Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Radiology ; 267(1): 293-304, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23297320

RESUMO

PURPOSE: To evaluate diagnostic performance of three nonenhanced methods: variable-refocusing-flip angle (FA) fast spin-echo (SE)-based magnetic resonance (MR) angiography (variable FA MR) and constant-refocusing-FA fast SE-based MR angiography (constant-FA MR) and flow-sensitive dephasing (FSD)-prepared steady-state free precession MR angiography (FSD MR) for calf arteries, with dual-injection three-station contrast material-enhanced MR angiography (gadolinium-enhanced MR) as reference. MATERIALS AND METHODS: This prospective study was institutional review board approved and HIPAA compliant, with informed consent. Twenty-one patients (13 men, eight women; mean age, 62.6 years) underwent calf-station variable-FA MR, constant-FA MR, and FSD MR at 1.5 T, with gadolinium-enhanced MR as reference. Image quality and stenosis severity were assessed in 13 segments per leg by two radiologists blinded to clinical data. Combined constant-FA MR and FSD MR reading was also performed. Methods were compared (logistic regression for correlated data) for diagnostic accuracy. RESULTS: Of 546 arterial segments, 148 (27.1%) had a hemodynamically significant (≥ 50%) stenosis. Image quality was satisfactory for all nonenhanced MR sequences. FSD MR was significantly superior to both other sequences (P < .0001), with 5-cm smaller field of view; 9.6% variable-FA MR, 9.6% constant-FA MR, and 0% FSD MR segmental evaluations had nondiagnostic image quality scores, mainly from high diastolic flow (variable-FA MR) and motion artifact (constant-FA MR). Stenosis sensitivity and specificity were highest for FSD MR (80.3% and 81.7%, respectively), compared with those for constant-FA MR (72.3%, P = .086; and 81.8%, P = .96) and variable-FA MR (75.9%, P = .54; and 75.6%, P = .22). Combined constant-FA MR and FSD MR had superior sensitivity (81.8%) and specificity (88.3%) compared with constant-FA MR (P = .0076), variable-FA MR (P = .0044), and FSD MR (P = .0013). All sequences had an excellent negative predictive value (NPV): 93.2%, constant-FA MR; 94.7%, variable-FA MR; 91.7%, FSD MR; and 92.9%, combined constant-FA MR and FSD MR. CONCLUSION: At 1.5 T, all evaluated nonenhanced MR angiographic methods demonstrated satisfactory image quality and excellent NPV for hemodynamically significant stenosis. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120859/-/DC1.


Assuntos
Perna (Membro)/irrigação sanguínea , Angiografia por Ressonância Magnética/métodos , Doenças Vasculares Periféricas/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Técnica de Subtração
2.
Invest Radiol ; 47(12): 717-24, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23070094

RESUMO

OBJECTIVE: The purpose of this study was to monitor iron clearance from the liver by means of T2 and T2* mapping after administration of an ultrasmall superparamagnetic iron oxide (USPIO) agent. MATERIALS AND METHODS: The study was performed using ferumoxytol (Feraheme), a USPIO agent that has been approved by the US Food and Drug Administration for the treatment of iron deficiency anemia in adult patients with chronic kidney disease. Six healthy human participants without anemia or preexisting iron overload were prospectively included. The cohort comprised 4 men and 2 postmenopausal women, aged 22 to 57 years. T2 and T2* mapping of the liver were performed at 1.5 T using multiple spin echo and multiple gradient echo sequences, respectively. After baseline imaging, ferumoxytol was injected intravenously at a dose of 5 mg Fe/kg body weight. Imaging was repeated at 3 days, 1 month, and every 2 months thereafter for up to 11 months or until liver T2* had recovered to 24 milliseconds, the threshold used to define iron deposition. For each examination, maps of the relaxation rates R2 (= 1/T2) and R2* (= 1/T2*) were generated by fitting the signal intensity data as a function of echo time to a monoexponential decay. RESULTS: No adverse reactions to ferumoxytol injection occurred. The magnetic resonance (MR) responses to ferumoxytol varied widely among the participants. Liver R2* increased from a mean value of 35.6 s (range, 28.7-40.9 s) at baseline to a mean value of 241 s (range, 161-417 s) 3 days after administration. Liver R2 increased from 19.4 s (range, 16.6-23.8 s) at baseline to 45.3 s (range, 34.4-58.5 s) at 3 days. There was also a large variation in iron clearance times. In 1 participant, MR relaxation rates had recovered to baseline by 3 months, whereas, in 3 participants, liver R2* remained elevated at 11 months (R2* > 55 s, ie, T2* < 18 milliseconds). In these 3 participants, liver R2 also remained marginally higher at 11 months than corresponding baseline values. CONCLUSIONS: Iron deposition in the liver after a 5 mg Fe/kg dose of ferumoxytol may alter signal contrast on MR images for several months after administration. This is an important consideration in the use of USPIO agents for diagnostic purposes.


Assuntos
Meios de Contraste , Dextranos , Ferro/farmacocinética , Fígado/metabolismo , Imageamento por Ressonância Magnética , Nanopartículas de Magnetita , Adulto , Feminino , Humanos , Masculino , Taxa de Depuração Metabólica , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
3.
J Magn Reson Imaging ; 34(6): 1472-9, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21959828

RESUMO

PURPOSE: To investigate arterial flow characteristics in the setting of vascular disease, and examine their effect on the performance of fast spin-echo (FSE)-based noncontrast MR angiography (NC-MRA). MATERIALS AND METHODS: Seventeen patients were recruited from among those scheduled for routine contrast-enhanced MR angiography (CE-MRA) of the lower extremities at 1.5 Tesla. The research portion of the exam was performed before the clinically-indicated protocol and included phase-contrast imaging at multiple levels in the legs and FSE-based NC-MRA in the calf and thigh, using a three-dimensional ECG-gated technique that exploits differences in arterial flow velocity between diastole and systole. RESULTS: Vascular occlusions were associated with reduced systolic velocity, a delayed systolic peak, and, in two middle-aged patients, an increase in diastolic velocity. Elevated systolic and diastolic velocities were observed in a subject with a nonhealing ulcer. NC-MRA allowed visualization of arteries with systolic velocities as low as 3 cm/s, and exhibited comparable depiction to CE-MRA for diastolic velocities as high as 6 cm/s. At the highest diastolic velocities observed (15 cm/s) arterial depiction was severely degraded. CONCLUSION: FSE-based NC-MRA as presently implemented performs successfully over a wide range of flow patterns, but does not accommodate extremely low systolic velocities or very high diastolic velocities.


Assuntos
Artérias/fisiopatologia , Angiografia por Ressonância Magnética/métodos , Doenças Vasculares/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artérias/patologia , Velocidade do Fluxo Sanguíneo , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sístole
4.
Radiology ; 260(3): 781-9, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21771953

RESUMO

PURPOSE: To assess prospectively the ability of quantitative low-dose three-dimensional magnetic resonance (MR) renography to help identify the cause of acute graft dysfunction. MATERIALS AND METHODS: This HIPAA-compliant study was approved by the institutional review board, and written informed consent was obtained. Between December 2001 and May 2009, sixty patients with transplanted kidneys (41 men and 19 women; mean age, 49 years; age range, 22-71 years) were included. Thirty-one patients had normal function and 29 had acute dysfunction due to acute rejection (n = 12), acute tubular necrosis (ATN) (n = 8), chronic rejection (n = 6), or drug toxicity (n = 3). MR renography was performed at 1.5 T with three-dimensional gradient-echo imaging. With use of a multicompartment renal model, the glomerular filtration rate (GFR) and the mean transit time (MTT) of the tracer for the vascular compartment (MTT(A)), the tubular compartment (MTT(T)), and the collecting system compartment (MTT(C)) were calculated. Also derived was MTT for the whole kidney (MTT(K) = MTT(A) + MTT(T) + MTT(C)) and fractional MTT of each compartment (MTT(A/K) = MTT(A)/MTT(K), MTT(T/K) = MTT(T)/MTT(K), MTT(C/K) = MTT(C)/MTT(K)). These parameters were compared in patients in the different study groups. Statistical analysis was performed by using analysis of covariance. RESULTS: There were significant differences in GFR and MTT(K) between the acute dysfunction group (36.4 mL/min ± 20.8 [standard deviation] and 177.1 seconds ± 46.8, respectively) and the normal function group (65.9 mL/min ± 27.6 and 140.5 seconds ± 51.8, respectively) (P < .001 and P = .004). The MTT(A/K) was significantly higher in the acute rejection group (mean, 12.7% ± 2.9) than in the normal function group (mean, 8.3% ± 2.2; P < .001) or in the ATN group (mean, 7.1% ± 1.4; P < .001). The MTT(T/K) was significantly higher in the ATN group (mean, 83.2% ± 9.2) than in the normal function group (mean, 72.4% ± 10.2; P = .031) or in the acute rejection group (mean, 69.2% ± 6.1; P = .003). CONCLUSION: Low-dose MR renography analyzed by using a multicompartmental tracer kinetic renal model may help to differentiate noninvasively between acute rejection and ATN after kidney transplantation.


Assuntos
Injúria Renal Aguda/etiologia , Injúria Renal Aguda/patologia , Imageamento Tridimensional/métodos , Transplante de Rim/efeitos adversos , Transplante de Rim/patologia , Imageamento por Ressonância Magnética/métodos , Renografia por Radioisótopo/métodos , Adulto , Idoso , Humanos , Técnicas In Vitro , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Falha de Tratamento , Adulto Jovem
5.
Radiology ; 252(3): 874-81, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19567653

RESUMO

After institutional review board approval and informed consent were obtained for this HIPAA-compliant investigation, a three-dimensional electrocardiographically gated variable flip angle (VFA) fast spin-echo magnetic resonance (MR) angiography technique was evaluated as an unenhanced method for imaging hand arteries in 13 subjects (including four patients) at 3.0 T; this included evaluation of vessel visualization with warming and cooling in seven subjects. Examinations were evaluated for image quality and vessel conspicuity. Clear separation of arteries from veins was achieved in all subjects, with excellent vessel conspicuity and depiction of stenoses. Warming improved vessel visualization in healthy volunteers. VFA MR angiography is a high-spatial-resolution technique that enables the assessment of vascular reactivity in response to temperature challenge.


Assuntos
Eletrocardiografia , Mãos/irrigação sanguínea , Imageamento Tridimensional , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Temperatura Baixa , Feminino , Frequência Cardíaca/fisiologia , Temperatura Alta , Humanos , Processamento de Imagem Assistida por Computador , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doença de Raynaud/fisiopatologia , Esclerodermia Limitada/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA