Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biotechnol Prog ; 29(6): 1484-93, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24124128

RESUMO

This manuscript describes customization of copolymers to be used for polymer-driven protein purification in bioprocessing. To understand how copolymer customization can be used for fine-tuning, precipitation behavior was analyzed for five target antibodies (mAbs) and BSA as model impurity protein, at ionic strength similar to undiluted cell culture fluid. In contrast to the use of standardized homopolymers, customized copolymers, composed of 2-acrylamido-2-methylpropane sulfonic acid (AMPS) and 4-(acryloylamino)benzoic acid (ABZ), exhibited antibody precipitation yields exceeding 90%. Additionally, copolymer average molecular weight (Mw ) was varied and its influence on precipitation yield and contaminant coprecipitation was investigated. Results revealed copolymer composition as the major driving force for precipitation selectivity, which was also dependent on protein hydrophobicity. By adjusting ABZ content and Mw of the precipitant for each of the mAbs, conditions were found that allowed for high precipitation yield and selectivity. These findings may open up new avenues for using polymers in antibody purification processes.


Assuntos
Ácido 4-Aminobenzoico/química , Acrilamidas/química , Alcanossulfonatos/química , Anticorpos Monoclonais/isolamento & purificação , Polímeros/química , Anticorpos Monoclonais/química , Técnicas de Cultura de Células , Precipitação Química , Humanos , Concentração Osmolar
2.
J Biotechnol ; 166(4): 206-11, 2013 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-23732833

RESUMO

Technical-scale crystallization of therapeutic proteins may not only allow for a significant cost-reduction in downstream processing, but also enable new applications, e.g., the use of crystal suspensions for subcutaneous drug delivery. In this work, the crystallization of the antigen-binding fragment FabC225 was studied. First, vapor diffusion crystallization conditions from the literature were transferred to 10µL-scale microbatch experiments. A phase diagram was developed in order to identify the crystallization window. The conditions obtained from the microbatch experiments were subsequently transferred to parallelized 5mL-scale stirred-tank crystallizers. This scalable and reproducible agitated crystallization system allowed for an optimization of the crystallization process based on quantitative measurements. The optimized crystallization process resulted in an excellent yield of 99% in less than 2h by increasing the concentration of the crystallization agent ammonium sulfate during the process. The successful scalability of the Fab fragment crystallization process to 100mL-scale crystallizers based on geometric similarity was demonstrated. A favorable crystal size distribution was obtained. Furthermore, a wash step was introduced in order to remove unfavorable low-molecular substances from the crystals.


Assuntos
Fragmentos Fab das Imunoglobulinas/química , Sulfato de Amônio/química , Precipitação Química , Cristalização/métodos , Fragmentos Fab das Imunoglobulinas/isolamento & purificação , Movimento (Física) , Concentração Osmolar , Tamanho da Partícula , Suspensões , Fatores de Tempo
3.
Biotechnol Bioeng ; 110(11): 2915-27, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23637026

RESUMO

We present a feasibility study for an antibody capturing process from clarified cell culture fluid using semi-selective protein precipitation with salt-tolerant copolymers. Protein precipitation is mediated by hydrophobic and electrostatic interactions with the copolymer that can be customized for the respective target. Precipitation yield with different copolymers at ionic strength of 2-22.5 mS cm⁻¹ and pH 5.0-pH 5.7 was evaluated using pure monoclonal antibody solutions. Optimized parameters were used to elucidate yield and purity of various antibodies precipitated at physiological conditions from cell culture fluid of CHO, NS0, and SP2/0 cell culture fluid. Precipitated protein was easily redissolved in small volume, enabling concentrating monoclonal antibodies (mAb) more than 40-fold and up to 100-fold, while residual polymer was removed to >98% using cationic polymer attached to silica flakes. mAb recovery of >90% and host cell protein clearance of >80% were achieved, not requiring any pre-dilution of cell culture fluid. Precipitation showed no impact on mAb binding affinity when compared to non-precipitated mAb. The obtained yield and purity were lower compared to a protein A based purification and loss of mAb was factor 1.5-3.0 higher. Yet, for high titer mAb purification processes being implemented in the future, precipitation is an attractive option due to its ease of scalability and cost-effectiveness.


Assuntos
Anticorpos/isolamento & purificação , Produtos Biológicos/isolamento & purificação , Fracionamento Químico/métodos , Precipitação Química , Tecnologia Farmacêutica/métodos , Animais , Técnicas de Cultura de Células/métodos , Linhagem Celular , Estudos de Viabilidade , Concentração de Íons de Hidrogênio , Proteínas Recombinantes/isolamento & purificação , Sais/química
4.
Biotechnol Bioeng ; 110(1): 252-9, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22811255

RESUMO

Process development in up- and downstream processing requires enhanced, non-time-consuming, and non-expensive monitoring techniques to track product purity, for example, the level of endotoxins, viral particles, and host cell proteins (HCPs). Currently, HCP amounts are measured by laborious and expensive HCP-enzyme-linked immunosorbent assay (ELISA) assays best suited for measuring HCP amounts in the low concentration regime. The measurement of higher HCP amounts using this method requires dilution steps, adding dilution errors to the measurement. In this work we evaluated the suitability of attenuated total reflection spectroscopy for HCP quantification in process development, using clarified cell culture fluid from monoclonal antibody producing Chinese hamster ovary-cells after treatment with different polyelectrolytes for semi-selective clarification. Forty undiluted samples were chosen for multivariate data analysis in the middle infrared range and predicted HCP-values were in good agreement with results obtained by an ELISA-assay, suggesting the suitability of this new method for HCP-quantification. As this method is able to quantify HCP titers ranging from approximately at least 20,000-200,000 ng mL(-1), it is suitable especially for monitoring of process development steps with higher HCP concentrations, omitting dilution errors associated with ELISA assays.


Assuntos
Biotecnologia/métodos , Proteínas/análise , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Animais , Anticorpos Monoclonais/isolamento & purificação , Células CHO , Cricetinae , Cricetulus , Eletrólitos/química , Ensaio de Imunoadsorção Enzimática , Espectrometria de Massas , Polímeros/química , Análise de Componente Principal , Proteínas/química , Proteínas Recombinantes/isolamento & purificação
5.
Biotechnol Prog ; 29(1): 265-74, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23074023

RESUMO

Production of recombinant proteins, e.g. antibodies, requires constant real-time monitoring to optimize yield and quality attributes and to respond to changing production conditions, such as host cell protein (HCP) titers. To date, this monitoring of mammalian cell culture-based processes is done using laborious and time consuming enzyme-linked immunosorbent assays (ELISA), two-dimensional sodium dodecylsulphate polyacrylamide gel electrophoresis, and chromatography-based systems. Measurements are usually performed off-line, requiring regular sample withdrawal associated with increased contamination risk. As information is obtained retrospectively, the reaction time to adapt to process changes is too long, leading to lower yield and higher costs. To address the resulting demand for continuous online-monitoring systems, we present a feasibility study using attenuated total reflection spectroscopy (ATR) to monitor mAb and HCP levels of NS0 cell culture in situ, taking matrix effects into account. Fifty-six NS0 cell culture samples were treated with polyelectrolytes for semi-selective protein precipitation. Additionally, part of the samples was subjected to filtration prior to analysis, to change the background matrix and evaluate effects on chemometric quantification models. General models to quantify HCP and mAb in both filtered and unfiltered matrix showed lower prediction accuracy compared to models designed for a specific matrix. HCP quantification in the range of 2,000-55,000 ng mL(-1) using specific models was accurate for most samples, with results within the accepted limit of an ELISA assay. In contrast, mAb prediction was less accurate, predicting mAb in the range of 0.2-1.7 g L(-1) . As some samples deviated substantially from reference values, further investigations elucidating the suitability of ATR for monitoring are required.


Assuntos
Anticorpos Monoclonais/análise , Proteínas/análise , Animais , Células Cultivadas , Ensaio de Imunoadsorção Enzimática , Fluorescência , Camundongos , Análise de Componente Principal , Espectroscopia de Infravermelho com Transformada de Fourier
6.
J Chromatogr A ; 1084(1-2): 101-7, 2005 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-16114242

RESUMO

This work deals with the determination of total sulfite in wine. The determination combines an in-sample hydrogen peroxide oxidation of total sulfite in alkalized wine to sulfate with the separation and quantitation of the latter anion by zone electrophoresis (ZE) on-line coupled with isotachophoresis (ITP) on a column-coupling chip. Sample clean up, integrated into the ITP-ZE separation, eliminated wine matrix in an extent comparable to that provided by a highly selective distillation isolation of sulfite. At the same time, conductivity detection, employed to the detection of sulfate in the ZE stage of the ITP-ZE combination, provided for sulfate the concentration limit of detection corresponding to a 90 microg/l concentration of sulfite in the loaded sample (0.9 microl). Such a detectability allowed a reproducible quantitation of total sulfite when its concentration in wine was 15 mg/l. Formaldehyde binding of free sulfite in wine, included into the pre-column sample preparation, prevented an uncontrolled oxidation of this sulfite form. This step contributed to an unbiased determination of sulfate present in the original wine sample (this determination corrected for the concentration of sulfate determined in the sample after the peroxide oxidation of sulfite to the value equivalent to the total sulfite). The 99-101% recoveries of sulfite, determined for appropriately spiked wine samples, indicate a very good accuracy of the present method. Such a statement also supports excellent agreements of the results of quantitation based on the in-sample peroxide oxidation of the total sulfite (bound sulfite released at a high pH) with those in which this analyte was isolated from wine by distillation (bound sulfite released at a very low pH).


Assuntos
Eletroforese em Microchip/métodos , Sulfatos/análise , Sulfitos/análise , Vinho/análise , Peróxido de Hidrogênio/química , Oxirredução , Reprodutibilidade dos Testes
7.
J Sep Sci ; 28(9-10): 905-14, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16013816

RESUMO

An appropriate combination of separation mechanisms (simultaneous use of differences in pK values, host-guest complexations, and the ionic strength dependences of the actual ionic mobilities) provided zone electrophoresis (ZE) resolution of 22 organic and inorganic acids expected in wines on a polymethylmethacrylate (PMMA) chip with integrated conductivity detection. These separating conditions offered a framework for the ZE determination of organic acids responsible for some important organoleptic characteristics of wines (tartrate, malate, succinate, acetate, citrate, and lactate). The ZE procedure developed in this context is simple and rapid (ca. 10 minutes' analysis time), while affording reproducible migration and quantitation data for the acids. For example, 0.8-2.0% RSD values characterized the migration times of the acids for 25 repeated ZE runs with the same sample carried out in 5 days in the background electrolyte solution prepared freshly on a daily basis, while 3-5% RSD values were typical for the accompanying peak area data. The concentration ranges within which the acids of analytical interest could be determined in one ZE run covered all wine samples included in our study (100-400-fold sample dilutions were needed to work under the conditions corresponding to the validities of the calibration data). 90-110% recoveries of the acids as obtained repeatedly for one of the reference wine samples used in our experiments indicate a good predisposition of the present method to provide accurate analytical results. This statement also supports the results from the determination of the acids in reference wine samples with claimed concentrations of malic (five samples), tartaric (one sample), and lactic (one sample) acids.


