Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Philos Trans A Math Phys Eng Sci ; 367(1896): 2293-310, 2009 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-19414456

RESUMO

Many simulation studies in biomedicine are based on a similar sequence of processing steps, starting from images and running through geometric model generation, assignment of tissue properties, numerical simulation and visualization of the results--a process known as image-based geometric modelling and simulation. We present an overview of software systems for implementing such a sequence both within highly integrated problem-solving environments and in the form of loosely integrated pipelines. Loose integration in this case indicates that individual programs function largely independently but communicate through files of a common format and support simple scripting, so as to automate multiple executions wherever possible. We then describe three specific applications of such pipelines to translational biomedical research in electrophysiology.


Assuntos
Simulação por Computador , Eletrofisiologia , Software , Diagnóstico por Imagem
2.
Conf Proc IEEE Eng Med Biol Soc ; 2006: 2554-7, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17946964

RESUMO

Computational modeling and simulation can provide important insights into the electrical and electrophysiological properties of cells, tissues, and organs. Commonly, the modeling is based on Maxwell's and Poisson's equations for electromagnetic and electric fields, respectively, and numerical techniques are applied for field calculation such as the finite element and finite differences methods. Focus of this work are finite element methods, which are based on an element-wise discretization of the spatial domain. These methods can be classified on the element's geometry, e.g. triangles, tetrahedrons and hexahedrons, and the underlying interpolation functions, e.g. polynomials of various order. Aim of this work is to describe finite element-based approaches and their application to extend the problem-solving environment SCIRun/BioPSE. Finite elements of various types were integrated and methods for interpolation and integration were implemented. General methods for creation of finite element system matrices and boundary conditions were incorporated. The extension provides flexible means for geometric modeling, physical simulation, and visualization with particular application in solving bioelectric field problems.


Assuntos
Potenciais de Ação/fisiologia , Mapeamento Potencial de Superfície Corporal/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiologia , Modelos Cardiovasculares , Radiometria/métodos , Software , Algoritmos , Animais , Simulação por Computador , Campos Eletromagnéticos , Análise de Elementos Finitos , Humanos , Potenciais da Membrana/fisiologia , Doses de Radiação , Design de Software
3.
Med Biol Eng Comput ; 43(6): 776-82, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16594306

RESUMO

The results of a geometric model of cardiac tissue, used to compute the bidomain conductivity tensors during three phases of ischaemia, are described. Ischaemic conditions were simulated by model parameters being changed to match the morphological and electrical changes of three phases of ischaemia reported in literature. The simulated changes included collapse of the interstitial space, cell swelling and the closure of gap junctions. The model contained 64 myocytes described by 2 million tetrahedral elements, to which an external electric field was applied, and then the finite element method was used to compute the associated current density. In the first case, a reduction in the amount of interstitial space led to a reduction in extracellular longitudinal conductivity by about 20%, which is in the range of reported literature values. Moderate cell swelling in the order of 10-20% did not affect extracellular conductivity considerably. To match the reported drop in total tissue conductance reported in experimental studies during the third phase of ischaemia, a ten fold increase in the gap junction resistance was simulated. This ten-fold increase correlates well with the reported changes in gap junction densities in the literature.


Assuntos
Sistema de Condução Cardíaco/fisiopatologia , Modelos Cardiovasculares , Isquemia Miocárdica/fisiopatologia , Condutividade Elétrica , Junções Comunicantes/fisiologia , Humanos , Miócitos Cardíacos/fisiologia
4.
Arch Physiol Biochem ; 110(3): 165-76, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12221516

RESUMO

Both fetal electrocardiography and fetal magnetocardiography are influenced by the volume conduction within the abdomen of the pregnant woman. In this paper, various models are used to simulate this influence. Such models are helpful to determine where to attach electrodes at the maternal abdomen in case fetal ECGs are measured and where to position the magnetocardiograph in case fetal MCGs are measured. Another goal is to assess the influence of individual differences, such as the amount of amniotic fluid. Seven models based on MR-images have been created, four for the third trimester of gestation, with the fetus in left occiput position, and three for the second trimester. The models consist of four compartments; the fetus, the vernix caseosa, the amniotic fluid, and the remainder of the maternal abdomen. It turns out that individual differences have a large impact on the fetal MCG and that the best measurement positions are expected over the centre of the abdomen near the fetal heart. The fetal ECG is dependent on the vernix caseosa and when this layer is present, the fetal ECG is best measured by two electrodes, one over the fetal mouth and the other over the bottom of the fetus.


Assuntos
Abdome/embriologia , Ecocardiografia/métodos , Doenças Fetais/diagnóstico , Ultrassonografia Pré-Natal/métodos , Fenômenos Eletromagnéticos , Feminino , Humanos , Modelos Anatômicos , Gravidez
5.
Ultrasound Obstet Gynecol ; 20(2): 142-53, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12153665

RESUMO

OBJECTIVES: To test the usefulness and reliability of fetal magnetocardiography as a diagnostic or screening tool, both for fetuses with arrhythmias as well as for fetuses with a congenital heart defect. METHODS: We describe 21 women with either a fetal arrhythmia or a congenital heart defect discovered during prenatal evaluation by sonography. Four fetuses showed a complete atrioventricular block, two an atrial flutter, nine ventricular extrasystole, and one a complete irregular heart rate. Five fetuses were suspected to have a congenital heart defect. In all cases magnetocardiograms were recorded. RESULTS: Nine fetuses with extrasystole showed a range of premature atrial contractions, premature junctional beats or premature ventricular contractions. Two fetuses with atrial flutter showed typical flutter waves and four fetuses with complete atrioventricular block showed an uncoupling of P-wave and QRS complex. One fetus showed a pattern suggestive of a bundle branch block. In three of four fetuses with confirmed congenital heart defects the magnetocardiogram showed abnormalities. CONCLUSION: Fetal magnetocardiography allows an insight into the electrophysiological aspects of the fetal heart, is accurate in the classification of fetal arrhythmias, and shows potential as a tool in defining a population at risk for congenital heart defects.


Assuntos
Técnicas Eletrofisiológicas Cardíacas , Doenças Fetais/diagnóstico , Cardiopatias Congênitas/diagnóstico , Testes de Função Cardíaca/métodos , Diagnóstico Pré-Natal/métodos , Adulto , Complexos Cardíacos Prematuros/diagnóstico , Complexos Cardíacos Prematuros/diagnóstico por imagem , Complexos Cardíacos Prematuros/fisiopatologia , Fenômenos Eletromagnéticos , Feminino , Doenças Fetais/fisiopatologia , Bloqueio Cardíaco/diagnóstico , Bloqueio Cardíaco/diagnóstico por imagem , Bloqueio Cardíaco/fisiopatologia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Humanos , Gravidez , Reprodutibilidade dos Testes , Ultrassonografia Pré-Natal
6.
Bioelectrochemistry ; 53(2): 155-60, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11339301

RESUMO

The electrical conductivity of human tissue at low frequencies is discussed when a uniform electric field is applied to some tissue containing many cells. Human tissue is described as a suspension of particles in a conducting solution. Relations are derived for the apparent conductivity of a cell surrounded by a membrane. These relations can be used to estimate the accuracy of a model that considers the cell as a non-conducting particle. Usually, a tissue is composed of several types of particles. A relationship that expresses the effective conductivity of a suspension of one type of ellipsoidal particles could be found in the literature. The orientation of the particles could be uniform or they could be randomly distributed. For non-conducting particles, this expression is known as Archie's law. The expression is extended such that also the effective conductivity of a suspension of various types of particles can be calculated. The result is evaluated for the cortex of the brain using experimental data given in the literature.


Assuntos
Córtex Cerebral/fisiologia , Condutividade Elétrica , Córtex Cerebral/citologia , Humanos , Soluções
7.
Med Biol Eng Comput ; 36(6): 711-6, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10367461

RESUMO

The influence of the volume conductor on the EEG, MEG, fetal ECG and fetal MCG is studied by means of simulations. The assumption that the Maxwell equations can be used in a quasi-static approximation is reconsidered and the fact that the conductivity of human tissue is frequency dependent is taken into account. It is found that displacement currents have a substantial effect on the fetal ECG and to a lesser degree on the fetal MCG. Moreover, the frequency dependence of the conductivity of the tissues within the head may have a considerable effect on the EEG.


Assuntos
Eletrocardiografia , Eletroencefalografia , Eletrofisiologia , Monitorização Fetal , Humanos , Magnetoencefalografia , Modelos Biológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...