Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
BMC Musculoskelet Disord ; 25(1): 449, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844899

RESUMO

BACKGROUND: Patient-specific aiming devices (PSAD) may improve precision and accuracy of glenoid component positioning in total shoulder arthroplasty, especially in degenerative glenoids. The aim of this study was to compare precision and accuracy of guide wire positioning into different glenoid models using a PSAD versus a standard guide. METHODS: Three experienced shoulder surgeons inserted 2.5 mm K-wires into polyurethane cast glenoid models of type Walch A, B and C (in total 180 models). Every surgeon placed guide wires into 10 glenoids of each type with a standard guide by DePuy Synthes in group (I) and with a PSAD in group (II). Deviation from planned version, inclination and entry point was measured, as well as investigation of a possible learning curve. RESULTS: Maximal deviation in version in B- and C-glenoids in (I) was 20.3° versus 4.8° in (II) (p < 0.001) and in inclination was 20.0° in (I) versus 3.7° in (II) (p < 0.001). For B-glenoid, more than 50% of the guide wires in (I) had a version deviation between 11.9° and 20.3° compared to ≤ 2.2° in (II) (p < 0.001). 50% of B- and C-glenoids in (I) showed a median inclination deviation of 4.6° (0.0°-20.0°; p < 0.001) versus 1.8° (0.0°-4.0°; p < 0.001) in (II). Deviation from the entry point was always less than 5.0 mm when using PSAD compared to a maximum of 7.7 mm with the standard guide and was most pronounced in type C (p < 0.001). CONCLUSION: PSAD enhance precision and accuracy of guide wire placement particularly for deformed B and C type glenoids compared to a standard guide in vitro. There was no learning curve for PSAD. However, findings of this study cannot be directly translated to the clinical reality and require further corroboration.


Assuntos
Artroplastia do Ombro , Curva de Aprendizado , Humanos , Artroplastia do Ombro/métodos , Artroplastia do Ombro/instrumentação , Fios Ortopédicos , Cavidade Glenoide/cirurgia , Modelos Anatômicos , Articulação do Ombro/cirurgia
2.
ACS Biomater Sci Eng ; 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38839046

RESUMO

Vertebroplasty is a minimally invasive surgical procedure used to treat vertebral fractures, which conventionally involves injecting poly(methyl methacrylate) (PMMA) bone cement into the fractured vertebra. A common risk associated with vertebroplasty is cement leaking out of the vertebra during the injection, which may occur due to a lack of understanding of the complex flow behavior. Therefore, experiments to quantify the cement's flow properties are necessary for understanding and proper handling of the bone cement. In this study, we aimed to characterize the behavior of PMMA bone cement in its curing stages to obtain parameters that govern the flow behavior during injection. We used rotational and oscillatory rheometry for our measurements, as well as a custom-made injector setup that replicated a typical vertebroplasty setting. Our results showed that the complex viscoelastic behavior of bone cement is significantly affected by deformations and temperature. We found that the results from rotational tests, often used for characterizing the bone cement, are susceptible to measurement artifacts caused by wall slip and "ridge"-like formations in the test sample. We also found the Cox-Merz rule to be conditionally valid, which affects the use of oscillatory tests to obtain the shear-thinning characteristics of bone cement. Our findings identify important differences in the measured flow behavior of PMMA bone cement when assessed by different rheological methods, an understanding that is crucial for its risk-free usage in downstream medical applications.

3.
Arch Osteoporos ; 16(1): 33, 2021 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-33594610

RESUMO

Cortical thickness determined at the humerus can serve as an easy and reliable screening tool to predict the local bone status when quantitative bone mineral density (BMD) measurements are not available. It can therefore serve as a rapid screening tool in fragility fractures to identify patients requiring further diagnostic or osteoporosis treatment. INTRODUCTION: Quantitative bone mineral density (BMD) of the humerus is difficult to determine but relevant for osteoporosis and fracture treatment. Dual-energy X-ray absorptiometry (DXA) of the femur and lumbar spine overestimates the humeral BMD and is not ubiquitously available. Therefore, this study evaluated whether the cortical bone thickness (CBT) of the humerus or DXA of the forearm is able to predict humeral BMD. METHODS: Humeral BMD of 54 upper cadaver extremities (22 pairs, 10 single) (19-90 years) was determined by high-resolution peripheral-quantitative-computed-tomography (HR-pQCT) (volumetric BMD (vBMD)) and DXA (areal BMD (aBMD)) of the proximal humerus and distal forearm. Average and gauge cortical bone thickness (CBTavg/ CBTg) of the humeral diaphysis was determined from standard radiographs (XR) and computed-tomography (CT) and compared to the humeral BMD. Pearson (r) and intraclass-correlation-coefficients (ICC) were used to compare results and rater-reliability. RESULTS: CBTavg from XR strongly correlated with the humeral BMD (r = 0.78 aBMD (DXA) and r = 0.64 vBMD (HR-pQCT) (p < 0.0001)). The CBTg revealed a weaker correlation (r = 0.57 aBMD and r = 0.43 vBMD). CBT derived from XR strongly correlated to those from the CT (r = 0.82-0.90) and showed an excellent intra- and inter-rater correlation (ICC 0.79-0.92). Distal forearm aBMD correlated well with the humeral aBMD (DXA) (r = 0.77) and paired specimens highly correlated to the contralateral side (humerus r = 0.89, radius r = 0.97). CONCLUSIONS: The CBTavg can reliably be determined from standard radiographs and allows a good prediction of quantitative humeral bone mineral density (aBMD or vBMD) if measurements are not available. Furthermore, the distal forearm or the contralateral humerus can serve as a side to estimate the BMD if the ipsilateral side is impaired.


Assuntos
Densidade Óssea , Úmero , Absorciometria de Fóton , Osso Cortical , Humanos , Úmero/diagnóstico por imagem , Reprodutibilidade dos Testes
4.
J Anat ; 238(3): 669-678, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33084063

RESUMO

Cortical bone and its microstructure are crucial for bone strength, especially at the long bone diaphysis. However, it is still not well-defined how imaging procedures can be used as predictive tools for mechanical bone properties. This study evaluated the capability of several high-resolution imaging techniques to capture cortical bone morphology and assessed the correlation with the bone's mechanical properties. The microstructural properties (cortical thickness [Ct.Th], porosity [Ct.Po], area [Ct.Ar]) of 11 female tibial diaphysis (40-90 years) were evaluated by dual-energy X-ray absorptiometry (DXA), high-resolution peripheral-quantitative-computed-tomography (HR-pQCT), micro-CT (µCT) and histomorphometry. Stiffness and maximal torque to failure were determined by mechanical testing. T-Scores determined by DXA ranged from 0.6 to -5.6 and a lower T-Score was associated with a decrease in Ct.Th (p ≤ 0.001) while the Ct.Po (p ≤ 0.007) increased, and this relationship was independent of the imaging method. With decreasing T-Score, histology showed an increase in Ct.Po from the endosteal to the periosteal side (p = 0.001) and an exponential increase in the ratio of osteons at rest to those after remodelling. However, compared to histomorphometry, HR-pQCT and µCT underestimated Ct.Po and Ct.Th. A lower T-Score was also associated with significantly reduced stiffness (p = 0.031) and maximal torque (p = 0.006). Improving the accuracy of Ct.Po and Ct.Th did not improve prediction of the mechanical properties, which was most closely related to geometry (Ct.Ar). The ex-vivo evaluation of mechanical properties correlated with all imaging modalities, with Ct.Th and Ct.Po highly correlated with the T-Score of the tibial diaphysis. Cortical microstructural changes were underestimated with the lower resolution of HR-pQCT and µCT compared to the histological 'gold standard'. The increased accuracy did not result in an improved prediction for local bone strength in this study, which however might be related to the limited number of specimens and thus needs to be evaluated in a larger collective.


Assuntos
Osso Cortical/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Absorciometria de Fóton , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Diáfises/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Microtomografia por Raio-X
5.
Materials (Basel) ; 13(21)2020 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-33105759

RESUMO

Hydroxyapatite (HA) coatings have become very popular in uncemented total hip arthroplasty (THA). Analysis of retrievals and tissue samples from an HA-coated femoral stem, which failed within 14 months after THA, provides exceptional insights into the failure mechanism, as well as the process of osteointegration of such an implant. METHODS: Retrievals were photo-documented. Samples were examined by micro-computed tomography, X-ray diffraction (XRD) and embedded in polymethylmethacrylate for histology. RESULTS: The coating had partially delaminated. The sandblasted surface of the stem was partially polished by the delaminated HA coating, indicating failure before revision. In the tissue samples, the HA coating was well integrated by newly formed bone trabeculae. No adverse biological reaction was observed. XRD analysis showed that residues of the HA coating were still present and could clearly be differentiated from the surrounding bone. Preferential orientation of the HA crystallites could be identified within the newly formed bone, representing a potential mechanical weakness induced either by physiologic strain or by the coating. CONCLUSION: current HA coatings, relatively thick and made of high crystallinity HA, may be prone to delamination, as also seen in our study. Recent efforts have aimed towards thinner (<1 µm) coatings with nanocrystalline HA structures that possibly relate to lower delamination risks. However, the question arises if HA coatings are beneficial since sandblasted non-coated stems offer similar results without the risk of delamination. XRD not only permits differentiation between the HA from the coating and the HA of the ongrown bone, it also provides new insights into the microstructure of this newly formed bone.

6.
Dent Mater ; 36(3): 402-412, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31992485

RESUMO

OBJECTIVE: Titanium (Ti)- and Zirconia (ZrO2)-implants in mini pig maxillae were compared with respect to Ti/zirconium (Zr) release into the surrounding bone tissues, the resulting short term tissue responses and the potential toxicity. METHODS: Ti/Zr release from Ti- and ZrO2-implants in mini pig maxillae was determined with inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS). The spatial distribution of Ti and Zr in maxilla tissues near the implant surface was assessed with laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS). A histological analysis was performed to investigate the tissue responses after 12 weeks of implantation. The cytotoxicity and DNA damage of Ti particles and ZrO2 particles were studied with XTT and Comet assay. RESULTS: The mean Ti content in the bone adjacent to Ti-implants was 1.67 mg/kg-bone weight. The highest Ti content detected was 2.17 mg/kg-bone weight. The mean Zr content in the bone adjected to ZrO2-implants was 0.59 mg/kg-bone weight. The highest Zr content was 0.75 mg/kg-bone weight. The spatial distribution of the Ti and Zr in bone showed mainly a higher intensity of Ti and Zr close to the screw thread outer tip rather. Histological analysis indicated that near both implant-types signs of bone marrow fibrosis were present. EC50 of commercially available ZrO2-nanoparticles (NPs, <100 nm) and ZrO2-microparticles (MPs, <5 µm) was 13.96 mg/ml and 80.99 mg/ml, respectively. ZrO2-NPs and ZrO2-MPs can induce DNA damage at 70 µg/ml and 810 µg/ml, respectively. SIGNIFICANCE: After 12-weeks of implantation, increased concentrations of Ti and Zr can be detected in bone/tissues near Ti- and ZrO2-implants in mini pig maxillae. Ti content released from Ti-implants is two times higher than the Zr content released from ZrO2-implants. ZrO2-NPs showed lower cytotoxicity and DNA damage compared to results reported for Ti-NPs in human cells.


Assuntos
Implantes Dentários , Zircônio , Animais , Humanos , Maxila , Propriedades de Superfície , Suínos , Porco Miniatura , Titânio
7.
PLoS One ; 14(2): e0210402, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30707699

RESUMO

Orthopedic device-related infection (ODRI) is a potentially devastating complication arising from the colonization of the device with bacteria, such as Staphylococcus aureus. The aim of this study was to determine if intraoperative loading of a clinically approved calcium phosphate (CaP) coating with gentamicin can protect from ODRI in vivo. First, CaP-coated titanium aluminium niobium (TAN) discs were used to investigate the adsorption and release kinetics of gentamicin in vitro. Gentamicin loading and subsequent release from the coating were both rapid, with maximum loading occurring following one second of immersion, and >95% gentamicin released within 15 min in aqueous solution, respectively. Second, efficacy of the gentamicin-loaded CaP coating for preventing ODRI in vivo was investigated using a CaP-coated unicortical TAN screw implanted into the proximal tibia of skeletally mature female Wistar rats, following inoculation of the implant site with S. aureus. Gentamicin-loading prevented ODRI in 7/8 animals, whereas 9/9 of the non-gentamicin treated animals were infected after 7 days. In conclusion, gentamicin can be rapidly and simply loaded onto, and released from, CaP-based implant coatings, and this is an effective strategy for preventing peri-operative S. aureus-induced ODRI in vivo.


Assuntos
Fosfatos de Cálcio/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Gentamicinas/farmacologia , Cuidados Intraoperatórios , Infecções Estafilocócicas/prevenção & controle , Staphylococcus aureus/crescimento & desenvolvimento , Ligas/farmacologia , Animais , Parafusos Ósseos , Feminino , Nióbio/farmacologia , Ratos , Ratos Wistar , Tíbia/metabolismo , Tíbia/microbiologia , Tíbia/patologia
8.
J Biomed Mater Res B Appl Biomater ; 106(8): 2924-2931, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30199602

RESUMO

Infection associated with an implant is a complication feared in surgery, as it leads to loosening and dysfunction. This report documents an unexpected good bony integration of a porous tantalum shoulder prosthesis despite infection. A shoulder prosthesis with a porous tantalum glenoidal base plate was retrieved after 3 years of ongoing infection with Staphylococcus spp. Methyl-methacrylate embedded sections of the retrieved glenoidal component were analyzed by optical and scanning electron beam microscopy (SEM). Bone ongrowth and ingrowth were quantified. Bone had formed at the implant surface and within the open cell structure of the porous tantalum. The bone implant contact index was 32%. The bone ingrowth or relative bone area within the open structure was 8.2%, respectively 11.9% in the outer 50% of the thickness. Due to the section thickness, bone ongrowth could best be documented in SEM. Despite long-lasting and ongoing infection, the glenoidal base plate of the prosthesis showed good bony integration upon removal. The bone ingrowth into the porous tantalum was comparable to the values previously reported for the undersurface of retrieved proximal humerus resurfacing implants. Good integration of the implant however did not solve the problem of infection, and related morbidity. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 2924-2931, 2018.


Assuntos
Interface Osso-Implante , Próteses e Implantes/efeitos adversos , Prótese de Ombro/efeitos adversos , Infecções Estafilocócicas , Staphylococcus , Idoso , Interface Osso-Implante/microbiologia , Interface Osso-Implante/patologia , Feminino , Cavidade Glenoide/microbiologia , Cavidade Glenoide/patologia , Humanos , Úmero/microbiologia , Úmero/patologia , Infecções Estafilocócicas/microbiologia , Infecções Estafilocócicas/patologia , Titânio
9.
Am J Vet Res ; 79(9): 970-979, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30153050

RESUMO

OBJECTIVE To evaluate and compare surface and cross-sectional structure as well as localized electrochemical corrosion and ion release for cast stainless steel (SS) tibia plateau leveling osteotomy (TPLO) plates retrieved from dogs with and without osteosarcoma (OSA) and to compare these findings with similar variables for forged SS TPLO plates retrieved from dogs. SAMPLE 47 TPLO plates explanted from 45 client-owned dogs (22 cast plates from dogs with OSA, 22 cast plates from dogs without OSA, and 3 forged plates from dogs without OSA). PROCEDURES Histologic evaluations of tissue samples collected from implant sites at the time of plate retrieval were performed to confirm implant site tumor status of each dog. Surfaces and metallographic cross sections of retrieved plates were examined, and the microcell technique was used to obtain local electrochemical corrosion and ion release measurements. RESULTS Findings indicated that all cast SS plates demonstrated high spatial variability of their electrochemical surface properties and inhomogeneous superficial and cross-sectional composition, compared with forged plates. Greater metal ion release was observed in cast plates than in forged plates and in cast plates from dogs with OSA than in cast or forged from dogs without OSA. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that accumulation of metal ions from implants could be a trigger for neoplastic transformation in neighboring cells. Metal ion release caused by corrosion of implants that do not comply with recommended standards of the American Society for Testing and Materials International or the International Organization for Standardization could potentially place patients at increased risk of tumor development.


Assuntos
Neoplasias Ósseas/veterinária , Placas Ósseas/veterinária , Doenças do Cão/patologia , Osteossarcoma/veterinária , Osteotomia/veterinária , Animais , Corrosão , Estudos Transversais , Cães , Técnicas Eletroquímicas , Masculino , Teste de Materiais , Osteotomia/métodos , Estudos Retrospectivos , Aço Inoxidável , Propriedades de Superfície , Tíbia/cirurgia
10.
J Tissue Eng Regen Med ; 12(2): 321-329, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28486746

RESUMO

The ability to engineer scaffolds that resemble the transition between tissues would be beneficial to improve repair of complex organs, but has yet to be achieved. In order to mimic tissue organization, such constructs should present continuous gradients of geometry, stiffness and biochemical composition. Although the introduction of rapid prototyping or additive manufacturing techniques allows deposition of heterogeneous layers and shape control, the creation of surface chemical gradients has not been explored on three-dimensional (3D) scaffolds obtained through fused deposition modelling technique. Thus, the goal of this study was to introduce a gradient functionalization method in which a poly(ε-caprolactone) surface was first aminolysed and subsequently covered with collagen via carbodiimide reaction. The 2D constructs were characterized for their amine and collagen contents, wettability, surface topography and biofunctionality. Finally, chemical gradients were created in 3D printed scaffolds with controlled geometry and porosity. The combination of additive manufacturing and surface modification is a viable tool for the fabrication of 3D constructs with controlled structural and chemical gradients. These constructs can be employed for mimicking continuous tissue gradients for interface tissue engineering.