Assuntos
Ácidos/análise , Eletroforese Capilar/métodos , Compostos Orgânicos/análise , Vinho/análise
8.
Electrophoresis ; 25(21-22): 3865-74, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15565671

RESUMO

This feasibility study deals with the separations of proteins by an on-line combination of zone electrophoresis (ZE) with isotachophoresis (ITP) on a poly(methylmethacrylate) column-coupling (CC) chip with integrated conductivity detection. ITP and ZE provided specific analytical functions while performing the cationic mode of the separation. ITP served, mainly, for concentrations of proteins and its concentrating power was beneficial in reaching a low dispersion transfer (injection) of the proteinous constituents, loaded on the CC chip in a 960 nL volume, into the ZE separation stage. This was complemented by an electrophoretically driven removal of the sample constituents migrating in front of the focused proteins from the separation system before the ZE separation. On the other hand, ZE served as a final separation (destacking) method and it was used under the separating conditions providing the resolutions and sensitive conductivity detections of the test proteins. In this way, ITP and ZE cooperatively contributed to low- or sub-microg/mL concentration detectabilities of proteins and their quantitations at 1-5 microg/mL concentrations. However, a full benefit in concentration detectabilities of proteins, expected from the use of the ITP-ZE combination, was not reached in this work. Small adsorption losses of proteins and detection disturbances in the ZE stage of separation, very likely due to trace constituents concentrated by ITP, appear to set limits in the detection of proteins in our experiments. The ITP-ZE separations were carried out in a hydrodynamically closed separation compartment of the chip with suppressed hydrodynamic and electroosmotic flows of the electrolyte solutions. Such transport conditions, minimizing fluctuations of the migration velocities of the separated constituents, undoubtedly contributed to highly reproducible migrations of the separated proteins (fluctuations of the migration time of a particular protein were typically 0.5% RSD in repeated ITP-ZE runs).


Assuntos
Eletroforese em Microchip/instrumentação , Proteínas/isolamento & purificação , Animais , Eletroforese em Microchip/métodos , Desenho de Equipamento , Estudos de Viabilidade , Humanos , Polimetil Metacrilato
9.
J Chromatogr A ; 1051(1-2): 33-42, 2004 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-15532553

RESUMO

This feasibility study deals with column switching in zone electrophoresis (ZE) separations on a column coupling (CC) chip. The column switching implemented into the ZE separations an on-chip sample clean up applicable for both the multicomponent and high salinity samples. In addition, complemented by different separation mechanisms in the coupled columns (channels), it provided benefits of two-dimensional separations. Properly timed column switching gave column-to-column transfers of the analytes, characterized by 99-102% recoveries, delivered to the second separation stage on the chip the analyte containing fractions contaminated only with minimum amounts of the matrix constituents. A diffusion driven transport of the matrix constituents to the second channel of the chip (due to direct contacts of the electrolyte solutions in the bifurcation region), representing 0.1-0.2% of the loaded sample constituents, was found to accompany the sample clean up performed on the CC chip. This source of potential disturbances to the separation in the second channel, however, is not detectable in a majority of practical situations. With respect to a 900 nl volume of the sample channel on the CC chip, the electric field and isotachophoresis (ITP) stackings were employed to minimize the injection dispersion in the separations and concentrate the analytes. Here, the column switching, removing a major part of the stacker from the separation system, provided a tool effective in a control of the destacking of analytes. Highly reproducible ZE separations as attained in this work also for the chip-to-chip and equipment-to-equipment frames can be ascribed, at least in part, to suppressions of electroosmotic and hydrodynamic flows of the solutions in which the separations were performed.


Assuntos
Eletroforese/métodos , Procedimentos Analíticos em Microchip
10.
J Chromatogr A ; 1026(1-2): 31-9, 2004 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-14763730

