Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38387612

RESUMO

Congenital LQTS is an often undetected inherited cardiac channel dysfunction and can be a reason for intrauterine fetal demise. It can present in utero as CTG and ultrasound abnormalities, i. e., bradycardia, ventricular tachycardia, or fetal hydrops. Diagnosis is made by CTG, echocardiography, or fMCG. Intrauterine therapy with a ß blocker and i. v. magnesium should be started. Our objective was to examine the current knowledge about diagnosis and treatment of LQTS and in particular to highlight the opportunity of vaginal birth under continuous intravenous magnesium therapy. Therefore, a thorough MEDLINE and Google Scholar search was conducted. Randomized controlled trials, meta-analyses, prospective and retrospective cohort trials, and case reports were considered. We showed the possibility of vaginal delivery under continuous magnesium therapy in a case of suspected fetal LQTS. A stepwise concept for diagnosis, monitoring, and peripartum management in low, intermediate, and high risk cases of fetal LQTS is presented. If risk is low or intermediate, a vaginal delivery under continuous monitoring is reasonable. Induction of labor at term should be evaluated.

2.
Fetal Diagn Ther ; 51(1): 7-15, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37717568

RESUMO

INTRODUCTION: The purpose was to compare thymus size measured during second trimester screening of fetuses who were subsequently small for gestational age at birth (weight below 10th percentile, SGA group) with fetuses with normal birth weight (control group). We hypothesized that measuring the fetal thymic-thoracic ratio (TT-ratio) might help predict low birth weight. METHODS: Using three-vessel view echocardiograms from our archives, we measured the anteroposterior thymus size and the intrathoracic mediastinal diameter to derive TT-ratios in the SGA (n = 105) and control groups (n = 533) between 19+0 and 21+6 weeks of gestation. We analyzed the association between TT-ratio and SGA adjusted to the week of gestation using logistic regression. Finally, we determined the possible TT-ratio cut-off point for discrimination between SGA and control groups by means of receiver operating characteristics (ROC) curve analysis. RESULTS: The TT-ratio was significantly higher in the SGA group than in the control group (p < 0.001). An increase of the TT-ratio by 0.1 was associated with a 3.1-fold increase in the odds of diagnosing SGA. We determined that a possible discrimination cut-off point between SGA and healthy controls was achieved using a TT-ratio of 0.390 (area under the ROC curve 0.695). CONCLUSION: An increased TT-ratio may represent an additional prenatal screening parameter that improves the prediction of birth weight below the 10th percentile. Prospective studies are now needed to evaluate the use of fetal thymus size as predictive parameter for adverse fetal outcome.


Assuntos
Peso Fetal , Ultrassonografia Pré-Natal , Gravidez , Recém-Nascido , Feminino , Humanos , Peso ao Nascer , Terceiro Trimestre da Gravidez , Estudos Prospectivos , Recém-Nascido Pequeno para a Idade Gestacional , Retardo do Crescimento Fetal , Idade Gestacional , Valor Preditivo dos Testes
3.
Arch Gynecol Obstet ; 2023 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-37454353

RESUMO

PURPOSE: To analyze the learning curves of ultrasound novices in fetal echocardiography during structured simulation-based ultrasound training (SIM-UT) including a virtual, randomly moving fetus. METHODS: 11 medical students with minimal (< 10 h) prior obstetric ultrasound experience underwent 12 h of structured fetal echocardiography SIM-UT in individual hands-on sessions during a 6-week training program. Their learning progress was assessed with standardized tests after 2, 4, and 6 weeks of SIM-UT. Participants were asked to obtain 11 fetal echocardiography standard planes (in accordance with ISUOG and AHA guidelines) as quickly as possible. All tests were carried out under real life, examination-like conditions on a healthy, randomly moving fetus. Subsequently, we analyzed the rate of correctly obtained images and the total time to completion (TTC). As reference groups, 10 Ob/Gyn physicians (median of 750 previously performed Ob/Gyn scans) and 10 fetal echocardiography experts (median of 15,000 previously performed Ob/Gyn scans) were examined with the same standardized tests. RESULTS: The students showed a consistent and steady improvement of their ultrasound performance during the training program. After 2 weeks, they were able to obtain > 95% of the standard planes correctly. After 6 weeks, they were significantly faster than the physician group (p < 0.001) and no longer significantly slower than the expert group (p = 0.944). CONCLUSION: SIM-UT is highly effective to learn fetal echocardiography. Regarding the acquisition of the AHA/ISUOG fetal echocardiography standard planes, the students were able to reach the same skill level as the expert group within 6 weeks.

