(12): 1435-41, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25735934

RESUMO

AIMS: We sought to evaluate the incidence of embolic material in porcine brains following vascular interventions using hydrophilic-coated sheaths. METHODS AND RESULTS: A new self-expanding stent and delivery system (SDS) was deployed through a hydrophilic-coated (Flexor Ansel; Cook Medical, Bloomington, IN, USA) guiding sheath into the iliac and/or carotid arteries of 23 anaesthetised Yucatan mini swine. The animals were euthanised at three, 30, 90 and 180 days and their brains were removed for histological analysis. In an additional single control animal, the guiding sheath was advanced but no SDS was deployed. Advancement of the coated guiding sheath with or without the SDS was associated with frequent foreign material in the arterioles of the brain. The embolic material was amorphous, non-refractile, non-crystalline, non-birefringent and typically lightly basophilic with a slightly stippled appearance on haematoxylin and eosin (H&E) stain. Material was observed at all time points involving 54% of all study animals (i.e., test and control) and in vitro after incubation in 0.9% saline. CONCLUSIONS: The hydrophilic coating on a clinically used guiding sheath readily avulses and embolises to the brain during deployment in a porcine model. Further documentation of this effect and monitoring in clinical scenarios are warranted.


Assuntos
Artérias Carótidas , Cateterismo Periférico/instrumentação , Materiais Revestidos Biocompatíveis , Procedimentos Endovasculares/instrumentação , Falha de Equipamento , Migração de Corpo Estranho/etiologia , Artéria Ilíaca , Embolia Intracraniana/etiologia , Dispositivos de Acesso Vascular , Animais , Encéfalo/patologia , Cateterismo Periférico/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Desenho de Equipamento , Migração de Corpo Estranho/patologia , Interações Hidrofóbicas e Hidrofílicas , Embolia Intracraniana/patologia , Stents , Suínos , Porco Miniatura , Fatores de Tempo
6.
Sci Transl Med ; 7(285): 285ra65, 2015 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-25925684

RESUMO

Renal denervation (RDN) is a treatment option for patients with hypertension resistant to conventional therapy. Clinical trials have demonstrated variable benefit. To understand the determinants of successful clinical response to this treatment, we integrated porcine and computational models of intravascular radiofrequency RDN. Controlled single-electrode denervation resulted in ablation zone geometries that varied in arc, area, and depth, depending on the composition of the adjacent tissue substructure. Computational simulations predicted that delivered power density was influenced by tissue substructure, and peaked at the conductivity discontinuities between soft fatty adventitia and water-rich tissues (media, lymph nodes, etc.), not at the electrode-tissue interface. Electrode irrigation protected arterial wall tissue adjacent to the electrode by clearing heat that diffuses from within the tissue, without altering periarterial ablation. Seven days after multielectrode treatments, renal norepinephrine and blood pressure were reduced. Blood pressure reductions were correlated with the size-weighted number of degenerative nerves, implying that the effectiveness of the treatment in decreasing hypertension depends on the extent of nerve injury and ablation, which in turn are determined by the tissue microanatomy at the electrode site. These results may explain the variable patient response to RDN and suggest a path to more robust outcomes.


Assuntos
Artérias/anatomia & histologia , Denervação , Hipertensão/terapia , Rim/inervação , Animais , Suínos
7.
Circ Cardiovasc Interv ; 8(1)2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25552566

RESUMO

BACKGROUND: The long-term efficacy of radiofrequency ablation of renal autonomic nerves has been proven in nonrandomized studies. However, long-term safety of the renal artery (RA) is of concern. The aim of our study was to determine if cooling during radiofrequency ablation preserved the RA while allowing equivalent nerve damage. METHODS AND RESULTS: A total of 9 swine (18 RAs) were included, and allocated to irrigated radiofrequency (n=6 RAs, temperature setting: 50°C), conventional radiofrequency (n=6 RAs, nonirrigated, temperature setting: 65°C), and high-temperature radiofrequency (n=6 RAs, nonirrigated, temperature setting: 90°C) groups. RAs were harvested at 10 days, serially sectioned from proximal to distal including perirenal tissues and examined after paraffin embedding, and staining with hematoxylin-eosin and Movat pentachrome. RAs and periarterial tissue including nerves were semiquantitatively assessed and scored. A total of 660 histological sections from 18 RAs were histologically examined by light microscopy. Arterial medial injury was significantly less in the irrigated radiofrequency group (depth of medial injury, circumferential involvement, and thinning) than that in the conventional radiofrequency group (P<0.001 for circumference; P=0.003 for thinning). Severe collagen damage such as denatured collagen was also significantly less in the irrigated compared with the conventional radiofrequency group (P<0.001). Nerve damage although not statistically different between the irrigated radiofrequency group and conventional radiofrequency group (P=0.36), there was a trend toward less nerve damage in the irrigated compared with conventional. Compared to conventional radiofrequency, circumferential medial damage in highest-temperature nonirrigated radiofrequency group was significantly greater (P<0.001). CONCLUSIONS: Saline irrigation significantly reduces arterial and periarterial tissue damage during radiofrequency ablation, and there is a trend toward less nerve damage.


Assuntos
Vias Autônomas/patologia , Ablação por Cateter , Rim/inervação , Complicações Pós-Operatórias/patologia , Artéria Renal/patologia , Lesões dos Tecidos Moles/patologia , Temperatura , Animais , Vias Autônomas/efeitos da radiação , Colágeno/metabolismo , Humanos , Rim/efeitos da radiação , Modelos Animais , Artéria Renal/efeitos da radiação , Lesões dos Tecidos Moles/etiologia , Suínos , Irrigação Terapêutica , Fatores de Tempo
8.
J Am Coll Cardiol ; 64(11): 1079-87, 2014 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-25212640

RESUMO

BACKGROUND: Renal denervation is a new interventional approach to treat hypertension with variable results. OBJECTIVES: The purpose of this study was to correlate response to endovascular radiofrequency ablation of renal arteries with nerve and ganglia distributions. We examined how renal neural network anatomy affected treatment efficacy. METHODS: A multielectrode radiofrequency catheter (15 W/60 s) treated 8 renal arteries (group 1). Arteries and kidneys were harvested 7 days post-treatment. Renal norepinephrine (NEPI) levels were correlated with ablation zone geometries and neural injury. Nerve and ganglion distributions and sizes were quantified at discrete distances from the aorta and were compared with 16 control arteries (group 2). RESULTS: Nerve and ganglia distributions varied with distance from the aorta (p < 0.001). A total of 75% of nerves fell within a circumferential area of 9.3, 6.3, and 3.4 mm of the lumen and 0.3, 3.0, and 6.0 mm from the aorta. Efficacy (NEPI 37 ng/g) was observed in only 1 of 8 treated arteries where ablation involved all 4 quadrants, reached a depth of 9.1 mm, and affected 50% of nerves. In 7 treated arteries, NEPI levels remained at baseline values (620 to 991 ng/g), ≤20% of the nerves were affected, and the ablation areas were smaller (16.2 ± 10.9 mm(2)) and present in only 1 to 2 quadrants at maximal depths of 3.8 ± 2.7 mm. CONCLUSIONS: Renal denervation procedures that do not account for asymmetries in renal periarterial nerve and ganglia distribution may miss targets and fall below the critical threshold for effect. This phenomenon is most acute in the ostium but holds throughout the renal artery, which requires further definition.


Assuntos
Ablação por Cateter , Procedimentos Endovasculares , Artéria Renal/inervação , Artéria Renal/cirurgia , Simpatectomia , Animais , Masculino , Suínos , Resultado do Tratamento
9.
J Invasive Cardiol ; 24(11): 560-8, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23117309

RESUMO

BACKGROUND: Novel vascular scaffolds aim at equipoise between safety and efficacy. Intravascular optical coherence tomography (OCT) allows in-vivo serial assessment of stent-vessel interactions with high resolution and frequent sampling and may complement histology assessment. We investigated the vascular response to a novel absorbable coating sirolimus-eluting stent (AC-SES) by means of serial OCT and histology evaluation in a porcine model. METHODS: One AC-SES and one bare-metal stent (BMS) were implanted in separate coronary arteries of three Yucatan mini-swine. Serial OCT was performed post procedure and at 3-, 28-, 90-, and 180-day follow-up. Normalized optical density (NOD) was used for the assessment of tissue response over time. Histological evaluation was performed at day 180. RESULTS: A total of 6408 stent struts were analyzed. OCT revealed 100% of struts covered at 28 days, and a significant difference in NOD from 3 to 28 days (0.64 ± 0.07 vs 0.71 ± 0.05, respectively; P<.001) in the AC-SES group. Neointimal thickness was 0.14 ± 0.08 mm, 0.17 ± 0.11 mm, and 0.16 ± 0.09 mm in the AC-SES group and 0.18 ± 0.10 mm, 0.14 ± 0.09 mm, and 0.10 ± 0.08 mm in the BMS group, while rates of uncovered struts were 0%, 0%, and 3.1% and 1.4%, 7.8%, and 21.5%, respectively, at 28, 90, and 180 days. Minimal inflammation and a mature endothelialization were demonstrated in both groups by histology. CONCLUSION: OCT serial assessment of vascular response suggested NIH maturation 28 days following AC-SES implantation in pigs. These findings, coupled with histological demonstration of low inflammation scores and complete endothelial coverage as measured at 180 days, suggest a satisfactory healing response to AC-SES.


Assuntos
Implantes Absorvíveis , Vasos Coronários/patologia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo , Tomografia de Coerência Óptica , Animais , Angiografia Coronária , Reestenose Coronária/patologia , Reestenose Coronária/prevenção & controle , Vasos Coronários/diagnóstico por imagem , Modelos Animais de Doenças , Endotélio Vascular/patologia , Seguimentos , Neointima/patologia , Intervenção Coronária Percutânea/métodos , Suínos , Porco Miniatura , Fatores de Tempo
10.
J Heart Lung Transplant ; 29(4): 479-86, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20036161

RESUMO

BACKGROUND: Endothelial cells (ECs) embedded within 3-dimensional matrices (MEEC) control lumenal inflammation and intimal hyperplasia when placed in the vascular adventitia. Matrix embedding alters endothelial immunogenicity in vitro. T-helper (Th) cell-driven host immunity is an impediment of allogeneic grafts. We aimed to identify if modulation of Th balance would affect immune compatibility and endothelial regulation of vascular repair in vivo. METHODS: Pigs (n = 4/group) underwent carotid artery balloon injury and were left untreated (Group 1) or received perivascular porcine MEEC implants (Group 2), 12 days of cyclosporine A (CsA; Group 3), or MEEC and CsA (Group 4). Host immune reactivity was analyzed after 28 and 90 days. RESULTS: MEEC treatment induced formation of EC-specific immunoglobulin (Ig) G(1) antibodies (41 +/- 6 mean fluorescence intensity [MFI]) and differentiation of host splenocytes into Th2, but not Th1, cytokine-producing cells (interleukin [IL]-4, 242 +/- 102; IL-10, 273 +/- 114 number of spots). Concomitant CsA therapy reduced IgG(1) antibody frequency (25 +/- 2 MFI; p < 0.02) and Th2-cytokine producing splenocytes upon MEEC treatment (IL-4, 157 +/- 19; IL-10, 124 +/- 26 number of spots; p < 0.05). MEECs inhibited luminal occlusion 28 and 90 days after balloon injury (12 +/- 7%) vs untreated controls (68 +/- 14%; p < 0.001) but to a lesser extent with concomitant CsA treatment (34 +/- 13%; p < 0.02 vs Group 2). CONCLUSIONS: MEECs do not induce a significant Th1-driven immune response but do enhance differentiation of splenocytes into cells producing Th2 cytokine. Reduction in this Th2 response reduces the vasoregulatory effects of allogeneic ECs after injury.


Assuntos
Lesões das Artérias Carótidas/fisiopatologia , Lesões das Artérias Carótidas/terapia , Transplante de Células/métodos , Endotélio Vascular/transplante , Células Th2/fisiologia , Animais , Lesões das Artérias Carótidas/metabolismo , Ciclosporina/uso terapêutico , Endotélio Vascular/citologia , Imunoglobulina G/metabolismo , Imunossupressores/uso terapêutico , Interleucina-4/metabolismo , Modelos Animais , Baço/citologia , Suínos , Transplante Homólogo
SELEÇÃO DE REFERÊNCIAS