Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38923248

RESUMO

PURPOSE: Robotic-assisted total knee arthroplasty (RA-TKA) is an increasingly popular alternative that may increase the accuracy of conventional TKA techniques. This study aims to evaluate RA-TKA accuracy and compare its radiographic and clinical outcomes to conventional TKA (cTKA). METHODS: A retrospective examination of patients with bi- or tricompartmental knee osteoarthritis who underwent RA-TKA (RObotic Surgical Assistant system) or cTKA and were prospectively documented in the TKA registry. Accuracy was assessed using standardized radiographic implant position evaluations, namely femoral and tibial coronal angles and femoral and tibial sagittal angles. Baseline demographics, surgery details and 6- and 12-month post-TKA patient-reported outcomes (PROMs; e.g., Oxford Knee Score [OKS] and Core Outcome Measures Index) were compared between RA-TKA and propensity score-matched cTKA patients. RESULTS: Overall correlation between preset and 6-week postoperative angle measurements for RA-TKA was low with significant differences noted only for mean tibial sagittal angles (84.6° [RA-TKA] vs. 82.3° [cTKA]) (p < 0.001). The study groups were demographically similar, although RA-TKA patients had slightly longer operative times and higher blood loss but shorter inpatient stays. There were sustainable improvements in all PROMs already at 6 months, yet RA-TKA patients had significantly higher OKS values over their conventional counterparts at this time point. CONCLUSION: Radiological and clinical outcomes were comparable between RA-TKA and cTKA. The robotic-assisted system demonstrated higher accuracy in the coronal than sagittal plane and RA-TKA patients achieved better short-term outcomes for pain and disability. While both methods are similar in the hands of a skilled surgeon, long-term studies are necessary to establish clear method superiority. LEVEL OF EVIDENCE: Therapeutic, Level III.

2.
Bone Joint J ; 106-B(5 Supple B): 32-39, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38688500

RESUMO

Aims: The purpose of this study was to evaluate the mid-term outcomes of autologous matrix-induced chondrogenesis (AMIC) for the treatment of larger cartilage lesions and deformity correction in hips suffering from symptomatic femoroacetabular impingement (FAI). Methods: This single-centre study focused on a cohort of 24 patients with cam- or pincer-type FAI, full-thickness femoral or acetabular chondral lesions, or osteochondral lesions ≥ 2 cm2, who underwent surgical hip dislocation for FAI correction in combination with AMIC between March 2009 and February 2016. Baseline data were retrospectively obtained from patient files. Mid-term outcomes were prospectively collected at a follow-up in 2020: cartilage repair tissue quality was evaluated by MRI using the Magnetic Resonance Observation of Cartilage Repair Tissue (MOCART) score. Patient-reported outcome measures (PROMs) included the Oxford Hip Score (OHS) and Core Outcome Measure Index (COMI). Clinical examination included range of motion, impingement tests, and pain. Results: A total of 12 hips from 11 patients were included (ten males, one female, mean age 26.8 years (SD 5.0), mean follow-up 6.2 years (SD 5.2 months)). The mean postoperative MOCART score was 66.3 (SD 16.3). None of the patients required conversion to total hip arthroplasty. Two patients had anterior impingement. External hip rotation was moderately limited in four patients. There was a correlation between MOCART and follow-up time (rs = -0.61; p = 0.035), but not with initial cartilage damage, age, BMI, or imaging time delay before surgery. PROMs improved significantly: OHS from 37.4 to 42.7 (p = 0.014) and COMI from 4.1 to 1.6 (p = 0.025). There was no correlation between MOCART and PROMs. Conclusion: Based on the reported mid-term results, we consider AMIC as an encouraging treatment option for large cartilage lesions of the hip. Nonetheless, the clinical evidence of AMIC in FAI patients remains to be determined, ideally in the context of randomized controlled trials.


Assuntos
Cartilagem Articular , Condrogênese , Impacto Femoroacetabular , Humanos , Impacto Femoroacetabular/cirurgia , Impacto Femoroacetabular/diagnóstico por imagem , Feminino , Masculino , Adulto , Estudos Retrospectivos , Cartilagem Articular/cirurgia , Transplante Autólogo , Resultado do Tratamento , Medidas de Resultados Relatados pelo Paciente , Amplitude de Movimento Articular , Adulto Jovem , Imageamento por Ressonância Magnética , Seguimentos
3.
Bone ; 180: 117011, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38176642

RESUMO

Osteoporosis poses a major public health challenge, and it is characterized by low bone mass, deterioration of the microarchitecture of bone tissue, causing a consequent increase in bone fragility and susceptibility to fractures and complicating bone fixation, particularly screw implantation. In the present study, our aim was to improve implant stability in osteoporotic bone using a thermoresponsive hyaluronan hydrogel (HA-pNIPAM) to locally deliver the bisphosphonate zoledronic acid (ZOL) to prevent bone resorption and bone morphogenetic protein 2 (BMP2) to induce bone formation. Adult female Wistar rats (n = 36) were divided into 2 treatment groups: one group of SHAM-operated animals and another group that received an ovariectomy (OVX) to induce an osteoporotic state. All animals received a polyetheretherketone (PEEK) screw in the proximal tibia. In addition, subgroups of SHAM or OVX animals received either the HA-pNIPAM hydrogel without or with ZOL/BMP2, placed into the defect site prior to screw implantation. Periprosthetic bone and implant fixation were monitored using longitudinal in vivo microCT scanning post-operatively and at 3, 6, 9, 14, 20 and 28 days. Histological assessment was performed post-mortem. Our data showed that pure hydrogel has no impact of implant fixation The ZOL/BMP2-hydrogel significantly increased bone-implant contact and peri-implant bone fraction, primarily through reduced resorption. STATEMENT OF CLINICAL SIGNIFICANCE: Local delivery of ZOL and BMP2 using a biocompatible hydrogel improved implant stability in osteoporotic bone. This approach could constitute a potent alternative to systemic drug administration and may be useful in avoiding implant loosening in clinical settings.


Assuntos
Conservadores da Densidade Óssea , Osteoporose , Ratos , Feminino , Animais , Humanos , Ácido Zoledrônico/uso terapêutico , Proteína Morfogenética Óssea 2/uso terapêutico , Microtomografia por Raio-X , Hidrogéis , Imidazóis/farmacologia , Imidazóis/uso terapêutico , Ratos Wistar , Osseointegração , Difosfonatos/uso terapêutico , Osteoporose/diagnóstico por imagem , Osteoporose/tratamento farmacológico , Osteoporose/patologia , Tíbia/patologia , Parafusos Ósseos , Ovariectomia , Conservadores da Densidade Óssea/uso terapêutico
4.
J Child Orthop ; 17(5): 459-468, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37799311

RESUMO

Purpose: The conditions leading to growth rebound after hemiepiphysiodesis are still poorly understood. This article analyzes the radiographical outcomes after guided growth with tension band plating, using plates in idiopathic genu valgum patients and attempts to generate a predictive model of growth rebound. Methods: Patients with idiopathic genu valgum deformity who received tension band plating were selected for evaluation. We only analyzed coronal plane deformities. Only patients with a long-standing X-ray before tension band plating surgery, a long-standing X-ray at tension band plating removal, and a long-standing X-ray at the latest follow-up after tension band plating removal were considered for this study. The change of mechanical axis deviation between the tension band plating removal and the last follow-up was evaluated for rebound, and ordinal logistic regression was performed to determine the relevant variables for predictive modeling rebound growth. Results: Overall, 100 patients (189 legs) were analyzed. The mean mechanical axis deviation at tension band plating removal was 8.4 mm in varus direction, and the mean mechanical axis deviation at the last follow-up was -3.4 mm (p ≤ 0.001). However, 111 legs (59%) showed rebound growth, 57 (30%) stayed stable, and 21 (11%) showed a continuous correction. Six significant factors significantly influencing rebound were isolated which are clinically relevant: sex, age, baseline mechanical axis deviation, mechanical lateral distal femoral angle, and mechanical medial proximal tibial angle, and mechanical axis deviation correction rate. Mechanical axis deviation correction rate had the highest odds ratios. The machine learning classification model for predicting rebound growth built from the study data showed a misclassification rate of 39%. Conclusion: There was a high rate of rebound growth in this cohort, especially for patients at a young age at implantation. The highest risk factors for rebound growth were male sex, and high correction rates, such as found during peak growth spurt. The proposed classification model needs more data to improve its predictive power before it can be used in clinics. Level of evidence: Level III.

5.
Knee Surg Sports Traumatol Arthrosc ; 31(11): 4977-4987, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37634136

RESUMO

PURPOSE: Minced cartilage is a one-step, autologous procedure with promising short-term results. The aim of the present study was to evaluate mid-term results in a patient cohort with chondral and osteochondral lesions in the knee joint treated with minced cartilage. METHODS: From 2015 through 2016, a total of 34 consecutive patients were treated with a single-step, autologous minced cartilage for knee chondral and osteochondral lesions. Numeric analogue scale (NAS) for pain and knee function were obtained prior to surgery and at 12, 24 and 60 months postoperatively. Secondary outcomes, including Lysholm score, Tegner activity score, and the International Knee Documentation Committee (IKDC) score, were recorded at final follow-up. MRI examinations of patients with unplanned radiological follow-up were analysed using the MOCART (Magnetic Resonance Observation of Cartilage Repair Tissue) score. RESULTS: A total of 28 patients (44.1% females, age at surgery: 29.5 ± 11.5 years) were available at a mean follow-up of 65.5 ± 4.1 months. Mean defect size was 3.5 ± 1.8 cm2. NAS for pain decreased from a median of 7 (range: 2-10) preoperatively to 2 (0-8) postoperatively. NAS knee function improved from a median of 7 (range: 2-10) to 3 (0-7) after five years, respectively. Satisfactory Lysholm (76.5 ± 12.5), IKDC (71.6 ± 14.8) and Tegner activity (4, range 3-9) scores were reported at final follow-up. Of all patients, 21(75%) and 19 (67.9%) reached or exceeded the PASS for the IKDC- and Lysholm score at final follow-up, respectively. The average overall MOCART 2.0 scores for all postoperatively performed MRIs (n = 23) was 62.3 ± 17.4. Four (14.2%) postoperative complications were directly linked to minced cartilage, one (3.5%) of which required revision surgery. CONCLUSION: One-step, autologous minced cartilage repair of chondral and osteochondral lesions of the knee without the necessity for subchondral bone treatment demonstrated good patient-reported outcomes, low complication rates, and graft longevity at mid-term follow-up. Minced cartilage represents a viable treatment option to more traditional cartilage repair techniques even in mid-term. LEVEL OF EVIDENCE: Level III.


Assuntos
Cartilagem Articular , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Masculino , Reoperação , Cartilagem Articular/cirurgia , Seguimentos , Transplante Autólogo , Articulação do Joelho/cirurgia , Imageamento por Ressonância Magnética , Dor/cirurgia
7.
J Patient Rep Outcomes ; 7(1): 18, 2023 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-36854937

RESUMO

BACKGROUND: While there are a few studies on measurement properties of PROMIS short forms for pain and function in patients with knee osteoarthritis, nothing is known about the measurement properties in patients with knee arthroplasty. Therefore, this study examined the measurement properties of the German Patient-Reported Outcomes Measurement Information System (PROMIS) short forms for pain intensity (PAIN), pain interference (PI) and physical function (PF) in knee arthroplasty patients. METHODS: Short forms were collected from consecutive patients of our clinic's knee arthroplasty registry before and 12 months post-surgery. Oxford Knee Score (OKS) was the reference measure. A subsample completed the short forms twice to test reliability. Construct validity and responsiveness were assessed using scale-specific hypothesis testing. For reliability, Cronbach's alpha, intraclass correlation coefficients, and agreement using standard error of measurement (SEMagr) were used. Agreement was used to determine standardised effect sizes and smallest detectable changes (SDC90). Individual-level minimal important change (MIC) was calculated using a method of adjusted prediction. RESULTS: Of 213 eligible patients, 155 received questionnaires, 143 returned baseline questionnaires and 119, 12-month questionnaires. Correlations of short forms with OKS were large (│r│ ≥ 0.7) with slightly lower values for PAIN, and specifically for men. Cronbach's alpha values were ≥ 0.84 and intraclass correlation coefficients ≥ 0.90. SEMagr were around 3.5 for PAIN and PI and 1.7 for PF. SDC90 were around 8 for PAIN and PI and 4 for PF. Follow-up showed a relevant ceiling effect for PF. Correlations with OKS change scores of around 0.5 to 0.6 were moderate. Adjusted MICs were 7.2 for PAIN, 3.5 for PI and 5.7 for PF. CONCLUSION: Our results partly support the use of the investigated short forms for knee arthroplasty patients. The ability of PF to differentiate between patients with high perceived recovery is limited. Therefore, the advantages and disadvantages should be strongly considered within the context of the intended use.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Masculino , Humanos , Reprodutibilidade dos Testes , Medidas de Resultados Relatados pelo Paciente , Osteoartrite do Joelho/diagnóstico , Inquéritos e Questionários
8.
Foot Ankle Surg ; 29(2): 158-164, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36566121

RESUMO

BACKGROUND: Severe flexible flatfeet with triceps surae complex shortening are prognostically unfavorable in early childhood and may compromise normal foot development. METHODS: This retrospective, IRB-approved study included 20 children (38 feet) under 6 years with severe flexible flatfeet and triceps surae complex shortening. Treatment included minimally invasive percutaneous achilles tendon lengthening followed by a 4-week cast fixation and corrective orthotic therapy under talo-navicular reposition for at least 6-months. Preoperative weightbearing x-rays and at the last available follow-up included anteroposterior talus-first metatarsal angle and lateral talus pitch, Meary's and talocalcaneal angle and were compared to reference values. ROM, surgeon-rated clinical outcomes and complications/re-interventions were evaluated. RESULTS: Age at surgery was 3.7 years (1.3-5.9 y) and follow-up time was 4.3 years (1.1-8.9 y). No complications occurred. Clinical outcome was good (68 %) to very good (26 %). Ratio of normal angles increased significantly for three angles. Dorsiflexion ROM improved from -5.0 ± 6.8° at baseline to 15.7 ± 7.6°. CONCLUSIONS: With significant improvements in clinical and radiographic outcomes, minimal-invasive percutaneous Achilles tendon lengthening followed by orthotic therapy seems to be a valuable treatment option for selected preschool-aged patients with severe, flexible flatfeet with significantly shortened triceps surae. LEVEL OF EVIDENCE: IV.


Assuntos
Tendão do Calcâneo , Pé Chato , Tálus , Criança , Humanos , Pré-Escolar , Tenotomia , Estudos Retrospectivos , Pé Chato/diagnóstico por imagem , Pé Chato/cirurgia , Tendão do Calcâneo/diagnóstico por imagem , Tendão do Calcâneo/cirurgia
9.
Arthrosc Tech ; 12(12): e2375-e2379, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38196858

RESUMO

Optimal graft fixation in anterior cruciate ligament reconstruction is critical. Several direct and indirect methods of graft fixation exist, each with advantages and disadvantages. This Technical Note describes a tibial hybrid anterior cruciate ligament graft fixation technique combining direct and indirect fixation methods, including autologous bone augmentation of the drill tunnel using cancellous bone fragments.

10.
Bone Joint J ; 104-B(7): 826-832, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35775167

RESUMO

AIMS: It is not known whether preservation of the capsule of the hip positively affects patient-reported outcome measures (PROMs) in total hip arthroplasty using the direct anterior approach (DAA-THA). A recent randomized controlled trial found no clinically significant difference at one year postoperatively. This study aimed to determine whether preservation of the anterolateral capsule and anatomical closure improve the outcome and revision rate, when compared with resection of the anterolateral capsule, at two years postoperatively. METHODS: Two consecutive groups of patients whose operations were performed by the senior author were compared. The anterolateral capsule was resected in the first group of 430 patients between January 2012 and December 2014, and preserved and anatomically closed in the second group of 450 patients between July 2015 and December 2017. There were no other technical changes between the two groups. Patient characteristics, the Charlson Comorbidity Index (CCI), and surgical data were collected from our database. PROM questionnaires, consisting of the Oxford Hip Score (OHS) and Core Outcome Measures Index (COMI-Hip), were collected two years postoperatively. Data were analyzed with generalized multiple regression analysis. RESULTS: The characteristics, CCI, operating time, and length of stay were similar in both groups. There was significantly less blood loss in the capsular preservation group (p = 0.037). The revision rate (n = 3, (0.6%) in the resected group, and 1 (0.2%) in the preserved group) did not differ significantly (p = 0.295). Once adjusted for demographic and surgical factors, the preserved group had significantly worse PROMs: + 0.24 COMI-Hip (p < 0.001) and -1.6 OHS points (p = 0.017). However, the effect sizes were much smaller than the minimal clinically important differences (MCIDs) of 0.95 and 5, respectively). The date of surgery (influencing, for instance, the surgeon's age) was not a significant factor. CONCLUSION: Based on the MCID, the lower PROMs in the capsular preservation group do not seem to have clinical relevance. They do not, however, confirm the expected benefit of capsular preservation reported for the posterolateral approach. Cite this article: Bone Joint J 2022;104-B(7):826-832.


Assuntos
Artroplastia de Quadril , Artroplastia de Quadril/efeitos adversos , Humanos , Diferença Mínima Clinicamente Importante , Medidas de Resultados Relatados pelo Paciente , Resultado do Tratamento
11.
Injury ; 53(6): 1858-1866, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35469636

RESUMO

INTRODUCTION: The fixation of small intraarticular bone fragments is clinically challenging and an obvious first orthopaedic indication for an effective bone adhesive. In the present study the feasibility of bonding freshly harvested human trabecular bone with OsSticR, a novel phosphoserine modified cement, was evaluated using a bone cylinder model pull-out test and compared with a commercial fibrin tissue adhesive. METHODS: Femoral heads (n=13) were collected from hip fracture patients undergoing arthroplasty and stored refrigerated overnight in saline medium prior to testing. Cylindrical bone cores with a pre-inserted bone screw, were prepared using a coring tool. Each core was removed and glued back in place with either the bone adhesive (α-tricalcium phosphate, phosphoserine and 20% trisodium citrate solution) or the fibrin glue. All glued bones were stored in bone medium at 37°C. Tensile loading, using a universal testing machine (5 kN load cell), was applied to each core/head. For the bone adhesive, bone cores were tested at 2 (n=13) and 24 (n=11) hours. For the fibrin tissue adhesive control group (n=9), bone cores were tested exclusively at 2 hours. The femoral bone quality was evaluated with micro-CT. RESULTS: The ultimate pull-out load for the bone adhesive at 2 hours ranged from 36 to 171 N (mean 94 N, SD 42 N). At 24 hours the pull-out strength was similar, 47 to 198 N (mean 123 N, SD 43 N). The adhesive failure usually occurred through the adhesive layer, however in two samples, at 167 N and 198 N the screw pulled out of the bone core. The fibrin tissue adhesive group reached a peak force of 8 N maximally at 2 hours (range 2.8-8 N, mean 5.4 N, SD 1.6 N). The mean BV/TV for femoral heads was 0.15 and indicates poor bone quality. CONCLUSION: The bone adhesive successfully glued wet and fatty tissue of osteoporotic human bone cores. The mean ultimate pull-out force of 123 N at 24 hours corresponds to ∼ 300 kPa shear stress acting on the bone core. These first ex-vivo results in human bone are a promising step toward potential clinical application in osteochondral fragment fixation.


Assuntos
Adesivos , Cabeça do Fêmur , Fenômenos Biomecânicos , Cimentos Ósseos/farmacologia , Parafusos Ósseos , Adesivo Tecidual de Fibrina/farmacologia , Humanos , Fosfosserina
12.
Int J Biomed Imaging ; 2021: 4998786, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34594369

RESUMO

OBJECTIVE: While microCT evaluation of atherosclerotic lesions in mice has been formally validated, existing image processing methods remain undisclosed. We aimed to develop and validate a reproducible image processing workflow based on phosphotungstic acid-enhanced microCT scans for the volumetric quantification of atherosclerotic lesions in entire mouse aortas. Approach and Results. 42 WT and 42 apolipoprotein E knockout mouse aortas were scanned. The walls, lumen, and plaque objects were segmented using dual-threshold algorithms. Aortic and plaque volumes were computed by voxel counting and lesion surface by triangulation. The results were validated against manual and histological evaluations. Knockout mice had a significant increase in plaque volume compared to wild types with a plaque to aorta volume ratio of 0.3%, 2.8%, and 9.8% at weeks 13, 18, and 26, respectively. Automatic segmentation correlated with manual (r 2 ≥ 0.89; p < .001) and histological evaluations (r 2 > 0.96; p < .001). CONCLUSIONS: The semiautomatic workflow enabled rapid quantification of atherosclerotic plaques in mice with minimal manual work.

13.
Microorganisms ; 9(9)2021 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-34576840

RESUMO

Total joint arthroplasty (TJA) surgeries are common orthopedic procedures, but bacterial infection remains a concern. The aim of this study was to assess interactions between wear particles (WPs) and immune cells in vitro and to investigate if WPs affect the severity, or response to antibiotic therapy, of a Staphylococcus epidermidis orthopedic device-related infection (ODRI) in a rodent model. Biofilms grown on WPs were challenged with rifampin and cefazolin (100 µg/mL) to determine antibiotic efficacy. Neutrophils or peripheral blood mononuclear cells (PBMCs) were incubated with or without S. epidermidis and WPs, and myeloperoxidase (MPO) and cytokine release were analyzed, respectively. In the ODRI rodent model, rats (n = 36) had a sterile or S. epidermidis-inoculated screw implanted in the presence or absence of WPs, and a subgroup was treated with antibiotics. Bone changes were monitored using microCT scanning. The presence of WPs decreased antibiotic efficacy against biofilm-resident bacteria and promoted MPO and pro-inflammatory cytokine production in vitro. WPs exacerbated osteolytic responses to S. epidermidis infection and markedly reduced antibiotic efficacy in vivo. Overall, this work shows that the presence of titanium WPs reduces antibiotic efficacy in vitro and in vivo, induces proinflammatory cytokine release, and exacerbates S. epidermidis-induced osteolysis.

14.
J Patient Rep Outcomes ; 5(1): 41, 2021 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-34056667

RESUMO

INTRODUCTION: While the Patient-Reported Outcomes Measurement Information System (PROMIS) is mainly designed for computer adaptive testing, its static short forms (SF) are used when a paper-pencil format is preferred or item banks are not yet translated into the target language. This study examined the measurement properties of the German PROMIS-SF for pain intensity (PAIN), pain interference (PI) and physical function (PF) in total hip arthroplasty (THA) patients. METHODS: SF were collected before and 12 months post-surgery. Higher scores indicate more PAIN, higher PI and better PF. Oxford Hip Score (OHS) was the main reference measure. Six months post-surgery, a subsample completed the SF twice within 14 days to test reliability. RESULTS: Of 172 eligible patients, 147 consented to participate and received questionnaires; 132 (74 males) returned baseline questionnaires (mean age 65.8 ± 10.2 years) and 116, 12-month questionnaires. Forty-five patients provided test-retest data. Correlations of all SF with OHS were large (│r│ ≥ 0.7; confidence intervals did not include 0.50). Cronbach's alpha values were: PAIN, 0.86; PI, 0.93; PF, 0.91. Intraclass correlation coefficients were: PAIN, 0.77; PI, 0.81; PF, 0.69. Standard errors of measurement were: PAIN, 3.8; PI, 2.8; PF, 3.6. Smallest detectable change thresholds were: PAIN, 8.8; PI, 6.6; PF, 8.4. Follow-up data showed a ceiling effect (best score) for PAIN (66%), PI (76%), and PF (66%). SF change scores showed large correlations with OHS change scores (│r│ > 0.6). CONCLUSION: Our results provide some evidence of construct validity, and acceptable reliability and responsiveness of PROMIS-SF for pain and function in THA patients. These SF can thus be considered acceptable for use, although patients' improvement in physical function might be underestimated due to the large follow-up PF score ceiling effects.


