Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
J Hazard Mater ; 428: 128279, 2022 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-35063838

RESUMO

The airborne transmission of SARS-CoV-2 remains surprisingly controversial; indeed, health and regulatory authorities still require direct proof of this mode of transmission. To close this gap, we measured the viral load of SARS-CoV-2 of an infected subject in a hospital room (through an oral and nasopharyngeal swab), as well as the airborne SARS-CoV-2 concentration in the room resulting from the person breathing and speaking. Moreover, we simulated the same scenarios to estimate the concentration of RNA copies in the air through a novel theoretical approach and conducted a comparative analysis between experimental and theoretical results. Results showed that for an infected subject's viral load ranging between 2.4 × 106 and 5.5 × 106 RNA copies mL-1, the corresponding airborne SARS-CoV-2 concentration was below the minimum detection threshold when the person was breathing, and 16.1 (expanded uncertainty of 32.8) RNA copies m-3 when speaking. The application of the predictive approach provided concentrations metrologically compatible with the available experimental data (i.e. for speaking activity). Thus, the study presented significant evidence to close the gap in understanding airborne transmission, given that the airborne SARS-CoV-2 concentration was shown to be directly related to the SARS-CoV-2 emitted. Moreover, the theoretical analysis was shown to be able to quantitatively link the airborne concentration to the emission.


Assuntos
Microbiologia do Ar , COVID-19 , SARS-CoV-2 , Aerossóis , COVID-19/virologia , Humanos , Carga Viral
2.
Geosci Front ; 13(6): 101398, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37521135

RESUMO

Public transport environments are thought to play a key role in the spread of SARS-CoV-2 worldwide. Indeed, high crowding indexes (i.e. high numbers of people relative to the vehicle size), inadequate clean air supply, and frequent extended exposure durations make transport environments potential hotspots for transmission of respiratory infections. During the COVID-19 pandemic, generic mitigation measures (e.g. physical distancing) have been applied without also considering the airborne transmission route. This is due to the lack of quantified data about airborne contagion risk in transport environments. In this study, we apply a novel combination of close proximity and room-scale risk assessment approaches for people sharing public transport environments to predict their contagion risk due to SARS-CoV-2 respiratory infection. In particular, the individual infection risk of susceptible subjects and the transmissibility of SARS-CoV-2 (expressed through the reproduction number) are evaluated for two types of buses, differing in terms of exposure time and crowding index: urban and long-distance buses. Infection risk and reproduction number are calculated for different scenarios as a function of the ventilation rates (both measured and estimated according to standards), crowding indexes, and travel times. The results show that for urban buses, the close proximity contribution significantly affects the maximum occupancy to maintain a reproductive number of <1. In particular, full occupancy of the bus would be permitted only for an infected subject breathing, whereas for an infected subject speaking, masking would be required. For long-distance buses, full occupancy of the bus can be maintained only if specific mitigation solutions are simultaneously applied. For example, for an infected person speaking for 1 h, appropriate filtration of the recirculated air and simultaneous use of FFP2 masks would permit full occupancy of the bus for a period of almost 8 h. Otherwise, a high percentage of immunized persons (>80%) would be needed.

3.
BMC Infect Dis ; 21(1): 1193, 2021 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-34836502

RESUMO

BACKGROUND: Effective vaccines are now available for SARS-CoV-2 in the 2nd year of the COVID-19 pandemic, but there remains significant uncertainty surrounding the necessary vaccination rate to safely lift occupancy controls in public buildings and return to pre-pandemic norms. The aim of this paper is to estimate setting-specific vaccination thresholds for SARS-CoV-2 to prevent sustained community transmission using classical principles of airborne contagion modeling. We calculated the airborne infection risk in three settings, a classroom, prison cell block, and restaurant, at typical ventilation rates, and then the expected number of infections resulting from this risk at varying percentages of occupant immunity. RESULTS: We estimate the setting-specific immunity threshold for control of wild-type SARS-CoV-2 to range from a low of 40% for a mechanically ventilation classroom to a high of 85% for a naturally ventilated restaurant. CONCLUSIONS: If vaccination rates are limited to a theoretical minimum of approximately two-thirds of the population, enhanced ventilation above minimum standards for acceptable air quality is needed to reduce the frequency and severity of SARS-CoV-2 superspreading events in high-risk indoor environments.


Assuntos
Poluição do Ar em Ambientes Fechados , COVID-19 , Humanos , Pandemias , SARS-CoV-2 , Vacinação , Ventilação
4.
Sci Total Environ ; 794: 148749, 2021 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-34225157

RESUMO

Although the interpersonal distance represents an important parameter affecting the risk of infection due to respiratory viruses, the mechanism of exposure to exhaled droplets remains insufficiently characterized. In this study, an integrated risk assessment is presented for SARS-CoV-2 close proximity exposure between a speaking infectious subject and a susceptible subject. It is based on a three-dimensional transient numerical model for the description of exhaled droplet spread once emitted by a speaking person, coupled with a recently proposed SARS-CoV-2 emission approach. Particle image velocimetry measurements were conducted to validate the numerical model. The contribution of the large droplets to the risk is barely noticeable only for distances well below 0.6 m, whereas it drops to zero for greater distances where it depends only on airborne droplets. In particular, for short exposures (10 s) a minimum safety distance of 0.75 m should be maintained to lower the risk below 0.1%; for exposures of 1 and 15 min this distance increases to about 1.1 and 1.5 m, respectively. Based on the interpersonal distances across countries reported as a function of interacting individuals, cultural differences, and environmental and sociopsychological factors, the approach presented here revealed that, in addition to intimate and personal distances, particular attention must be paid to exposures longer than 1 min within social distances (of about 1 m).


Assuntos
COVID-19 , SARS-CoV-2 , Aerossóis , COVID-19/transmissão , Expiração , Humanos , Medição de Risco
5.
Build Environ ; 202: 108042, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34127877

RESUMO

Reducing the transmission of SARS-CoV-2 through indoor air is the key challenge of the COVID-19 pandemic. Crowded indoor environments, such as schools, represent possible hotspots for virus transmission since the basic non-pharmaceutical mitigation measures applied so far (e.g. social distancing) do not eliminate the airborne transmission mode. There is widespread consensus that improved ventilation is needed to minimize the transmission potential of airborne viruses in schools, whether through mechanical systems or ad-hoc manual airing procedures in naturally ventilated buildings. However, there remains significant uncertainty surrounding exactly what ventilation rates are required, and how to best achieve these targets with limited time and resources. This paper uses a mass balance approach to quantify the ability of both mechanical ventilation and ad-hoc airing procedures to mitigate airborne transmission risk in the classroom environment. For naturally-ventilated classrooms, we propose a novel feedback control strategy using CO2 concentrations to continuously monitor and adjust the airing procedure. Our case studies show how such procedures can be applied in the real world to support the reopening of schools during the pandemic. Our results also show the inadequacy of relying on absolute CO2 concentration thresholds as the sole indicator of airborne transmission risk.

6.
Environ Int ; 145: 106112, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32927282

RESUMO

Airborne transmission is a recognized pathway of contagion; however, it is rarely quantitatively evaluated. The numerous outbreaks that have occurred during the SARS-CoV-2 pandemic are putting a demand on researchers to develop approaches capable of both predicting contagion in closed environments (predictive assessment) and analyzing previous infections (retrospective assessment). This study presents a novel approach for quantitative assessment of the individual infection risk of susceptible subjects exposed in indoor microenvironments in the presence of an asymptomatic infected SARS-CoV-2 subject. The application of a Monte Carlo method allowed the risk for an exposed healthy subject to be evaluated or, starting from an acceptable risk, the maximum exposure time. We applied the proposed approach to four distinct scenarios for a prospective assessment, highlighting that, in order to guarantee an acceptable risk of 10-3 for exposed subjects in naturally ventilated indoor environments, the exposure time could be well below one hour. Such maximum exposure time clearly depends on the viral load emission of the infected subject and on the exposure conditions; thus, longer exposure times were estimated for mechanically ventilated indoor environments and lower viral load emissions. The proposed approach was used for retrospective assessment of documented outbreaks in a restaurant in Guangzhou (China) and at a choir rehearsal in Mount Vernon (USA), showing that, in both cases, the high attack rate values can be justified only assuming the airborne transmission as the main route of contagion. Moreover, we show that such outbreaks are not caused by the rare presence of a superspreader, but can be likely explained by the co-existence of conditions, including emission and exposure parameters, leading to a highly probable event, which can be defined as a "superspreading event".


Assuntos
Infecções por Coronavirus/transmissão , Coronavirus , Pneumonia Viral/transmissão , Medição de Risco/métodos , Aerossóis , Poluição do Ar em Ambientes Fechados , Betacoronavirus , COVID-19 , China , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/prevenção & controle , Humanos , Pandemias , Pneumonia Viral/epidemiologia , Pneumonia Viral/prevenção & controle , Estudos Prospectivos , Estudos Retrospectivos , SARS-CoV-2
7.
Environ Int ; 141: 105794, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32416374

RESUMO

Airborne transmission is a pathway of contagion that is still not sufficiently investigated despite the evidence in the scientific literature of the role it can play in the context of an epidemic. While the medical research area dedicates efforts to find cures and remedies to counteract the effects of a virus, the engineering area is involved in providing risk assessments in indoor environments by simulating the airborne transmission of the virus during an epidemic. To this end, virus air emission data are needed. Unfortunately, this information is usually available only after the outbreak, based on specific reverse engineering cases. In this work, a novel approach to estimate the viral load emitted by a contagious subject on the basis of the viral load in the mouth, the type of respiratory activity (e.g. breathing, speaking, whispering), respiratory physiological parameters (e.g. inhalation rate), and activity level (e.g. resting, standing, light exercise) is proposed. The results showed that high quanta emission rates (>100 quanta h-1) can be reached by an asymptomatic infectious SARS-CoV-2 subject performing vocalization during light activities (i.e. walking slowly) whereas a symptomatic SARS-CoV-2 subject in resting conditions mostly has a low quanta emission rate (<1 quantum h-1). The findings in terms of quanta emission rates were then adopted in infection risk models to demonstrate its application by evaluating the number of people infected by an asymptomatic SARS-CoV-2 subject in Italian indoor microenvironments before and after the introduction of virus containment measures. The results obtained from the simulations clearly highlight that a key role is played by proper ventilation in containment of the virus in indoor environments.


Assuntos
Aerossóis/análise , Microbiologia do Ar , Infecções por Coronavirus/transmissão , Pneumonia Viral/transmissão , Betacoronavirus , COVID-19 , Expiração , Humanos , Itália , Boca/virologia , Pandemias , Medição de Risco , SARS-CoV-2 , Carga Viral
8.
Sci Total Environ ; 712: 135673, 2020 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-31810696

RESUMO

Indoor school gyms are environments characterized by high concentrations of different airborne particulate and gaseous pollutants. In particular, like other naturally-ventilated school environments, in addition to indoor pollutants children can be exposed to sub-micron particles and gaseous pollutants emitted by outdoor sources and penetrating the building envelope; moreover, high concentrations of super-micron particles can be reached due to the resuspension phenomena related to the physical activity performed therein. The present paper aims to evaluate the effect of different ventilation methods (natural ventilation, manual airing) and the use of air purifiers in reducing the indoor concentrations of different airborne particles and gaseous pollutants in school gyms. To this end, an experimental campaign was performed in two naturally-ventilated school gyms in Barcelona (Spain) of different volumes and different distance to major urban roads. Indoor and outdoor measurements of particle number, black carbon and PM1-10 concentrations were performed as well as indoor measurements of CO2 and NO2 concentrations. The study revealed that the use of air purifiers with windows kept closed (natural ventilation) can lead to a significant reduction in terms of indoor-to-outdoor concentration ratios. In the smaller gym (air changes per hour of the purifiers, ACH, equal to 9.2 h-1) the I/O ratios were reduced by 93% and 95% in terms of particle number and PM1-10, respectively; whereas in the larger school gym (ACH = 1.7 h-1) the corresponding reductions were 70% and 84%. For manual airing scenarios, the effect of the air purifiers on outdoor-generated sub-micron particles is reduced; in particular, for low ACH values (i.e. ACH = 1.7 h-1), the reduction is quite negligible (6%).