RESUMO

This work deals with the determination of free sulfite in wine by zone electrophoresis (ZE) with on-line isotachophoresis (ITP) sample pretreatment on a column-coupling (CC) chip with conductivity detection. A rapid pre-column conversion of sulfite to hydroxymethanesulfonate (HMS), to minimize oxidation losses of the analyte, was included into the developed analytical procedure, while ITP and ZE were responsible for specific analytical tasks in the separations performed on the CC chip. ITP, for example, eliminated the sample matrix from the separation compartment and, at the same time, provided a selective concentration of HMS before its transfer to the ZE stage of the separation. On the other hand, ZE served as a final separation (destacking) method and it was used under the separating conditions favoring a sensitive conductivity detection of HMS. In this way, ITP and ZE cooperatively contributed to a 900 microg/l concentration detectability for sulfite as attained for a 60 nl load of wine (a 15-fold wine dilution and the use of a 0.9 microl sample injection channel of the chip) and, consequently, to the determination of free sulfite when this was present in wine at the concentrations as low as 3 mg/l. The separations were carried out in a closed separation compartment of the chip with suppressed hydrodynamic and electroosmotic flows. Such transport conditions, minimizing fluctuations of the migration velocities of the separated constituents, made a frame for precise migration and quantitation data as achieved for HMS in both the model and wine samples. Ninety percent recoveries, as typically obtained for free sulfite in wine samples, indicate promising potentialities of the present method as far as the accuracies of the provided analytical results are concerned.


Assuntos
Eletroforese/instrumentação , Eletroforese/métodos , Manejo de Espécimes/métodos , Sulfitos/análise , Sulfitos/química , Vinho/análise , Calibragem , Formaldeído/química , Reprodutibilidade dos Testes
11.
Electrophoresis ; 24(12-13): 2208-2227, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12858394

RESUMO

This review focuses on capillary electrophoretic separations performed on capillary electrophoresis chips (CE chips) with hydrodynamically closed separation systems in a context with transport processes (electroosmotic flow (EOF)) and hydrodynamic flow (HDF)) that may accompany the separations in these devices. It also reflects some relevant works dealing with conventional CE operating under such hydrodynamic conditions. The use of zone electrophoresis (ZE), isotachophoresis (ITP) and their on-line combination (ITP-ZE) on the single-column and column-coupling CE chips with the closed separation systems and related problems are key topics of the review. Some attention is paid to sample pretreatment in the separations performed on the CE chips. Here, mainly potentialities of the ITP-ZE combination in trace analysis applications of the miniaturized systems are discussed in a broader extent. Links between the ZE separation and detection provide a frame for the discussion of current status of the detection on the CE chips. Analytical applications illustrate potentialities of the CE chips operating with the closed separation systems (suppressed HDF and EOF) to the determination of small ions present in various matrices by ZE, ITP and ITP-ZE.


Assuntos
Eletroforese Capilar/instrumentação , Semicondutores , Eletroforese Capilar/métodos
12.
J Chromatogr A ; 990(1-2): 179-88, 2003 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-12685596

RESUMO

This work deals with zone electrophoresis (ZE) separations of proteins on a poly(methyl methacrylate) chip with integrated conductivity detection. Experiments were performed in the cationic mode of the separation (pH 2.9) with a hydrodynamically closed separation compartment and suppressed electroosmotic flow. The test proteins reached the detector in less than 10 min under these working conditions and their migration times characterized excellent repeatabilities (0.1-0.6% RSD values). The chip-to-chip agreements of the migration times, evaluated from the ZE runs performed on three chips, were within 1.5%. The conductivity detection provided for protein, loaded on the chip at 10-1000 microg/ml concentrations, detection responses were characterized by 1-5% RSD values of their peak areas. Such migration and detection performances made a frame for reproducible baseline separations of a five-constituent mixture (cytochrome c, avidin, conalbumin, human hemoglobin and trypsin inhibitor). On the other hand, a high sample injection channel/separation compartment volume ratio of the chip (500 nl/8500 nl) restricted the resolution of proteins of very close effective mobilities in spite of the fact that in the initial phase of the separation an electric field stacking was applied. A maximum macroconstituent/trace constituent ratio attainable for proteins on the chip was assessed for cytochrome c (quantifiable when its concentration in the loaded sample was 10 microg/ml) and apo-transferrin (containing a trace constituent migrating in the position of cytochrome c detectable when the load of apo-transferrin was 2000 microg/ml). This assessment indicated that a ratio of 1000:1 is attainable with the aid of conductivity detection on the present chip.


Assuntos
Eletroforese/instrumentação , Polimetil Metacrilato/química , Proteínas/isolamento & purificação , Condutividade Elétrica , Eletroquímica
13.
Electrophoresis ; 23(20): 3630-7, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12412134

RESUMO

The use of capillary zone electrophoresis (CZE) on-line coupled with isotachophoresis (ITP) sample pretreatment (ITP-CZE) on a poly(methylmethacrylate) chip, provided with two separation channels in the column-coupling (CC) arrangement and on-column conductivity detection sensors, to the determination of bromate in drinking water was investigated. Hydrodynamic and electroosmotic flows of the solution in the separation compartment of the chip were suppressed and electrophoresis was a dominant transport process in the ITP-CZE separations. A high sample load capacity, linked with the use of ITP in this combination, made possible loading of the samples by a 9.2 microL sample injection channel of the chip. In addition, bromate was concentrated by a factor of 10(3) or more in the ITP stage of the separation and, therefore, its transfer to the CZE stage characterized negligible injection dispersion. This, along with a favorable electric conductivity of the carrier electrolyte solution, contributed to a 20 nmol/L (2.5 ppb) limit of detection for bromate in the CZE stage. Sample cleanup, integrated into the ITP stage, effectively complemented such a detection sensitivity and bromate could be quantified in drinking water matrices when its concentration was 80 nmol/L (10 ppb) or slightly less while the concentrations of anionic macroconstituent (chloride, sulfate, nitrate) in the loaded sample corresponding to a 2 mmol/L (70 ppm) concentration of chloride were still tolerable. The samples containing macroconstituents at higher concentrations required appropriate dilutions and, consequently, bromate in these samples could be directly determined only at proportionally higher concentrations.


Assuntos
Bromatos/análise , Eletroforese Capilar/métodos , Eletroforese/métodos , Abastecimento de Água/análise , Bromatos/isolamento & purificação , Desinfetantes/análise , Condutividade Elétrica , Estudos de Viabilidade
14.
Electrophoresis ; 23(5): 774-81, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11891711

RESUMO

The use of a poly(methylmethacrylate) capillary electrophoresis chip, provided with a high sample load capacity separation system (a 8500 nL separation channel coupled to a 500 nL sample injection channel) and a pair of on-chip conductivity detectors, for zone electrophoresis (ZE) determination of oxalate in urine was studied. Hydrodynamic and electroosmotic flows of the solution in the separation compartment of the chip were suppressed and electrophoresis was a dominant transport process in the separations performed on the chip. A low pH of the carrier electrolyte (4.0) provided an adequate selectivity in the separation of oxalate from anionic urine constituents and, at the same time, also a sufficient sensitivity in its conductivity detection. Under our working conditions, this anion could be detected at a 8 x 10(-8) mol/L concentration also in samples containing chloride (a major anionic constituent of urine) at 3.5 x 10(-3) mol/L concentrations. Such a favorable analyte/matrix concentration ratio (in part, attributable to a transient isotachophoresis stacking in the initial phase of the separation) made possible accurate and reproducible (typically, 2-5% relative standard deviation (RSD) values of the peak areas of the analyte in dependence on its concentration in the sample) determination of oxalate in 500 nL volumes of 20-100-fold diluted urine samples. Short analysis times (about 280 s), no sample pretreatment (not considering urine dilution) and reproducible migration times of this analyte (0.5-1.0% RSD values) were characteristic for ZE on the chip. This work indicates general potentialities of the present chip design in rapid ZE analysis of samples containing the analyte(s) at high ionic matrix/analyte concentration ratios.


Assuntos
Oxalatos/urina , Condutividade Elétrica , Eletroforese Capilar/métodos , Humanos , Microquímica/métodos , Polimetil Metacrilato
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...