Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Gastroenterol Nurs ; 36(2): 106-11, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23549213

RESUMO

The purpose of this study was to examine bacterial growth in colonoscopes in a series of graduated shelf times. There is no conclusive evidence on the length of time colonoscopes can be safely stored before requiring redisinfection. Standards for processing scopes after use are described and supported by the professional organizations of gastroenterology and infection control; however, shelf life varies from 3 to 5 days and most recommendations are based on clinical consensus. In this study, four colonoscopes were used in a clinical procedure, underwent automated high-level disinfection with 2.6% buffered glutaraldehyde, and cultured after 3, 5, 7, 14, 21, 28, 42, and 56 days of shelf time. Two investigators collected all the cultures after interrater reliability was established. Cultures were processed in the microbiology laboratory. No medically significant growth was detected at any of the culture points. At Day 14 and Day 42, one of four scopes grew fewer than two colony-forming units of a medically insignificant bacterium. Using professional standards for high-level disinfection growth was suppressed for up to 8 weeks. Further evidence to assess fungal or viral growth is needed to be able to make suggestions for colonoscope shelf life.


Assuntos
Ar , Bactérias/crescimento & desenvolvimento , Colonoscópios/microbiologia , Desinfecção/normas , Contagem de Colônia Microbiana/métodos , Desinfecção/métodos , Contaminação de Equipamentos/prevenção & controle , Humanos , Indiana , Estudos Longitudinais , Estudos Prospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...