Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Clin Chem Lab Med ; 50(9): 1635-40, 2012 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-22962225

RESUMO

BACKGROUND: Low plasma betaine concentrations are a feature of seriously ill patients. Increased dietary betaine intake has been associated with lowered systemic inflammation. We aimed to compare plasma cortisol (a stress marker) and C-reactive protein (an inflammation marker) as statistical predictors of plasma betaine concentrations. METHODS: Plasma carnitine, cortisol and C-reactive protein concentrations, other biochemical measures and urine betaine excretion, were compared with plasma betaine concentration by correlation and in multiple regression models, using morning blood and urine samples from 64 ambulant elderly subjects and from 55 patients admitted to hospital with hip fractures. RESULTS: In the ambulant elderly without acute trauma, plasma cortisol (with negative coefficients) and carnitine (with positive coefficients) statistically predicted plasma betaine concentrations. C-reactive protein was not a predictor. In the patients, the significant predictors were plasma carnitine (positive coefficient) and plasma homocysteine (negative coefficient) and C-reactive protein again was not a predictor. In regression models using combined patient and control data there were large ranges of both cortisol and especially C-reactive protein; cortisol and homocysteine (negative coefficients) and carnitine (positive coefficient) were significant predictors but C-reactive protein was not significant. CONCLUSIONS: Stress rather than inflammation may affect plasma betaine concentrations.


Assuntos
Betaína/sangue , Proteína C-Reativa/análise , Hidrocortisona/sangue , Idoso , Idoso de 80 Anos ou mais , Carnitina/sangue , Feminino , Fraturas do Quadril/sangue , Homocisteína/sangue , Humanos , Masculino , Análise de Regressão
3.
J Microbiol Methods ; 87(1): 111-3, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21741416

RESUMO

Selected ion flow tube-mass spectrometry has been used to measure the volatile compounds occurring in the headspace of urine samples inoculated with common urinary tract infection (UTI)-causing microbes Escherichia coli, Proteus vulgaris, Pseudomonas aeruginosa, Staphylococcus aureus, Staphylococcus epidermidis, Klebsiella pneumoniae, Enterococcus faecalis, or Candida albicans. This technique has the potential to offer rapid and simple diagnosis of the causative agent of UTIs.


Assuntos
Técnicas de Tipagem Bacteriana/métodos , Meios de Cultura/química , Espectrometria de Massas , Técnicas de Tipagem Micológica/métodos , Urina/química , Compostos Orgânicos Voláteis/urina , Candida albicans/classificação , Candida albicans/crescimento & desenvolvimento , Candida albicans/metabolismo , Enterococcus faecalis/classificação , Enterococcus faecalis/crescimento & desenvolvimento , Enterococcus faecalis/metabolismo , Escherichia coli/classificação , Escherichia coli/crescimento & desenvolvimento , Escherichia coli/metabolismo , Humanos , Klebsiella pneumoniae/classificação , Klebsiella pneumoniae/crescimento & desenvolvimento , Klebsiella pneumoniae/metabolismo , Masculino , Proteus vulgaris/classificação , Proteus vulgaris/crescimento & desenvolvimento , Proteus vulgaris/metabolismo , Pseudomonas aeruginosa/classificação , Pseudomonas aeruginosa/crescimento & desenvolvimento , Pseudomonas aeruginosa/metabolismo , Staphylococcus aureus/classificação , Staphylococcus aureus/crescimento & desenvolvimento , Staphylococcus aureus/metabolismo , Staphylococcus epidermidis/classificação , Staphylococcus epidermidis/crescimento & desenvolvimento , Staphylococcus epidermidis/metabolismo , Infecções Urinárias/diagnóstico , Infecções Urinárias/microbiologia , Urina/microbiologia
4.
J Breath Res ; 5(3): 037105, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21654020

