Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Mol Sci ; 24(13)2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37446168

RESUMO

The use of X-rays for non-invasive imaging has a long history, which has resulted in several well-established methods in preclinical as well as clinical applications, such as tomographic imaging or computed tomography. While projection radiography provides anatomical information, X-ray fluorescence analysis allows quantitative mapping of different elements in samples of interest. Typical applications so far comprise the identification and quantification of different elements and are mostly located in material sciences, archeology and environmental sciences, whereas the use of the technique in life sciences has been strongly limited by intrinsic spectral background issues arising in larger objects, so far. This background arises from multiple Compton-scattering events in the objects of interest and strongly limits the achievable minimum detectable marker concentrations. Here, we review the history and report on the recent promising developments of X-ray fluorescence imaging (XFI) in preclinical applications, and provide an outlook on the clinical translation of the technique, which can be realized by reducing the above-mentioned intrinsic background with dedicated algorithms and by novel X-ray sources.


Assuntos
Tomografia Computadorizada por Raios X , Tomografia , Raios X , Radiografia , Tomografia Computadorizada por Raios X/métodos , Imagem Óptica , Imagens de Fantasmas
2.
Sensors (Basel) ; 23(14)2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37514752

RESUMO

Bioluminescence imaging (BLI) is a widely used technique in preclinical scientific research, particularly in the development of mRNA-based medications and non-invasive tumor diagnostics. It has become an essential tool in current science. However, the current state of bioluminescence imaging is primarily qualitative, making it challenging to obtain quantitative measurements and to draw accurate conclusions. This fact is caused by the unique properties of optical photons and tissue interactions. In this paper, we propose an experimental setup and Geant4-simulations to gain a better understanding of the optical properties and processes involved in bioluminescence imaging. Our goal is to advance the field towards more quantitative measurements. We will discuss the details of our experimental setup, the data we collected, the outcomes of the Geant4-simulations, and additional information on the underlying physical processes.


Assuntos
Diagnóstico por Imagem , Fótons , Imagens de Fantasmas , Diagnóstico por Imagem/métodos , Método de Monte Carlo , Medições Luminescentes/métodos
3.
Sci Rep ; 13(1): 11505, 2023 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-37460665

RESUMO

The infiltration of immune cells into sites of inflammation is one key feature of immune mediated inflammatory diseases. A detailed assessment of the in vivo dynamics of relevant cell subtypes could booster the understanding of this disease and the development of novel therapies. We show in detail how advanced X-ray fluorescence imaging enables such quantitative in vivo cell tracking, offering solutions that could pave the way beyond what other imaging modalities provide today. The key for this achievement is a detailed study of the spectral background contribution from multiple Compton scattering in a mouse-scaled object when this is scanned with a monochromatic pencil X-ray beam from a synchrotron. Under optimal conditions, the detection sensitivity is sufficient for detecting local accumulations of the labelled immune cells, hence providing experimental demonstration of in vivo immune cell tracking in mice.


Assuntos
Rastreamento de Células , Tomografia Computadorizada por Raios X , Animais , Camundongos , Tomografia Computadorizada por Raios X/métodos , Raios X , Radiografia , Imagem Óptica
4.
Phys Med ; 104: 174-187, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36463582

RESUMO

At the Photo Injector Test facility at DESY in Zeuthen (PITZ), an R&D platform for electron FLASH and very high energy electron radiation therapy and radiation biology is being prepared (FLASHlab@PITZ). The beam parameters available at PITZ are worldwide unique. They are based on experiences from 20 + years of developing high brightness beam sources and an ultra-intensive THz light source demonstrator for ps scale electron bunches with up to 5 nC bunch charge at MHz repetition rate in bunch trains of up to 1 ms length, currently 22 MeV (upgrade to 250 MeV planned). Individual bunches can provide peak dose rates up to 1014 Gy/s, and 10 Gy can be delivered within picoseconds. Upon demand, each bunch of the bunch train can be guided to a different transverse location, so that either a "painting" with micro beams (comparable to pencil beam scanning in proton therapy) or a cumulative increase of absorbed dose, using a wide beam distribution, can be realized at the tumor. Full tumor treatment can hence be completed within 1 ms, mitigating organ movement issues. With extremely flexible beam manipulation capabilities, FLASHlab@PITZ will cover the current parameter range of successfully demonstrated FLASH effects and extend the parameter range towards yet unexploited short treatment times and high dose rates. A summary of the plans for FLASHlab@PITZ and the status of its realization will be presented.


