Resultados 1 - 20 de 274
Filtrar
1.
J Hypertens ; 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38690918

RESUMO

OBJECTIVE: A novel automated auscultatory upper-arm cuff blood pressure (BP) monitor for office use (KOROT P3 Accurate, previously InBody BPBIO480KV), which displays Korotkoff sound curves for each BP reading was recently developed. This study investigated whether the review of Korotkoff sound curves by healthcare professionals further improves the accuracy of the device by identifying unreliable BP readings. METHODS: Three observers assessed independently the morphology of Korotkoff sound curves of BP measurements obtained during an ISO 81060-2:2018 validation study, and classified them as of good, fair, or poor quality (low amplitude or sound intensity, aberrant morphology, background noise, signal artifact, auscultatory gap, irregular rhythm). The observers were blinded to the study BP measurements. RESULTS: Korotkoff sound curves of 255 BP readings obtained in 85 individuals were analyzed (mean age 57.3 ±â€Š15.0 years, 53 men). Of the SBP readings 80.4/12.2/7.4% were classified as good/fair/poor, and DBP 76.9/12.2/10.9%. Inter-observer agreement in detecting poor-quality curves was 84.7/83.1% (systolic/diastolic). Of poor-quality curves, 10.5/60.7% (systolic/diastolic) clustered in the same individuals. The validation criterion 1 [mean test-reference BP difference ≤5 ±â€Š8 (SD) mmHg] was satisfied for readings with good (0.1 ±â€Š4.9/0.3 ±â€Š3.8 mmHg, systolic/diastolic) and fair-quality curves (-0.4 ±â€Š6.4/0.2 ±â€Š5.0), but not for poor-quality ones (2.7 ±â€Š8.8/3.6 ±â€Š8.1). By excluding poor-quality readings (40 of 255), criterion 1 of the validation study was improved (0.2 ±â€Š4.9/0.2 ±â€Š3.9 versus 0.3 ±â€Š5.5/0.6 ±â€Š4.7 mmHg). CONCLUSION: The visual assessment of Korotkoff sounds generated during automated auscultatory BP measurement by the KOROT P3 Accurate professional monitor identifies unreliable readings and further improves the device accuracy.

2.
J Hypertens ; 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38690937

RESUMO

OBJECTIVES: Blood pressure (BP) variability (BPV) can be assessed using office (OBP), home (HBP), or ambulatory BP (ABP) measurements. This analysis investigated the association and agreement between OBP, HBP, and ABP measurements for BPV assessment at baseline and 10 weeks after initiating antihypertensive drug therapy. METHODS: Untreated hypertensive patients with elevated BPV were randomized to receive an angiotensin-converting enzyme inhibitor (ramipril) or a calcium channel blocker (nifedipine GITS) in a 10-week, open-label, blinded-end point study. BPV was assessed using standard deviation (SD) and coefficient of variation (CV) (reading-to-reading analyses). RESULTS: Data from 146 participants from three research centers (Athens/Greece; Milan/Italy; Shanghai/China) were analyzed [mean age 53 ±â€Š10 (SD) years, male individuals 60%, baseline systolic OBP, HBP, and 24 h ABP 144 ±â€Š9, 138 ±â€Š10, and 143 ±â€Š10 mmHg, respectively]. Post-treatment minus pre-treatment systolic CV difference was: OBP: 0.3%, P = 0.28; HBP: -0.2%, P = 0.20; 24 h ABP: 1.1%, P < 0.001. Home and ambulatory (not office) BPV indices presented weak-to-moderate correlation, both before and during treatment (range of coefficients 0.04-0.33). The correlation coefficient between systolic HBP CV and awake ABP CV was 0.21 and 0.28 before and during treatment, respectively (P < 0.05/< 0.001, respectively). Home and ambulatory (not office) BPV indices presented slight to fair agreement (range 64-73%) in detecting participants with high systolic BPV (top quartile of respective distributions) both before and during treatment (kappa range 0.04-0.27). CONCLUSION: These data showed a weak-to-moderate association between out-of-office (but not office) BPV indices both before and during BP-lowering treatment, with reasonable agreement in detecting individuals with high BPV. Out-of-office BP measurements provide more similar and consistent BPV information than office measurements.

3.
Hypertension ; 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38602099

RESUMO

BACKGROUND: Atrial fibrillation (AF) is often asymptomatic and undiagnosed. As AF and hypertension often coexist, opportunistic AF detection during routine automated blood pressure (BP) measurement appears to be an attractive screening method. METHODS: A systematic literature search was conducted to identify studies assessing the diagnostic test accuracy of office, home, or 24-hour ambulatory BP measuring devices with AF detection algorithms versus reference electrocardiography. Analyses were performed per participant (AF status based on several BP readings; most office/home devices) or per reading (AF status based on individual readings; all ambulatory devices). A meta-analysis stratified by device type (office/home/ambulatory) was conducted to calculate pooled measures of diagnostic accuracy. Sensitivity/meta-regression analyses were also performed. RESULTS: Among 3096 records initially retrieved, 23 diagnostic test accuracy studies were included. Data derived from 11 093 individuals (weighted age 69 years, males 56%, hypertensives 79%, diabetics 24%, and AF prevalence 17%) indicated a pooled sensitivity 0.97 (95% CI, 0.92-0.99), specificity 0.93 (95% CI, 0.90-0.95), and accuracy 0.93 (95% CI, 0.89-0.95), with generally consistent results using office, home, or ambulatory BP devices (slightly lower specificity with the latter). The positive and negative predictive values were 0.70 (95% CI, 0.60-0.80) and 0.99 (95% CI, 0.98-1.00), respectively. Sensitivity analyses indicated lower specificity in studies implementing reading versus participant analyses. Most studies presented a low risk of bias and minor applicability concerns. CONCLUSIONS: There is considerable and consistent evidence suggesting high diagnostic accuracy of AF detection algorithms implemented in automated BP monitors during routine BP measurements in and out of the office. AF diagnosis requires verification (electrocardiography) before treatment is administered.

4.
J Hypertens ; 42(6): 939-947, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38647124

RESUMO

Recent evidence suggests that an exaggerated blood pressure (BP) response to standing (ERTS) is associated with an increased risk of adverse outcomes, both in young and old individuals. In addition, ERTS has been shown to be an independent predictor of masked hypertension. In the vast majority of studies reporting on the prognostic value of orthostatic hypertension (OHT), the definition was based only on systolic office BP measurements. This consensus statement provides recommendations on the assessment and management of individuals with ERTS and/or OHT. ERTS is defined as an orthostatic increase in SBP at least 20 mmHg and OHT as an ERTS with standing SBP at least 140 mmHg. This statement recommends a standardized methodology to assess ERTS, by considering body and arm position, and the number and timing of BP measurements. ERTS/OHT should be confirmed in a second visit, to account for its limited reproducibility. The second assessment should evaluate BP changes from the supine to the standing posture. Ambulatory BP monitoring is recommended in most individuals with ERTS/OHT, especially if they have high-normal seated office BP. Implementation of lifestyle changes and close follow-up are recommended in individuals with ERTS/OHT and normotensive seated office BP. Whether antihypertensive treatment should be administered in the latter is unknown. Hypertensive patients with ERTS/OHT should be managed as any other hypertensive patient. Standardized standing BP measurement should be implemented in future epidemiological and interventional studies.


Assuntos
Pressão Sanguínea , Hipertensão , Humanos , Hipertensão/fisiopatologia , Hipertensão/diagnóstico , Hipertensão/terapia , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Consenso , Posição Ortostática , Europa (Continente) , Monitorização Ambulatorial da Pressão Arterial/métodos
5.
Hypertension ; 81(5): 1125-1131, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38506051

RESUMO

BACKGROUND: The prognostic relevance of short-term blood pressure (BP) variability in hypertension is not clearly established. We aimed to evaluate the association of short-term BP variability, with all-cause and cardiovascular mortality in a large cohort of patients with hypertension. METHODS: We selected 59 124 patients from the Spanish Ambulatory Blood Pressure Monitoring Registry from 2004 to 2014 (median follow-up: 9.7 years). Systolic and diastolic BP SD and coefficient of variation from daytime and nighttime, weighted SD, weighted coefficient of variation, average real variability (mean of differences between consecutive readings), and BP variability ratio (ratio between systolic and diastolic 24-hour SD) were calculated through baseline 24-hour ambulatory BP monitoring. Association with all-cause and cardiovascular mortality were assessed by Cox regression models adjusted for clinical confounders and BP. RESULTS: Patients who died during follow-up had higher values of BP variability compared with those remaining alive. In adjusted models systolic and diastolic daytime and weighted SD and coefficient of variation, average real variability, as well as systolic nighttime SD and BP variability ratio were all significantly associated with all-cause and cardiovascular mortality. Hazard ratios for 1-SD increase in the systolic components ranged from 1.05 to 1.12 for all-cause mortality and from 1.07 to 1.17 for cardiovascular mortality. A daytime SD≥13 mm Hg, a nighttime and a weighted SD≥12 mm Hg, and an average real variability ≥10 mm Hg, all systolic, were independently associated with mortality. CONCLUSIONS: Short-term blood pressure variability shows a relatively weak but significant association with all-cause and cardiovascular mortality in patients with hypertension.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Hipertensão , Humanos , Pressão Sanguínea/fisiologia , Prognóstico , Sistema de Registros
7.
J Hypertens ; 42(3): 385-392, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38164947

RESUMO

OBJECTIVES: Ambulatory (ABP) and self-home blood pressure (HBP) measurements are known to be superior to office blood pressure (OBP) measurements in predicting cardiovascular events. Whether ABP has superior prognostic ability than HBP, or the reverse, has not been adequately investigated. METHODS: A systematic literature search was conducted to identify outcome studies investigating HBP and ABP in the same population. A meta-analysis was conducted to calculate the pooled measure of risk regarding the primary endpoint of each study for each method. Primary analysis included the comparison of pooled estimates of HBP versus 24 h ABP. RESULTS: Among 2587 articles retrieved, 6 fulfilled the inclusion criteria. Meta-analysis of five studies ( n  = 4439, weighted age 57 years, men 52%, hypertension 68%, diabetes 15%, cardiovascular disease 11%) indicated pooled hazard ratio per 10 mmHg increase in systolic HBP 1.36 (95% CI 1.23-1.50) and in 24 h ABP 1.38 (1.22-1.57) for the primary endpoint of each study ( z -test P  = NS). Meta-analysis of five studies ( n  = 4497, weighted age 58 years, men 51%, hypertension 65%, diabetes 15%, cardiovascular disease 9%) indicated pooled hazard ratio per 10 mmHg increase in systolic HBP 1.29 (1.14-1.47), daytime ABP 1.30 (1.15-1.46) and nighttime ABP 1.31 (1.14-1.50) ( z -test, P  = NS). Data for DBP were similar. All studies were deemed to have low risk of bias. In studies comparing all the three methods, OBP provided the lowest hazard ratio. CONCLUSION: This meta-analysis of the available prospective outcome studies suggested that HBP and ABP have similar ability in predicting outcome and superior to OBP.


