Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Exp Med Biol ; 876: 41-47, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26782193

RESUMO

We used spatially resolved near-infrared spectroscopy (SRS-NIRS) to assess calf and thigh muscle oxygenation during running on a motor-driven treadmill. Two protocols were used: An incremental speed protocol was performed in 5-min stages, while a pacing paradigm modulated the step frequency (2.3 Hz [SLow]; 3.3 Hz [SHigh]) during a constant velocity for 2 min each. A SRS-NIRS broadband system was used to measure total haemoglobin concentration and oxygen saturation (SO2). An accelerometer was placed on the hip joints to measure limb acceleration through the experiment. The data showed that the calf desaturated to a significantly lower level than the thigh. During the pacing protocol, SO2 was significantly different between the high and low step frequencies. Additionally, physiological data as measured by spirometry were different between the SLow vs. SHigh pacing trials. Significant differences in VO2 at the same workload (speed) indicate alterations in mechanical efficiency. These data suggest that SRS broadband NIRS can be used to discern small changes in muscle oxygenation, making this device useful for metabolic exercise studies in addition to spirometry and movement monitoring by accelerometers.


Assuntos
Músculo Esquelético/metabolismo , Oxigênio/metabolismo , Corrida/fisiologia , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Adulto , Feminino , Humanos , Masculino , Consumo de Oxigênio
2.
Adv Exp Med Biol ; 876: 419-425, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26782241

RESUMO

We demonstrate an efficient algorithm for the temporal and spatial based calculation of speckle contrast for the imaging of blood flow by laser speckle contrast analysis (LASCA). It reduces the numerical complexity of necessary calculations, facilitates a multi-core and many-core implementation of the speckle analysis and enables an independence of temporal or spatial resolution and SNR. The new algorithm was evaluated for both spatial and temporal based analysis of speckle patterns with different image sizes and amounts of recruited pixels as sequential, multi-core and many-core code.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Humanos
3.
Neuroimage ; 94: 250-262, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24657778

RESUMO

Brain function critically relies on the supply with energy substrates (oxygen and glucose) via blood flow. Alterations in energy demand as during neuronal activation induce dynamic changes in substrate fluxes and blood flow. To study the complex system that regulates cerebral metabolism requires the combination of methods for the simultaneous assessment of multiple parameters. We developed a multimodal imaging device to combine positron emission tomography (PET) with laser speckle imaging (LSI) and RGB reflectometry (RGBR). Depending on the radiotracer, PET provides 3-dimensional quantitative information of specific molecular processes, while LSI and RGBR measure cerebral blood flow (CBF) and hemoglobin oxygenation at high temporal and spatial resolution. We first tested the functional capability of each modality within our system and showed that interference between the modalities is negligible. We then cross-calibrated the system by simultaneously measuring absolute CBF using (15)O-H2O PET (CBF(PET)) and the inverse correlation time (ICT), the LSI surrogate for CBF. ICT and CBF(PET) correlated in multiple measurements in individuals as well as across different animals (R(2)=0.87, n=44 measurements) indicating that ICT can be used for absolute quantitative assessment of CBF. To demonstrate the potential of the combined system, we applied it to cortical spreading depression (CSD), a wave of transient cellular depolarization that served here as a model system for neurovascular and neurometabolic coupling. We analyzed time courses of hemoglobin oxygenation and CBF alterations coupled to CSD, and simultaneously measured regional uptake of (18)F-2-fluoro-2-deoxy-D-glucose ((18)F-FDG) used as a radiotracer for regional glucose metabolism, in response to a single CSD and to a cluster of CSD waves. With this unique combination, we characterized the changes in cerebral metabolic rate of oxygen (CMRO2) in real-time and showed a correlation between (18)F-FDG uptake and the number of CSD waves that passed the local tissue. Finally, we examined CSD spontaneously occurring during focal ischemia also referred to as peri-infarct depolarization (PID). In the vicinity of the ischemic territory, we observed PIDs that were characterized by reduced CMRO2 and increased oxygen extraction fraction (OEF), indicating a limitation of oxygen supply. Simultaneously measured PET showed an increased (18)F-FDG uptake in these regions. Our combined system proved to be a novel tool for the simultaneous study of dynamic spatiotemporal alterations of cortical blood flow, oxygen metabolism and glucose consumption under normal and pathologic conditions.


Assuntos
Mapeamento Encefálico/instrumentação , Encéfalo/metabolismo , Glucose/metabolismo , Microscopia Confocal/instrumentação , Oxigênio/metabolismo , Fotometria/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Animais , Isquemia Encefálica/metabolismo , Circulação Cerebrovascular , Colorimetria/instrumentação , Depressão Alastrante da Atividade Elétrica Cortical/fisiologia , Desenho de Equipamento , Análise de Falha de Equipamento , Ratos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual , Imagens com Corantes Sensíveis à Voltagem/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...