Measurement qualities of PROMIS instruments are mainly assessed for computer adaptive testing but not for non-adaptive short questionnaires. As these questionnaires are in use, their measurement properties must also be evaluated. Results from computer adaptive testing cannot simply be transferred.We studied the measurement qualities of the German PROMIS short questionnaires for pain intensity, pain interference and physical function in patients undergoing hip replacement. We wanted to see how these questionnaires perform when compared to the Oxford Hip Score, a standard questionnaire commonly used to test hip-related disability in these patients.The three questionnaires can be considered acceptable for use in hip replacement patients, but some limitations do exist. Patient improvement in physical function might be underestimated because many patients reach the highest possible score and further improvements cannot be measured. Also, any small but important improvement in physical function cannot be distinguished from measurement error in individual patients.

15.
BMC Musculoskelet Disord ; 22(1): 310, 2021 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-33781252

RESUMO

BACKGROUND: Inaccurate projection on standard pelvic radiographs leads to the underestimation of femoral offset-a critical determinant of postoperative hip function-during total hip arthroplasty (THA) templating. We noted that the posteromedial facet of the greater trochanter and piriformis fossa form a double contour on radiographs, which may be valuable in determining the risk of underestimating femoral offset. We evaluate whether projection errors can be predicted based on the double contour width. METHODS: Plain anteroposterior (AP) pelvic radiographs and magnetic resonance images (MRIs) of 64 adult hips were evaluated retrospectively. Apparent femoral offset, apparent femoral head diameter and double contour widths were evaluated from the radiographs. X-ray projection errors were estimated by comparison to the true neck length measured on MRIs after calibration to the femoral heads. Multivariate analysis with backward elimination was used to detect associations between the double contour width and radiographic projection errors. Femoral offset underestimation below 10% was considered acceptable for templating. RESULTS: The narrowest width of the double line between the femoral neck and piriformis fossa is significantly associated with projection error. When double line widths exceed 5 mm, the risk of projection error greater than 10% is significantly increased compared to narrower double lines, and the acceptability rate for templating drops below 80% (p = 0.02). CONCLUSION: The double contour width is a potential landmark for excluding pelvic AP radiographs unsuitable for THA templating due to inaccurate femoral rotation.


Assuntos
Artroplastia de Quadril , Articulação do Quadril , Adulto , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
16.
J Orthop Res ; 39(2): 415-425, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33325074

RESUMO

A significant proportion of orthopedic devices are implanted in osteoporotic patients, but it is currently unclear how estrogen deficiency and/or exposure to antiresorptive bisphosphonates (BPs) influence orthopedic device-related infection (ODRI), or response to therapy. The aim of this study is to characterize the bone changes resulting from Staphylococcus epidermidis infection in a rodent ODRI model and to determine if ovariectomy (OVX) or BP treatment influences the infection or the success of antibiotic therapy. A sterile or S. epidermidis-contaminated screw was implanted into the proximal tibia of skeletally mature female Wistar rats (n = 6-9 per group). Bone changes were monitored over 28 days using in vivo micro-computed tomography scanning. OVX was performed 12 weeks before screw implantation. The BP zoledronic acid (ZOL) was administered 4 days before screw insertion. A combination antibiotic regimen (rifampin plus cefazolin) was administered from Days 7-21. In skeletally healthy animals, S. epidermidis induced marked changes in bone, with peak osteolysis occurring at Day 9 and woven bone deposition and periosteal mineralization from Day 14 onwards. Antibiotic therapy cleared the infection in the majority of animals (2/9 infected) but did not affect bone responses. OVX did not affect the pattern of infection-induced changes in bone, nor bacterial load, but reduced antibiotic efficacy (5/9 infected). ZOL treatment did not protect from osteolysis in OVX animals, or further affect antibiotic efficacy (5/9 infected) but did significantly increase the bacterial load. This study suggests that both BPs and OVX can influence host responses to bone infections involving S. epidermidis.


Assuntos
Antibacterianos/uso terapêutico , Conservadores da Densidade Óssea/efeitos adversos , Osso e Ossos/efeitos dos fármacos , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Estafilocócicas/tratamento farmacológico , Animais , Osso e Ossos/diagnóstico por imagem , Modelos Animais de Doenças , Estrogênios/deficiência , Feminino , Infecções Relacionadas à Prótese/complicações , Infecções Relacionadas à Prótese/diagnóstico por imagem , Ratos , Ratos Wistar , Infecções Estafilocócicas/complicações , Infecções Estafilocócicas/diagnóstico por imagem , Staphylococcus epidermidis , Microtomografia por Raio-X
17.
Clin Infect Dis ; 72(12): e1064-e1073, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-33300545

RESUMO

BACKGROUND: Cutibacterium species are common pathogens in periprosthetic joint infections (PJI). These infections are often treated with ß-lactams or clindamycin as monotherapy, or in combination with rifampin. Clinical evidence supporting the value of adding rifampin for treatment of Cutibacterium PJI is lacking. METHODS: In this multicenter retrospective study, we evaluated patients with Cutibacterium PJI and a minimal follow-up of 12 months. The primary endpoint was clinical success, defined by the absence of infection relapse or new infection. We used Fisher's exact tests and Cox proportional hazards models to analyze the effect of rifampin and other factors on clinical success after PJI. RESULTS: We included 187 patients (72.2% male, median age 67 years) with a median follow-up of 36 months. The surgical intervention was a 2-stage exchange in 95 (50.8%), 1-stage exchange in 51 (27.3%), debridement and implant retention (DAIR) in 34 (18.2%), and explantation without reimplantation in 7 (3.7%) patients. Rifampin was included in the antibiotic regimen in 81 (43.3%) cases. Infection relapse occurred in 28 (15.0%), and new infection in 13 (7.0%) cases. In the time-to-event analysis, DAIR (adjusted hazard ratio [HR] = 2.15, P = .03) and antibiotic treatment over 6 weeks (adjusted HR = 0.29, P = .0002) significantly influenced treatment failure. We observed a tentative evidence for a beneficial effect of adding rifampin to the antibiotic treatment-though not statistically significant for treatment failure (adjusted HR = 0.5, P = .07) and not for relapses (adjusted HR = 0.5, P = .10). CONCLUSIONS: We conclude that a rifampin combination is not markedly superior in Cutibacterium PJI, but a dedicated prospective multicenter study is needed.


Assuntos
Infecções Relacionadas à Prótese , Rifampina , Idoso , Antibacterianos/uso terapêutico , Desbridamento , Feminino , Humanos , Masculino , Estudos Prospectivos , Infecções Relacionadas à Prótese/tratamento farmacológico , Estudos Retrospectivos , Rifampina/uso terapêutico , Resultado do Tratamento
18.
Sci Rep ; 10(1): 20901, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33262377

RESUMO

Subclinical infection associated with orthopedic devices can be challenging to diagnose. The goal of this study was to evaluate longitudinal, microcomputed tomography (microCT) imaging in a rat model of subclinical orthopedic device-related infection caused by Staphylococcus epidermidis and four different Cutibacterium (previously Propionibacterium) acnes strains, and compare outcomes with non-inoculated and historical S. aureus-inoculated controls. Sterile screws or screws colonized with bacteria were placed in the tibia of 38 adult Wistar rats [n = 6 sterile screws; n = 6 S. epidermidis-colonized screws; n = 26 C. acnes-colonized screws (covering all three main subspecies)]. Regular microCT scans were taken over 28 days and processed for quantitative time-lapse imaging with dynamic histomorphometry. At euthanasia, tissues were processed for semiquantitative histopathology or quantitative bacteriology. All rats receiving sterile screws were culture-negative at euthanasia and displayed progressive bony encapsulation of the screw. All rats inoculated with S. epidermidis-colonized screws were culture-positive and displayed minor changes in peri-implant bone, characteristic of subclinical infection. Five of the 17 rats in the C. acnes inoculated group were culture positive at euthanasia and displayed bone changes at the interface of the screw and bone, but not deeper in the peri-implant bone. Dynamic histomorphometry revealed significant differences in osseointegration, bone remodeling and periosteal reactions between groups that were not measurable by visual observation of still microCT images. Our study illustrates the added value of merging 3D microCT data from subsequent timepoints and producing inherently richer 4D data for the detection and characterization of subclinical orthopedic infections, whilst also reducing animal use.