RESUMO

The haloamines, including the chloramines (H(2)NCl, HNCl(2)) and bromamine (H(2)NBr), are diffusible gases that are likely to be produced during inflammation and so may be present as markers of lung inflammation on breath. Although haloamines are quite reactive, it is possible to measure these compounds in humid samples using SIFT-MS. Until recently the quantification of haloamines in breath suffered from interference from other common breath compounds. This was overcome by heating the flow tube which removed major water cluster product ions. Despite the improvements to the method, previous attempts to measure the haloamines in breath samples from normal volunteers had found no evidence to support their presence. Since it is proposed that the haloamines may be present in higher concentrations during airways inflammation we have attempted to detect the compounds in the exhaled breath of patients with airways inflammatory conditions. On-line and off-line breath samples were analyzed; however, there was no discernable change to any of product ions when compared to ambient air or normal subjects. This suggests that despite sensitivity in the mid part per trillion range haloamines are not significantly raised in airways inflammation.


Assuntos
Biomarcadores/análise , Testes Respiratórios/métodos , Brometos/análise , Cloraminas/análise , Doenças Respiratórias/diagnóstico , Expiração , Humanos , Espectrometria de Massas , Valores de Referência , Doenças Respiratórias/metabolismo , Sensibilidade e Especificidade
5.
Comput Methods Programs Biomed ; 101(2): 173-82, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20728235

RESUMO

This paper compares three methods for estimating renal function, as tested in rats. Acute renal failure (ARF) was induced via a 60-min bilateral renal artery clamp in 8 Sprague-Dawley rats and renal function was monitored for 1 week post-surgery. A two-compartment model was developed for estimating glomerular filtration via a bolus injection of a radio-labelled inulin tracer, and was compared with an estimated creatinine clearance method, modified using the Cockcroft-Gault equation for rats. These two methods were compared with selected ion flow tube-mass spectrometry (SIFT-MS) monitoring of breath analytes. Determination of renal function via SIFT-MS is desirable since results are available non-invasively and in real time. Relative decreases in renal function show very good correlation between all 3 methods (R²=0.84, 0.91 and 0.72 for breath-inulin, inulin-creatinine, and breath-creatinine correlations, respectively), and indicate good promise for fast, non-invasive determination of renal function via breath testing.


Assuntos
Injúria Renal Aguda/fisiopatologia , Biomarcadores/análise , Modelos Teóricos , Animais , Taxa de Filtração Glomerular , Espectrometria de Massas , Ratos
6.
Rapid Commun Mass Spectrom ; 24(12): 1744-8, 2010 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-20499318

RESUMO

The selectivity and sensitivity of selected ion flow tube mass spectrometry (SIFT-MS) for individual breath analysis of haloamines has been improved by heating the flow tube in a commercial instrument to around 106 degrees C. Data is presented showing the marked reduction in the number density of water clusters of product ions of common breath metabolites that are isobaric with the product ions from monochloramine and monobromamine that are used to monitor the haloamine concentrations. These results have direct relevance to the real-time monitoring of chloramines in drinking water, swimming pools and food processing plants. However, once the isobaric overlaps from water cluster ions are reduced at the higher temperatures, there is no conclusive evidence showing the presence of haloamines on single breath exhalations in the mid parts per trillion range from examination of the breaths of volunteers.


Assuntos
Brometos/análise , Cloraminas/análise , Monitoramento Ambiental/métodos , Espectrometria de Massas/métodos , Monitoramento Ambiental/instrumentação , Umidade , Espectrometria de Massas/instrumentação
7.
J Breath Res ; 4(4): 046001, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21383484

RESUMO

Using selected ion flow tube-mass spectrometry (SIFT-MS) for on-line analysis, we aimed to define the optimal single-exhalation breathing manoeuvre from which a measure of expired acetone concentration could be obtained. Using known acetone concentrations in vitro, we determined the instrument's accuracy, inter-measurement variability and dynamic response time. Further, we determined the effects of expiratory flow and volume on acetone concentration in the breath of 12 volunteers and calculated intra-individual coefficients of variation (CVs). At acetone concentrations of 600-3000 ppb on 30 days over 2 months there was an instrument measurement bias of 8% that did not change over time, inter-day and intra-day CVs were 5.6% and 0.0%, respectively, and the 10-90% response time was 500 ± 50 ms (mean ± SE). Acetone concentrations at exhalation flows of 193 ± 18 (mean ± SD) and 313 ± 32 ml s(-1) were 619 ± 1.83 (geometric mean ± logSD) and 618 ± 1.82 ppb in the fraction 70-85% by volume of exhaled vital capacity (V(70-85%)) and 636 ± 1.82 (geometric mean ± logSD) and 631 ± 1.83 ppb in V(85-100%). A difference was observed between acetone concentrations in the V(70-85%) and V(85-100%) fractions (p < 0.01), but flow had no effect. Median intra-individual CVs were 1.6-2.6%. On-line SIFT-MS measurement of acetone concentration in a single exhalation requires control of exhaled volume but not flow, and yields low intra-individual CVs and is potentially useful in approximating blood glucose and monitoring metabolic stress.


Assuntos
Acetona/metabolismo , Testes Respiratórios , Expiração , Espectrometria de Massas/métodos , Adulto , Feminino , Humanos , Masculino , Óxido Nítrico/química , Reprodutibilidade dos Testes , Capacidade Vital
8.
J Breath Res ; 3(1): 016001, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21383449

RESUMO

The measurement of volatile organic compounds in exhaled breath is becoming recognized as a method of disease diagnosis and therapeutic monitoring. The aim of this study was to validate the collection of breath from intubated patients in the intensive care setting. This was done by assembling a system of ventilators and humidification to emulate the human respiratory system. A known concentration of acetone was spiked into the system to simulate alveolar and dead-space 'breath'. Selected-ion flow tube mass spectrometry (SIFT-MS) was used to directly measure gas at two separate points (headspace, distal circuit end) and from Tedlar bags collected using a remote breath fractionator. The mean acetone concentration for headspace, distal circuit end and Tedlar bag concentrations were calculated. The fractionator was effective in separating the early (dead space) and late phases of exhaled breath. Results from the late Tedlar bag samples collected by the remote breath fractionator showed a clear correlation with headspace and distal circuit end acetone concentrations. The collection for remote analysis of breath samples from immobile patients is made possible using the breath fractionator in conjunction with SIFT-MS analysis.

9.
J Chromatogr A ; 1104(1-2): 263-71, 2006 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-16376895

RESUMO

Cationic aracyl esters of betaines can be formed by alkylation with aracyl halides or trifluoromethanesulfonates. HPLC on a non-endcapped strong cation exchange (SCX) column gave high retention of these derivatives. Cation exchange HPLC may be carried out on a normal-phase (silica or alumina) column using a polar organic solvent (acetonitrile, propan-2-ol) containing an aqueous buffer with an organic cation and a hydrophilic anion. Selectivity is affected by the choice of organic solvent and buffer, e.g. alcohols decrease the retention times of hydroxybetaines such as carnitine. Retention is reduced by increasing the water content and the buffer concentration. Capillary electrophoresis migration times are affected by the choice of buffer anion, with low pH citrate buffers favoured.


Assuntos
Betaína/isolamento & purificação , Betaína/química , Resinas de Troca de Cátion , Cátions , Cromatografia Líquida de Alta Pressão , Eletroforese Capilar , Padrões de Referência , Solventes
10.
Clin Chim Acta ; 365(1-2): 264-9, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16257400

RESUMO

BACKGROUND: Methylamines have many metabolic roles and there is an increasing demand for their measurement. Glycine betaine is an important osmolyte, and a reservoir for methyl groups. Proline betaine and trigonelline are important dietary betaines. Trimethylamine, derived from gut flora, is normally converted to trimethylamine oxide but in 'fish odour syndrome' is excreted as TMA. These compounds are all suitable for quantification by (1)H NMR spectroscopy as they all have methyl protons. METHOD: Urine samples are acidified and (1)H NMR spectra are obtained using presaturation for water suppression. Peak integrals or heights are compared to an internal standard of acetonitrile. RESULTS: Inter- and intra-assay CV's were <5% for TMAO and creatinine, and <10% for the other analytes. Responses were linear from 50 to 1000 microM for all metabolites, and recoveries were > or =97%. Limits of detection using NMR are slightly higher than alternative HPLC assays (15-25 microM). However, sensitivity is adequate for the detection of raised levels in urine, and sample analysis was complete in less than 5 min. CONCLUSION: (1)H NMR spectroscopy is a convenient, rapid and economical option for the determination of betaines and related compounds in urine in a single analysis.


Assuntos
Espectroscopia de Ressonância Magnética/métodos , Metilaminas/urina , Humanos , Prótons , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Clin Chim Acta ; 360(1-2): 60-6, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15961070

RESUMO

BACKGROUND: We have devised a simple assay to detect adequate biotin intake, which uses an alternative configuration from most existing assays. METHODS: The assay depends on the competition of streptavidin peroxidase for immobilized biotin or soluble biotin in standards or samples. Immobilized streptavidin peroxidase is detected using tetramethylbenzidine, and the plates are read at 450 nm. The assay was normalised by determining the biotin/creatinine ratio in the urine of healthy adults. Urinary biotin excretion was measured in unsupplemented pregnant women. The half-life of biotin excretion after a single oral supplement was determined for healthy volunteers. RESULTS: Urinary biotin excretion in unsupplemented pregnant women was 2.9+/-1.9 micromol/mol creatinine (mean+/-S.D.) and was significantly lower (p<0.001) than those of healthy males and females, which were 9.0+/-5.4 and 7.0+/-2.1 micromol/mol creatinine (mean+/-S.D.), respectively. The half-life of a single oral biotin supplement was 30-40 h, with excretion returning to basal levels at 70 h. CONCLUSION: We have devised a novel binding assay for the direct determination of total biotin excretion in urine, which is suitable for routine clinical laboratory. The assay is inexpensive, simple, rapid, and could be fully automated.


Assuntos
Biotina/urina , Adulto , Proteínas de Bactérias , Ligação Competitiva , Biotina/administração & dosagem , Enzimas Imobilizadas , Feminino , Peroxidase do Rábano Silvestre , Humanos , Masculino , Métodos , Gravidez , Análise Espectral
12.
Clin Chim Acta ; 344(1-2): 123-30, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15149880

RESUMO

Total carnitine in plasma and urine can be measured by high performance liquid chromatography (HPLC) using the novel fluorescent derivatisation reagents 6'-methoxynaphthacyl trifluoromethanesulfonate and 2'-phenanthrenacyl trifluoromethanesulfonate. Sample preparation for total carnitine analysis involves: extraction of plasma and urine in methanol, the optional addition of serine betaine as an internal standard, saponification of acyl carnitines with calcium hydroxide, followed by derivatisation with 6'-methoxynaphthacyl trifluoromethanesulfonate or 2'-phenanthrenacyl trifluoromethanesulfonate. The derivatives were separated using an alumina column and measured by fluorescence detection. The coefficient of variation was below 5% using internal standard calibration, and recoveries of acyl carnitines after saponification were over 90%. The total carnitine method was shown to be linear at biological levels for plasma (over the range 30-130 micromol/l) and urine (over the range 80-180 micromol/l). Advantages of this method include good precision, accuracy and linearity, the use of fluorescence to gain sensitivity, the small sample volume required and a relatively low sample preparation time.


Assuntos
Carnitina/sangue , Carnitina/urina , Cromatografia Líquida de Alta Pressão/métodos , Carnitina/isolamento & purificação , Técnicas e Procedimentos Diagnósticos/normas , Humanos , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...