Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Vasc Interv Radiol ; 32(7): 1011-1015.e1, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33831561

RESUMO

PURPOSE: To evaluate the utility of computed tomography (CT) angiography before transarterial embolization (TAE) in predicting TAE's technical success for type II endoleaks (T2ELs). MATERIALS AND METHODS: Fifty-eight patients (mean age, 74.4 years; range, 46-89 years) who underwent attempted TAE for T2EL from July 2014 to August 2019 and underwent CT angiography before the procedure were included. Each CT angiography result was assessed for a feeding artery that was traceable over its entire course from either the superior mesenteric artery or the internal iliac artery to the endoleak cavity. TAE was performed using coils and was considered technically successful if embolization of the endoleak cavity and feeding artery was performed. The technical success rates were compared between patients with and without traceable feeding arteries. RESULTS: A fully traceable feeding artery supplying 75% (44/59) of endoleaks in the cohort was identified. TAE was technically successful in 95% (42/44) of these cases but only in 13% (2/15) of the cases without a fully traceable feeding artery (P < .001). When the inferior mesenteric artery was the feeding artery, it was always fully traceable, and TAE was technically successful in 100% (33/33) of the cases. When a lumbar artery was the feeding artery, it was fully traceable in only 42% (11/26) of the cases. When the lumbar artery was not fully traceable, TAE was technically successful in only 13% (2/15) of the cases. CONCLUSIONS: The traceability of a feeding artery over its entire course to an endoleak cavity using CT angiography was associated with TAE's technical success. Lumbar feeding arteries were less likely to be fully traceable. TAE's high failure rate when the feeding artery was not fully traceable suggests that translumbar embolization can be considered as an initial approach for theses patients.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Idoso , Angiografia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Angiografia por Tomografia Computadorizada , Embolização Terapêutica/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/terapia , Procedimentos Endovasculares/efeitos adversos , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
2.
Tech Vasc Interv Radiol ; 21(2): 85-91, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29784126

RESUMO

The recognition of inferior vena cava filter related complications has motivated increased attentiveness in clinical follow-up of patients with inferior vena cava filters and has led to development of multiple approaches for retrieving filters that are challenging or impossible to remove using conventional techniques. Endobronchial forceps and excimer lasers are tools for designed to aid in complex inferior vena cava filter removals. This article discusses endobronchial forceps-assisted and excimer laser-assisted inferior vena cava filter retrievals.


Assuntos
Remoção de Dispositivo/instrumentação , Lasers de Excimer/uso terapêutico , Implantação de Prótese/instrumentação , Instrumentos Cirúrgicos , Filtros de Veia Cava , Veia Cava Inferior , Angiografia por Tomografia Computadorizada , Remoção de Dispositivo/métodos , Desenho de Equipamento , Humanos , Flebografia/métodos , Radiografia Intervencionista , Resultado do Tratamento , Veia Cava Inferior/diagnóstico por imagem
3.
Clin Nucl Med ; 42(3): 176-179, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28072623

RESUMO

PURPOSE: The objective of this study was to evaluate the effect of substituting 50% Isovue (Bracco Diagnostics Inc, Monroe Township, NJ) for sterile water on the delivery of Y resin microspheres (SIR-Spheres [Sirtex Medical Limited, Sydney, Australia]). MATERIALS AND METHODS: The authors retrospectively reviewed all SIR-Spheres radioembolizations at the authors' institution from January 1, 2011, to February 10, 2014. From January 1, 2011, to April 30, 2013, all users performed SIR-Spheres radioembolization per the manufacturer's original instructions using sterile water in the B and D lines and intermittently checking the progress of the embolization by injecting contrast via the B line. Beginning May 1, 2013, a modified technique using Isovue diluted 50% with saline in place of sterile water in both the B and D lines of the infusion set. The authors compared the prepared versus administered activity of Y SIR-Spheres, fluoroscopy time, administration time, and frequency of radioembolizations terminated for stasis when using water versus dilute contrast in the B and D lines. RESULTS: One hundred seventy-five radioembolizations were performed, 132 (75%) with water as the delivery medium and 43 (25%) with 50% contrast as delivery medium. The mean percentage of the Y activity administered was 98% with contrast versus 87% with water (P < 0.01). More than 95% of cases using contrast resulted in 90% or more delivery of the prepared Y activity versus 59% of cases with water (P < 0.01). For cases using water, 17% were terminated for stasis, whereas 2% (1 case) using contrast was terminated for stasis. The mean Y administration time was 7 minutes with contrast versus 22 minutes with water (P = 0.015). Excluding the 37 cases involving coil embolization, the mean fluoroscopy time was 8.3 minutes with contrast versus 11.5 minutes with water (P < 0.05). No complications occurred with the contrast method; however, there were 4 complications with water, including 1 nontarget gastric ulceration. CONCLUSIONS: Using dilute contrast as the delivery medium for SIR-Spheres resulted in a significantly greater percentage of the prepared activity administered to the patient with substantially shorter administration time. Termination for stasis occurred less often with dilute contrast. No complications were observed when using dilute contrast, which allowed continuous real-time monitoring of the Y microsphere administration.


Assuntos
Meios de Contraste , Embolização Terapêutica/métodos , Iopamidol , Neoplasias Hepáticas/terapia , Microesferas , Tumores Neuroendócrinos/terapia , Radioisótopos de Ítrio/administração & dosagem , Idoso , Braquiterapia , Neoplasias Colorretais/patologia , Sistemas de Liberação de Medicamentos , Feminino , Humanos , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Tumores Neuroendócrinos/secundário , Estudos Retrospectivos , Resultado do Tratamento , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA