Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Endovasc Ther ; 17(4): 492-503, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20681765

RESUMO

PURPOSE: To retrospectively evaluate a 12-year experience with endovascular repair of isolated iliac artery aneurysm (IAA). METHODS: From August 1997 through July 2009, 91 patients (81 men; mean age 71 years, range 31-90) underwent endovascular treatment for isolated IAA at our department. Of these, 77 patients received stent-grafts either alone or in combination with coils or an Amplatzer vascular plug (n = 2); 1 patient received a Smart stent combined with coils, and 13 patients were treated with coil embolization only. The aneurysms were classified according to location: type I = common iliac artery (CIA), type II = internal iliac artery (IIA), type III = CIA and IIA, and type IV = external iliac artery with/without CIA and/or IIA involvement. RESULTS: Primary technical success was 90.1% for all aneurysm types and 93.6%, 80%, 88.8%, and 93.3% for types I, II, III, and IV, respectively. Secondary technical success was 96.7% for all types and 97.8%, 95%, 100%, and 93.3%, respectively, for each type. Clinical success was 93.4% for all types and 97.8%, 85%, 100%, and 86.7%, respectively, by type. Complications in 18 (19.8%) patients included 7 type I endoleaks, 3 type II endoleaks, 2 enlarged aneurysm sacs (incomplete embolization), 5 cases of buttock claudication, and 2 stent-graft thromboses. Two patients were converted to open surgery; 10 underwent secondary interventions. Mortality rates were 1.1% (n = 1) at 30 death days and 23.1% (n = 21) over a mean follow-up of 45.9 months (no aneurysm-related death). Cumulative overall survival was 97.7% at 1 year and 47.6% at 10 years. Freedom from aneurysm-related complications was 88.6% at 1 year and 83.5% at 5 years. CONCLUSION: Endovascular repair of isolated IAA is a safe and minimally invasive alternative to surgery. However, it may be associated with several complications and must, therefore, be carefully planned.


Assuntos
Implante de Prótese Vascular , Embolização Terapêutica , Aneurisma Ilíaco/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Áustria , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/instrumentação , Embolização Terapêutica/mortalidade , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/mortalidade , Aneurisma Ilíaco/cirurgia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Estudos Retrospectivos , Medição de Risco , Stents , Taxa de Sobrevida , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
2.
J Vasc Surg ; 49(1): 20-8, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18986789

RESUMO

OBJECTIVE: The aim of this retrospective study was to evaluate aortic volume changes in patients with acute type B aortic dissection (TBD), treated either by thoracic endovascular aortic repair (TEVAR) or conservatively. MATERIALS AND METHODS: From July 1996 through March 2008, 76 patients presenting with acute TBD were referred to our department. To ensure a follow-up of at least 24 months, only 64 of them were included in the present study, with the cut-off for inclusion being March 2006. Twenty-nine of these patients underwent TEVAR and 35 patients underwent conservative treatment. Indications for TEVAR were life-threatening symptoms. Follow-up was performed postinterventionally in patients after TEVAR and at 3, 6, and 12 months, and yearly thereafter in both groups. It included clinical examinations, computed tomography (CT) scans, analysis of volume changes in true thoracic lumen (TTL), false thoracic lumen (FTL), thoracic lumen (TL), abdominal lumen (AL), and aortic diameter measurements. In addition, the extent of thrombosis and its influence on volume changes were assessed. RESULTS: Mean follow-up was 41 months after TEVAR and 46 months in the conservatively-treated patients. At 60 months, cumulative rates of freedom from dissection-related death and rupture-free survival were 82.6% and 93.1% in the TEVAR group, respectively. They were 74.9% and 88.5% in the conservatively-treated group, respectively. In the conservatively-treated patients, 3 patients died of late aortic rupture, 4 were converted to open surgery, and 2 to TEVAR. Evaluation of volume changes showed better results in the TEVAR group within 24 months. However, within 60 months the difference between the two groups was no longer relevant. Relating to thrombosis of the FTL, analyses showed slightly better overall results and promotion of thrombus formation after TEVAR. However, at 60 months the results showed a tendency towards approximation between the two groups. CONCLUSION: Our data suggest that TEVAR seems to delay the natural course of the disease but not to stop it.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/complicações , Dissecção Aórtica/mortalidade , Angiografia Digital , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/mortalidade , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/etiologia , Ruptura Aórtica/cirurgia , Aortografia/métodos , Dilatação Patológica , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/cirurgia , Fatores de Tempo , Tomografia Computadorizada Espiral , Resultado do Tratamento
3.
J Endovasc Ther ; 15(2): 150-60, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18426272

RESUMO

PURPOSE: To evaluate midterm results of endovascular stent-graft placement for acute Stanford type B dissection (TBD). METHODS: A retrospective review was conducted of 35 consecutive patients who were treated with stent-graft implantation for acute TBD between July 1996 and July 2007. Computed tomographic (CT) volumetric analysis of the true lumen (TL) and false lumen (FL) changes in 23 patients was performed, as well as evaluation of the influence of re-entry points and length of stent-graft coverage on volume changes. In addition, complications were evaluated. Follow-up was performed at 6 and 12 months and yearly thereafter. RESULTS: The technical success rate was 82.7%, and the 30-day mortality rate was 8.5%. Mean follow-up was 34 months. The overall survival rate at 5 years was 78.4%. Complications included retrograde type A dissections in 3 patients during the perioperative period and in 1 patient during midterm follow-up. In addition, 5 early and 3 late endoleaks were observed. Three patients were converted to open surgery and 2 needed secondary interventions. In the stented segment, stabilization of the aorta was achieved even during midterm follow-up, with a TL volume increase of 59% at 5 years and nearly stable FL volume. The segment from the distal end of the stent-graft to the celiac artery, however, showed unstable TL and FL volumes, with high standard deviations after the first postinterventional year and circumferential aneurysmal dilatation of the aorta immediately adjacent to the stent-graft in 5 patients. The abdominal aorta showed no substantial volume changes over time. The length of stent-graft coverage and the occurrence of re-entries greatly influenced FL volume changes distal to the stent-graft. CONCLUSION: Serious complications can occur during and after endovascular repair of TBD. Therefore, it should be reserved for high-risk patients.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Stents , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Retrospectivos , Estatísticas não Paramétricas , Taxa de Sobrevida , Tomografia Computadorizada por Raios X , Resultado do Tratamento
4.
Clin Orthop Relat Res ; (399): 184-96, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12011708

RESUMO

For assessment of total knee arthroplasty outcome, various scoring systems have been introduced. The current study assessed the interobserver correlation of four commonly used total knee arthroplasty outcome scores. One hundred eighteen total knee arthroplasties were investigated by two independent observers, using the Hungerford score, the Hospital for Special Surgery score, the Knee Society score, and the Bristol score. Each score consisted of three subscores: pain, knee, and function. For the highest interobserver correlation was computed for the Bristol score (interobserver correlation coefficient, 0.88). For knee range of motion, flexion contracture, and extension lag there was high interobserver correlation (interobserver correlation coefficient > 0.8 each). For walking distance and walking aids, there also was a high interobserver correlation (interobserver correlation coefficient > 0.7 each). For clinical assessment of total knee arthroplasty, pain should be measured on a four-step system, the knee should be assessed by measurement of range of motion, extension lag, and flexion contracture, and function should be measured on a separate score assessing walking distance and walking aids.


Assuntos
Prótese do Joelho/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Osteoartrite do Joelho/cirurgia , Medição da Dor , Satisfação do Paciente , Amplitude de Movimento Articular/fisiologia , Índice de Gravidade de Doença , Resultado do Tratamento , Caminhada/fisiologia
5.
Am J Surg ; 183(1): 75-9, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11869708

RESUMO

BACKGROUND: Severe total hip arthroplasty failure with central migration of prosthetic components is uncommon. If perforation of the medial acetabular wall occurs, injuries of intrapelvic structures may result. DATA SOURCES: A meta-analysis of the English literature was performed. A human pelvic cadaver was used to demonstrate the proximity of intrapelvic structures to a centrally dislocated cup. RESULTS: Fifty cases of intrapelvic injury were identified. Structures involved most frequently were the external iliac artery and the bladder. The most common types of complication included fistula formation, development of a false aneurysm, and hemorrhage. The human cadaver pelvis demonstrated the proximity of intrapelvic vessels, the bladder, the ureter, the vagina, the deferent duct, the sigmoid colon, the rectum, and the sciatic nerve to an intrapelvically intruded prosthesis. CONCLUSIONS: Failed total hip replacements should be considered to cause damage to pelvic viscera.


Assuntos
Artroplastia de Quadril/efeitos adversos , Pelve/lesões , Complicações Pós-Operatórias , Falha de Prótese , Falso Aneurisma/etiologia , Cadáver , Fístula do Sistema Digestório/etiologia , Migração de Corpo Estranho , Hemorragia Gastrointestinal/etiologia , Humanos , Pelve/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...