Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Clin Res Cardiol ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748208

RESUMO

BACKGROUND: Right ventricular (RV) dysfunction in patients undergoing transcatheter aortic valve implantation (TAVI) for aortic stenosis (AS) has long been disregarded. We aimed to assess the predictive value of RV to pulmonary artery coupling (RV/PAc), defined as tricuspid annular plane systolic excursion to systolic pulmonary artery pressure, on mortality in different flow types of AS after TAVI. METHODS: All patients undergoing TAVI for AS at our centre between 2018 and 2020 were assessed; 862 patients were analysed. The cohort was dichotomized using a ROC analysis (cut-off 0.512 mm/mmHg), into 429 patients with preserved and 433 patients with reduced RV/PAc. RESULTS: Reduced RV/PAc was associated with male sex and a higher rate of comorbidities. Short-term VARC-3 endpoints and NYHA classes at follow-up were comparable. Reduced RV/PAc was associated with higher 2-year all-cause mortality (35.0% [30.3-39.3%] vs. 15.4% [11.9-18.7%], hazard ratio 2.5 [1.9-3.4], p < 0.001). Cardiovascular mortality was almost tripled. Results were consistent after statistical adjustment and in a multivariate model. Sub-analyses of AS flow types revealed lower RV/PAc in classical and paradoxical low-flow low-gradient AS, with the majority having reduced RV/PAc (74% and 59%). RV/PAc retained its predictive value in these subgroups. CONCLUSIONS: RV dysfunction defined by low RV/PAc is a strong mortality predictor after TAVI independent of flow group. It should be incorporated in future TAVI risk assessment.

2.
JACC Cardiovasc Interv ; 17(8): 1020-1028, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38658116

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an effective and safe therapy for severe aortic stenosis. Rapid or fast pacing is required for implantation, which can be performed via a pre-existing cardiac implantable electric device (CIED). However, safety data on CIEDs for pacing in TAVR are missing. OBJECTIVES: The aim of this study was to elucidate procedural safety and feasibility of internal pacing with a CIED in TAVR. METHODS: Patients undergoing TAVR with a CIED were included in this analysis. Baseline characteristics, procedural details, and complications according to Valve Academic Research Consortium 3 (VARC-3) criteria after TAVR were compared between both groups. RESULTS: A total of 486 patients were included. Pacing was performed using a CIED in 150 patients and a transient pacemaker in 336 patients. No differences in technical success according to VARC-3 criteria or procedure duration occurred between the groups. The usage of transient pacers for pacing was associated with a significantly higher bleeding rate (bleeding type ≥2 according to VARC-3-criteria; 2.0% vs 13.1%; P < 0.01). Furthermore, impairment of the CIED appeared in 2.3% of patients after TAVR only in the group in which pacing was performed by a transient pacer, leading to surgical revision of the CIED in 1.3% of all patients when transient pacemakers were used. CONCLUSIONS: Internal pacing using a CIED is safe and feasible without differences of procedural time and technical success and might reduce bleeding rates. Furthermore, pacing using a CIED circumvents the risk of lead dislocation. Our data provide an urgent call for the use of a CIED for pacing during a TAVR procedure in general.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Estimulação Cardíaca Artificial , Estudos de Viabilidade , Hospitais com Alto Volume de Atendimentos , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Resultado do Tratamento , Fatores de Tempo , Idoso , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Estudos Retrospectivos , Índice de Gravidade de Doença , Medição de Risco
4.
JACC Cardiovasc Interv ; 17(1): 76-87, 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38199755

RESUMO

BACKGROUND: Knowledge about atrial functional tricuspid regurgitation (afTR) in transcatheter aortic valve replacement (TAVR) patients is scarce. OBJECTIVES: The aim of the study was to analyze the association between the entity and the development of tricuspid regurgitation (TR) in patients undergoing TAVR for aortic stenosis and concomitant TR. METHODS: We analyzed patients undergoing TAVR for severe aortic stenosis from January 2013 to December 2020 and concomitant at least moderate TR at baseline. afTR was defined as enlargement of the right atrium in relation to the right ventricle. TR development after TAVR and 3-year all-cause mortality were evaluated. RESULTS: Out of 3,474 TAVR patients, we identified 420 patients with concomitant at least moderate TR. A total of 363 patients were included in the study, with 178 patients stratified in the afTR and 185 in the non-afTR group based on a receiver-operating characteristic curve cutoff of 1.132 of the right atrial/right ventricular area ratio. TR improvement after TAVR was observed in significantly less patients with afTR compared with non-afTR (31.1% vs 60.6%; P < 0.001). Multivariate regression analysis confirmed afTR as independent predictor for TR persistence (adjusted OR: 2.80; 95% CI: 1.66-4.76; P < 0.001). Moreover, afTR was associated with aggravation of TR after TAVR (17.0% vs 6.8%; P = 0.013). Three-year all-cause mortality was significantly higher in patients with persistence compared with patients with improvement of TR (P < 0.001). CONCLUSIONS: In TAVR patients, afTR is an independent predictor for TR persistence. Moreover, TR persistence is associated with increased 3-year all-cause mortality.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Átrios do Coração , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia
5.
Transl Psychiatry ; 14(1): 71, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38296973

RESUMO

The pandemic caused by SARS-CoV-2 impacted health systems globally, creating increased workload and mental stress upon health care workers (HCW). During the first pandemic wave (March to May 2020) in southern Germany, we investigated the impact of stress and the resilience to stress in HCW by measuring changes in hair concentrations of endocannabinoids, endocannabinoid-like compounds and cortisone. HCW (n = 178) recruited from multiple occupation and worksites in the LMU-University-Hospital in Munich were interviewed at four interval visits to evaluate mental stress associated with the COVID-19 pandemic. A strand of hair of up to 6 cm in length was sampled once in May 2020, which enabled retrospective individual stress hormone quantifications during that aforementioned time period. Perceived anxiety and impact on mental health were demonstrated to be higher at the beginning of the COVID-19 pandemic and decreased significantly thereafter. Resilience was stable over time, but noted to be lower in women than in men. The concentrations of the endocannabinoid anandamide (AEA) and the structural congeners N-palmitoylethanolamide (PEA), N-oleoylethanolamide (OEA) and N-stearoylethanolamide (SEA) were noted to have decreased significantly over the course of the pandemic. In contrast, the endocannabinoid 2-arachidonoylglycerol (2-AG) levels increased significantly and were found to be higher in nurses, laboratory staff and hospital administration than in physicians. PEA was significantly higher in subjects with a higher resilience but lower in subjects with anxiety. SEA was also noted to be reduced in subjects with anxiety. Nurses had significantly higher cortisone levels than physicians, while female subjects had significant lower cortisone levels than males. Hair samples provided temporal and measurable objective psychophysiological-hormonal information. The hair endocannabinoids/endocannabinoid-like compounds and cortisone correlated to each other and to professions, age and sex quite differentially, relative to specific periods of the COVID-19 pandemic.


Assuntos
COVID-19 , Cortisona , Resiliência Psicológica , Masculino , Humanos , Feminino , Endocanabinoides , Cortisona/análise , Pandemias , Estudos Retrospectivos , SARS-CoV-2 , Cabelo/química , Pessoal de Saúde
6.
Catheter Cardiovasc Interv ; 103(1): 186-193, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38140761

RESUMO

BACKGROUND: Patients undergoing transcatheter aortic valve implantation (TAVI) frequently have coronary artery disease requiring percutaneous coronary intervention (PCI). Usually, PCI and TAVI are performed in two separate procedures and current studies are investigating potential benefits regarding the order. However, the two interventions may also be performed simultaneously, thereby limiting the risk associated with repeated vascular access. Data evaluating benefit and harm of concomitant procedures are scarce. AIMS: Therefore, this study aimed to evaluate concomitant PCI (coPCI) in TAVI patients regarding Valve Academic Research Consortium 3 (VARC-3) endpoints and long-term mortality. METHODS: A total of 2233 consecutive TAVI patients from the EVERY-VALVE registry were analyzed according to the VARC-3 endpoint definitions. A total of 274 patients had undergone TAVI and concomitant PCI (coPCI group). They were compared to 226 TAVI patients who had received PCI within 60 days before TAVI in a stepwise approach (swPCI group) and to the remaining 1733 TAVI patients who had not undergone PCI recently (noPCI group). RESULTS: Overall median age was 81.4 years, median Society of Thoracic Surgeons score was 4.0%. Patients in the coPCI and in the swPCI group were predominantly male with reduced left-ventricular ejection fraction. Rates of VARC-3 composite endpoints technical success and 30-day device success were comparable between all three groups. Mortality rates at 3 years after TAVI were similar (coPCI, 34.2% vs. swPCI, 31.9% vs. noPCI, 34.0% p = 0.84). CONCLUSIONS: coPCI during TAVI seems comparable in a retrospective analysis. Compared to a stepwise approach, it has similar rates of composite endpoints technical success and device success as well as long-term mortality.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso de 80 Anos ou mais , Feminino , Estudos Retrospectivos , Volume Sistólico , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Função Ventricular Esquerda , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco
7.
Clin Res Cardiol ; 112(10): 1427-1435, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37337011

RESUMO

BACKGROUND: Cardiohepatic syndrome (CHS) has been identified as an important but underrecognized survival predictor in multiple cardiovascular disease entities. The objectives of this study were to evaluate the prevalence and prognostic value of CHS in patients undergoing TAVR for severe aortic stenosis (AS). METHODS: The study included patients with available laboratory parameters of hepatic function who underwent TAVR from July 2013 until December 2019 at our center. CHS was defined as an elevation of at least two of three laboratory cholestasis parameters above the upper limit of normal (bilirubin, alkaline phosphatase, and gamma glutamyl transferase). Study endpoints were three-year survival, technical and device failure (VARC 3), as well as New York Heart Association (NYHA) functional class at follow-up. RESULTS: Among a total of 953 analyzed patients (47.6% females, median age 80.0 [76.0-85.0] years) CHS was present in 212 patients (22.4%). In patients with vs. without CHS, rates of technical (6.1% vs. 8.4%, p = 0.29) and device failure (18.9% vs. 17.3%, p = 0.59) were comparable. NYHA functional class at baseline and follow-up was more severe in patients with CHS. Nevertheless, heart failure symptoms improved from baseline to follow-up irrespective of hepatic function. Three-year survival rates were significantly lower in patients with CHS (49.4 vs. 65.4%, p < 0.001). The predictive value of CHS persisted after adjustment in a multivariable analysis (hazard ratio 1.58, p < 0.01). CONCLUSION: In patients undergoing TAVR, CHS is prevalent in 22% of patients and is associated with increased postinterventional mortality. Thus, CHS should be included in the decision-making process within the TAVR heart team. Cardiohepatic syndrome (CHS) as defined by an elevation of at least two of three laboratory cholestasis parameters above the upper limit of normal was prevalent in 22% of patients undergoing TAVR for severe AS. The presence of CHS was associated with more severe heart failure symptoms and worse three-year survival.


Assuntos
Estenose da Valva Aórtica , Colestase , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
8.
Clin Pract ; 13(3): 616-620, 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37218807

RESUMO

We report the case of a 49-year-old male who suffered from a myocardial infarction with subsequent cardiac arrest. The emergency medical team began cardiopulmonary resuscitation, including defibrillation of ventricular fibrillation. Although a return of spontaneous circulation was achieved after approximately 30 min of continued efforts, the patient went back into cardiac arrest on the way to the hospital and resuscitation had to be resumed. On admission, the patient was severely acidotic with a pH of 6.67, lactatemia of 19 mmol/L, and pronounced hypercapnia (pCO2 127 mmHg). Despite the poor prognosis, all possible efforts including coronary intervention and therapeutic hypothermia were carried out and the patient made a quick recovery with discharge from the intensive care unit on day 5. Survival of extreme acidosis, such as in this case, is rare. This is the first report of survival with good neurologic outcome in a patient with myocardial infarction, cardiac arrest, and pH of under 6.7 on admission at the clinic.

9.
EuroIntervention ; 19(6): 526-536, 2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37042426

RESUMO

BACKGROUND: Concomitant moderate/severe mitral regurgitation (MR) is observed in 17-35% of patients undergoing transcatheter aortic valve implantation (TAVI) and contributes to a worse prognosis. Studies analysing outcomes in patients undergoing TAVI with different MR aetiologies, including atrial functional MR (aFMR), are lacking. AIMS: We aimed to analyse outcomes and changes in MR severity in patients with aFMR, ventricular functional (vFMR) and primary mitral regurgitation (PMR) following TAVI. METHODS: We analysed all consecutive patients with at least moderate MR undergoing TAVI between January 2013 and December 2020 at the Munich University Hospital. Characterisation of MR aetiology was performed by detailed individual echocardiographic assessment. Three-year mortality, changes in MR severity and New York Heart Association (NYHA) Functional Class at follow-up were assessed. RESULTS: Out of 3,474 patients undergoing TAVI, 631 patients showed MR ≥2+ (172 with aFMR, 296 with vFMR, 163 with PMR). Procedural characteristics and endpoints were comparable between groups. The rate of MR improvement was 80.2% in aFMR patients, which was significantly higher compared to both other groups (vFMR: 69.4%; p=0.03; PMR: 40.8%; p<0.001). The estimated 3-year survival rates did not differ between aetiologies (p=0.57). However, MR persistence at follow-up was associated with increased mortality (hazard ratio 1.49, 95% confidence interval: 1.04-2.11; p=0.027), mainly driven by the PMR subgroup of patients. NYHA Class improved significantly in all groups. In patients with baseline MR ≥3+, the PMR aetiology was associated with the lowest MR improvement, the lowest survival rates and least symptomatic improvement. CONCLUSIONS: TAVI reduces MR severity and symptoms in patients with aFMR, vFMR and less-pronounced PMR. The presence of aFMR was associated with the greatest MR severity improvement.


Assuntos
Estenose da Valva Aórtica , Insuficiência da Valva Mitral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Resultado do Tratamento , Prognóstico , Ecocardiografia , Estenose da Valva Aórtica/diagnóstico , Índice de Gravidade de Doença , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
10.
Int J Cardiol ; 376: 100-107, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36758861

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a well-established, safe and effective therapy for severe symptomatic aortic stenosis (AS). The aim of this study was to objectively quantify improvement of physical activity after TAVR, with consideration of different low-gradient AS subtypes. METHODS AND RESULTS: All patients undergoing TAVR for severe AS were screened. Participants received a wearable activity tracker (Fitbit®) at hospital discharge following TAVR and 6 months thereafter. The difference of median daily steps was defined as surrogate outcome for physical activity. For analysis, patients were grouped into high-gradient (HG) AS (dPmean ≥40 mmHg), classical low-flow low-gradient (LFLG) AS (dPmean <40 mmHg, EF <50%), paradoxical LFLG-AS (dPmean <40 mmHg, EF ≥50%, SVi ≤35 ml/m2) and normal-flow low-gradient (NFLG) AS (dPmean <40 mmHg, EF ≥50%, SVi >35 ml/m2) according to mean transvalvular pressure gradient (dPmean), stroke volume index (SVi) and left-ventricular ejection fraction (LVEF). RESULTS AND CONCLUSIONS: The analysis is based on 230 patients. The median daily step count was 4409 [IQR 2581-7487] after hospital discharge and 5326 [IQR 3045-8668] 6 months thereafter. Median difference of daily steps was ∆529 [IQR -702-2152]). Patients with HG-AS and paradoxical LFLG-AS showed a significant improvement of daily steps (∆951 [IQR -378-2323], p <0.001 and (∆1392 [IQR -609-4444], p = 0.02, respectively). Patients with classical LFLG-AS showed no statistically relevant improvement of daily steps (∆192 [IQR -687-770], p = 0.79). Patients with NFLG-AS showed a numerical decline in daily steps without statistical significance (∆-300 [IQR -1334-1406], p = 0.67). This first prospective study of this sample size shows significant improvement of physical activity after TAVR with an objective and reproducible method. This was mainly driven by an improvement in patients with HG-AS and paradoxical LFLG-AS.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estudos Prospectivos , Volume Sistólico , Função Ventricular Esquerda , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Exercício Físico , Resultado do Tratamento , Índice de Gravidade de Doença
11.
Clin Res Cardiol ; 112(5): 645-655, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36637479

RESUMO

AIM: The aim of this study was to analyse the predictive value of CTA-determined tricuspid annular dilatation (TAD) on the persistence of tricuspid regurgitation (TR) in patients undergoing transcatheter aortic valve replacement (TAVR) for severe aortic stenosis (AS) and concomitant at least moderate TR. METHODS AND RESULTS: 288 consecutive patients treated with TAVR due to severe AS and concomitant at least moderate TR at baseline were included in the analysis. As cutoff for TAD, the median value of the CTA-determined, to the body surface area-normalized tricuspid annulus diameter (25.2 mm/m2) was used. TAD had no impact on procedural characteristics or outcomes, including procedural death and technical or device failure according to the Valve Academic Research Consortium 3 criteria. However, the primary outcome of the study-TR persistence after TAVR was significantly more frequent in patients with compared to patients without TAD (odds ratio 2.60, 95% confidence interval 1.33-5.16, p < 0.01). Multivariable logistic regression analysis, adjusting for clinical and echocardiographic baseline characteristics, which are known to influence aetiology or severity of TR, confirmed TAD as an independent predictor of TR persistence after TAVR (adjusted odds ratio 2.30, 95% confidence interval 1.20-4.46, p = 0.01). Moreover, 2 year all-cause mortality was significantly higher in patients with persistence or without change of TR compared to patients with TR improvement (log-rank p < 0.01). CONCLUSION: In patients undergoing TAVR for severe AS and concomitant at least moderate TR at baseline, TAD is a predictor of TR persistence, which is associated with increased 2-year all-cause mortality.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/etiologia , Dilatação/efeitos adversos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estudos Retrospectivos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Índice de Gravidade de Doença
12.
Int J Cardiol ; 371: 299-304, 2023 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-36306951

RESUMO

BACKGROUND: Normal-flow (stroke volume index, SVi >35 ml/m2) low-gradient (dPmean <40 mmHg) aortic stenosis (NFLG-AS) is subject of scientific debate. Guidelines fail to give conclusive treatment recommendations. We hypothesized that NFLG patients are heterogenous, containing a subgroup similar to high-gradient aortic stenosis patients (dPmean ≥40 mmHg, HG-AS) concerning characteristics and outcomes. METHODS: 2326 patients undergoing transcatheter aortic valve replacement (TAVI) at our centre between 2013 and 2019 were analysed. 386 patients fulfilled criteria of NFLG-AS. Their median dPmean was 33 mmHg, which was used for grouping (204 patients with higher gradient NFLG-AS, 186 patients with lower gradient NFLG-AS). They were compared to 956 HG-AS patients. RESULTS: Characteristics of lower gradient NFLG-AS patients differed from HG-AS patients in many aspects while higher gradient NFLG-AS and HG-AS patients were mostly similar, underscored by higher Society of Thoracic Surgeons scores in lower gradient NFLG-AS (lower gradient NFLG-AS, 3.9, HG-AS, 3.0, p = 0.03, higher gradient NFLG-AS, 3.0, p = 0.04). Procedural complications were comparable. Estimated 3-year all-cause mortality was higher in lower gradient NFLG-AS compared to HG-AS patients (hazard ratio 1.7, p < 0.01), whereas mortality of higher gradient NFLG-AS was similar to HG-AS patients (hazard ratio 1.2, p = 0.31). Cardiovascular mortality was highest among lower gradient NFLG-AS patients (21.6% vs. higher gradient NFLG-AS, 15.4%, vs. HG-AS, 11.1%, p < 0.01). CONCLUSIONS: NFLG-AS patients are indeed heterogenous. NFLG-AS patients with higher gradients resemble HG-AS patients in clinical characteristics and outcomes and should not be treated differently. Lower gradient NFLG-AS patients have increased long-term mortality and the use of TAVI requires careful consideration.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Função Ventricular Esquerda , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico , Índice de Gravidade de Doença
13.
Eur Heart J Acute Cardiovasc Care ; 11(12): 877-886, 2022 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-36210517

RESUMO

AIMS: Severe aortic stenosis can cause acute heart failure and cardiogenic shock (CS). Transcatheter aortic valve implantation (TAVI) is the standard therapy for aortic stenosis in inoperable patients. However, its role in this setting is poorly evaluated. The study purpose was to explore clinical characteristics of these patients and to assess predictors of mortality. METHODS AND RESULTS: All 2930 patients undergoing transfemoral TAVI at our centre between 2013 and 2019 were screened for critically ill patients, receiving intensive care therapy and emergency TAVI. Selected patients were subdivided into two groups, according to the presence or absence of CS. Remaining patients undergoing elective TAVI served as a comparison. Primary outcome was 90-day mortality. Out of 179 critically ill patients, 47 fulfilled criteria of CS (shock group) and 132 did not despite a severe decompensation (no shock group). Shock patients were more often male and had higher Society of Thoracic Surgeons scores [15.6, interquartile range (8.0-32.1) vs. 5.5 (3.9-8.5), P < 0.01] compared with severely decompensated patients. Ninety-day mortality was: shock group, 42.6%, vs. no shock group, 15.9%, vs. elective group, 5.3% (P < 0.01). A landmark analysis from day 90 showed similar mortality (P = 0.29). Compared with elective patients, 30-day composite endpoint device failure was higher in critically ill groups [shock group, odds ratio, 2.86 (1.43-5.36), no shock group, odds ratio, 1.74 (1.09-2.69)]. Multivariable regression revealed mechanical ventilation, haemofiltration, elevated C-reactive protein or bilirubin, and hypotension before TAVI as 90-day mortality predictors. CONCLUSION: Ninety-day mortality after TAVI in critically ill patients is increased but survivors have similar outcomes as elective patients.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Estado Terminal , Fatores de Risco , Resultado do Tratamento , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia
14.
EuroIntervention ; 18(10): 812-819, 2022 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-35903846

RESUMO

BACKGROUND: Large-bore arteriotomy for transcatheter aortic valve implantation (TAVI) requires percutaneous vascular closure devices, but real-world data comparing different closure strategies are limited. AIMS: We sought to compare a dual ProGlide strategy vs a combination of one ProGlide and one FemoSeal for vascular closure after TAVI. METHODS: We retrospectively analysed 874 propensity score-matched patients undergoing TAVI at the Munich University Hospital from August 2018 to October 2020. From August 2018 to August 2019, a dual ProGlide strategy was used for vascular closure. From October 2019 to October 2020, a combination of one ProGlide and one FemoSeal was used. The primary endpoint was defined as access-related major vascular complications or bleeding ≥Type 2 according to Valve Academic Research Consortium 3 criteria. RESULTS: Patients in the dual ProGlide group (n=437) had a higher incidence of the primary endpoint than patients treated with one ProGlide and one FemoSeal (n=437; 11.4% vs 3.0%; p<0.001). Furthermore, they had a higher rate of closure device failure (2.7% vs 0.9%; p=0.044) and more often required unplanned surgery or endovascular treatment (3.9% vs 0.9%; p=0.004). The incidence of death did not differ significantly between groups (3.4% vs 1.6%; p=0.08). CONCLUSIONS: A combined ProGlide and FemoSeal strategy might have the potential to reduce access-related vascular complications following TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Artéria Femoral/cirurgia , Resultado do Tratamento , Dispositivos de Oclusão Vascular/efeitos adversos , Hemostasia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Técnicas Hemostáticas/efeitos adversos
16.
J Cardiovasc Comput Tomogr ; 16(5): 423-430, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35637128

RESUMO

BACKGROUND: Computed tomography (CT) imaging is the standard of care before transcatheter aortic valve replacement (TAVR). The aortic annulus undergoes conformational changes during the heart cycle. Therefore, the image acquisition time point can impact prosthesis sizing and fit. Clinical outcome data are lacking. The aim of this study was to compare systolic and diastolic cardiac CT data acquisition with regard to procedural and clinical outcomes in patients undergoing TAVR for severe aortic stenosis (AS). METHODS: Preprocedural high-pitch helical CT datasets were analyzed in 1954 patients undergoing TAVR between 2013 and 2018 â€‹at our center. Patients were stratified into two groups according to the acquisition heart phase (979 systolic and 975 diastolic). The study was approved by the local ethics committee. RESULTS: Median age was 81.6 [interquartile range 77.5-85.8] years and 964 (49.3%) patients were male. No significant difference was found for the Valve Academic Research Consortium-3 (VARC-3) endpoints of technical failure (systolic, 5.1% vs. diastolic, 5.2%, p â€‹= â€‹0.94) or device failure (systolic, 13.7% vs. diastolic, 13.5%, p â€‹= â€‹0.92). There was no difference in paravalvular regurgitation. All-cause 30-day mortality was comparable (systolic, 3.6% [95% confidence interval, 2.4-4.7%] vs. diastolic, 3.6% [2.4-4.8%], p â€‹= â€‹1.00), while 3-year mortality rates were higher in the diastolic group (Society of Thoracic Surgeons score adjusted hazard ratio, 1.25 [1.07-1.46], p â€‹< â€‹0.01). CONCLUSIONS: While the 30-day technical and clinical outcomes after TAVR are comparable between systolic and diastolic CT imaging, diastolic imaging was associated with higher long-term mortality. Therefore, the data support the guideline recommendation of systolic imaging.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Sopros Cardíacos/etiologia , Humanos , Masculino , Valor Preditivo dos Testes , Fatores de Risco , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
17.
J Clin Med ; 11(6)2022 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-35329887

RESUMO

Despite the rapid increase in experience and technological improvement, the incidence of conduction disturbances in patients undergoing transcatheter aortic valve replacement (TAVR) with the self-expandable CoreValve Evolut valve remains high. Recently, a cusp-overlap view (COP) implantation technique has been proposed for TAVR with self-expandable valves offering an improved visualization during valve expansion compared to the three-cusp view (TCV). This study aims to systematically analyze procedural outcomes of TAVR patients treated with the CoreValve Evolut valve using a COP compared to TCV in a high-volume center. The primary endpoint was technical success according the 2021 VARC-3 criteria. A total of 122 consecutive patients (61 pts. TCV: April 2019 to November 2020; 61 pts. COP: December 2020 to October 2021) that underwent TAVR with the CoreValve Evolut prosthesis were included in this analysis. Although there was no difference in the primary endpoint technical success between TCV and COP patients (93.4% vs. 90.2%, OR 0.65, 95% CI 0.16, 2.4, p = 0.51), we observed a significantly lower risk for permanent pacemaker implantation (PPI) among COP patients (TCV: 27.9% vs. COP: 13.1%, OR 0.39, 95% CI 0.15, 0.97, p = 0.047). Implantation of the CoreValve Evolut prosthesis using the COP might help to reduce the rate of PPI following TAVR.

18.
Clin Res Cardiol ; 111(12): 1325-1335, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35320407

RESUMO

OBJECTIVES: The study objective was to characterize different groups of low-flow low-gradient (LFLG) aortic stenosis (AS) and determine short-term outcomes and long-term mortality according to Valve Academic Research Consortium-3 (VARC-3) endpoint definitions. BACKGROUND: Characteristics and outcomes of patients with LFLG AS undergoing transcatheter aortic valve implantation (TAVI) are poorly understood. METHODS: All patients undergoing TAVI at our center between 2013 and 2019 were screened. Patients were divided into three groups according to mean pressure gradient (dPmean), ejection fraction (LVEF), and stroke volume index (SVi): high gradient (HG) AS (dPmean ≥ 40 mmHg), classical LFLG (cLFLG) AS (dPmean < 40 mmHg, LVEF < 50%), and paradoxical LFLG (pLFLG) AS (dPmean < 40 mmHg, LVEF ≥ 50%, SVi ≤ 35 ml/m2). RESULTS: We included 1776 patients (956 HG, 447 cLFLG, and 373 pLFLG patients). Most baseline characteristics differed significantly. Median Society of Thoracic Surgeons (STS) score was highest in cLFLG, followed by pLFLG and HG patients (5.0, 3.9 and 3.0, respectively, p < 0.01). Compared to HG patients, odds ratios for the short-term VARC-3 composite endpoints, technical failure (cLFLG, 0.76 [95% confidence interval, 0.40-1.36], pLFLG, 1.37 [0.79-2.31]) and device failure (cLFLG, 1.06 [0.74-1.49], pLFLG, 0.97 [0.66-1.41]) were similar, without relevant differences within LFLG patients. NYHA classes improved equally in all groups. Compared to HG, LFLG patients had a higher 3-year all-cause mortality (STS score-adjusted hazard ratios, cLFLG 2.16 [1.77-2.64], pLFLG 1.53 [1.22-193]), as well as cardiovascular mortality (cLFLG, 2.88 [2.15-3.84], pLFLG, 2.08 [1.50-2.87]). CONCLUSIONS: While 3-year mortality remains high after TAVI in LFLG compared to HG patients, symptoms improve in all subsets after TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Índice de Gravidade de Doença , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
19.
J Sports Med Phys Fitness ; 62(5): 595-601, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-33871243

RESUMO

BACKGROUND: COVID-19 pandemic has affected worldwide sports competitions and training in both amateur and professional leagues. We thus aimed to investigate changes in different training modalities in elite and amateur football players following COVID-19 lockdown in March 2020. METHODS: In this cross-sectional study, we applied a Likert Scale-based questionnaire with 20 items to quantify and classify time spent at standard training methods in 47 professional and 54 amateur football players from 12 Austrian clubs before and during lockdown. Additionally, McLean Score was calculated to assess perceived training fatigue. RESULTS: Weekly amount of training time at endurance exercises (cycling) increased in both professional (37.5 [IQR 46.5] min/week vs. 187.5 [IQR 127.5] min/week, P<0.001), and amateur players (0.0 [IQR 45.0] min/week vs. 37.5 [IQR 112.5] min/week, P=0.015) during COVID-19 lockdown. Time on diverse muscle strengthening workouts was significantly elevated in both cohorts. Total training time at ball declined for professionals (from 472.5 [IQR 150] min/week to 15.0 [IQR 112.5] min/week, P<0.001) and amateurs (from 337.5 [IQR 285] min/week to 0.0 [IQR 37.5] min/week, P<0.001). Video-guided training was intensified in both groups (P<0.001 each). Location shifted from football fields and gyms to home and outdoors. Overall McLean Score remained unchanged in amateurs (P=0.42) while elite players showed a trend towards an increase (P=0.056). CONCLUSIONS: COVID-19 lockdown compromised football training, especially training concepts with ball. Consequently, resulting changes in exercise loads and muscular burden might impact susceptibility for injuries and impair performances especially in amateur players, especially as they lacked training supervision and professional training plans. Minimum effective dose of training workload to maintain endurance- and neuromuscular-related performance parameters should be prescribed.


Assuntos
COVID-19 , Futebol Americano , COVID-19/epidemiologia , Controle de Doenças Transmissíveis , Estudos Transversais , Futebol Americano/fisiologia , Humanos , Pandemias
20.
Clin Res Cardiol ; 111(8): 869-880, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34786592

RESUMO

BACKGROUND: The impact of postero-anterior and medio-lateral mitral valve (MV) tethering patterns on outcomes in patients undergoing transcatheter edge-to-edge repair (M-TEER) for secondary mitral regurgitation (SMR) is unknown. METHODS: The ratio of the posterior to anterior MV leaflet angle (PLA/ALA) in MV segment 2 was defined as postero-anterior tethering asymmetry. Medio-lateral tethering asymmetry was assessed as the ratio of the medial (segment 3) to lateral (segment 1) MV tenting area. We used receiver-operating characteristics and a Cox regression model to identify cut-off values of asymmetric anteroposterior and medio-lateral tethering for prediction of 2 year all-cause mortality after TMVR. RESULTS: Among 178 SMR patients, postero-anterior tethering was asymmetric in 67 patients (37.9%, PLA/ALA ratio > 1.54). Asymmetric medio-lateral tethering (tenting area ratio > 1.49) was observed in 49 patients (27.5%). M-TEER reduced MR to ≤ 2 + in 92.1% of patients; MR reduction was less effective in the presence of asymmetric postero-anterior tethering (p = 0.02). A multivariable Cox regression model identified both types of asymmetric MV tethering to be associated with increased all-cause 2-year mortality (postero-anterior tethering asymmetry: HR = 2.77, CI 1.43-5.38; medio-lateral tethering asymmetry: HR = 2.90, CI 1.54-5.45; p < 0.01). CONCLUSIONS: Asymmetric postero-anterior and medio-lateral MV tethering patterns are associated with increased 2-year mortality in patients undergoing M-TEER for SMR. A detailed echocardiographic analysis of MV anatomy may help to identify patients who profit most from M-TEER.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Poliésteres , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...