1.
Indian J Plast Surg ; 57(2): 106-115, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38774736

RESUMO

Introduction Breast reconstruction has become integral part of breast cancer treatment. Deep inferior epigastric perforator (DIEP)-based flap is considered the gold standard in autologous breast reconstruction. Aims and Objectives The aim of this study was to evaluate the patient satisfaction and the incidence of complications in DIEP flaps in an Indian setup for breast reconstruction. Materials and Methods This is a prospective, nonrandomized study at a single institute-Manipal Hospitals, Old Airport Road, Bangalore. Eligible patients were women aged between 28 and 60 years with primary breast cancer requiring mastectomy and radiotherapy, who consented for DIEP flap reconstruction. Results The study includes subjects who had autologous breast reconstruction after mastectomy with DIEP flap between January 2019 and August 2021 that included 31 patients with a minimum follow-up of 2 years. Four flaps were turbocharged and 17 flaps were superdrained primarily. The average operative time for the whole procedure by adopting a two-team approach is 353.8 ± 43.793 minutes. About 94.1% patients had excellent aesthetic score results. Six patients developed mastectomy flap necrosis, one had fat necrosis that was managed conservatively, whereas one patient had donor site re-exploration for hematoma. We had no DIEP flap necrosis, seroma, flap site hematoma, or flap failure. Physical well-being module of Breast-Q indicated an average of 83 points, psychosocial well-being module indicated 80 points, whereas sexual scores reverted an average of 77 points. Among satisfaction module, aesthetic outcomes for breast showed an average of 94 points, whereas the donor site had 96 points. Satisfaction with information, surgeon, medical staff each gained more than 87 points. Conclusion Breast reconstruction with DIEP flap yields good aesthetic outcomes and quality of life in Indian population. The incidence of fat necrosis, flap and donor site complications is less over time and will enhance the patient satisfaction score further.

2.
J Indian Assoc Pediatr Surg ; 27(6): 760-763, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36714496

RESUMO

Acute graft-versus-host disease of the gastrointestinal tract (GI-aGVHD) is a rare condition, often requiring multiple laparotomies, ultimately leading to a burst abdomen. We report the successful use of a dermal regeneration template (DRT), combined with negative pressure wound therapy (NPWT) and skin grafts, to reconstruct the abdominal skin in an 11-year-old boy. The patient was a case of aplastic anemia, who underwent bone marrow transfers, the first of which failed and the second one was successful. He eventually developed gastrointestinal GVHD. Repeated laparotomies were done for recurrent intestinal obstruction. He also underwent resection anastomosis and end ileostomy, after which he developed an anterior abdominal wall defect due to a burst abdomen. After 12 months of management with multiple dressings, NPWT, and DRT, a stable coverage was achieved, without skin retraction. We report our experience in anterior abdominal wall reconstruction in a case of GI-aGVHD using DRT.

3.
Indian J Plast Surg ; 53(3): 377-380, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33402768

RESUMO

Background Indocyanine green (ICG) lymphangiography is being increasingly employed to assess the severity of lymphedema, locate the areas of patent linear lymphatics and dermal backflow and plan treatment. This study suggests a novel method of reporting ICG findings in extremities to enable easy understanding among surgeons and physiotherapists and avoid repeat testing when a patient visits a disparate lymphedema center or clinician. Methods A reporting protocol was developed in the lymphedema clinic of the plastic surgery department, and patients were asked to bring along the report in every subsequent review. The ICG findings were recorded on the fluorescence imaging system as well. The report was prepared by one and analyzed by two different clinicians without repeating the test on 10 consecutive patients. Results The interrater reliability of findings in the report was found to be 98.7% among the three clinicians. Conclusion The reporting system was found to be illustratable and reproducible.