Assuntos
Elétrons , Neoplasias , Humanos , Radiobiologia
5.
Antioxidants (Basel) ; 11(8)2022 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-36009252

RESUMO

X-ray fluorescence (XRF) imaging is a highly sensitive non-invasive imaging method for detection of small element quantities in objects, from human-sized scales down to single-cell organelles, using various X-ray beam sizes. Our aim was to investigate the cellular uptake and distribution of Q10, a highly conserved coenzyme with antioxidant and bioenergetic properties. Q10 was labeled with iodine (I2-Q10) and individual primary human skin cells were scanned with nano-focused beams. Distribution of I2-Q10 molecules taken up inside the screened individual skin cells was measured, with a clear correlation between individual Q10 uptake and cell size. Experiments revealed that labeling Q10 with iodine causes no artificial side effects as a result of the labeling procedure itself, and thus is a perfect means of investigating bioavailability and distribution of Q10 in cells. In summary, individual cellular Q10 uptake was demonstrated by XRF, opening the path towards Q10 multi-scale tracking for biodistribution studies.

6.
ACS Nano ; 16(8): 12941-12951, 2022 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-35938921

RESUMO

Matricaria chamomilla flowers were incubated with gold nanoparticles of different sizes ranging from 1.4 to 94 nm. After different incubation times of 6, 12, 24, and 48 h, the gold distribution in the flowers was destructively measured by inductively coupled plasma mass spectrometry (ICP-MS) and non-destructively measured by X-ray fluorescence imaging (XFI) with high lateral resolution. As a control, the biodistribution of iodine ions or iodine-containing organic molecules (iohexol) was determined, in order to demonstrate the feasibility of mapping the distribution of several elements in parallel. The results show a clear size-dependent transport of the nanoparticles. In addition, the surface chemistry also plays a decisive role in disposition. Only the 1.6 nm nanoparticles coated with acetylcysteine could be efficiently transported through the stem of the flowers into the petals. In this case, almost 80% of the nanoparticles which were found within each flower were located in the petals. The study also highlights the potential of XFI for in situ recording of in vivo analyte biodistribution.


Assuntos
Iodo , Matricaria , Nanopartículas Metálicas , Ouro/química , Nanopartículas Metálicas/química , Distribuição Tecidual , Raios X , Ligantes , Espectrometria de Massas , Imagem Óptica , Tamanho da Partícula
7.
Int J Mol Sci ; 23(9)2022 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-35563064

RESUMO

Trace elements, functionalized nanoparticles and labeled entities can be localized with sub-mm spatial resolution by X-ray fluorescence imaging (XFI). Here, small animals are raster scanned with a pencil-like synchrotron beam of high energy and low divergence and the X-ray fluorescence is recorded with an energy-dispersive detector. The ability to first perform coarse scans to identify regions of interest, followed by a close-up with a sub-mm X-ray beam is desirable, because overall measurement time and X-ray dose absorbed by the (biological) specimen can thus be minimized. However, the size of X-ray beams at synchrotron beamlines is usually strongly dependent on the actual beamline setup and can only be adapted within specific pre-defined limits. Especially, large synchrotron beams are non-trivial to generate. Here, we present the concept of graphite-based, convex reflection optics for the one-dimensional enlargement of a 1 mm wide synchrotron beam by a factor of 5 to 10 within a 1 m distance. Four different optics are tested and characterized and their reflection properties compared to ray tracing simulations. The general shape and size of the measured reflection profiles agree with expectations. Enhancements with respect to homogeneity and efficiency can be expected with improved optics manufacturing. A mouse phantom is used for a proof-of-principle XFI experiment demonstrating the applicability of coarse and fine scans with the suggested optics design.


Assuntos
Óptica e Fotônica , Síncrotrons , Animais , Camundongos , Imagem Óptica , Imagens de Fantasmas , Raios X
8.
Sci Rep ; 12(1): 2903, 2022 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-35190621

RESUMO

X-ray fluorescence imaging (XFI) is a non-invasive detection method of small quantities of elements, which can be excited to emit fluorescence x-ray photons upon irradiation with an incident x-ray beam. In particular, it can be used to measure nanoparticle uptake in cells and tissue, thus making it a versatile medical imaging modality. However, due to substantially increased multiple Compton scattering background in the measured x-ray spectra, its sensitivity severely decreases for thicker objects, so far limiting its applicability for tracking very small quantities under in-vivo conditions. Reducing the detection limit would enable the ability to track labeled cells, promising new insights into immune response and pharmacokinetics. We present a synchrotron-based approach for reducing the minimal detectable marker concentration by demonstrating the feasibility of XFI for measuring the yet inaccessible distribution of the endogenous iodine in murine thyroids under in-vivo conform conditions. This result can be used as a reference case for the design of future preclinical XFI applications as mentioned above.


Assuntos
Iodo/metabolismo , Espectrometria por Raios X/métodos , Glândula Tireoide/metabolismo , Animais , Estudos de Viabilidade , Limite de Detecção , Camundongos Endogâmicos C57BL , Glândula Tireoide/diagnóstico por imagem
9.
Cancers (Basel) ; 13(22)2021 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-34830917

RESUMO

The growing field of cellular therapies in regenerative medicine and oncology calls for more refined diagnostic tools that are able to investigate and monitor the function and success of said therapies. X-ray Fluorescence Imaging (XFI) can be applied for molecular imaging with nanoparticles, such as gold nanoparticles (GNPs), which can be used in immune cell tracking. We present a Monte Carlo simulation study on the sensitivity of detection and associated radiation dose estimations in an idealized setup of XFI in human-sized objects. Our findings demonstrate the practicability of XFI in human-sized objects, as immune cell tracking with a minimum detection limit of 4.4 × 105 cells or 0.86 µg gold in a cubic volume of 1.78 mm3 can be achieved. Therefore, our results show that the current technological developments form a good basis for high sensitivity XFI.

10.
Int J Mol Sci ; 22(16)2021 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-34445443

RESUMO

Immunotherapy has been a breakthrough in cancer treatment, yet only a subgroup of patients responds to these novel drugs. Parameters such as cytotoxic T-cell infiltration into the tumor have been proposed for the early evaluation and prediction of therapeutic response, demanded for non-invasive, sensitive and longitudinal imaging. We have evaluated the feasibility of X-ray fluorescence imaging (XFI) to track immune cells and thus monitor the immune response. For that, we have performed Monte Carlo simulations using a mouse voxel model. Spherical targets, enriched with gold or palladium fluorescence agents, were positioned within the model and imaged using a monochromatic photon beam of 53 or 85 keV. Based on our simulation results, XFI may detect as few as 730 to 2400 T cells labelled with 195 pg gold each when imaging subcutaneous tumors in mice, with a spatial resolution of 1 mm. However, the detection threshold is influenced by the depth of the tumor as surrounding tissue increases scattering and absorption, especially when utilizing palladium imaging agents with low-energy characteristic fluorescence photons. Further evaluation and conduction of in vivo animal experiments will be required to validate and advance these promising results.


Assuntos
Simulação por Computador , Imunoterapia , Nanopartículas Metálicas , Neoplasias/diagnóstico por imagem , Imagem Óptica/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Estudos de Viabilidade , Fluorescência , Ouro , Masculino , Camundongos , Camundongos Nus , Método de Monte Carlo , Neoplasias/terapia , Paládio
11.
Int J Mol Sci ; 22(7)2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33916283

RESUMO

Quantitative cellular in vitro nanoparticle uptake measurements are possible with a large number of different techniques, however, all have their respective restrictions. Here, we demonstrate the application of synchrotron-based X-ray fluorescence imaging (XFI) on prostate tumor cells, which have internalized differently functionalized gold nanoparticles. Total nanoparticle uptake on the order of a few hundred picograms could be conveniently observed with microsamples consisting of only a few hundreds of cells. A comparison with mass spectroscopy quantification is provided, experimental results are both supported and sensitivity limits of this XFI approach extrapolated by Monte-Carlo simulations, yielding a minimum detectable nanoparticle mass of just 5 pg. This study demonstrates the high sensitivity level of XFI, allowing non-destructive uptake measurements with very small microsamples within just seconds of irradiation time.


Assuntos
Ouro , Nanopartículas , Imagem Óptica , Espectrometria por Raios X , Humanos , Células Tumorais Cultivadas
12.
Sci Rep ; 8(1): 16561, 2018 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-30410002

RESUMO

Accurate in vivo localisation of minimal amounts of functionalised gold-nanoparticles, enabling e.g. early-tumour diagnostics and pharmacokinetic tracking studies, requires a precision imaging system offering very high sensitivity, temporal and spatial resolution, large depth penetration, and arbitrarily long serial measurements. X-ray fluorescence imaging could offer such capabilities; however, its utilisation for human-sized scales is hampered by a high intrinsic background level. Here we measure and model this anisotropic background and present a spatial filtering scheme for background reduction enabling the localisation of nanoparticle-amounts as reported from small-animal tumour models. As a basic application study towards precision pharmacokinetics, we demonstrate specific localisation to sites of disease by adapting gold-nanoparticles with small targeting ligands in murine spinal cord injury models, at record sensitivity levels using sub-mm resolution. Both studies contribute to the future use of molecularly-targeted gold-nanoparticles as next-generation clinical diagnostic and pharmacokinetic tools.


Assuntos
Fibronectinas/metabolismo , Ouro/química , Peptídeos/administração & dosagem , Traumatismos da Medula Espinal/diagnóstico por imagem , Animais , Modelos Animais de Doenças , Feminino , Fibronectinas/química , Polarização de Fluorescência , Humanos , Nanopartículas Metálicas/administração & dosagem , Nanopartículas Metálicas/química , Camundongos , Tamanho da Partícula , Peptídeos/química , Peptídeos/farmacocinética , Imagens de Fantasmas , Traumatismos da Medula Espinal/tratamento farmacológico , Síncrotrons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...