Assuntos
Colágeno/farmacologia , Poliésteres/farmacologia , Impressão Tridimensional , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Animais , Linhagem Celular Tumoral , Humanos , Ratos , Resistência à Tração , Microtomografia por Raio-X
11.
Calcif Tissue Int ; 101(3): 271-279, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28432379

RESUMO

Fractures of the proximal humerus are highly related to age and osteoporotic bone remodeling. Previous studies have highlighted the cortex as a major side of the bone loss, but the microstructural changes of the humerus have not been evaluated entirely. Sixty-four (n = 64) humeri of a representative collective (18-100 years) were scanned with high-resolution peripheral quantitative computed tomography (82 µm). Bone mineral density (BMD), trabecular bone volume fraction (Tb.BV/TV), cortical thickness (Ct.Th), and cortical porosity (Ct.Po) were determined with respect to four age groups. The BMD (r = -0.42), Ct.Th (r = 0.57), and Tb.BV/TV (r = 0.68) showed an age group-related decrease, while the Ct.Po increased (r = -0.55). The oldest group (80-100 years) revealed an extensively higher Ct.Po of +87% compared to the youngest group (18-44 years), while the Ct.Th and Tb.BV/TV were significantly lower by -35 and -49% (p < 0.05). The main cortical bone loss occurred after 65 years with the Ct.Th (-34%) and Tb.BV/TV (-40%) being clearly lower and the Ct.Po (+93%) clearly higher compared to the youngest group. In summary, osteoporosis leads to an age-related higher Ct.Po and reduced Ct.Th at the humeral cortex of the surgical neck. The bone loss of the cortex predominantly occurs around the age of 65 years and is very likely to reduce the mechanical strength and highly increases the fracture risk.


Assuntos
Envelhecimento/patologia , Densidade Óssea , Osso Cortical/patologia , Úmero/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cadáver , Osso Cortical/diagnóstico por imagem , Estudos Transversais , Feminino , Humanos , Úmero/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Porosidade , Tomografia Computadorizada por Raios X , Adulto Jovem
12.
Arch Orthop Trauma Surg ; 136(9): 1331-1335, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27450194

RESUMO

INTRODUCTION: Primary press fit and secondary osteointegration is a precondition for component anchoring in articular surface replacements, also in the case of proximal interphalangeal (PIP) joint. Nevertheless, many existing prostheses for the PIP joint have failed to show sufficient osteointegration. CapFlex-PIP(©) implant is a modular metal-polyethylene surface replacement for the PIP joint consisting of a proximal and distal component each having a titanium pore backside, which allows secondary osteointegration at the bone-implant interface. To evaluate osseous integration of this implant, we report a histological analysis of an explantation of a CapFlex-PIP(©) finger implant. CASE PRESENTATION: We present a case of a removed CapFlex-PIP(©) implant due to a soft tissue complication in an 84-year-old woman. The patient received bisphosphonate medication as treatment for osteoporosis. For the histological analysis, the bone-implant contact (BIC) was measured on all stained sections using a Zeiss Axioplan microscope. The summated BIC was 40.7 % for the proximal component and 46.5 % for the distal component of the implant. Histology showed that the implant was in direct contact with the bone at various locations, with no signs of wear or degradation. CONCLUSIONS: This case demonstrates successful osteointegration of the CapFlex-PIP(©) implant. Both components of the investigated implant show osseous integration to an extent which is comparable to that of other load-bearing and articulating implants at different locations in the human body.


Assuntos
Artroplastia de Substituição de Dedo , Articulações dos Dedos/cirurgia , Prótese Articular , Osseointegração , Idoso de 80 Anos ou mais , Feminino , Humanos , Osteoartrite/cirurgia , Polietileno , Titânio
13.
J Orthop Translat ; 5: 57-68, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30035075

RESUMO

BACKGROUND/OBJECTIVE: Advanced synthetic biomaterials that are able to reduce or replace the need for autologous bone transplantation are still a major clinical need in orthopaedics, dentistry, and trauma. Key requirements for improved bone substitutes are optimal handling properties, ability to fill defects of irregular shape, and capacity for delivering osteoinductive stimuli. MATERIALS AND METHODS: In this study, we targeted these requirements by preparing a new composite of ß-tricalcium phosphate (TCP) and a thermoresponsive hyaluronan (HA) hydrogel. Dissolution properties of the composite as a function of the particle size and polymeric phase molecular weight and concentration were analysed to identify the best compositions. RESULTS: Owing to its amphiphilic character, the composite was able to provide controlled release of both recombinant human bone morphogenetic protein-2 and dexamethasone, selected as models for a biologic and a small hydrophobic molecule, respectively. CONCLUSION: The TCP-thermoresponsive HA hydrogel composite developed in this work can be used for preparing synthetic bone substitutes in the form of injectable or mouldable pastes and can be supplemented with small hydrophobic molecules or biologics for improved osteoinductivity.

14.
Medicine (Baltimore) ; 94(51): e2043, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26705200

RESUMO

Osteoporosis is a systemic disorder predominantly affecting postmenopausal women but also men at an advanced age. Both genders may suffer from low-energy fractures of, for example, the proximal humerus when reduction of the bone stock or/and quality has occurred.The aim of the current study was to compare the amount of bone in typical fracture zones of the proximal humerus in osteoporotic and non-osteoporotic individuals.The amount of bone in the proximal humerus was determined histomorphometrically in frontal plane sections. The donor bones were allocated to normal and osteoporotic groups using the T-score from distal radius DXA measurements of the same extremities. The T-score evaluation was done according to WHO criteria. Regional thickness of the subchondral plate and the metaphyseal cortical bone were measured using interactive image analysis.At all measured locations the amount of cancellous bone was significantly lower in individuals from the osteoporotic group compared to the non-osteoporotic one. The osteoporotic group showed more significant differences between regions of the same bone than the non-osteoporotic group. In both groups the subchondral cancellous bone and the subchondral plate were least affected by bone loss. In contrast, the medial metaphyseal region in the osteoporotic group exhibited higher bone loss in comparison to the lateral side.This observation may explain prevailing fracture patterns, which frequently involve compression fractures and certainly has an influence on the stability of implants placed in this medial region. It should be considered when planning the anchoring of osteosynthesis materials in osteoporotic patients with fractures of the proximal humerus.


Assuntos
Fraturas Ósseas/patologia , Úmero/patologia , Osteoporose/patologia , Absorciometria de Fóton , Adulto , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
15.
PLoS One ; 10(10): e0140541, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26509573

RESUMO

BACKGROUND: Conflicting reports in the literature have raised the question whether radial extracorporeal shock wave therapy (rESWT) devices and vibrating massage devices have similar energy signatures and, hence, cause similar bioeffects in treated tissues. METHODS AND FINDINGS: We used laser fiber optic probe hydrophone (FOPH) measurements, high-speed imaging and x-ray film analysis to compare fundamental elements of the energy signatures of two rESWT devices (Swiss DolorClast; Electro Medical Systems, Nyon, Switzerland; D-Actor 200; Storz Medical, Tägerwillen, Switzerland) and a vibrating massage device (Vibracare; G5/General Physiotherapy, Inc., Earth City, MO, USA). To assert potential bioeffects of these treatment modalities we investigated the influence of rESWT and vibrating massage devices on locomotion ability of Caenorhabditis elegans (C. elegans) worms. RESULTS: FOPH measurements demonstrated that both rESWT devices generated acoustic waves with comparable pressure and energy flux density. Furthermore, both rESWT devices generated cavitation as evidenced by high-speed imaging and caused mechanical damage on the surface of x-ray film. The vibrating massage device did not show any of these characteristics. Moreover, locomotion ability of C. elegans was statistically significantly impaired after exposure to radial extracorporeal shock waves but was unaffected after exposure of worms to the vibrating massage device. CONCLUSIONS: The results of the present study indicate that both energy signature and bioeffects of rESWT devices are fundamentally different from those of vibrating massage devices. CLINICAL RELEVANCE: Prior ESWT studies have shown that tissues treated with sufficient quantities of acoustic sound waves undergo cavitation build-up, mechanotransduction, and ultimately, a biological alteration that "kick-starts" the healing response. Due to their different treatment indications and contra-indications rESWT devices cannot be equated to vibrating massage devices and should be used with due caution in clinical practice.


Assuntos
Caenorhabditis elegans/fisiologia , Ondas de Choque de Alta Energia , Animais , Tecnologia de Fibra Óptica , Locomoção/efeitos da radiação , Pressão , Som , Fatores de Tempo , Filme para Raios X
16.
J Orthop Res ; 33(9): 1382-90, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25808101

RESUMO

Cementless-surface-replacement-arthroplasty (CSRA) of the shoulder aims for functional joint restoration with minimal bone loss. Good clinical results have been reported, but due to the radiopaque metal shell no data is available on the structure, osseous integration, and bone stock under the implant. 14 hemi-CSRAs (4 manufacturers) with two geometries (crown [n = 7]/ stem [n = 7] fixation) were retrieved from patients undergoing revision due to glenoidal erosion. Histological sections cutting through the implant centre and bone were analysed. Quantitative histomorphometry evaluated the bone-implant-contact and compared the bone-area to native humeral retrievals (n = 7). The bone-implant-interface was further assessed by scanning-electron-microscopy (SEM) and energy-dispersive-x-ray (EDX). Qualitative histology revealed a reduced and inhomogeneous bone stock. Obvious signs of stress shielding were observed with bone predominantly visible at the stem and implant rim. Quantitative histomorphometry confirmed the significantly reduced bone-area (9.2 ± 3.9% [crown 9.9 ± 4.3%, stem 8.6 ± 3.6%]) compared to native humeri (21.2 ± 9.1%; p < 0.05). Bone-implant-contact was 20.5 ± 5.8% (crown 21.8 ± 6.2%, stem 19.2 ± 5.6%) which was confirmed by SEM and EDX. Altogether, CRSA shows satisfactory bone ingrowth at the interface suggesting sufficient primary stability to allow osseous integration. However, clear signs of stress shielding with an inhomogeneous and reduced bone stock were observed. The impact on the long-term-results is unclear requiring further investigation.