4.
Ultraschall Med ; 44(4): e199-e205, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36882110

RESUMO

OBJECTIVES: To analyze the feasibility of structured ultrasound simulation training (SIM-UT) in teaching second-trimester ultrasound screening using a high-end simulator with a randomly moving fetus. METHODS: This was a prospective, controlled trial. A trial group of 11 medical students with minimal obstetric ultrasound experience underwent 12 hours of structured SIM-UT in individual hands-on sessions within 6 weeks. Learning progress was assessed with standardized tests. Performance after 2, 4, and 6 weeks of SIM-UT was compared with two reference groups ((A) Ob/Gyn residents and consultants, and (B) highly skilled DEGUM experts). Participants were asked to acquire 23 2nd trimester planes according to ISUOG guidelines in a realistic simulation B-mode with a randomly moving fetus as quickly as possible within a 30-minute time frame. All tests were analyzed regarding the rate of appropriately obtained images and the total time to completion (TTC). RESULTS: During the study, novices were able to improve their ultrasound skills significantly, reaching the physician level of the reference group (A) after 8 hours of training. After 12 hours of SIM-UT, the trial group performed significantly faster than the physician group (TTC: 621±189 vs. 1036±389 sec., p=0.011). Novices obtained 20 out of 23 2nd trimester standard planes without a significant time difference when compared to experts. TTC of the DEGUM reference group remained significantly faster (p<0.001) though. CONCLUSION: SIM-UT on a simulator with a virtual, randomly moving fetus is highly effective. Novices can obtain standard plane acquisition skills close to expert level within 12 hours of self-training.


Assuntos
Treinamento por Simulação , Feminino , Gravidez , Humanos , Estudos Prospectivos , Segundo Trimestre da Gravidez , Treinamento por Simulação/métodos , Ultrassonografia , Simulação por Computador , Competência Clínica , Feto
5.
Ultraschall Med ; 44(5): e241-e247, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36198323

RESUMO

PURPOSE: Congenital limb defects are common malformations that are often associated with other organ defects and genetic disorders. Since prenatal detection is challenging and classification is often complex, the aim of this study was to describe a large cohort of fetuses with congenital limb defects and to identify characteristics that are essential for prenatal evaluation, counselling, and management. MATERIALS AND METHODS: In this retrospective cohort study, all cases of confirmed fetal limb defects from two centers for prenatal ultrasound between 2001 and 2021 were evaluated. Cases with skeletal dysplasia were excluded from this study. Demographic data, association with genetic disorders, and correlation with maternal parameters were analyzed statistically. RESULTS: 170 fetuses were included in this study. 60% were diagnosed with a reduction anomaly and 40% with a duplication anomaly. The majority of fetuses were male, and in 73.5% of all cases, additional malformations were present. Among the genetic causes, trisomy 13 and 18 were the most common in this cohort. CONCLUSION: Congenital limb malformations are important markers for complex fetal disorders that warrant referral to specialists in prenatal ultrasound. To improve prenatal detection, care should be taken to visualize all fetal extremities already in early pregnancy.

