Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Anesth Analg ; 130(2): 289-297, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31567325

RESUMO

BACKGROUND: The safety and efficacy of intrathecal drug delivery systems (IDDSs) for the treatment of cancer-related pain have been demonstrated in randomized controlled clinical trials (RCTs). Despite positive evidence for this therapy, IDDS remains underutilized to treat cancer pain. Real-world registry data augment existing safety and effectiveness data and are presented here to broaden awareness of this therapeutic option, needed for adequate cancer-related pain treatment, and as a viable tool addressing concerns with systemic opioid use. METHODS: This prospective, long-term, multicenter (United States, Western Europe, and Latin America) registry started in 2003 to monitor the performance of SynchroMed Infusion Systems. Patient-reported outcomes were added in 2013. Before data acquisition, all sites obtained Ethics Committee/Institutional Review Board approval and written patient consent. The study was registered (NCT01524276 at clinicaltrials.gov) before patients were enrolled. Patients who provided informed consent were enrolled in the registry at initial IDDS implant or replacement. RESULTS: Through July 2017, 1403 patients with cancer pain were enrolled and implanted. The average (minimum/maximum) age of patients was 59 years (13/93 years), with 56.6% female. The most frequent cancer types were lung, breast, colon/rectal, pancreatic, and prostate. The majority of patients whose registry follow-up ended (87%; 1141/1311) were followed through death, with 4.3% (n = 57) exiting due to device explant or therapy discontinuation; the remaining 113 (8.6%) discontinued for reasons such as transfer of care, lost to follow-up, and site closure. Pain scores within the cohort of patients providing baseline and follow-up data improved significantly at 6 (P = .0007; n = 103) and 12 (P = .0026; n = 55) months compared to baseline, with EuroQol with 5 dimensions (EuroQol-5D) scores showing significant improvement at 6 months (P = .0016; n = 41). Infection requiring surgical intervention (IDDS explant, replacement, pocket revision, irrigation and debridement, etc) was reported in 3.2% of patients. CONCLUSIONS: Adequate and improved pain control in patients with cancer, even in advanced stages, with concurrent quality of life maintenance is attainable. Results from this large-scale, multicenter, single-group cohort supplement existing RCT data that support IDDS as a safe and effective therapeutic option with a positive benefit-risk ratio in the treatment of cancer pain.


Assuntos
Dor do Câncer/tratamento farmacológico , Sistemas de Liberação de Medicamentos/métodos , Injeções Espinhais/métodos , Manejo da Dor/métodos , Vigilância de Produtos Comercializados/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Analgésicos Opioides/administração & dosagem , Dor do Câncer/diagnóstico , Sistemas de Liberação de Medicamentos/instrumentação , Seguimentos , Humanos , Bombas de Infusão Implantáveis , Pessoa de Meia-Idade , Medição da Dor/efeitos dos fármacos , Medição da Dor/métodos , Estudos Prospectivos , Sistema de Registros , Adulto Jovem
3.
Neuromodulation ; 19(8): 848-856, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27730704

RESUMO

OBJECTIVES: The ISPR was initially created to monitor the product performance of Medtronic implanted intrathecal drug infusion and spinal cord systems available in the United States. MATERIALS AND METHODS: Data were collected from 50 representative sites implanting and following patients with intrathecal drug delivery systems across the United States between August 7, 2003 and January 31, 2014. Device performance over time was estimated using life table survival methods. RESULTS: Of the 6093 patients enrolled in the ISPR, 3405 (55.9%) were female and 2675 (43.9%) were male, and 13 (0.2%) did not provide gender data. The average age at enrollment was 52.9 years (SD =17.6 years) and average follow-up time was 29.6 months. Currently, the estimates of device survival from pump-related events exceed 90% for all pump models across the applicable follow-up time points. The majority of product performance events were catheter-related. At 5 years of follow-up, all applicable catheter models, with the exception of revised not as designed or grafted not as designed catheters, had greater than 81% survival from catheter-related events. CONCLUSIONS: The ISPR is designed to serve as an ongoing source of system and device-related information with a focus on "real-world" safety and product performance. ISPR data continue to be used to guide future product development efforts aimed at improving product reliability and quality.


Assuntos
Analgésicos/administração & dosagem , Bombas de Infusão Implantáveis , Injeções Espinhais , Espasticidade Muscular/tratamento farmacológico , Adulto , Idoso , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Espasticidade Muscular/mortalidade , Sistema de Registros , Estudos Retrospectivos , Análise de Sobrevida , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...