Assuntos
Infecções Bacterianas/diagnóstico por imagem , Parafusos Ósseos/efeitos adversos , Imagem com Lapso de Tempo , Microtomografia por Raio-X/métodos , Animais , Infecções Assintomáticas , Modelos Animais de Doenças , Estudos Longitudinais , Ratos , Ratos Wistar , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
19.
BMC Musculoskelet Disord ; 21(1): 806, 2020 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-33272239

RESUMO

BACKGROUND: A new locking screw technology, named variable fixation, has been developed aiming at promoting bone callus formation providing initial rigid fixation followed by progressive fracture gap dynamisation. In this study, we compared bone callus formation in osteotomies stabilized with standard locking fixation against that of osteotomies stabilized with variable fixation in an established tibia ovine model. METHODS: A 3 mm tibial transverse osteotomy gap was stabilized in three groups of six female sheep each with a locking plate and either 1) standard fixation in both segments (group LS) or 2) variable fixation in the proximal and standard fixation in the distal bone segment (group VFLS3) or 3) variable fixation in both segments (group VFLS6). The implantation site and fracture healing were compared between groups by means of radiologic, micro tomographic, biomechanical, and histological investigations. RESULTS: Compared to LS callus, VFLS3 callus was 40% larger and about 3% denser, while VFLS6 callus was 93% larger and its density about 7.2% lower. VFLS3 showed 65% and VFLS6 163% larger amount of callus at the cis-cortex. There wasn't a significant difference in the amount of callus at the cis and trans-cortex in groups featuring variable fixation only. Investigated biomechanical variables were not significantly different among groups and histology showed comparable good healing in all groups. Tissues adjacent to the implants did not show any alteration of the normal structure in all groups. CONCLUSIONS: Variable fixation promoted the formation of a larger amount of bone callus, equally distributed at the cis and trans cortices. The histological and biomechanical properties of the variable fixation callus were equivalent to those of the standard fixation callus. The magnitude of variable fixation had a biological effect on the formation of bone callus. At the implantation site, the usage of variable fixation did not raise additional concerns with respect to standard fixation. The formation of a larger amount of mature callus suggests that fractures treated with variable fixation might have a higher probability to bridge the fracture gap. The conditions where its usage can be most beneficial for patients needs to be clinically defined.


Assuntos
Fixação Interna de Fraturas , Fraturas da Tíbia , Animais , Fenômenos Biomecânicos , Placas Ósseas , Parafusos Ósseos , Calo Ósseo/diagnóstico por imagem , Feminino , Consolidação da Fratura , Humanos , Osteotomia , Ovinos
20.
J Bone Joint Surg Am ; 102(Suppl 2): 91-98, 2020 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-32530877

RESUMO

BACKGROUND: Heterotopic ossification (HO) is a known finding after total hip arthroplasty (THA) that potentially affects clinical outcomes. The incidence of HO is related to various factors, including soft-tissue trauma, postoperative medication, surgical approach, and the surgeon's experience. Because use of the direct anterior approach (DAA) is gaining popularity, we aimed (1) to determine the incidence of HO after DAA-THA and (2) to evaluate the impact of HO on patient-reported outcomes (PROs). METHODS: We retrospectively reviewed 401 THAs (67 ± 10 years old, 210 men). The incidence and grade of HO were evaluated using the Brooker classification with anteroposterior and lateral radiographs. PROs were collected with use of the Oxford Hip Score (OHS) and the Core Outcome Measures Index (COMI)-Hip and were correlated with HO grades using generalized multiple regression models. RESULTS: The incidence of HO was 29.9% on the anteroposterior radiographic views (Brooker grade 1, 14.5%; grade 2, 11.1%; grade 3, 2.7%; and grade 4, 0.57%); the lateral radiographic views detected 9% additional HO when compared with the anteroposterior radiographs alone (Brooker grade 1, 8%, and grade 2, 1%). HO was more frequent in men. The American Society of Anesthesiologists (ASA) grade, age in women, and higher body mass index (BMI) in men were associated with higher HO grades. A transverse "bikini" incision was associated with a lower rate (4%) of Brooker grades 3 and 4 HO when compared with a longitudinal incision (12%). A Brooker grade of 0 to 3 HO did not impact outcomes. Only Brooker grade-4 HO was associated with significantly worse PROs; however, pain was not affected. CONCLUSIONS: Low-grade HO after DAA-THA is not uncommon, and its rate is underestimated when anteroposterior radiographic views are evaluated without lateral views. The risk factors for developing HO in our cohort were an ASA grade of >3, male sex (especially with a high BMI), older age in women, and use of longitudinal incisions. With use of the bikini incision, patients had lower rates of severe HO, but mostly senior surgeons with more experience performed their surgery. Age, ASA grade, experience level of the surgeon, and Brooker grade-4 HO all had a significant influence on PROs. Clinically important HO (Brooker grade 4) remains rare after DAA-THR. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia de Quadril/métodos , Ossificação Heterotópica/etiologia , Idoso , Artrografia , Artroplastia de Quadril/efeitos adversos , Feminino , Humanos , Masculino , Ossificação Heterotópica/diagnóstico por imagem , Ossificação Heterotópica/epidemiologia , Medidas de Resultados Relatados pelo Paciente , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...