Assuntos
Artroplastia de Substituição/métodos , Prótese de Quadril , Cabeça do Úmero/fisiologia , Úmero/cirurgia , Articulação do Ombro/cirurgia , Idoso , Reabsorção Óssea , Humanos , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Osseointegração , Próteses e Implantes , Desenho de Prótese/métodos , Resultado do Tratamento , Raios X
17.
Clin Biomech (Bristol, Avon) ; 30(3): 243-7, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25686676

RESUMO

BACKGROUND: Rotator cuff tears are of increasing clinical impact in the physically active elderly patients. Recent research revealed, that a high percentage of these patients present with significant loss of bone mineral density at the insertion site of the rotator cuff, thereby compromising suture anchorage for operative repair. We therefore hypothesized that augmentation of suture anchors improves biomechanical properties in low bone quality. METHODS: 28 osteoporotic humeral heads were included in this biomechanical study. Bone quality at the anchor insertion sites (group 1: posterior-medial; group 2: anterior-lateral) within the greater tuberosity was analyzed using HR-pQCT (voxel size: 82µm). Anchor positions of identical quality were then randomized to either conventional screw anchorage or polymethylmethacrylat augmented screw anchorage. All anchors were cyclically ramp-loaded until pullout. FINDINGS: Pullout strength accounted for 226N in group I for conventional anchorage and for 332N in augmented technique. In group 2 (anterior-lateral) the pullout strength was 209N (conventional) and 304N (augmented). Pull-out strength of augmented screw anchors was significantly higher in both groups (p<0.05). INTERPRETATION: Compared to conventional insertion techniques, the cement augmentation technique increases the pullout strength of suture anchors in low bone quality significantly. Cement augmentation could therefore be a helpful tool for improved suture anchor stability, especially in locations of low bone quality.


Assuntos
Cabeça do Úmero/cirurgia , Osteoporose/cirurgia , Âncoras de Sutura , Idoso , Fenômenos Biomecânicos , Cimentos Ósseos , Parafusos Ósseos , Cadáver , Feminino , Humanos , Cabeça do Úmero/fisiopatologia , Masculino , Osteoporose/fisiopatologia , Polimetil Metacrilato , Manguito Rotador/cirurgia , Resistência à Tração
18.
Spine J ; 15(6): 1325-31, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-24139866

RESUMO

BACKGROUND CONTEXT: The human iliolumbar ligament connects the transverse process of L5 to the iliac crest and contributes to lumbosacral stability and has been associated with low back pain. However, different opinions exist regarding the functional relevance of the ligament. PURPOSE: In the present study, we analyze the regional molecular composition of the ligament extracellular matrix. STUDY DESIGN: Special attention is given to the attachment sites, to determine whether the ligament is subjected to a certain mechanical environment. METHODS: Iliolumbar ligament samples, extending from one enthesis to the other, were removed from 11 cadavers and fixed in methanol. Cryosections were immunolabeled with a panel of antibodies directed against collagens, glycosaminoglycans, proteoglycans, matrix proteins, and neurofilament. RESULTS: The mid-substance of the ligament labeled for all the molecules normally found in dense fibrous connective tissue including types I, III, and VI collagen, versican, dermatan -, chondroitin 4 -, and keratan sulfate. However, both entheses were fibrocartilaginous and labeled for type II collagen, aggrecan, and chondroitin 6- sulfate. A common feature was fat between the fiber bundles near the entheses. Occasionally this fat contained nerve fibers. CONCLUSIONS: The existence of fibrocartilaginous entheses suggests that the insertion sites of the ligament are subject to both tensile and compressive loading-probably because of insertional angle changes between ligament and bone during loading. Our findings support the suggestion that the iliolumbar ligament might play an important role in the stabilization of the lumbosacral junction.


Assuntos
Colágeno/metabolismo , Proteínas da Matriz Extracelular/metabolismo , Matriz Extracelular/metabolismo , Glicosaminoglicanos/metabolismo , Ligamentos Articulares/metabolismo , Proteoglicanas/metabolismo , Adolescente , Adulto , Agrecanas/metabolismo , Sulfatos de Condroitina , Colágeno Tipo II/metabolismo , Feminino , Humanos , Imuno-Histoquímica , Masculino , Pessoa de Meia-Idade , Adulto Jovem
19.
Arch Orthop Trauma Surg ; 133(3): 381-7, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23224427

RESUMO

PURPOSE: Rotator cuff (RC) repair-especially in the elderly population-is problematic since the patients suffer to a high extent from bone mineral density loss at the reattachment site. Therefore, the study was primarily driven by the question whether it is possible to reach more or qualitatively better cancellous bone and thus a more stable postoperative result if anchors with greater length are used for RC repair and/or the conventional anchors are screwed deeper into the bone. In anatomical terms, the question is raised whether cancellous bone is of better quality close to or far off the RC enthesis. METHODS: Axial HRqCT scans (X-tremeCT, Scanco Medical) of 36 human cadaveric humeral heads (75 ± 11 years) were performed to determine the ratio of bone volume to total volume (BV/TV), trabecular thickness (Trab Th), number of trabecles (Trab N), trabecular separation (Trab Sp) as well as non-metric indices such as connectivity density (Conn Dens) and structure model index (SMI). Within the greater tuberosity (GT), 6 volumes of interest (VOI) (A1, B1, C1, A2, B2, C2), in the lesser tuberosity (LT) 2 VOIs (D1, D2) and one control VOI in the subchondral bone were set. The analyzed bone cylinder of each VOI was divided into a superficial and a deep portion. RESULTS: The parameters BV/TV, Trab N, Trab Th and Conn Dens in all volumes of the GT and LT revealed higher values in the superficial portion reaching different levels of significance (p < 0.001/<0.05). The only parameter presenting a higher value in the deep portion was Trab Sp, but this was the case for all GT and LT regions. Interestingly, the difference between the superficial and deep portion reached significance for the non-metric parameter SMI in no volume of the GT/LT, although the higher values were found superficially. CONCLUSIONS: Our data show that cancellous bone presents with decreasing bone quality when analyzing increasingly deeper portions of the bone cylinders of the GT and LT starting at the articular surface. This information seems to be crucial for shoulder surgeons, especially when treating elderly patients. Our results clearly prove that screwing in anchors to a deeper extent will not improve stability, since the deeper bone stock is of worse quality.


Assuntos
Úmero/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Lesões do Manguito Rotador , Manguito Rotador/cirurgia , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Cadáver , Feminino , Humanos , Úmero/cirurgia , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Osteoporose/cirurgia , Tomografia Computadorizada por Raios X
20.
BMC Musculoskelet Disord ; 13: 221, 2012 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-23148627

RESUMO

BACKGROUND: Age-dependent trabecular changes of the humeral head might weaken the fixation of suture anchors used for rotator cuff (RC) repair. This might lead to suture anchor loosening and thus compromise the integrity of the repair. The aim of this study was to analyze whether the trabecular microstructure within the RC footprint is influenced by age, gender or handedness. METHODS: Axial HR-pQCT scans (Scanco Medical) of 64 freshly frozen cadaveric human humeral head specimens (age 72.3 ± 17.4 years) were analyzed to determine the bone volume-to-total volume ratio (BV/TV), trabecular thickness (Trab Th), trabecular number (Trab N) and connectivity density (Conn Dens). Within the RC footprint, 2 volumes of interest (VOI), posteromedial (PM) and anterolateral (AL) and one control VOI in the subarticular bone (SC) were set. RESULTS: The highest BV/TV was found in SC: 0.22 ± 0.06% vs. PM: 0.04 ± 0.05% vs. AL: 0.02 ± 0.04%; p < 0.05. Trab Th accounted for 0.26 ± 0.05 µm in SC, 0.23 ± 0.09 µm in AL and 0.21 ± 0.05 µm in PM. In parallel, Trab N and Conn Dens were found to be the highest in SC. Gender analysis yielded higher values for BV/TV, Trab Th, Trab N and Conn Dens for PM in males compared to females (p < 0.05). There were no significant findings when comparing both sides. We furthermore found a strong inverse correlation between age and BV/TV, which was more pronounced in the female specimens (r = -0.72, p < 0.00001). CONCLUSIONS: The presented microarchitectural data allow for future subtle biomechanical testing comprising knowledge on age- and sex-related changes of the tuberosities of the humeral head. Furthermore, the insights on the trabecular structure of the humeral head of the elderly may lead to the development of new fixation materials in bone with inferior bone quality.


Assuntos
Envelhecimento/fisiologia , Densidade Óssea/fisiologia , Cabeça do Úmero/diagnóstico por imagem , Cabeça do Úmero/fisiologia , Caracteres Sexuais , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...