Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Proc SPIE Int Soc Opt Eng ; 9330: 933009, 2015 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-27041787

RESUMO

A beam-scanning microscope based on Lissajous trajectory imaging is described for achieving streaming 2D imaging with continuous frame rates up to 1.4 kHz. The microscope utilizes two fast-scan resonant mirrors to direct the optical beam on a circuitous trajectory through the field of view. By separating the full Lissajous trajectory time-domain data into sub-trajectories (partial, undersampled trajectories) effective frame-rates much higher than the repeat time of the Lissajous trajectory are achieved with many unsampled pixels present. A model-based image reconstruction (MBIR) 3D in-painting algorithm is then used to interpolate the missing data for the unsampled pixels to recover full images. The MBIR algorithm uses a maximum a posteriori estimation with a generalized Gaussian Markov random field prior model for image interpolation. Because images are acquired using photomultiplier tubes or photodiodes, parallelization for multi-channel imaging is straightforward. Preliminary results show that when combined with the MBIR in-painting algorithm, this technique has the ability to generate kHz frame rate images across 6 total dimensions of space, time, and polarization for SHG, TPEF, and confocal reflective birefringence data on a multimodal imaging platform for biomedical imaging. The use of a multi-channel data acquisition card allows for multimodal imaging with perfect image overlay. Image blur due to sample motion was also reduced by using higher frame rates.

2.
Opt Express ; 22(20): 24224-34, 2014 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-25321997

RESUMO

A simple beam-scanning optical design based on Lissajous trajectory imaging is described for achieving up to kHz frame-rate optical imaging on multiple simultaneous data acquisition channels. In brief, two fast-scan resonant mirrors direct the optical beam on a circuitous trajectory through the field of view, with the trajectory repeat-time given by the least common multiplier of the mirror periods. Dicing the raw time-domain data into sub-trajectories combined with model-based image reconstruction (MBIR) 3D in-painting algorithms allows for effective frame-rates much higher than the repeat time of the Lissajous trajectory. Since sub-trajectory and full-trajectory imaging are simply different methods of analyzing the same data, both high-frame rate images with relatively low resolution and low frame rate images with high resolution are simultaneously acquired. The optical hardware required to perform Lissajous imaging represents only a minor modification to established beam-scanning hardware, combined with additional control and data acquisition electronics. Preliminary studies based on laser transmittance imaging and polarization-dependent second harmonic generation microscopy support the viability of the approach both for detection of subtle changes in large signals and for trace-light detection of transient fluctuations.


Assuntos
Algoritmos , Diagnóstico por Imagem , Processamento de Imagem Assistida por Computador/métodos , Microscopia de Polarização/métodos , Modelos Teóricos , Imagens de Fantasmas , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...