6.
Z Geburtshilfe Neonatol ; 226(6): 367-376, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36265496

RESUMO

OBJECTIVES: This study was designed to establish new reference charts for BPD (biparietal diameter), OFD (occipitofrontal diameter), HC (head circumference), CM (cisterna magna), TCD (transverse cerebellar diameter), PCV (posterior cerebral ventricle), AC (abdominal circumference), FL (femur length), and HL (humerus length) and extend known charts to 42 weeks of gestation. These new charts were compared to studies carried out by Snijders and Nicolaides, the INTERGROWTH 21st Project, and the WHO Fetal Growth Charts. METHODS: In this retrospective cross-sectional single-center study of 12,972 low-risk pregnancies, biometric data between the 15th and 42nd weeks of gestation were evaluated. Only one examination per pregnancy was selected for statistical analysis. Descriptive analysis for the 5th, 50th, and 95th quantile was performed for each parameter as listed above. Regression models were used to fit the mean and the SD at each gestational age. RESULTS: Initially the reference curves for BPD, OFD, HC, AC, FL, and HL show a linear increase, which changes into a cubic increase towards the end of pregnancy. The results of this study show statistically noticeable differences from the percentile curves of the studies listed above. CONCLUSIONS: The percentile curves in this study differ from the commonly used ones. The presented standard curves can be used as a reference in prenatal diagnostics.


Assuntos
Estudos Transversais , Humanos , Estudos Retrospectivos
7.
J Pers Med ; 12(7)2022 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-35887622

RESUMO

The aim of this study was to identify growth-restricted fetuses using biometric parameters and to assess the validity and clinical value of individual ultrasound parameters and ratios, such as transcerebellar diameter/abdominal circumference (TCD/AC), head circumference/abdominal circumference (HC/AC), and femur length/abdominal circumference (FL/AC). In a retrospective single-center cross-sectional study, the biometric data of 9292 pregnancies between the 15th and 42nd weeks of gestation were acquired. Statistical analysis included descriptive data, quantile regression estimating the 10th and 90th percentiles, and multivariable analysis. We obtained clinically noticeable results in predicting small-for-gestational-age (SGA) and fetal growth restriction (FGR) fetuses at advanced weeks of gestation using the AC with a Youden index of 0.81 and 0.96, respectively. The other individual parameters and quotients were less suited to identifying cases of SGA and FGR. The multivariable analysis demonstrated the best results for identifying SGA and FGR fetuses with an area under the curve of 0.95 and 0.96, respectively. The individual ultrasound parameters were better suited to identifying SGA and FGR than the ratios. Amongst these, the AC was the most promising individual parameter, especially at advanced weeks of gestation. However, the highest accuracy was achieved with a multivariable model.

8.
Arch Gynecol Obstet ; 306(6): 1885-1890, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35296918

RESUMO

OBJECTIVE: To compare the fetal brain structures assessed in routine sonographic scans during the second and third trimesters in fetuses with and without congenital heart disease (CHD). METHODS: This is a retrospective cross-sectional single-center study. We measured the head circumference (HC), the transversal diameter of the cerebellum (TCD) and the sizes of the cisterna magna (CM), the cavum septi pellucidi (CSP) and the posterior ventricles (PV) between 20 and 41 weeks of gestation. We compared 160 fetuses with CHD (case group) to 160 fetuses of normal pregnancies (control group). Every patient was matched with a control, considering the gestational age at which the ultrasound was performed. We divided the CHD group into 3 subgroups: retrograde flow in the aortic arch (group 1), right heart anomaly with the antegrade flow in the aortic arch (group 2) and other CHDs with the antegrade flow in the aortic arch (group 3). RESULTS: The mean width of the PV was larger in fetuses of groups 1 and 3 in comparison to the control group (P < 0.001, P = 0.022; respectively). We found that the APGAR score at 5 min (P < 0.001, P < 0.001; respectively) and gestational age at delivery (P = 0.006, P = 0.001; respectively) were inferior in groups 1 and 3 compared to controls. CONCLUSIONS: Central nervous system biometry is altered in fetuses with CHD. PV is enlarged in CHD fetuses especially with decreased oxygen levels in the aortic arch.


Assuntos
Cardiopatias Congênitas , Ultrassonografia Pré-Natal , Gravidez , Feminino , Humanos , Estudos Retrospectivos , Estudos Transversais , Feto/diagnóstico por imagem , Septo Pelúcido/diagnóstico por imagem , Biometria , Cardiopatias Congênitas/diagnóstico por imagem , Idade Gestacional
9.
J Perinat Med ; 50(2): 144-149, 2022 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-34710316

RESUMO

OBJECTIVES: The aim of this study was to compare the second trimester thymus-thorax-ratio (TTR) between fetuses born preterm (study group) and those born after 37 weeks of gestation were completed (control group). METHODS: This study was conducted as a retrospective evaluation of the ultrasound images of 492 fetuses in the three vessel view. The TTR was defined as the quotient of a.p. thymus diameter and a.p. thoracic diameter. RESULTS: Fetuses that were preterm showed larger TTR (p<0.001) the second trimester than those born after 37 weeks of gestation were completed. The sensitivity of a binary classifier based on TTR for predicting preterm birth (PTB) was 0.792 and the specificity 0.552. CONCLUSIONS: In our study, fetuses affected by PTB showed enlarged thymus size. These findings led us to hypothesize, that inflammation and immunomodulatory processes are altered early in pregnancies affected by PTB. However, TTR alone is not able to predict PTB.


Assuntos
Nascimento Prematuro , Feminino , Feto/diagnóstico por imagem , Humanos , Recém-Nascido , Gravidez , Segundo Trimestre da Gravidez , Nascimento Prematuro/etiologia , Estudos Retrospectivos , Ultrassonografia Pré-Natal/métodos
10.
J Perinat Med ; 50(2): 176-184, 2022 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-34710317

RESUMO

OBJECTIVES: To assess the influence of frame rate settings on longitudinal strain (LS) and mechanical synchrony (SYN) values in Speckle Tracking Echocardiography (STE) of healthy fetuses. METHODS: In this prospective study, we collected transversal or apical four-chamber-views of 121 healthy fetuses between 20 and 38 weeks of gestation using three different frame rate (FR) settings (≥ 110, 100 ± 10, 60 ± 10 frames per second). We assessed the segmental and the global LS of both ventricles (2C) and of the left ventricle (LV) offline with QLab 10.8 (Philips Medical Systems, Andover, MA, USA). Inter- and intraventricular SYN were calculated as time difference in peak myocardial strain between the mid-segments of left and right ventricle (interventricular, 2C_Syn) and lateral wall and septum of the left ventricle (intraventricular, LV_Syn), respectively. RESULTS: In 84.3% STE was feasible at all three FR settings. The LS increased in both views at higher FRs to a statistically noticeable extent. SYN measurements and the absolute differences at patient level between the FR settings showed no statistically noticeable alterations. CONCLUSIONS: STE is feasible at low and high FR settings. SYN emerges to be a robust parameter for fetal STE as it is less affected by the FR. High FRs enable high temporal resolutions and thus an accurate examination of fetal hearts. Future research for the technical implementation of tailored fetal STE software is necessary for reliable clinical application.


Assuntos
Coração Fetal , Ultrassonografia Pré-Natal , Ecocardiografia , Feminino , Coração Fetal/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Humanos , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes
11.
J Perinat Med ; 49(5): 604-613, 2021 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-33561911

RESUMO

OBJECTIVES: The aim of this study was to investigate the correlation between fetal thymus size measured during first-trimester screening and chromosomal anomalies. METHODS: This study is a retrospective evaluation, in which the anterior-posterior diameter of the thymus in a midsagittal plane was measured in first-trimester ultrasound between 11+0 and 13+6 weeks of gestation in 168 fetuses with chromosomal anomalies (study group) and 593 healthy fetuses (control group). The included cases were subdivided into six groups: (1) trisomy 21, (2) trisomy 18, (3) trisomy 13, (4) Turner syndrome, (5) triploidy and (6) normal controls. Thymus size measurements were adjusted to the week of gestation, which was determined by ultrasound using crown-rump-length (CRL), by calculating a ratio between CRL and thymus size (CRL-thymus-ratio). Each study group was compared with the control group separately. RESULTS: Thymus size in fetuses affected by trisomy 18 or trisomy 13 was noticeably smaller compared to the control group (1.4 mm [1.3, 1.5] and 1.3 mm [1.2, 1.4] vs. 1.8 mm [1.6, 2.1]; all p<0.001; respectively). The thymus size of fetuses with trisomy 21 and Turner syndrome did not differ from healthy fetuses. Between the CRL-thymus-ratios of the separate study groups no statistically noticeable differences could be found. CONCLUSIONS: Fetal thymus size appeared to be smaller in pregnancies affected by trisomy 18 and trisomy 13. The predictive value of fetal thymus size in first-trimester screening should be evaluated prospectively.


Assuntos
Transtornos Cromossômicos , Feto/diagnóstico por imagem , Diagnóstico Pré-Natal , Timo , Ultrassonografia Pré-Natal , Adulto , Transtornos Cromossômicos/classificação , Transtornos Cromossômicos/diagnóstico , Feminino , Humanos , Masculino , Tamanho do Órgão , Valor Preditivo dos Testes , Gravidez , Primeiro Trimestre da Gravidez , Diagnóstico Pré-Natal/métodos , Diagnóstico Pré-Natal/estatística & dados numéricos , Reprodutibilidade dos Testes , Timo/diagnóstico por imagem , Timo/patologia , Síndrome da Trissomia do Cromossomo 13/diagnóstico , Síndrome da Trissomía do Cromossomo 18/diagnóstico , Ultrassonografia Pré-Natal/métodos , Ultrassonografia Pré-Natal/estatística & dados numéricos
12.
J Perinat Med ; 48(1): 67-73, 2019 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-31677377

RESUMO

Objective To reveal the effect of a maternal human immunodeficiency virus (HIV) infection on the fetal thymus size. Methods The sonographic fetal thymus size was measured retrospectively in 105 pregnancies with maternal HIV infection and in 615 uncomplicated singleton pregnancies. The anteroposterior thymic and the intrathoracic mediastinal diameter were determined in the three-vessel view and their quotient, the thymic-thoracic ratio (TT ratio), was calculated. The study group was subdivided into three groups by the maternal viral load on the date of ultrasound (<50 cop./mL, 50-1000 cop./mL, >1000 cop./mL). Furthermore, an association between prognostic factors of the HIV infection such as the lymphocyte count, CD4/CD8 ratio, HIV medication and the thymus size, was investigated using correlation analyses. Results Fetal thymus size in pregnancies of HIV-positive mothers showed to be noticeably larger than in uncomplicated pregnancies. The mean TT ratio in the HIV-positive group was 0.389 and in the control group 0.345 (P < 0.001). There was no association between any maternal HIV parameter or medication and the size of the thymus gland. Conclusion Maternal HIV infection was associated with an increased fetal thymus size. Further consequences of intrauterine HIV exposure for fetal outcome and the development of the immune system of HIV-exposed uninfected (HEU) infants must be discussed.


Assuntos
Feto/diagnóstico por imagem , Infecções por HIV/diagnóstico por imagem , Complicações Infecciosas na Gravidez/diagnóstico por imagem , Timo/diagnóstico por imagem , Estudos de Casos e Controles , Feminino , Humanos , Tamanho do Órgão , Gravidez , Ultrassonografia Pré-Natal
13.
J Perinat Med ; 47(8): 811-816, 2019 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-31503543

RESUMO

Background The aim of this study was to compare transabdominal and transcervical chorionic villus sampling (CVS) as well as amniocentesis (AC) with respect to their rates of premature delivery and fetal growth restriction. Methods We retrospectively evaluated the mentioned procedures of invasive prenatal testing performed in a single center between 2001 and 2016. Seven hundred and ninety-nine cases of AC and 719 cases of CVS were included, of which 400 were performed transvaginally. Only singleton pregnancies with a normal karyotype and delivery after 24 + 0 weeks of gestation were included. Fetal growth restriction was defined as birth weight below the 10th percentile. Premature delivery was defined as delivery before 37 + 0 weeks of gestation. Data were compared to a control group without an invasive procedure. Results The frequency of premature delivery was 8.5% after transabdominal CVS, 6.3% after transcervical CVS and 10.5% after AC as compared to 10.8% in the control group. The frequency of fetal growth restriction was 8.2% after transabdominal CVS 6.8% after transcervical CVS and 8.4% after AC as compared to 9.7% in the control group. Conclusion Our study supports that the three different methods of invasive prenatal testing do not lead to a higher risk of either premature delivery or fetal growth restriction when compared to controls. We found no difference in risk profile among the three techniques.


Assuntos
Amniocentese/efeitos adversos , Amostra da Vilosidade Coriônica/efeitos adversos , Retardo do Crescimento Fetal/etiologia , Nascimento Prematuro/etiologia , Adulto , Feminino , Humanos , Gravidez , Estudos Retrospectivos
14.
J Perinat Med ; 47(6): 598-604, 2019 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-31141490

RESUMO

Objective To compare myocardial strain and mechanical dyssynchrony in fetuses with congenital heart disease (CHD) to normal controls using speckle tracking echocardiography (STE). Methods In this comparative cross-sectional study 23 fetuses with CHD and 105 normal controls between 19 and 41 weeks of gestation were assessed with STE. The STE sample box was placed over the myocardium of both ventricles. The parameters of interest included the segmental strain of the left (LV-S) and right lateral ventricle wall (RV-S) and the global ventricular strain of both chambers (2C-S). In order to separately assess the LV, we placed the STE sample box over the myocardium of the LV. We calculated the strain of the LV lateral wall (LW-S), the septum (SEPT-S) and the global ventricular strain of the single LV (1C-S). Furthermore, we analyzed the differences in timing of negative peak myocardial strain between the LV and RV (two-chamber dyssynchrony, 2C-DYS) and also within the LV between the lateral wall and the septum (one-chamber dyssynchrony, 1C-DYS). Results The evaluation of strain and mechanical dyssynchrony was feasible in all cases. Compared to normal controls, fetuses with CHD showed lower segmental and global strain values and the extent of 2C-DYS and 1C-DYS was higher than in the healthy control group. Conclusion The deterioration of myocardial function in CHD can be measured with STE. The assessment of strain and dyssynchrony with STE may be useful for distinguishing fetuses with CHD from healthy fetuses.


Assuntos
Ecocardiografia/métodos , Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas , Ventrículos do Coração , Ultrassonografia Pré-Natal/métodos , Fenômenos Fisiológicos Cardiovasculares , Feminino , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Gravidez , Reprodutibilidade dos Testes
16.
PLoS One ; 13(7): e0199581, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29965971

RESUMO

AIMS: To determine if atrial tissue deformation (peak strain, PS) and time to peak strain (TTPS) can be assessed in the fetus, with identification of best echocardiographic plane. MATERIALS AND METHODS: Pulsed-wave tissue Doppler study of a longitudinal and a transverse four-chamber view (FCV) in each of 20 healthy fetuses. Determination of PS and TTPS in regions of interest (ROI), viz., lateral walls of the right and left atria (RA, LA); comparison of values depending on section plane, with results-based discussion of the physiology of fetal atrial deformation and of possible clinical uses. RESULTS: PS and TTPS could be determined on transverse FCV in 91% of subjects and in 61% on longitudinal FCV. Transverse PS and TTPS were significantly higher than longitudinal (p = 0.0001). Transverse PS was significantly higher in RA than in LA (26.9% vs. 17.3%, p = 0.034), and transverse TTPS was significantly shorter in RA than in LA (p = 0.034). CONCLUSION: Atrial radial PS and TTPS determinations are possible in the fetus. The transverse FCV is best suited for these. The highest PS values and shortest TTPS values are found in ROI representing the RA. Our findings may contribute to detailed intrauterine assessment of atrial and ventricular myocardial function.


Assuntos
Coração Fetal/diagnóstico por imagem , Coração Fetal/patologia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Função do Átrio Esquerdo , Ecocardiografia , Átrios do Coração/fisiopatologia , Testes de Função Cardíaca , Humanos
17.
Arch Gynecol Obstet ; 298(2): 329-336, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29926171

RESUMO

PURPOSE: The aim of our study was to compare thymus sizes in foetuses conceived using assisted reproductive technologies (ART) to those conceived naturally (control group). METHODS: Sonographic foetal thymus size was assessed retrospectively in 162 pregnancies conceived using ART and in 774 pregnancies conceived naturally. The anteroposterior thymic and the intrathoracic mediastinal diameter were measured to calculate the thymic-thoracic ratio (TT-ratio). The ART cases were subdivided into two groups: (1) intracytoplasmic sperm injection (ICSI; n = 109) and (2) in vitro fertilisation (IVF; n = 53). RESULTS: The TT-ratio was smaller in pregnancies conceived using ART (p < 0.001). In both ART subgroups (ICSI and IVF), the TT-ratio was lower compared to the control group (p < 0.001). However, no difference between the two subgroups could be detected (p = 0.203). CONCLUSIONS: Our data show reduced thymus size in foetuses conceived using ART compared to controls. These findings indicate that the use of ART may lead to certain deviations in organogenesis.


Assuntos
Desenvolvimento Fetal , Técnicas de Reprodução Assistida , Timo/embriologia , Feminino , Fertilização in vitro , Feto/diagnóstico por imagem , Humanos , Masculino , Análise Multivariada , Organogênese , Gravidez , Estudos Retrospectivos , Injeções de Esperma Intracitoplásmicas , Timo/diagnóstico por imagem
18.
Ultraschall Med ; 39(1): 56-68, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-26844710

RESUMO

PURPOSE: To assess the time intervals of the cardiac cycle in healthy fetuses in the second and third trimester using color tissue Doppler imaging (cTDI) and to evaluate the influence of different sizes of sample gates on time interval values. MATERIALS AND METHODS: Time intervals were measured from the cTDI-derived Doppler waveform using a small and large region of interest (ROI) in healthy fetuses. RESULTS: 40 fetuses were included. The median gestational age at examination was 26 + 1 (range: 20 + 5 - 34 + 5) weeks. The median frame rate was 116/s (100 - 161/s) and the median heart rate 143 (range: 125 - 158) beats per minute (bpm). Using small and large ROIs, the second trimester right ventricular (RV) mean isovolumetric contraction times (ICTs) were 39.8 and 41.4 ms (p = 0.17), the mean ejection times (ETs) were 170.2 and 164.6 ms (p < 0.001), the mean isovolumetric relaxation times (IRTs) were 52.8 and 55.3 ms (p = 0.08), respectively. The left ventricular (LV) mean ICTs were 36.2 and 39.4 ms (p = 0.05), the mean ETs were 167.4 and 164.5 ms (p = 0.013), the mean IRTs were 53.9 and 57.1 ms (p = 0.05), respectively. The third trimester RV mean ICTs were 50.7 and 50.4 ms (p = 0.75), the mean ETs were 172.3 and 181.4 ms (p = 0.49), the mean IRTs were 50.2 and 54.6 ms (p = 0.03); the LV mean ICTs were 45.1 and 46.2 ms (p = 0.35), the mean ETs were 175.2 vs. 172.9 ms (p = 0.29), the mean IRTs were 47.1 and 50.0 ms (p = 0.01), respectively. CONCLUSION: Isovolumetric time intervals can be analyzed precisely and relatively independent of ROI size. In the near future, automatic time interval measurement using ultrasound systems will be feasible and the analysis of fetal myocardial function can become part of the clinical routine.


Assuntos
Coração Fetal , Frequência Cardíaca Fetal , Ultrassonografia Pré-Natal , Ecocardiografia Doppler , Feminino , Coração Fetal/diagnóstico por imagem , Idade Gestacional , Humanos , Gravidez , Segundo Trimestre da Gravidez , Terceiro Trimestre da Gravidez , Valores de Referência
19.
Arch Gynecol Obstet ; 295(5): 1157-1165, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28337595

