1.
Opt Express ; 31(17): 27667-27676, 2023 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-37710837

RESUMO

We characterized and analyzed the effect of intracavity spectral filtering in the Er:fiber laser mode-locked with a semiconductor saturable absorber mirror (SESAM). We studied the dispersive properties of bandpass filters and their influence on the characteristics of generated soliton pulses. Our analysis showed that various sideband structures were induced by the filter dispersion profiles and shaped through the interaction of the soliton with the dispersive wave. In addition, intracavity filtering improved the intensity and phase noise of the laser significantly, and we showed optimal filtering conditions for both types of noise. By adding a 10 nm bandpass filter to the laser resonator, the intensity and phase noise were improved 2- and 2.6 times, respectively.

2.
Nat Commun ; 14(1): 3339, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37286534

RESUMO

Optical solitary waves (solitons) that interact in a nonlinear system can bind and form a structure similar to a molecule. The rich dynamics of this process have created a demand for rapid spectral characterization to deepen the understanding of soliton physics with many practical implications. Here, we demonstrate stroboscopic, two-photon imaging of soliton molecules (SM) with completely unsynchronized lasers, where the wavelength and bandwidth constraints are considerably eased compared to conventional imaging techniques. Two-photon detection enables the probe and tested oscillator to operate at completely different wavelengths, which permits mature near-infrared laser technology to be leveraged for rapid SM studies of emerging long-wavelength laser sources. As a demonstration, using a 1550 nm probe laser we image the behavior of soliton singlets across the 1800-2100 nm range, and capture the rich dynamics of evolving multiatomic SM. This technique may prove to be an essential, easy-to-implement diagnostic tool for detecting the presence of loosely-bound SM, which often remain unnoticed due to instrumental resolution or bandwidth limitations.

3.
Opt Express ; 30(16): 28427-28437, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-36299038

RESUMO

We present quasi-real-time dual-comb spectroscopy (DCS) using two Yb:fiber combs with ∼750 MHz repetition rates. A computational coherent averaging technique is employed to correct timing and phase fluctuations of the measured dual-comb interferogram (IGM). Quasi-real-time phase correction of 1-ms long acquisitions occurs every 1.5 seconds and is assisted by coarse radio frequency (RF) phase-locking of an isolated RF comb mode. After resampling and global offset phase correction, the RF comb linewidth is reduced from 200 kHz to ∼1 kHz, while the line-to-floor ratio increases 13 dB in power in 1 ms. Using simultaneous offset frequency correction in opposite phases, we correct the aliased RF spectrum spanning three Nyquist zones, which yields an optical coverage of ∼180 GHz around 1.035 µm probed on a sub-microsecond timescale. The absorption profile of gaseous acetylene is observed to validate the presented technique.

4.
Opt Lett ; 47(7): 1762-1765, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35363729

RESUMO

We report on the first, to the best of our knowledge, solid-state dual-comb mode-locked laser that simultaneously operates in different dispersion regimes. Due to the intrinsic polarization multiplexing in a birefringent Yb:Ca3NbGa3Si2O14 (Yb:CNGS) gain medium, the laser emits two cross-polarized pulse trains with a repetition rate offset of ∼ 4.8 kHz from a single cavity. We obtain dual pulse generation with a 20-fold difference in duration by setting the net cavity group delay dispersion to cross zero across the emission band of the employed gain medium. While the duration of the soliton-like pulses experiencing anomalous dispersion amounts to 117 fs, the second laser output, which is spectrally located in the normal dispersion region, is strongly chirped with a pulse duration of 2360 fs.

5.
Opt Lett ; 45(17): 4895-4898, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32870896

RESUMO

We demonstrate a technique to compress spectral information in dual-comb spectroscopy that relies on subsampling of the electrical interferogram. It enables us to reduce the data sample rate by arbitrary factors directly in the sampling process or in post-processing of existing data. A demonstration code is provided.

6.
Opt Lett ; 44(23): 5828-5831, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31774790

RESUMO

The interband cascade laser (ICL) is an ideal candidate for low-power mid-infrared frequency comb spectroscopy. In this work, we demonstrate that its intracavity second-order optical nonlinearity induces a coherent up-conversion of the generated mid-infrared light to the near-infrared through second-harmonic and sum-frequency generation. At 1.8 µm, 10 mW of light at 3.6 µm convert into sub-nanowatt levels of optical power, spread across 30 nm of spectral coverage. The observed linear-to-nonlinear conversion efficiency exceeds ${3\;{\unicode{x00B5} {\rm W/W}}^2}$3µW/W2 in continuous wave operation. We use a dual-band ICL frequency comb source to characterize water vapor absorption in both spectral bands.

7.
Opt Express ; 27(17): 23875-23893, 2019 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-31510286

RESUMO

Dual-comb spectroscopy is a rapidly developing spectroscopic technique that does not require any opto-mechanical moving parts and enables broadband and high-resolution measurements with microsecond time resolution. However, for high sensitivity measurements and extended averaging times, high mutual coherence of the comb-sources is essential. To date, most dual-comb systems employ coherent averaging schemes that require additional electro-optical components, which increase system complexity and cost. More recently, computational phase correction approaches that enables coherent averaging of spectra generated by free-running systems have gained increasing interest. Here, we propose such an all-computational solution that is compatible with real-time data acquisition architectures for free-running systems. The efficacy of our coherent averaging algorithm is demonstrated using dual-comb spectrometers based on quantum cascade lasers, interband cascade lasers, mode-locked lasers, and optically-pumped microresonators.

8.
Opt Lett ; 44(8): 2113-2116, 2019 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-30985824

RESUMO

Two semiconductor optical frequency combs, consuming less than 1 W of electrical power, are used to demonstrate high-sensitivity mid-infrared dual-comb spectroscopy in the important 3-4 µm spectral region. The devices are 4 mm long by 4 µm wide, and each emits 8 mW of average optical power. The spectroscopic sensing performance is demonstrated by measurements of methane and hydrogen chloride with optical multi-pass cell sensitivity enhancement. The system provides a spectral coverage of 33 cm-1 (1 THz), 0.32 cm-1 (9.7 GHz) frequency sampling interval, and peak signal-to-noise ratio of ∼100 at 100 µs integration time. The monolithic design, low drive power, and direct generation of mid-infrared radiation are highly attractive for portable broadband spectroscopic instrumentation in future terrestrial and space applications.

9.
Opt Lett ; 43(18): 4522-4525, 2018 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-30211906

RESUMO

In this Letter, we report on sub-millisecond response time mid-infrared dual-comb spectroscopy using a balanced asymmetric (dispersive) dual-comb setup with a matched pair of plasmon-enhanced-waveguide dispersion-compensated quantum cascade lasers. The system performance is demonstrated by measuring spectra of Bromomethane (CH3Br) and Freon 134a (CH2FCF3) at approximately 7.8 µm. A purely computational phase and timing-correction procedure is used to validate the coherence of the quantum cascade lasers frequency combs and to enable coherent averaging over the time scales investigated. The system achieves a noise-equivalent absorption better than 1×10-3 Hz-1/2, with a resolution of 9.8 GHz (0.326 cm-1) and an optical bandwidth of 1 THz (32 cm-1), with an average optical power of more than 1 mW per spectral element.

10.
Sci Rep ; 8(1): 3322, 2018 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-29463807

RESUMO

Since their inception, optical frequency combs have transformed a broad range of technical and scientific disciplines, spanning time keeping to navigation. Recently, dual comb spectroscopy has emerged as an attractive alternative to traditional Fourier transform spectroscopy, since it offers higher measurement sensitivity in a fraction of the time. Midwave infrared (mid-IR) frequency combs are especially promising as an effective means for probing the strong fundamental absorption lines of numerous chemical and biological agents. Mid-IR combs have been realized via frequency down-conversion of a near-IR comb, by optical pumping of a micro-resonator, and beyond 7 µm by four-wave mixing in a quantum cascade laser. In this work, we demonstrate an electrically-driven frequency comb source that spans more than 1 THz of bandwidth centered near 3.6 µm. This is achieved by passively mode-locking an interband cascade laser (ICL) with gain and saturable absorber sections monolithically integrated on the same chip. The new source will significantly enhance the capabilities of mid-IR multi-heterodyne frequency comb spectroscopy systems.

11.
Sci Rep ; 7(1): 14583, 2017 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-29109507

RESUMO

In this paper we discuss the link between the domain of physical parameters - molecular descriptors of a drug, and terahertz (THz) spectra. We measured the derivatives of the well-known anti-inflammatory drug Piroxicam using THz spectroscopy and employed Principal Component Analysis to build similarity maps in the molecular descriptor and spectral domains. We observed, that the spatial neighborhood on the molecular descriptors map is highly correlated with the spectral neighbourhood within a group of structurally-similar molecules. We built a Partial Least Squares (PLS) predictive model to quantify the relationship between the spectra and the melting point, which can guide the selection of early drug candidates.


Assuntos
Desenvolvimento de Medicamentos/métodos , Espectroscopia Terahertz/métodos , Anti-Inflamatórios/química , Análise dos Mínimos Quadrados , Piroxicam/química , Análise de Componente Principal
12.
Opt Lett ; 42(2): 243-246, 2017 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-28081083

RESUMO

Two Fabry-Perot quantum cascade lasers are used in a differential dual comb configuration to perform rapidly swept dispersion spectroscopy of low-pressure nitrous oxide with <1 ms acquisition time. Active feedback control of the laser injection current enables simultaneous wavelength modulation of both lasers at kilohertz rates. The system demonstrates similar performance in both absorption and dispersion spectroscopy modes and achieves a noise-equivalent absorption figure of merit in the low 10-4/Hz range.