Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1311: 1-10, 2013 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-24011723

RESUMO

Bar adsorptive micro-extraction (BAµE), using selective sorbent phases, followed by liquid desorption in combination with high performance liquid chromatography-diode array detection (BAµE-LD/HPLC-DAD), is proposed for the determination of trace levels of four benzophenone-type UV filters (benzophenone, 2-hydroxy-4-methoxy-benzophenone, 2,4-hydroxybenzophenone and 4-hydroxybenzophenone) in real matrices. By comparing three polymers (P1, P2 and P3) and five activated carbons (AC1, AC2, AC3, AC4 and AC5) phases, P2 (a modified pyrrolidone polymer) and AC4 coatings showed much higher selectivity and capacity through BAµE, where the former offers multiple mechanisms of interaction and faster equilibrium kinetics. Assays performed on 25mL of ultra-pure water samples spiked at the 8.0µg/L level, yielded recoveries ranging from 76.6±8.3% to 103.5±6.4% depending on the sorbent phase used (P2 or AC4), under optimized experimental conditions. The analytical performance showed convenient detection limits (0.3-0.5µg/L) and good linear dynamic ranges (1.0-24.0µg/L) with remarkable determination coefficients (r(2)>0.9969). Excellent repeatability was also achieved through intraday (RSD<13.0%) and interday (RSD<8.9%) experiments. By using the standard addition methodology, the application of the present analytical approach on sea water, wastewater, commercial cosmetic products and urine samples revealed good sensitivity, absence of matrix effects and the occurrence of levels of some benzophenones. The proposed methodology that uses nanostructured particles and operates under the floating sampling technology proved to be a sorption-based static micro-extraction alternative to monitor benzophenone-type UV filters in real matrices. Moreover, is easy to implement, reliable, sensitive, requiring low sample volume and the possibility to choose the most selective sorbent coating according to the target compounds involved.


Assuntos
Benzofenonas/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Microextração em Fase Sólida/métodos , Protetores Solares/isolamento & purificação , Poluentes Químicos da Água/isolamento & purificação , Adsorção , Benzofenonas/urina , Carvão Vegetal/química , Cosméticos/análise , Humanos , Limite de Detecção , Água do Mar/análise , Águas Residuárias/análise , Poluentes Químicos da Água/urina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...