Assuntos
Filtros de Ar , Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Criança , Monitoramento Ambiental , Gases , Humanos , Tamanho da Partícula , Material Particulado , Instituições Acadêmicas , Espanha , Ventilação
9.
Waste Manag ; 101: 9-17, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-31586878

RESUMO

The paper is focused on the emission of sub-micron particles from incinerator plants characterized by different treatment sections. In particular, measurement of particle number concentrations and distributions in different sampling points of the flue-gas treatment sections, and/or over several years, allowed to detect, for the very first time through in-field tests, the effect of the age of the fabric filter bags and of the SCR system on the emission of sub-micron particles. In fact, tests showed that the age of the fabric filter bags can affect the particle number concentrations at the stack: indeed, for older bags higher concentrations at the stack were measured likely due to the filter cleaning process. Concerning the effect of the SCR system, the natural gas combustion performed in the SCR system leads to an increase of sub-micron particle concentrations at the stack with respect to the values measured after the filtration section.


Assuntos
Poluentes Atmosféricos , Incineração , Filtração , Tamanho da Partícula
10.
Sci Total Environ ; 656: 1032-1042, 2019 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-30625635

RESUMO

Air quality still represents a main threat to human health in cities. Even in developed countries, decades of air pollution control not yet allowed to reduce pollutant concentrations in urban areas adequately. Indeed, high airborne particle concentrations are measured in several European cities; this is a main issue since particles represent a carrier for carcinogenic compounds. Numerous researches measuring the exposure to the different aerosol metrics in urban areas were recently performed, nonetheless, few data on the lung cancer risk in such environments are available. In the present paper a novel approach to evaluate the lung cancer risk related to the airborne particles emitted by the different sources located in a city is proposed and applied to a pilot case-study (i.e. an Italian city). In particular, an existing lung cancer risk model was modified and applied to assess the particle-related lung cancer "emitted" by the different sources of the city using pollutant emission factors provided by accredited emission inventory databases. Therefore, the average toxicity of the particles emitted by the city (i.e. lung cancer slope factor) and the lung cancer risk globally emitted by the city, expressed as new cases of lung cancer, were evaluated. The proposed emission inventory also allowed to identify and localize the main contributors to the overall risk emitted in a city. As an example, for the city under investigation, the research revealed that the main contributor, amongst the sources considered, is the vehicular traffic which is characterized by a lower mass fraction of carcinogenic compounds but a much higher sub-micron particle emission with respect to the other sources.


Assuntos
Poluentes Atmosféricos/efeitos adversos , Carcinógenos/toxicidade , Monitoramento Ambiental/métodos , Gases/efeitos adversos , Neoplasias Pulmonares/epidemiologia , Material Particulado/efeitos adversos , Cidades/epidemiologia , Humanos , Itália/epidemiologia , Neoplasias Pulmonares/induzido quimicamente , Tamanho da Partícula , Medição de Risco/métodos
11.
Environ Pollut ; 240: 248-254, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29747109

RESUMO

Smoking activities were recognized as a main risk factor for population. Indeed, mainstream smoke aerosol is directly inhaled by smokers then delivering harmful compounds in the deepest regions of the lung. In order to reduce the potential risk of smoking, different nicotine delivery products have been recently developed. The latest device released is an electrically heated tobacco system (iQOS®, Philip Morris) which is able to warm the tobacco with no combustion. In the present paper a dimensional and volatility characterization of iQOS-generated particles was performed through particle number concentration and distribution measurements in the mainstream aerosol. The experimental analysis was carried out through a condensation particle counter, a fast mobility particle sizer and a thermo-dilution sampling system allowing aerosol samplings at different temperatures. Estimates of the particle surface area dose received by smokers were also carried out on the basis of measured data and typical smoking patterns. The particle number concentrations in the mainstream aerosols resulted lower than 1 × 108 part. cm-3 with particle number distribution modes of about 100 nm. Nonetheless, the volatility analysis showed the high amount of volatile fraction of iQOS-generated particles, indeed, samplings performed at 300 °C confirmed a significant particle shrinking phenomena (modes of about 20 nm). Anyway, the particle number concentration does not statistically decrease at higher sampling temperatures, then showing that a non-volatile fraction is always presents in the emitted particles. The dose received by smokers in terms of non-volatile amount of particle surface area was equal to 1-2 mm2 per puff, i.e. up to 4-fold larger than that received by electronic cigarette vapers.


Assuntos
Aerossóis/análise , Poluentes Atmosféricos/análise , Sistemas Eletrônicos de Liberação de Nicotina , Fumaça/análise , Eletricidade , Temperatura Alta , Humanos , Pulmão/química , Nicotina/análise , Tamanho da Partícula , Fumar , Nicotiana , Produtos do Tabaco , Fumar Tabaco , Volatilização
12.
Sci Total Environ ; 631-632: 1109-1116, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29727937

RESUMO

Combustion-generated nanoparticles are responsible for negative health effects due to their ability to penetrate in the lungs, carrying toxic compounds with them. In urban areas, the coexistence of nanoparticle sources and particular street-building configurations can lead to very high particle exposure levels. In the present paper, an innovative approach for the evaluation of lung cancer incidence in street canyon due to exposure to traffic-generated particles was proposed. To this end, the literature-available values of particulate matter, PAHs and heavy metals emitted from different kind of vehicles were used to calculate the Excess Lifetime Cancer Risk (ELCR) at the tailpipe. The estimated ELCR was then used as input data in a numerical CFD (Computational Fluid Dynamics) model that solves the mass, momentum, turbulence and species transport equations, in order to evaluate the cancer risk in every point of interest inside the street canyon. Thus, the influence of wind speed and street canyon geometry (H/W, height of building, H and width of the street, W) on the ELCR at street level was evaluated by means of a CFD simulation. It was found that the ELCR calculated on the leeward and windward sides of the street canyon at a breathable height of 1.5 m, for people exposed 15 min per day for 20 years, is equal to 1.5 × 10-5 and 4.8 × 10-6, respectively, for wind speed of 1 m/s and H/W equal to 1. The ELCR at street level results higher on the leeward side for aspect ratios equal to 1 and 3, while for aspect ratio equal to 2 it is higher on the windward side. In addition, the simulations showed that with the increasing of wind speed the ELCR becomes lower everywhere in the street canyon, due to the increased in dispersion.


Assuntos
Poluição do Ar/estatística & dados numéricos , Exposição Ambiental/estatística & dados numéricos , Neoplasias Pulmonares/epidemiologia , Modelos Teóricos , Poluentes Atmosféricos/análise , Cidades/epidemiologia , Humanos , Metais Pesados , Material Particulado/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Medição de Risco , Emissões de Veículos/análise , Vento
13.
Environ Pollut ; 235: 65-73, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29274539

RESUMO

Homes represent a critical microenvironment in terms of air quality due to the proximity to main particle sources and the lack of proper ventilation systems. Biomass-fed heating systems are still extensively used worldwide, then likely emitting a significant amount of particles in indoor environments. Nonetheless, research on biomass emissions are limited to their effects on outdoor air quality then not properly investigating the emission in indoor environments. To this purpose, the present paper aims to evaluate the exposure to different airborne particle metrics (including both sub- and super-micron particles) and attached carcinogenic compounds in dwellings where three different heating systems were used: open fireplaces, closed fireplaces and pellet stoves. Measurements in terms of particle number, lung-deposited surface area, and PM fraction concentrations were measured during the biomass combustion activities, moreover, PM10 samples were collected and chemically analyzed to obtain mass fractions of carcinogenic compounds attached onto particles. Airborne particle doses received by people exposed in such environments were evaluated as well as their excess lung cancer risk. Most probable surface area extra-doses received by people exposed to open fireplaces on hourly basis (56 mm2 h-1) resulted one order of magnitude larger than those experienced for exposure to closed fireplaces and pellet stoves. Lifetime extra risk of Italian people exposed to the heating systems under investigation were larger than the acceptable lifetime risk (10-5): in particular, the risk due to the open fireplace (8.8 × 10-3) was non-negligible when compared to the overall lung cancer risk of typical Italian population.


Assuntos
Poluentes Atmosféricos/toxicidade , Poluição do Ar em Ambientes Fechados/análise , Exposição Ambiental , Calefação , Neoplasias Pulmonares/epidemiologia , Poluentes Atmosféricos/análise , Biomassa , Humanos , Tamanho da Partícula , Fatores de Risco
14.
Sci Total Environ ; 616-617: 720-729, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29089125

RESUMO

Schools represent a critical microenvironment in terms of air quality due to the proximity to outdoor particle sources and the frequent lack of proper ventilation and filtering systems. Moreover, the population exposed in schools (i.e. children) represents a susceptible population due to their age. Air quality-based studies involving students' exposure at schools are still scarce and often limited to mass-based particle metrics and may thus underestimate the possible effect of sub-micron particles and particle toxicity. To this purpose, the present paper aims to evaluate the exposure to different airborne particle metrics (including both sub- and super-micron particles) and attached carcinogenic compounds. Measurements in terms of particle number, lung-deposited surface area, and PM fraction concentrations were measured inside and outside schools in Barcelona (Spain) and Cassino (Italy). Simultaneously, PM samples were collected and chemically analysed to obtain mass fractions of carcinogenic compounds. School time airborne particle doses received by students in classrooms were evaluated as well as their excess lung cancer risk due to a five-year primary school period. Median surface area dose received by students during school time in Barcelona and Cassino resulted equal to 110mm2 and 303mm2, respectively. The risk related to the five-year primary school period was estimated as about 2.9×10-5 and 1.4×10-4 for students of Barcelona and Cassino, respectively. The risk in Barcelona is slightly higher with respect to the maximum tolerable value (10-5, according to the U.S. Environmental Protection Agency), mainly due to toxic compounds on particles generated from anthropogenic emissions (mainly industry). On the other hand, the excess lung cancer risk in Cassino is cause of concern, being one order of magnitude higher than the above-mentioned threshold value due to the presence of biomass burning heating systems and winter thermal inversion that cause larger doses and great amount of toxic compounds on particles.


Assuntos
Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Exposição Ambiental/estatística & dados numéricos , Neoplasias Pulmonares/epidemiologia , Material Particulado/análise , Poluentes Atmosféricos/análise , Poluição do Ar , Criança , Europa (Continente) , Humanos , Itália/epidemiologia , Instituições Acadêmicas , Espanha/epidemiologia
15.
Environ Pollut ; 232: 113-122, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28919325

RESUMO

In the present study, the daily dose in terms of particle surface area received by citizens living in five cities in Western countries, characterized by different lifestyle, culture, climate and built-up environment, was evaluated and compared. For this purpose, the exposure to sub-micron particle concentration levels of the population living in Barcelona (Spain), Cassino (Italy), Guilford (United Kingdom), Lund (Sweden), and Brisbane (Australia) was measured through a direct exposure assessment approach. In particular, measurements of the exposure at a personal scale were performed by volunteers (15 per each population) that used a personal particle counter for different days in order to obtain exposure data in microenvironments/activities they resided/performed. Non-smoking volunteers performing non-industrial jobs were considered in the study. Particle concentration data allowed obtaining the exposure of the population living in each city. Such data were combined in a Monte Carlo method with the time activity pattern data characteristics of each population and inhalation rate to obtain the most probable daily dose in term of particle surface area as a function of the population gender, age, and nationality. The highest daily dose was estimated for citizens living in Cassino and Guilford (>1000 mm2), whereas the lowest value was recognized for Lund citizens (around 100 mm2). Indoor air quality, and in particular cooking and eating activities, was recognized as the main influencing factor in terms of exposure (and thus dose) of the population: then confirming that lifestyle (e.g. time spent in cooking activities) strongly affect the daily dose of the population. On the contrary, a minor or negligible contribution of the outdoor microenvironments was documented.