Assuntos
Doenças Cardiovasculares , Diabetes Mellitus , Hipertensão , Masculino , Humanos , Pessoa de Meia-Idade , Monitorização Ambulatorial da Pressão Arterial , Determinação da Pressão Arterial/métodos , Doenças Cardiovasculares/diagnóstico , Prognóstico , Estudos Prospectivos , Hipertensão/diagnóstico , Pressão Sanguínea/fisiologia , Diabetes Mellitus/diagnóstico
8.
Blood Press Monit ; 29(2): 99-102, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37997431

RESUMO

OBJECTIVE: To evaluate the blood pressure (BP) measurement accuracy of the Braun BUA4000 automated oscillometric upper-arm cuff device for self-home use in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2:2018) and its Amendment 1.2020-01. METHODS: Participants were recruited to fulfill the age, sex, BP and limb circumference distribution criteria of the AAMI/ESH/ISO Universal Standard in a general population using the same arm sequential BP measurement method. A single wide-range cuff of the test device was used for arm circumference range 22-42 cm. RESULTS: A total of 98 individuals were recruited and 85 were analyzed [mean age 60.3 ±â€…16.1 (SD) years, 44 men, arm circumference 31.5 ±â€…5.1 cm, range 22-41.5 cm]. For validation criterion 1, the mean difference ± SD between the test device and reference BP readings ( N  = 255) was 0.9 ±â€…6.4/-0.3 ±â€…6.4 mmHg (systolic/diastolic; threshold ≤5 ±â€…8 mmHg). For criterion 2, the SD of the averaged BP differences between the test device and reference BP per individual ( N  = 85) was 5.15/5.81 mmHg (systolic/diastolic; threshold ≤6.88/6.95 mmHg). CONCLUSION: The Braun BUA4000 automated oscillometric BP monitor fulfilled all the requirements of the AAMI/ESH/ISO Universal Standard in a general population and can be recommended for self-monitoring of BP by patients at home.


Assuntos
Monitores de Pressão Arterial , Hipertensão , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Pressão Sanguínea , Hipertensão/diagnóstico , Determinação da Pressão Arterial , Padrões de Referência
9.
Blood Press Monit ; 29(2): 89-92, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37937605

RESUMO

OBJECTIVE: This study evaluated the accuracy of the automated oscillometric upper-arm cuff device AVITA BPM82 intended for home use in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2:2018) and its Amendment 1.2020-01. METHODS: Participants were recruited to fulfill the age, sex, blood pressure (BP), and limb distribution criteria of the AAMI/ESH/ISO Universal Standard and its Amendment 1.2020-01 in a general population using the same arm sequential BP measurement method. Two cuffs of the test device were used for arm circumference 22-33 (medium) and 33-42 cm (large). RESULTS: One-hundred-one individuals were recruited and 85 were analyzed [mean age 57.3 ±â€…15.1 (SD) years, 46 men, arm circumference 32 ±â€…5.1 cm, range 22.3-42 cm]. For validation Criterion 1, the mean difference ±SD between the test device and reference BP readings (N = 255) was 1.3 ±â€…6.5/3.6 ±â€…5.9 mmHg (systolic/diastolic; threshold ≤5 ±â€…8 mmHg). For Criterion 2, the SD of the averaged BP differences between the test device and reference BP per individual (N = 85) was 5.70/5.25 mmHg (systolic/diastolic; threshold ≤6.82/5.89 mmHg). CONCLUSIONS: The automated oscillometric home BP monitor AVITA BPM82 comfortably fulfilled all the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018) and its Amendment 1.2020-01 in a general population and can be recommended for clinical use.


Assuntos
Monitores de Pressão Arterial , Hipertensão , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Pressão Sanguínea , Hipertensão/diagnóstico , Determinação da Pressão Arterial , Padrões de Referência
11.
Hypertens Res ; 47(3): 790-793, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38123713

RESUMO

This study investigated the seasonal effect on blood pressure (BP) variability. Patients on stable antihypertensive drug treatment were assessed with office (OBP), home (HBP), and ambulatory BP (ABP) measurements in winter, next summer, and in next winter. Fifty-eight participants with full data for winter and summer were analyzed (mean age 65.2 ± 7.9 [SD], 64% males). OBP, HBP and ABP (24-h; daytime) were lower in summer than in winter (P < 0.01), whereas nighttime ABP was unchanged (p = NS). Standard deviation (SD), coefficient of variation (CV) and average real variability (ARV) for systolic OBP were higher in winter than summer (p < 0.01/ < 0.05/ < 0.01, respectively). These indices for HBP and ABP measurements did not differ in winter and summer (p = NS). Forty participants had complete data for winter-summer-next winter and HBP/ABP variability indices did not differ for both winters versus summer. These preliminary data suggest that BP variability is unaffected by seasonal changes in contrast to average BP levels.


Assuntos
Determinação da Pressão Arterial , Hipertensão , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Pressão Sanguínea/fisiologia , Estações do Ano , Monitorização Ambulatorial da Pressão Arterial
12.
BMC Med ; 21(1): 442, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37968681

RESUMO

BACKGROUND: Waist-to-height ratio (WHtR) has been proposed as a simple and effective screening tool for assessing central obesity and cardiometabolic risk in both adult and pediatric populations. However, evidence suggests that the use of a uniform WHtR cut-off of 0.50 may not be universally optimal for pediatric populations globally. We aimed to determine the optimal cut-offs of WHtR in children and adolescents with increased cardiometabolic risk across different countries worldwide. METHODS: We used ten population-based cross-sectional data on 24,605 children and adolescents aged 6-18 years from Brazil, China, Greece, Iran, Italy, Korea, South Africa, Spain, the UK, and the USA for establishing optimal WHtR cut-offs. We performed an external independent test (9,619 children and adolescents aged 6-18 years who came from other six countries) to validate the optimal WHtR cut-offs based on the predicting performance for at least two or three cardiometabolic risk factors. RESULTS: Based on receiver operator characteristic curve analyses of various WHtR cut-offs to discriminate those with ≥ 2 cardiometabolic risk factors, the relatively optimal percentile cut-offs of WHtR in the normal weight subsample population in each country did not always coincide with a single fixed percentile, but varied from the 75th to 95th percentiles across the ten countries. However, these relatively optimal percentile values tended to cluster irrespective of sex, metabolic syndrome (MetS) criteria used, and WC measurement position. In general, using ≥ 2 cardiometabolic risk factors as the predictive outcome, the relatively optimal WHtR cut-off was around 0.50 in European and the US youths but was lower, around 0.46, in Asian, African, and South American youths. Secondary analyses that directly tested WHtR values ranging from 0.42 to 0.56 at 0.01 increments largely confirmed the results of the main analyses. In addition, the proposed cut-offs of 0.50 and 0.46 for two specific pediatric populations, respectively, showed a good performance in predicting ≥ 2 or ≥ 3 cardiometabolic risk factors in external independent test populations from six countries (Brazil, China, Germany, Italy, Korea, and the USA). CONCLUSIONS: The proposed international WHtR cut-offs are easy and useful to identify central obesity and cardiometabolic risk in children and adolescents globally, thus allowing international comparison across populations.


Assuntos
Doenças Cardiovasculares , Síndrome Metabólica , Adulto , Humanos , Adolescente , Criança , Obesidade Abdominal/complicações , Obesidade Abdominal/diagnóstico , Estudos Transversais , Obesidade/complicações , Síndrome Metabólica/diagnóstico , Síndrome Metabólica/epidemiologia , Síndrome Metabólica/complicações , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/complicações , Circunferência da Cintura , Índice de Massa Corporal , Razão Cintura-Estatura , Fatores de Risco
14.
Hellenic J Cardiol ; 73: 84-85, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37429505

RESUMO

The optimal diuretic choice [hydrochlorothiazide (HCTZ) or chlorthalidone (CTD)] for the management of hypertension has been an ongoing debate for several years. HCTZ is widely used in the form of single-pill combinations, whereas CTD is a more potent drug vs. HCTZ, especially in reducing nighttime blood pressure (BP), with some indirect evidence suggesting a superiority in terms of cardiovascular (CV) risk reduction. In addition, recent data showed that CTD was safe and effective in terms of BP lowering in predialysis patients with stage 4 chronic kidney disease. The Diuretic Comparison Project was the first head-to-head pragmatic, open-label trial that randomly assigned elderly patients with hypertension under HCTZ therapy to continue with HCTZ or to switch to CTD (equivalent doses). Office BP was similar for both groups throughout the study. The trial showed no difference in major CV events or non-cancer-related deaths during a median follow-up of 2.4 years; yet, CTD was associated with a benefit in participants with a previous myocardial infarction or stroke, which might be a chance finding but could also indicate that a high-risk population is more suitable for revealing the impact of slight differences in the 24-hour BP profile in a relatively short-term follow-up. Interestingly CTD vs. HCTZ was associated with higher hypokalemia rates apart from the latter group of patients where there was no difference. Overall, the available data do not confirm the superiority of CTD over HCTZ in general, but this could be questionable in selected patients.


Assuntos
Doenças Cardiovasculares , Hipertensão , Humanos , Idoso , Clortalidona/uso terapêutico , Clortalidona/farmacologia , Hidroclorotiazida/uso terapêutico , Hidroclorotiazida/farmacologia , Doenças Cardiovasculares/prevenção & controle , Doenças Cardiovasculares/tratamento farmacológico , Anti-Hipertensivos/uso terapêutico , Anti-Hipertensivos/farmacologia , Hipertensão/complicações , Hipertensão/tratamento farmacológico , Diuréticos/uso terapêutico , Pressão Sanguínea , Quimioterapia Combinada
15.
Am Heart J ; 265: 50-58, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37479162

RESUMO

BACKGROUND: Despite high blood pressure being the leading preventable risk factor for death, only 1 in 3 patients achieve target blood pressure control. Key contributors to this problem are clinical inertia and uncertainties in relying on clinic blood pressure measurements to make treatment decisions. METHODS: The NEXTGEN-BP open-label, multicenter, randomized controlled trial will investigate the efficacy, safety, acceptability and cost-effectiveness of a wearable blood pressure monitor-based care strategy for the treatment of hypertension, compared to usual care, in lowering clinic blood pressure over 12 months. NEXTGEN-BP will enroll 600 adults with high blood pressure, treated with 0 to 2 antihypertensive medications. Participants attending primary care practices in Australia will be randomized 1:1 to the intervention of a wearable-based remote care strategy or to usual care. Participants in the intervention arm will undergo continuous blood pressure monitoring using a wrist-wearable cuffless device (Aktiia, Switzerland) and participate in 2 telehealth consultations with their primary care practitioner (general practitioner [GP]) at months 1 and 2. Antihypertensive medication will be up-titrated by the primary care practitioner at the time of telehealth consults should the percentage of daytime blood pressure at target over the past week be <90%, if clinically tolerated. Participants in the usual care arm will have primary care consultations according to usual practice. The primary outcome is the difference between intervention and control in change in clinic systolic blood pressure from baseline to 12 months. Secondary outcomes will be assessed at month 3 and month 12, and include acceptability to patients and practitioners, cost-effectiveness, safety, medication adherence and patient engagement. CONCLUSIONS: NEXTGEN-BP will provide evidence for the effectiveness and safety of a new paradigm of wearable cuffless monitoring in the management of high blood pressure in primary care. TRIAL REGISTRATION: ACTRN12622001583730.


Assuntos
Hipertensão , Dispositivos Eletrônicos Vestíveis , Adulto , Humanos , Pressão Sanguínea/fisiologia , Anti-Hipertensivos/uso terapêutico , Hipertensão/diagnóstico , Hipertensão/tratamento farmacológico , Atenção Primária à Saúde/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
16.
J Hypertens ; 41(9): 1446-1455, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37337866

RESUMO

BACKGROUND: Raised blood pressure (BP) remains the biggest risk factor contributing to the global burden of disease and mortality, despite the COVID-19 pandemic. May Measurement Month (MMM), an annual global screening campaign aims to highlight the importance of BP measurement by evaluating global awareness, treatment and control rates among adults with hypertension. In 2021, we assessed the global burden of these rates during the COVID-19 pandemic. METHODS: Screening sites were set up in 54 countries between May and November 2021 and screenees were recruited by convenience sampling. Three sitting BPs were measured, and a questionnaire completed including demographic, lifestyle and clinical data. Hypertension was defined as a systolic BP at least 140 mmHg and/or a diastolic BP at least 90 mmHg (using the mean of the second and third readings) or taking antihypertensive medication. Multiple imputation was used to impute the average BP when readings were missing. RESULTS: Of the 642 057 screenees, 225 882 (35.2%) were classified as hypertensive, of whom 56.8% were aware, and 50.3% were on antihypertensive medication. Of those on treatment, 53.9% had controlled BP (<140/90 mmHg). Awareness, treatment and control rates were lower than those reported in MMM campaigns before the COVID-19 pandemic. Minimal changes were apparent among those testing positive for, or being vaccinated against COVID-19. Of those on antihypertensive medication, 94.7% reported no change in their treatment because of the COVID-19 pandemic. CONCLUSION: The high yield of untreated or inadequately treated hypertension in MMM 2021 confirms the need for systematic BP screening where it does not currently exist.


Assuntos
COVID-19 , Hipertensão , Adulto , Humanos , Pressão Sanguínea , Anti-Hipertensivos/uso terapêutico , Pandemias , COVID-19/diagnóstico , COVID-19/epidemiologia , Hipertensão/diagnóstico , Hipertensão/tratamento farmacológico , Hipertensão/epidemiologia
17.
J Hypertens ; 41(12): 2074-2087, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37303198

RESUMO

BACKGROUND: There is intense effort to develop cuffless blood pressure (BP) measuring devices, and several are already on the market claiming that they provide accurate measurements. These devices are heterogeneous in measurement principle, intended use, functions, and calibration, and have special accuracy issues requiring different validation than classic cuff BP monitors. To date, there are no generally accepted protocols for their validation to ensure adequate accuracy for clinical use. OBJECTIVE: This statement by the European Society of Hypertension (ESH) Working Group on BP Monitoring and Cardiovascular Variability recommends procedures for validating intermittent cuffless BP devices (providing measurements every >30 sec and usually 30-60 min, or upon user initiation), which are most common. VALIDATION PROCEDURES: Six validation tests are defined for evaluating different aspects of intermittent cuffless devices: static test (absolute BP accuracy); device position test (hydrostatic pressure effect robustness); treatment test (BP decrease accuracy); awake/asleep test (BP change accuracy); exercise test (BP increase accuracy); and recalibration test (cuff calibration stability over time). Not all these tests are required for a given device. The necessary tests depend on whether the device requires individual user calibration, measures automatically or manually, and takes measurements in more than one position. CONCLUSION: The validation of cuffless BP devices is complex and needs to be tailored according to their functions and calibration. These ESH recommendations present specific, clinically meaningful, and pragmatic validation procedures for different types of intermittent cuffless devices to ensure that only accurate devices will be used in the evaluation and management of hypertension.


Assuntos
Determinação da Pressão Arterial , Hipertensão , Humanos , Pressão Sanguínea/fisiologia , Hipertensão/diagnóstico , Esfigmomanômetros , Monitores de Pressão Arterial
18.
J Hypertens ; 41(12): 2088-2094, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37303225

RESUMO

OBJECTIVE: To develop scientific consensus recommendations for the optimal design and functions of different types of blood pressure (BP) measuring devices used in clinical practice for the detection, management, and long-term follow-up of hypertension. METHODS: A scientific consensus meeting was performed by the European Society of Hypertension (ESH) Working Group on BP Monitoring and Cardiovascular Variability and STRIDE BP (Science and Technology for Regional Innovation and Development in Europe) during the 2022 Scientific Meeting of the ESH in Athens, Greece. Manufacturers were also invited to provide their feedback on BP device design and development. Thirty-one international experts in clinical hypertension and BP monitoring contributed to the development of consensus recommendations on the optimal design of BP devices. STATEMENT: International consensus was reached on the requirements for the design and features of five types of BP monitors, including office (or clinic) BP monitors, ambulatory BP monitors, home BP monitors, home BP telemonitors, and kiosk BP monitors for public spaces. For each device type "essential" requirements (must have), and "optional" ones (may have) are presented, as well as additional comments on the optimal device design and features. CONCLUSIONS: These consensus recommendations aim at providing manufacturers of BP devices with the requirements that are considered mandatory, or optional, by clinical experts involved in the detection and management of hypertension. They are also directed to administrative healthcare personnel involved in the provision and purchase of BP devices so that they can recommend the most appropriate ones.


Assuntos
Determinação da Pressão Arterial , Hipertensão , Humanos , Pressão Sanguínea , Reprodutibilidade dos Testes , Hipertensão/diagnóstico , Hipertensão/terapia , Esfigmomanômetros , Monitorização Ambulatorial da Pressão Arterial
20.
J Hypertens ; 41(6): 1003-1010, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37016925

RESUMO

OBJECTIVES: Cuffless wearable blood pressure (BP) devices may allow detailed evaluation of BP for prolonged periods, but their ability to accurately track BP changes is uncertain. We investigated whether a commercially available cuffless wearable device tracks: 24-h systolic (SBP) and diastolic BP (DBP) compared to conventional ambulatory monitoring (ABPM); and antihypertensive medication-induced BP changes compared to cuff-based home BP monitoring (HBPM). METHODS: We fitted 41 participants (32% females, 58 ±â€Š14 years, 80% hypertensive) with a wrist-wearable cuffless BP device (Aktiia) continuously for 6-12 days. At the beginning and the end of this period, 24-h ABPM was performed. Three participants with hypertension (one female; 60 ±â€Š8 years) wore the Aktiia device and performed HBPM continuously one week before and 2 weeks after antihypertensive medication uptitration. RESULTS: Compared to ABPM, Aktiia reported higher average SBP for 24-h (difference 4.9 mmHg, 95% CI [1.9, 7.9]) and night-time (15.5[11.8, 19.1] mmHg; all P ≤ 0.01), but similar daytime (1.0 [-1.8, 3.8] mmHg; P = 0.48). Similarly, average cuffless DBP was higher for 24-h (4.2 [2.3, 6.0] mmHg) and night-time (11.8 [9.5, 14.1] mmHg; both P  < 0.001), but similar during daytime (1.4 [-0.4, 3.23] mmHg; P  = 0.13). Aktiia also reported reduced night-time dip for SBP (difference 14.2 [12.1, 16.3] mmHg) and DBP (10.2 [8.5, 11.9] mmHg; both P  < 0.001). The average medication-induced SBP/DBP decline after 2 weeks of uptitration was -1.0/-0.8 mmHg with Aktiia vs. -19.7/-11.5 mmHg with HBPM ( P  = 0.03 for difference). CONCLUSION: This cuffless wearable device did not accurately track night-time BP decline and results suggested it was unable to track medication-induced BP changes.


Assuntos
Hipertensão , Dispositivos Eletrônicos Vestíveis , Humanos , Feminino , Masculino , Pressão Sanguínea/fisiologia , Anti-Hipertensivos/uso terapêutico , Anti-Hipertensivos/farmacologia , Determinação da Pressão Arterial/métodos , Hipertensão/diagnóstico , Hipertensão/tratamento farmacológico , Monitorização Ambulatorial da Pressão Arterial