RESUMO

PURPOSE: To study the role of the TTR-RBP4-ROH complex components (transthyretin, serum retinol binding protein, retinol) and of angiogenic factors PlGF (placental growth factor) and sFlt-1 (soluble fms-like tyrosine kinase-1) in pregnancies complicated by small for gestational age infants (SGA). METHODS: Case control study conducted on maternal serum collected between 11 + 0 to 13 + 6 weeks of gestation. TTR, RBP4, ROH, PlGF and sFlt-1 were measured in SGA patients (birth weight <10%) who delivered at term (n = 37) and before 37 weeks of gestation (n = 17) and in a matched control group with uneventful pregnancies (n = 37). RESULTS: We found decreased RBP4 in SGA patients that delivered fetuses <3% and in fetuses delivered after the 37 weeks of gestation compared to controls [1.50 (95% CI 1.40-1.75) vs 1.62 (95% CI 1.47-1.98), p < 0.05]. Further, we found lower PlGF and sFlt-1 concentrations in SGA that delivered before 37 weeks of gestation compared to controls (respectively, PIGF and sFlt-1: 39.7 pg/ml (95% CI 32.3-66.3) vs 62.9 pg/ml (95% CI 45.2-78.4) and 906 pg/ml (95% CI 727-1626) vs 1610 pg/ml (95% CI 1088-212), p < 0.05). CONCLUSIONS: First trimester maternal serum RBP4 and angiogenic factors PlGF and sFlt-1 can differently predict the timing of delivery of pregnancies complicated by SGA fetuses.


Assuntos
Recém-Nascido Pequeno para a Idade Gestacional/sangue , Pré-Albumina/análise , Proteínas Plasmáticas de Ligação ao Retinol/análise , Vitamina A/sangue , Peso ao Nascer , Estudos de Casos e Controles , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Fator de Crescimento Placentário/sangue , Pré-Eclâmpsia/sangue , Gravidez , Primeiro Trimestre da Gravidez/sangue , Receptor 1 de Fatores de Crescimento do Endotélio Vascular/sangue
20.
Ultraschall Med ; 38(4): 403-410, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26331331

RESUMO

Purpose To evaluate pre- and post-procedure myocardial function in monochorionic twins with TTTS who underwent laser ablation of placental anastomoses using pulsed wave tissue Doppler imaging (pw TDI). Materials and Methods 20 monochorionic twin gestations with TTTS were included and underwent laser ablation at our center between 2011 and 2014. Prior to and after the intervention, cardiac function was assessed by measuring the mitral annular plane systolic excursion (MAPSE), the tricuspid annular plane systolic excursion (TAPSE), Tei index, isovolumetric contraction time (ICT), ejection time (ET), isovolumetric relaxation time (IRT) for the left ventricle in pulsed wave Doppler (pw D) ultrasound as well as ICT, ET, IRT and Tei index in pw TDI for the left and right ventricle. E-, A-, E´- and A´-wave peak velocity and the systolic downward motion (S´) were measured for both ventricles and the E/A, E/E´ and E´/A´ ratios were calculated. In a mean of 1.3 (SD 0.6) days after laser ablation, this measurement protocol was repeated. Results Pre-intervention recipients had longer ICT, ET and IRT in pw D and pw TDI compared to donors not reaching statistical significance for most parameters. Statistically significant were prolonged ICT in pw D (p 0.01) and ET (p 0.01) in pw TDI in recipients. In donor fetuses preoperative myocardial function did not differ significantly from postoperative myocardial function except in increased left ventricular ejection time of the left ventricle in pw TDI (p 0.04) and an increased E´/A´ratio (p 0.01). After laser coagulation, myocardial function was slightly altered in recipients as ICT and IRT shortened and Tei indices decreased but only reaching statistical significance in shortened IRTs in pw TDI for both ventricles. Conclusion Laser ablation of placental anastomoses in TTTS might influence myocardial function in the postoperative period. Shortened IRT intervals may reflect an improvement of diastolic function in recipients.


Assuntos
Transfusão Feto-Fetal , Terapia a Laser , Feminino , Transfusão Feto-Fetal/terapia , Feto , Ventrículos do Coração , Humanos , Placenta/cirurgia , Gravidez , Sístole
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...