Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Appl Opt ; 53(31): 7267-72, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-25402886

RESUMO

Current Fourier transform infrared spectroscopy (FTIR) systems have very good spectral resolution, but are bulky, sensitive to vibrations, and slow. We developed a new FTIR system using a microelectromechanical system (MEMS)-based lamellar grating interferometer that is fast, compact, and achromatic (i.e., does not require a beam splitter). The MEMS device has >10 mm2 active surface area, up to ±325 µm mechanical displacement, and a 343 Hz resonant operation frequency. The system uses a 5 MHz bandwidth custom infrared (IR) detector and a small emission area custom blackbody source to achieve fast interferogram acquisition and compact form factor. Effects of lamellar grating period, detector size, laser reference, apodization, and averaging of data on the spectral resolution are discussed. The measurement time ranges from 1.5 to 100 ms depending on the averaging time. In the target range of 2.5-16 µm (625-4000 cm-1) a spectral resolution of 15-20 cm-1 is demonstrated. The measurements are shown to be stable over a long time.

2.
Opt Lett ; 38(8): 1224-6, 2013 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-23595438

RESUMO

We demonstrate a method to increase the sensitivity of the s-p phase shift under total internal reflection (TIR) for optical sensing. This is achieved by the introduction of two simple dielectric layers to the TIR surface of a fused silica prism. The enhanced sensitivity is demonstrated using evanescent-wave cavity-ring-down-ellipsometry by measuring the refractive index of liquid mixtures and by studying the adsorption of polymers to the TIR surface of the fused silica prism.

3.
Opt Express ; 17(20): 18219-28, 2009 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-19907613

RESUMO

Ellipsometry gives access to the phenomenological parameters of a grating coupled slab waveguide structure and permits its functional modeling without a priori knowledge of the geometry of the structure. The evidence is shown by comparing with the exact electromagnetic modeling of a sliced cross-section of a singlemode grating waveguide biosensor chip cut by FIB and analyzed by SEM.


Assuntos
Algoritmos , Análise de Falha de Equipamento/métodos , Refratometria/instrumentação , Refratometria/métodos , Luz , Espalhamento de Radiação
4.
Appl Opt ; 47(36): 6680-91, 2008 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-19104520

RESUMO

The photorefractivity of an indole derivative and of its polymer blends has been studied at room temperature. The indole derivative 3-[2-(4-nitrophenyl)ethenyl]-1-(2-ethylhexyl)-2-methylindole (NPEMI-E) is a typical low-molecular-weight glass-forming molecule having peculiar nonlinear optics characteristics. It is unconditionally soluble in the photoconductive poly-(N-vinyl-2,3-dimethylindole) so that all the possible blends can be studied for a weight percent (wt. %) content of NPEMI-E ranging from zero to 100. A very high and sharp maximum of the photorefractive optical gain Gamma(2) approximately 2000 cm(-1) was obtained for a NPEMI-E wt. % content of about 90. On the basis of recently published theoretical calculations, we have made the hypothesis that the rapid change of Gamma(2) can also be ascribed to a correspondingly quick variation of the molecular electro-optic parameters of the dissolved chromophore for some well distinguished values of its concentration in the polymer matrix. Differential scanning calorimetry measurements were made and the results carefully analyzed with the aim of obtaining information on the intermolecular interactions. These last measurements also allowed rationalizing the unconditionally stable glass appearance of the obtained blends. Measurements of spectroscopic ellipsometry were also made on blends with different NPEMI-E content.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA