Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
PLoS One ; 9(6): e99302, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24979700

RESUMO

Antiphospholipid antibodies (aPLs) frequently occur in autoimmune and cardiovascular diseases and correlate with a worse clinical outcome. In the present study, we evaluated the association between antiphospholipid antibodies (aPLs), markers of inflammation, disease progression and the presence of an intra-aneurysmal thrombus in abdominal aortic aneurysm (AAA) patients. APLs ELISAs were performed in frozen serum samples of 96 consecutive AAA patients and 48 healthy controls yielding positive test results in 13 patients (13.5%) and 3 controls (6.3%; n.s.). Nine of the 13 aPL-positive AAA patients underwent a second antibody testing >12 weeks apart revealing a positive result in 6 cases. APL-positive patients had increased levels of inflammatory markers compared to aPL-negative patients. Disease progression was defined as an increase of the AAA diameter >0.5 cm/year measured by sonography. Follow-up was performed in 69 patients identifying 41 (59.4%) patients with progressive disease. Performing multipredictor logistic regression analysis adjusting for classical AAA risk factors as confounders, the presence of aPLs at baseline revealed an odds ratio of 9.4 (95% CI 1.0-86.8, p = 0.049) to predict AAA progression. Fifty-five patients underwent a computed tomography in addition to ultrasound assessment indicating intra-aneurysmal thrombus formation in 82.3%. Median thrombus volume was 46.7 cm3 (1.9-377.5). AAA diameter correlated with the size of the intra-aneurysmal thrombus (corrcoeff = 0.721, p<0.001), however neither the presence nor the size of the intra-aneurysmal thrombus were related to the presence of aPLs. In conclusion, the presence of aPLs is associated with elevated levels of inflammatory markers and is an independent predictor of progressive disease in AAA patients.


Assuntos
Anticorpos Antifosfolipídeos/sangue , Aneurisma da Aorta Abdominal/sangue , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Biomarcadores/sangue , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ultrassonografia
2.
Eur J Radiol ; 82(11): 1989-95, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23910043

RESUMO

BACKGROUND: The differentiation between stable and vulnerable plaques in the internal carotid artery (ICA) remains a matter of interest. With the implementation of contrast agent in magnetic resonance imaging (MRI) a more detailed plaque characterization is possible. The study at hand focuses on enhancement patterns of fibro cellular tissue in different kinds of plaques in the ICA. METHODS: Between May 2011 and December 2012, 49 patients (39 male) with >50% stenosis of the ICA were consecutively enrolled. In 10 patients with bilateral ICA stenosis, both plaques were included for analysis. We performed a classification of plaques according to Cai and observed 11 type 4-5 plaques, 15 type 6 plaques and 33 type 8 plaques. MRI was performed on a 3T whole body MR system. The standard 12 channel head coil was combined with the neck extension coil and two bilateral 7 cm loop coils. Post-contrast T1w images were subtracted from pre contrast images to identify late enhancement in fibro cellular tissue. Enhancement patterns were allocated as intraluminal, intraplaque and vasa vasorum enhancement in different types of plaques. RESULTS: Fibro cellular tissue always exhibited a higher contrast enhancement compared to the sternocleidomastoid muscle. This reflects a higher grade of vascularization of the fibrocellular tissue. Contrast enhancement was present irrespective of the plaque type. In detail, intraluminal, intraplaque and vasa vasorum enhancement were observed in all types of plaques. Even type 8 plaques, according to the classification of Cai, had a significant contrast enhancement, though supposed to be with low inflammatory activity. CONCLUSION: Type 8 plaques might not be as stable as postulated. Whether the relevant uptake of contrast agent is due to the fibrous tissue or reflects the inflammatory activity of the plaque should be matter of further investigations.


Assuntos
Algoritmos , Artéria Carótida Interna/patologia , Estenose das Carótidas/patologia , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Idoso , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Arch Orthop Trauma Surg ; 133(10): 1367-73, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23892556

RESUMO

OBJECTIVES: During the last decade, many educational efforts and technological improvements have been made to protect skiing athletes from injuries. Whether these efforts have changed the pattern of acute injuries from skiing casualties has not yet been shown on a medical basis, which this longitudinal study examines. METHODS: All patients transferred to the Department of Radiology of our level I trauma center for acute emergency computed tomography (CT) after alpine skiing accidents from 2000 to 2011 were included. We hypothesized that only patients with clinical suspicion for injuries were admitted for acute CT. RESULTS: Of all acute patients after skiing accidents, 2,252 could be included. From 2000 to 2011, all cerebral injuries and vascular arterial injuries statistically significantly decreased (p < 0.05, respectively). However, extremity fractures, facial fractures, and vertebral fractures increased (p < 0.04, respectively). The number of cerebral hemorrhages, thoracic injuries, and abdominal injuries remained unchanged (p = NS). The mean (SD) number of all initial radiological examinations per victim statistically significantly decreased from 2.3 (0.7) in 2000 to 1.5 (0.6) in 2011, whereas the admissions for acute CT have significantly increased (p < 0.02; respectively). CONCLUSIONS: Acute radiological evaluation in skiing accidents has changed during the last decade. The decrease in overall cerebral injuries might be a function of the increasing use of skiing helmets. A protection of the extremities, trunk, spine, and face, however, needs further improvements and their radiological assessment with CT warrants attention in skiing casualties.


Assuntos
Esqui/lesões , Ferimentos e Lesões/epidemiologia , Adulto , Áustria/epidemiologia , Feminino , Humanos , Modelos Lineares , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Estudos Retrospectivos , Centros de Traumatologia , Ferimentos e Lesões/diagnóstico , Ferimentos e Lesões/diagnóstico por imagem , Ferimentos e Lesões/etiologia
4.
J Endovasc Ther ; 17(4): 492-503, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20681765

RESUMO

PURPOSE: To retrospectively evaluate a 12-year experience with endovascular repair of isolated iliac artery aneurysm (IAA). METHODS: From August 1997 through July 2009, 91 patients (81 men; mean age 71 years, range 31-90) underwent endovascular treatment for isolated IAA at our department. Of these, 77 patients received stent-grafts either alone or in combination with coils or an Amplatzer vascular plug (n = 2); 1 patient received a Smart stent combined with coils, and 13 patients were treated with coil embolization only. The aneurysms were classified according to location: type I = common iliac artery (CIA), type II = internal iliac artery (IIA), type III = CIA and IIA, and type IV = external iliac artery with/without CIA and/or IIA involvement. RESULTS: Primary technical success was 90.1% for all aneurysm types and 93.6%, 80%, 88.8%, and 93.3% for types I, II, III, and IV, respectively. Secondary technical success was 96.7% for all types and 97.8%, 95%, 100%, and 93.3%, respectively, for each type. Clinical success was 93.4% for all types and 97.8%, 85%, 100%, and 86.7%, respectively, by type. Complications in 18 (19.8%) patients included 7 type I endoleaks, 3 type II endoleaks, 2 enlarged aneurysm sacs (incomplete embolization), 5 cases of buttock claudication, and 2 stent-graft thromboses. Two patients were converted to open surgery; 10 underwent secondary interventions. Mortality rates were 1.1% (n = 1) at 30 death days and 23.1% (n = 21) over a mean follow-up of 45.9 months (no aneurysm-related death). Cumulative overall survival was 97.7% at 1 year and 47.6% at 10 years. Freedom from aneurysm-related complications was 88.6% at 1 year and 83.5% at 5 years. CONCLUSION: Endovascular repair of isolated IAA is a safe and minimally invasive alternative to surgery. However, it may be associated with several complications and must, therefore, be carefully planned.


Assuntos
Implante de Prótese Vascular , Embolização Terapêutica , Aneurisma Ilíaco/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Áustria , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/instrumentação , Embolização Terapêutica/mortalidade , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/mortalidade , Aneurisma Ilíaco/cirurgia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Estudos Retrospectivos , Medição de Risco , Stents , Taxa de Sobrevida , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
5.
J Vasc Surg ; 49(6): 1505-13, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19497514

RESUMO

OBJECTIVE: The purpose of this retrospective study was to evaluate transcatheter arterial embolization (TAE) for the management of iatrogenic and blunt traumatic intercostal artery (ICA) injuries associated with hemothorax and clinical deterioration. METHODS: From May 1999 through April 2007, 24 consecutive patients (17 men, 7 women; mean age 53 years) presenting with active ICA hemorrhage underwent TAE mainly by means of coils combined with polyvinyl alcohol (PVA) particles. Eleven of them had blunt traumatic injuries (group A, n = 11) and 13 had iatrogenic injuries (group B, n = 13). In all patients, ICA injuries resulted in acute bleeding with clinical deterioration and hemothorax. Before discharge, all patients underwent clinical examination, laboratory tests, and chest x-ray. After discharge, no specific follow-up protocol was required, and the patients were questioned on their state of health at regular intervals and underwent CT or chest x-ray as needed. RESULTS: Primary technical success (PTS) was achieved in 21 of 24 patients (87.5%). In group A, it was achieved in all but one patient (90.9%) and in group B in 11 of 13 patients (84.6%). A total of three patients needed secondary interventions, which failed in one of them, amounting to a secondary technical success rate (STS) of 8.3%. The total cumulative mortality rate was 37.5% (n = 9). In group A, it was 9.1% (n = 1) and in group B, it was 61.5% (n = 8). 30-day-mortality was 9.1% in group A, where one patient died due to multiple severe associated injuries, and 30.8% (n = 4) in group B, where one patient died due to treatment failure and three patients due to severe comorbidities. During follow-up, no more deaths occurred in group A, while in group B, four more patients died due to severe comorbidities, amounting to a late mortality rate of 30.8%. No technical complications and no complications such as chest wall or spinal cord ischemia were observed. The mean observation period was 44.6 months in group A and 23.8 months in group B. CONCLUSION: TAE of ICAs is a minimally invasive, safe, and reliable treatment option to control massive intrathoracic hemorrhage, especially in patients with serious comorbidities and/or multiple injuries. However, it should be performed only by experienced interventionalists and exact knowledge of the anatomic features of the affected artery and of collateral pathways is mandatory to avoid complications.


Assuntos
Embolização Terapêutica/métodos , Hemorragia/terapia , Hemotórax/terapia , Doença Iatrogênica , Álcool de Polivinil/uso terapêutico , Artérias Torácicas/lesões , Ferimentos não Penetrantes/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Embolização Terapêutica/efeitos adversos , Feminino , Hemorragia/diagnóstico por imagem , Hemorragia/etiologia , Hemorragia/mortalidade , Hemotórax/diagnóstico por imagem , Hemotórax/etiologia , Hemotórax/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Artérias Torácicas/diagnóstico por imagem , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ferimentos não Penetrantes/complicações , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/mortalidade , Adulto Jovem
6.
BJU Int ; 103(2): 224-35, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18710445

RESUMO

OBJECTIVE: To analyse the morphological appearance of horseshoe kidneys (HKs) and crossed fused ectopia (CFE) and to assess the frequency and clinical significance of associated anomalies and diseases. PATIENTS AND METHODS: The findings and images of 209 patients with fused kidneys (FKs) were reviewed; in all, 244 scans from computed tomography (CT), 233 ultrasonograms and 89 micturition cysto-urethrograms, urograms, magnetic resonance images and angiograms were taken. RESULTS: HKs (found in one of 474 abdominal CT scans) and CFEs (found in one of 3078 CT scans) showed a high variability of vasculature that could not be classified. However, some generalized conclusions were possible about the renal vasculature (430 arteries in 103 kidneys). Variants of the most cephalad artery of both sides were rare. The second artery on the right had a pre-caval course. The origins of vessels located further caudal were more ventral. CFEs were anatomically different from HKs with respect to lower position, greater axial rotation, smaller pelvic width, more caudal origin, and fewer vessels, but not in accompanying anomalies. Severe anomalies or malformations were found in 23% of patients, with half of them in the urogenital system. Malformations were found considerably more often in children than in adults. There was no increased incidence of diseases such as stones or inflammation of the renal pelvis. CONCLUSION: Concomitant anomalies and diseases were equally frequent for HK and CFE, but less frequent than generally assumed. Individual cases of complex anatomical situations require special examination strategies, and CT appears to be the most reliable imaging method.


Assuntos
Nefropatias/etiologia , Rim/anormalidades , Adulto , Criança , Feminino , Humanos , Rim/irrigação sanguínea , Nefropatias/diagnóstico , Imageamento por Ressonância Magnética , Masculino , Tomografia Computadorizada por Raios X
7.
J Vasc Surg ; 49(1): 20-8, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18986789

RESUMO

OBJECTIVE: The aim of this retrospective study was to evaluate aortic volume changes in patients with acute type B aortic dissection (TBD), treated either by thoracic endovascular aortic repair (TEVAR) or conservatively. MATERIALS AND METHODS: From July 1996 through March 2008, 76 patients presenting with acute TBD were referred to our department. To ensure a follow-up of at least 24 months, only 64 of them were included in the present study, with the cut-off for inclusion being March 2006. Twenty-nine of these patients underwent TEVAR and 35 patients underwent conservative treatment. Indications for TEVAR were life-threatening symptoms. Follow-up was performed postinterventionally in patients after TEVAR and at 3, 6, and 12 months, and yearly thereafter in both groups. It included clinical examinations, computed tomography (CT) scans, analysis of volume changes in true thoracic lumen (TTL), false thoracic lumen (FTL), thoracic lumen (TL), abdominal lumen (AL), and aortic diameter measurements. In addition, the extent of thrombosis and its influence on volume changes were assessed. RESULTS: Mean follow-up was 41 months after TEVAR and 46 months in the conservatively-treated patients. At 60 months, cumulative rates of freedom from dissection-related death and rupture-free survival were 82.6% and 93.1% in the TEVAR group, respectively. They were 74.9% and 88.5% in the conservatively-treated group, respectively. In the conservatively-treated patients, 3 patients died of late aortic rupture, 4 were converted to open surgery, and 2 to TEVAR. Evaluation of volume changes showed better results in the TEVAR group within 24 months. However, within 60 months the difference between the two groups was no longer relevant. Relating to thrombosis of the FTL, analyses showed slightly better overall results and promotion of thrombus formation after TEVAR. However, at 60 months the results showed a tendency towards approximation between the two groups. CONCLUSION: Our data suggest that TEVAR seems to delay the natural course of the disease but not to stop it.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/complicações , Dissecção Aórtica/mortalidade , Angiografia Digital , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/mortalidade , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/etiologia , Ruptura Aórtica/cirurgia , Aortografia/métodos , Dilatação Patológica , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/cirurgia , Fatores de Tempo , Tomografia Computadorizada Espiral , Resultado do Tratamento
8.
Eur Spine J ; 17(9): 1251-5, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18663485

RESUMO

The determination of skeletal age is essential in the management of patients with scoliosis. One of the most frequently used techniques to determine skeletal maturity is the method described by Risser. However, repeated X-ray exposure in the follow-up examinations of scoliosis patients may increase the risk of cancer. We compared conventional radiological evaluation of the Risser grade with ultrasound evaluation. For scoliosis patients routine application of ultrasound in the follow-up examinations may significantly reduce radiation exposure. 46 adolescent idiopathic scoliosis patients (median age, 14.5 years) were investigated. Sonographic and radiographic assessment of Risser sign was carried out by two independent senior staff skeletal radiologists. Agreement of Risser Grade between the two diagnostic methods was determined by Kappa statistics. Coefficients <0.21, 0.21-0.40, 0.41-0.60, 0.61-0.80, and >0.80 were rated as poor, fair, moderate, good, and very good agreement. For Risser Grades I-III 100% agreement was found between the two methods. Disagreement between radiographic and sonographic evaluation was found in Risser Grades IV and V. In five patients, X-ray evaluation yielded Risser Grade V while ultrasound showed Risser Grade IV. In one patient, radiographic examination resulted in Risser Grade IV while Grade V was detected in ultrasound. Overall, the Kappa value showed very good agreement between the two diagnostic methods. Our findings suggest that ultrasound can be applied as an alternative method to X-ray evaluation in Risser Grade determination. It should be routinely used in clinical practice to reduce the patients exposure to radiation.


Assuntos
Escoliose/diagnóstico por imagem , Índice de Gravidade de Doença , Adolescente , Criança , Feminino , Humanos , Masculino , Estudos Prospectivos , Radiografia/economia , Radiografia/métodos , Escoliose/diagnóstico , Ultrassonografia/economia , Ultrassonografia/métodos
9.
J Endovasc Ther ; 15(2): 150-60, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18426272

RESUMO

PURPOSE: To evaluate midterm results of endovascular stent-graft placement for acute Stanford type B dissection (TBD). METHODS: A retrospective review was conducted of 35 consecutive patients who were treated with stent-graft implantation for acute TBD between July 1996 and July 2007. Computed tomographic (CT) volumetric analysis of the true lumen (TL) and false lumen (FL) changes in 23 patients was performed, as well as evaluation of the influence of re-entry points and length of stent-graft coverage on volume changes. In addition, complications were evaluated. Follow-up was performed at 6 and 12 months and yearly thereafter. RESULTS: The technical success rate was 82.7%, and the 30-day mortality rate was 8.5%. Mean follow-up was 34 months. The overall survival rate at 5 years was 78.4%. Complications included retrograde type A dissections in 3 patients during the perioperative period and in 1 patient during midterm follow-up. In addition, 5 early and 3 late endoleaks were observed. Three patients were converted to open surgery and 2 needed secondary interventions. In the stented segment, stabilization of the aorta was achieved even during midterm follow-up, with a TL volume increase of 59% at 5 years and nearly stable FL volume. The segment from the distal end of the stent-graft to the celiac artery, however, showed unstable TL and FL volumes, with high standard deviations after the first postinterventional year and circumferential aneurysmal dilatation of the aorta immediately adjacent to the stent-graft in 5 patients. The abdominal aorta showed no substantial volume changes over time. The length of stent-graft coverage and the occurrence of re-entries greatly influenced FL volume changes distal to the stent-graft. CONCLUSION: Serious complications can occur during and after endovascular repair of TBD. Therefore, it should be reserved for high-risk patients.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Stents , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Retrospectivos , Estatísticas não Paramétricas , Taxa de Sobrevida , Tomografia Computadorizada por Raios X , Resultado do Tratamento
12.
J Endovasc Ther ; 11(1): 1-12, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14748634

RESUMO

PURPOSE: To evaluate the outcome of stent-graft placement in Stanford type B aortic dissection using contrast-enhanced spiral computed tomographic (CT) measurements of true and false lumen volumes and thrombus length. METHODS: Among 18 consecutive patients (13 men; mean age 60 years, range 44-79) who underwent endovascular repair of Stanford type B dissection, 12 completed at least a 12-month follow-up, which included CT measurements of true and false lumen volumes and thrombus lengths prior to discharge and at 6 and 12 months postimplantation. Volumes were assessed in 3 different aortic segments (A1, A2, A3) extending from the proximal attachment site of the prosthesis to the aortic bifurcation. In addition, thrombus length was measured to evaluate the influence of clot formation on outcome of the false lumen volume. RESULTS: Mean follow-up was 27 months (range 12-60). Within 12 months, mean true lumen volumes showed statistically significant increases in the A1 (p<0.001) and A2 (p=0.003) segments; false lumen volumes showed a significant decrease in the A1 segment (p=0.002) but an insignificant increase in the A2 segment. No substantial volume changes were observed in the A3 segment. Extension of clot formation in the false lumen varied among patients and over time. Length of stent-grafts, percentage of stented dissection length, or visceral arteries originating from the false lumen did not significantly influence thrombus development, nor did these parameters or thrombus formation distal to the prosthesis have a relationship to false lumen volumes. CONCLUSIONS: Volumetric analysis after endovascular repair of Stanford type B dissection shows optimal technical outcome in the stented segment, whereas the false lumen in the segment immediately adjacent to the stent-graft seems to be a vulnerable area. Extension of clot formation beyond the endograft seems to be no reliable predictor of outcome.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Implante de Prótese Vascular , Intensificação de Imagem Radiográfica , Adulto , Idoso , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Stents , Trombose/etiologia , Tomografia Computadorizada Espiral
13.
AJR Am J Roentgenol ; 181(1): 99-108, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12818838

RESUMO

OBJECTIVE: The aim of this study was to determine the accuracy of CT arterioportography and hepatic digital subtraction angiography, separately and combined, for the detection of hepatocellular carcinoma in the cirrhotic liver by using thin-section liver explant histopathologic findings. SUBJECTS AND METHODS: Fifty-nine patients with liver cirrhosis were examined with CT arterioportography and digital subtraction angiography as a part of preoperative diagnostic workup for liver transplantation. Before liver explantation, CT arterioportograms and digital subtraction angiograms were prospectively evaluated in a blinded manner, separately by two CT radiologists and two angiographers, respectively, and combined by two reviewer teams, each including a CT radiologist and an angiographer. In addition, each examination was retrospectively evaluated using direct comparison with the corresponding thin-section liver explant specimens RESULTS: There were 39 histologically confirmed hepatocellular carcinomas. In both prospective and retrospective assessments, the reviewers achieved the best performance with CT arterioportography and digital subtraction angiography combined (area under the curve [A(z)] 0.82). The diagnostic confidence in the detection of hepatocellular carcinoma was higher with digital subtraction angiography (A(z), 0.81) than that with CT arterioportography (A(z), 0.68). Prospectively, sensitivity and specificity were 75% and 60% for CT arterioportography, 77% and 80% for digital subtraction angiography, and 84% and 81% for CT arterioportography and digital subtraction angiography combined, respectively. Retrospectively, sensitivity and specificity were 80% and 62% for CT arterioportography; 82% and 79% for digital subtraction angiography; 87% and 81% for CT arterioportography and digital subtraction angiography combined, respectively. Five hepatocellular carcinomas, one poorly and four well differentiated, with a mean size of 1.4 cm were not detectable on the CT arterioportography and digital subtraction angiography combination. False-positive findings were 20, 11, and 10 on CT arterioportography, digital subtraction angiography, and the CT arterioportography and digital subtraction angiography combination. CONCLUSION: Combining CT arterioportography with digital subtraction angiography enabled reliable detectability of moderately and poorly differentiated hepatocellular carcinomas in cirrhotic livers but was less sensitive for the detection of well-differentiated hepatocellular carcinomas and resulted in a relatively high rate of false-positive findings.


Assuntos
Angiografia Digital , Carcinoma Hepatocelular/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Transplante de Fígado , Tomografia Computadorizada por Raios X , Carcinoma Hepatocelular/complicações , Carcinoma Hepatocelular/cirurgia , Reações Falso-Positivas , Feminino , Humanos , Fígado/patologia , Cirrose Hepática/complicações , Cirrose Hepática/cirurgia , Neoplasias Hepáticas/complicações , Neoplasias Hepáticas/cirurgia , Masculino , Pessoa de Meia-Idade , Portografia/métodos , Cuidados Pré-Operatórios , Estudos Prospectivos , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade
14.
Eur Radiol ; 13(2): 413-7, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12599009

RESUMO

With the introduction of digital flat-panel detector systems into clinical practice, the still unresolved question of resolution requirements for picture archiving communication system (PACS) workstation monitors has gained new momentum. This contrast detail analysis was thus performed to define the differences in observer performance in the detection of small low-contrast objects on clinical 1K and 2K monitor workstations. Images of the CDRAD 2.0 phantom were acquired at varying exposures on an indirect-type digital flat-panel detector. Three observers evaluated a total of 15 images each with respect to the threshold contrast for each detail size. The numbers of correctly identified objects were determined for all image subsets. No significant difference in the correct detection ratio was detected among the observers; however, the difference between the two types of workstations (1K vs 2K monitors) despite less than 3% was significant at a 95% confidence level. Slight but statistically significant differences exist in the detection of low-contrast nodular details visualized on 1K- and 2K-monitor workstations. Further work is needed to see if this result holds true also for comparison of clinical flat-panel detector images and may, for example, exert an influence on the diagnostic accuracy of chest X-ray readings.


Assuntos
Terminais de Computador , Apresentação de Dados , Aumento da Imagem/instrumentação , Sistemas de Informação em Radiologia/instrumentação , Humanos , Variações Dependentes do Observador , Imagens de Fantasmas , Sensibilidade e Especificidade
15.
AJR Am J Roentgenol ; 179(2): 337-45, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12130430

RESUMO

OBJECTIVE: The aim of this study was to evaluate the feasibility, safety, and effectiveness of endovascular stent-graft placement for the emergency treatment of acute descending thoracic aortic disease. MATERIALS AND METHODS: From January 1996 through November 2001, 18 patients underwent emergency endovascular stent-graft placement for various types of acute descending thoracic aortic disease. Five patients had Stanford type B aortic dissection, six had traumatic ruptures of the thoracic aorta, five had ruptured aortic aneurysms, and two had penetrating atherosclerotic aortic ulcers. All patients presented with life-threatening symptoms requiring treatment with stent-grafts from the emergency kit. All were at high surgical risk due to serious comorbidities. The efficacy of the procedure was assessed at follow-up studies before discharge and at 3, 6, and 12 months after intervention and yearly thereafter. RESULTS: The primary technical success rate was 78%. Four patients had primary perigraft leaks. The secondary technical success rate was 83%. One patient died 20 hr after intervention from stent-graft-related causes. Follow-up studies revealed stent-graft migration in one patient. Progression of disease was observed in one patient treated for dissection and in both patients treated for penetrating ulcers. One patient died 7 months after intervention of unknown reasons; all other patients are alive. The mean follow-up time was 17.4 months (range, 0-38 months). CONCLUSION: Emergency repair of acute descending thoracic aortic disease with stent-graft placement can be successfully accomplished and may be a promising alternative to open-chest surgery, especially in patients at high risk.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular , Stents , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Doenças da Aorta/diagnóstico por imagem , Ruptura Aórtica/cirurgia , Arteriosclerose/cirurgia , Emergências , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Úlcera/cirurgia
16.
Arch Orthop Trauma Surg ; 122(4): 229-34, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-12029513

RESUMO

A follow-up of more than 10 years among patients who have undergone a total knee arthroplasty (TKA) was performed to determine the significance of patella resurfacing for the long-term outcome. The clinical outcome was assessed by the Knee Society Score (KSS), and the radiological outcome was determined based on the Knee Society Roentgenographic Evaluation System. The patella was preserved in 21 knees and resurfaced in 44 knees. The mean follow-up time was 11.6 years (range 10-16.3 years). There was no significant difference in the clinical outcome between the knees with patella resurfacing (knee points: mean 85.3 +/-12.9, function points: mean 70.3 +/- 23.4) and the knees with patella retention (knee points: mean 82.7 +/- 16.2, function points: mean 71.7 +/- 22.4; p = 0.58 for knee, and p = 0.83 for function points). There was also no significant difference in the radiological outcomes regarding the angles alpha, beta, Upsilon, delta, and valgus ( p > 0.05 for each variable). There was, however, a trend towards more lucencies in TKAs with a resurfaced patella on the tibia side in the anteroposterior view ( p = 0.052). Patellar complications were found more often in the resurfaced group (20.5%) than in the group without resurfacing (9.6%). The results indicate overall no advantage of patella resurfacing compared with patella retention in the long run.


Assuntos
Artroplastia do Joelho/métodos , Patela/cirurgia , Adulto , Idoso , Artrite Reumatoide/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Resultado do Tratamento
17.
Clin Radiol ; 57(4): 258-62, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12014869

RESUMO

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon flat panel detector exceeds state of the art storage phosphor radiography. This makes it well suited for skeletal imaging particularly in trauma as seen in the detection of wrist fractures.


Assuntos
Fraturas Ósseas/diagnóstico por imagem , Intensificação de Imagem Radiográfica , Traumatismos do Punho/diagnóstico por imagem , Ecrans Intensificadores para Raios X , Análise de Variância , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Tecnologia Radiológica
18.
Clin Orthop Relat Res ; (399): 184-96, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12011708

RESUMO

For assessment of total knee arthroplasty outcome, various scoring systems have been introduced. The current study assessed the interobserver correlation of four commonly used total knee arthroplasty outcome scores. One hundred eighteen total knee arthroplasties were investigated by two independent observers, using the Hungerford score, the Hospital for Special Surgery score, the Knee Society score, and the Bristol score. Each score consisted of three subscores: pain, knee, and function. For the highest interobserver correlation was computed for the Bristol score (interobserver correlation coefficient, 0.88). For knee range of motion, flexion contracture, and extension lag there was high interobserver correlation (interobserver correlation coefficient > 0.8 each). For walking distance and walking aids, there also was a high interobserver correlation (interobserver correlation coefficient > 0.7 each). For clinical assessment of total knee arthroplasty, pain should be measured on a four-step system, the knee should be assessed by measurement of range of motion, extension lag, and flexion contracture, and function should be measured on a separate score assessing walking distance and walking aids.


Assuntos
Prótese do Joelho/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Osteoartrite do Joelho/cirurgia , Medição da Dor , Satisfação do Paciente , Amplitude de Movimento Articular/fisiologia , Índice de Gravidade de Doença , Resultado do Tratamento , Caminhada/fisiologia
19.
Am J Surg ; 183(1): 75-9, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11869708

RESUMO

BACKGROUND: Severe total hip arthroplasty failure with central migration of prosthetic components is uncommon. If perforation of the medial acetabular wall occurs, injuries of intrapelvic structures may result. DATA SOURCES: A meta-analysis of the English literature was performed. A human pelvic cadaver was used to demonstrate the proximity of intrapelvic structures to a centrally dislocated cup. RESULTS: Fifty cases of intrapelvic injury were identified. Structures involved most frequently were the external iliac artery and the bladder. The most common types of complication included fistula formation, development of a false aneurysm, and hemorrhage. The human cadaver pelvis demonstrated the proximity of intrapelvic vessels, the bladder, the ureter, the vagina, the deferent duct, the sigmoid colon, the rectum, and the sciatic nerve to an intrapelvically intruded prosthesis. CONCLUSIONS: Failed total hip replacements should be considered to cause damage to pelvic viscera.


Assuntos
Artroplastia de Quadril/efeitos adversos , Pelve/lesões , Complicações Pós-Operatórias , Falha de Prótese , Falso Aneurisma/etiologia , Cadáver , Fístula do Sistema Digestório/etiologia , Migração de Corpo Estranho , Hemorragia Gastrointestinal/etiologia , Humanos , Pelve/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...