Assuntos
Poluentes Atmosféricos/análise , Exposição Ambiental/análise , Material Particulado/análise , Poluição do Ar em Ambientes Fechados/análise , Austrália , Cidades , Culinária , Meio Ambiente , Exposição Ambiental/estatística & dados numéricos , Monitoramento Ambiental/métodos , Feminino , Humanos , Itália , Estilo de Vida , Masculino , Método de Monte Carlo , Tamanho da Partícula , Espanha , Suécia , Reino Unido
16.
Oral Oncol ; 69: 38-45, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28559019

RESUMO

OBJECTIVE: Src family kinase (SFK) activation circumvents epidermal growth factor receptor (EGFR) targeting in head and neck squamous cell carcinoma (HNSCC); dual SFK-EGFR targeting could overcome cetuximab resistance. PATIENTS AND METHODS: We conducted a Simon two-stage, phase II trial of the SFK inhibitor, dasatinib, and cetuximab in biomarker-unselected patients with cetuximab-resistant, recurrent/metastatic HNSCC. Pre- and post-treatment serum levels of interleukin-6 (IL6) were measured by ELISA. HNSCC cell lines were assessed for viability and effects of IL6 modulation following dasatinib-cetuximab treatment. RESULTS: In the first stage, 13 patients were evaluable for response: 7 had progressive and 6 had stable disease (SD). Enrollment was halted for futility, and biomarker analysis initiated. Low serum IL6 levels were associated with SD (raw p=0.028, adjusted p=0.14) and improved overall survival (p=0.010). The IL6 classifier was validated in a separate trial of the same combination, but was unable to segregate survival risk in a clinical trial of cetuximab and bevacizumab suggesting serum IL6 may be specific for the dasatinib-cetuximab combination. Enhanced in vitro HNSCC cell death was observed with dasatinib-cetuximab versus single agent treatment; addition of IL6-containing media abrogated this effect. CONCLUSION: Clinical benefit and overall survival from the dasatinib-cetuximab combination were improved among patients with low serum IL6. Preclinical studies support IL6 as a modifier of dasatinib-cetuximab response. In the setting of clinical cetuximab resistance, serum IL6 is a candidate predictive marker specific for combined dasatinib-cetuximab. The trial was modified and redesigned as a biomarker-enriched Phase II study enrolling patients with undetectable IL6.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Carcinoma de Células Escamosas/tratamento farmacológico , Cetuximab/administração & dosagem , Dasatinibe/administração & dosagem , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Interleucina-6/sangue , Idoso , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Carcinoma de Células Escamosas/sangue , Resistencia a Medicamentos Antineoplásicos , Feminino , Neoplasias de Cabeça e Pescoço/sangue , Humanos , Masculino , Pessoa de Meia-Idade , Carcinoma de Células Escamosas de Cabeça e Pescoço , Análise de Sobrevida
17.
Sci Total Environ ; 580: 74-82, 2017 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-28012314

RESUMO

In order to estimate the lung cancer risk associated to airborne particles, exposure and risk-assessment studies ordinarily use particle mass concentration as dosimetry parameter. Consequently, the corresponding air quality targets are based on this metrics, neglecting the potential impact of ultrafine particles (UFPs) due to their negligible mass. The main purpose of this study was to evaluate the reliability of air quality targets in protecting Italian non-smoking people from lung cancer risk due to exposure to polycyclic aromatic hydrocarbons and some heavy metals associated with particle inhalation. A modified risk-assessment scheme was applied to estimate the cancer risk contribution from both sub-micron (mainly UFPs) and super-micron particles. We found a very high lung cancer risk related to the actual target levels due to the contribution of UFPs, in particular from indoor microenvironments. Therefore, as possible actions to reduce the lung cancer risk, we have hypothesized and tested three different scenarios: a) a reduction of the concentration of carcinogenic chemicals condensed onto particles in agreement with the current EU air pollution policy; b) the use of local ventilation systems to mitigate the exposure to cooking-generated particles; c) the improvement of the overall indoor air quality by considering a mechanical ventilation system instead of the widespread natural ventilation in order to increase the air exchange rates. Even with the simultaneous application of specific actions, performed with the best technologies available, the corresponding estimated lifetime lung cancer risk (ELCR) values for the Italian population for the entire life were equal to 1.25×10-4 and 1.23×10-4 for males and females, respectively, well higher with respect to the maximum tolerable lifetime cancer risk, 1×10-5.


Assuntos
Poluentes Atmosféricos/normas , Poluição do Ar em Ambientes Fechados , Neoplasias Pulmonares/epidemiologia , Feminino , Humanos , Itália , Masculino , Tamanho da Partícula , Reprodutibilidade dos Testes
18.
Environ Pollut ; 220(Pt A): 625-635, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27742438

RESUMO

In the present study a mobile monitoring approach (i.e. bike with onboard instruments) was proposed and applied to investigate the spatial variability of all the key airborne particle metrics in an Italian urban area from a statistical point of view. Particle number, alveolar-deposited surface area, and PM10 concentrations were measured through hand-held monitors and compared to simultaneous background concentrations by means of non-parametric tests and further post-hoc tests (Kruskal-Wallis test). Streets characterized by exposure levels statistically higher than the background levels for all the particle metrics were identified for different seasons in a pilot urban area (Cassino, Italy). A higher number of hot spots was detected for metrics affected by ultrafine particles (i.e. number and alveolar-deposited surface area concentrations) with respect to PM10. The effect of metrological requirements of the instrumentation on the proposed method was also discussed.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/instrumentação , Material Particulado/análise , Emissões de Veículos/análise , Poluentes Atmosféricos/química , Ciclismo , Cidades , Monitoramento Ambiental/métodos , Sistemas de Informação Geográfica , Itália , Tamanho da Partícula , Material Particulado/química , Projetos Piloto , Estações do Ano
19.
Indoor Air ; 27(2): 398-408, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27219830

RESUMO

The knowledge of exposure to the airborne particle emitted from three-dimensional (3D) printing activities is becoming a crucial issue due to the relevant spreading of such devices in recent years. To this end, a low-cost desktop 3D printer based on fused deposition modeling (FDM) principle was used. Particle number, alveolar-deposited surface area, and mass concentrations were measured continuously during printing processes to evaluate particle emission rates (ERs) and factors. Particle number distribution measurements were also performed to characterize the size of the emitted particles. Ten different materials and different extrusion temperatures were considered in the survey. Results showed that all the investigated materials emit particles in the ultrafine range (with a mode in the 10-30-nm range), whereas no emission of super-micron particles was detected for all the materials under investigation. The emission was affected strongly by the extrusion temperature. In fact, the ERs increase as the extrusion temperature increases. Emission rates up to 1×1012  particles min-1 were calculated. Such high ERs were estimated to cause large alveolar surface area dose in workers when 3D activities run. In fact, a 40-min-long 3D printing was found to cause doses up to 200 mm2 .


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Material Particulado/análise , Impressão Tridimensional , Temperatura , Tamanho da Partícula , Impressão/instrumentação
20.
J Hazard Mater ; 314: 155-163, 2016 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-27131455

RESUMO

In order to investigate the interaction between radon progeny and particles, an experimental campaign was carried out in a radon chamber at the Italian National Institute of Ionizing Radiation Metrology, quantifying the amount of attached and unattached radon daughters present in air, as well as the equilibrium factor in the presence of particles generated through indoor sources. A fixed radon concentration was maintained, while particles were generated using incense sticks, mosquito coils and gas combustion. Aerosols were characterized in terms of particle concentrations and size distributions. Simultaneously, radon concentration and attached/unattached potential alpha energy concentration in the air were continuously monitored by two different devices, based on alpha spectroscopy techniques. The presence of particles was found to affect the attached fraction of radon decay products, in such a way that the particles acted as a sink for radionuclides. In terms of sources which emit large particles (e.g. incense, mosquito coils), which greatly increase particle surface area concentrations, the Equilibrium Factor was found to double with respect to the background level before particle generation sessions. On the contrary, the radon decay product dynamics were not influenced by gas combustion processes, mainly due to the small surface area of the particles emitted.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...