Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dalton Trans ; 53(13): 6031-6040, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38470348

RESUMO

BOLD-100 (formerly IT-139, KP1339), a well-established chemotherapeutic agent, is currently being investigated in clinical trials for the treatment of gastric, pancreatic, colorectal, and bile duct cancer. Despite numerous studies, the exact mode of action is still the subject of discussions. Radiolabeled BOLD-100 could be a powerful tool to clarify pharmacokinetic pathways of the compound and to predict therapy responses in patients using nuclear molecular imaging prior to the therapy. In this study, the radiosyntheses of carrier-added (c.a.) [97/103Ru]BOLD-100 were performed with the two ruthenium isotopes ruthenium-103 (103Ru; ß-, γ) and ruthenium-97 (97Ru; EC, γ), of which in particular the latter isotope is suitable for imaging by single-photon emission computed tomography (SPECT). To identify the best tumor-to-background ratio for diagnostic imaging, biodistribution studies were performed with two different injected doses of c.a. [103Ru]BOLD-100 (3 and 30 mg kg-1) in Balb/c mice bearing CT26 allografts over a time period of 72 h. Additionally, ex vivo autoradiography of the tumors (24 h p.i.) was conducted. Our results indicate that the higher injected dose (30 mg kg-1) leads to more unspecific accumulation of the compound in non-targeted tissue, which is likely due to an overload of the albumin transport system. It was also shown that lower amounts of injected c.a. [103Ru]BOLD-100 resulted in a relatively higher tumor uptake and, therefore, a better tumor-to-background ratio, which are encouraging results for future imaging studies using c.a. [97Ru]BOLD-100.


Assuntos
Antineoplásicos , Neoplasias , Compostos Organometálicos , Radioisótopos de Rutênio , Rutênio , Animais , Camundongos , Humanos , Distribuição Tecidual , Antineoplásicos/farmacologia
2.
Phys Rev Lett ; 114(4): 041101, 2015 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-25679883

RESUMO

In order to resolve a recent discrepancy in the half-life of 60Fe, we performed an independent measurement with a new method that determines the 60Fe content of a material relative to 55Fe (t1/2=2.744 yr) with accelerator mass spectrometry. Our result of (2.50±0.12)×10(6) yr clearly favors the recently reported value (2.62±0.04)×10(6) yr, and rules out the older result of (1.49±0.27)×10(6) yr. The present weighted mean half-life value of (2.60±0.05)×10(6) yr substantially improves the reliability as an important chronometer for astrophysical applications in the million-year time range. This includes its use as a sensitive probe for studying recent chemical evolution of our Galaxy, the formation of the early Solar System, nucleosynthesis processes in massive stars, and as an indicator of a recent nearby supernova.

3.
Nucl Instrum Methods Phys Res A ; 735: 229-239, 2014 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-25844000

RESUMO

The Thorium-229 isotope features a nuclear isomer state with an extremely low energy. The currently most accepted energy value, 7.8±0.5 eV, was obtained from an indirect measurement using a NASA x-ray microcalorimeter with an instrumental resolution 26 eV. We study, how state-of-the-art magnetic metallic microcalorimeters with an energy resolution down to a few eV can be used to measure the isomer energy. In particular, resolving the 29.18 keV doublet in the γ-spectrum following the α-decay of Uranium-233, corresponding to the decay into the ground and isomer state, allows to measure the isomer transition energy without additional theoretical input parameters, and increase the energy accuracy. We study the possibility of resolving the 29.18 keV line as a doublet and the dependence of the attainable precision of the energy measurement on the signal and background count rates and the instrumental resolution.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA