Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Surg Radiol Anat ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38652252

RESUMO

Anatomical variations are a common feature of the human anatomy. Variation can explain some pathological conditions and is important to keep them in mind during surgical procedures. The relations between nerves and their adjacent arteries have been proposed to play a role in the generation of peripheral trigger migraines. Close opposition between nerves and arteries can lead to vascular compression of the nerve that triggers episodes of pain. We did a routine dissection of the infratemporal fossa and orbital floor by opening the maxillary sinus. Here we report a case where the infraorbital nerves form a nervous loop entrapping the infraorbital artery in the infraorbital channel. Similar cases of close nervous and arterial apposition are described for the auriculotemporal and occipital nerves. We think that accumulating knowledge of these rare variations could expand our understanding of rare conditions such as primary infraorbital neuralgia.

2.
Cancer Rep (Hoboken) ; : e1966, 2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-38148576

RESUMO

BACKGROUND AND AIMS: In approximately 40% of patients with HER2-negative/HR-positive breast cancer tumors, the PIK3CA gene is mutated. Despite this, clinical outcomes vary between studies in this cohort. We aimed to ascertain the prevalence of PIK3CA mutations in patients with metastatic HR+/HER2- breast in Bulgaria, as well the evaluation and comparison of progression free survival (PFS) between wild-type (WT) and mutation-positive groups in the real-world setting. METHODS: Three oncology centers in Bulgaria collected 250 tissue samples between 2016 and 2022 for this multicentric retrospective study. PIK3CA mutations were identified using Real-Time qPCR. The median follow-up period was 35 months. RESULTS: The mean age of the mutant cohort was 57.6 ± 11.6 years, compared to 56.5 ± 12.2 years for the WT cohort (p = .52). The percentage of patients with visceral metastasis was 58.8% (n = 147). Approximately 84.3% (n = 210) of the patients had reached postmenopause. 29.2% (n = 73) of the patients had PIK3CA mutations. The predominant mutation was present in exon 20, H1047R (46.5%). We found a significant correlation only between the presence of a mutation and the metastatic diseases at diagnosis (p = .002). As first-line therapy, 67.1% of patients received endocrine therapy (ET) plus cyclin dependent kinase (CDK4/6) inhibitor, while the remainder received ET alone. The median PFS of patients in the group with the mutation was 32 months (95%, CI: 22-40) compared to 24 months in the WT cohort ((95%, CI: 21-36) (p = .45)); HR = 0.86 (95%, CI: 0.5-1.3) (p = .46). We corroborated our conclusion using propensity matching score analysis, (36 months [95% CI: 20-40] vs. 26 months [95% CI: 21-38], [p = .69]). CONCLUSIONS: We found that the prevalence of PIK3CA mutations in our patients was comparable to what has been reported in other nations. Our results suggest that PIK3CA mutational status has no bearing to ET efficacy in first-line setting.

3.
Int J Comput Assist Radiol Surg ; 18(6): 1101-1108, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37095316

RESUMO

PURPOSE: This paper presents an assessment of a low-cost organ perfusion machine designed for use in research settings. The machine is modular and versatile in nature, built on a robotic operating system (ROS2) pipeline allowing for the addition of specific sensors for different research applications. Here we present the system and the development stages to achieve viability of the perfused organ. METHODS: The machine's perfusion efficacy was assessed by monitoring the distribution of perfusate in livers using methylene blue dye. Functionality was evaluated by measuring bile production after 90 min of normothermic perfusion, while viability was examined using aspartate transaminase assays to monitor cell damage throughout the perfusion. Additionally, the output of the pressure, flow, temperature, and oxygen sensors was monitored and recorded to track the health of the organ during perfusion and assess the system's capability of maintaining the quality of data over time. RESULTS: The results show the system is capable of successfully perfusing porcine livers for up to three hours. Functionality and viability assessments show no deterioration of liver cells once normothermic perfusion had occurred and bile production was within normal limits of approximately 26 ml in 90 min showing viability. CONCLUSION: The developed low-cost perfusion system presented here has been shown to keep porcine livers viable and functional ex vivo. Additionally, the system is capable of easily incorporating several sensors into its framework and simultaneously monitor and record them during perfusion. The work promotes further exploration of the system in different research domains.


Assuntos
Transplante de Fígado , Suínos , Animais , Preservação de Órgãos/métodos , Fígado , Perfusão/métodos , Temperatura
4.
Ultrasound Obstet Gynecol ; 61(1): 81-92, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35353933

RESUMO

OBJECTIVES: A contributing factor to unsuccessful prenatal spina bifida aperta (SBA) repair via an open approach may be incomplete neurosurgical repair causing persistent in-utero leakage of cerebrospinal fluid (CSF) and exposure of the fetal spinal cord to amniotic fluid. We aimed to investigate the neurostructural and neurofunctional efficacy of watertight prenatal SBA repair in a validated SBA fetal lamb model. METHODS: A well-powered superiority study was conducted in the validated SBA fetal lamb model (n = 7 per group). The outcomes of lambs which underwent watertight or non-watertight multilayer repair through an open approach were compared to those of unrepaired SBA lambs (historical controls) at delivery (term = 145 days). At ∼75 days, fetal lambs underwent standardized induction of lumbar SBA. At ∼100 days, they were assigned to an either watertight or non-watertight layered repair group based on an intraoperative watertightness test using subcutaneous fluorescein injection. At 1-2 days postnatally, as primary outcome, we assessed reversal of hindbrain herniation using magnetic resonance imaging (MRI). Secondary proxies of neuroprotection were: absence of CSF leakage at the repair site; hindlimb motor function based on joint-movement score, locomotor grade and Motor Evoked Potential (MEP); four-score neuroprotection scale, encompassing live birth, complete hindbrain herniation reversal, absence of CSF leakage and joint-movement score ≥ 9/15; and brain and spinal cord histology and immunohistochemistry. As the watertightness test cannot be used clinically due to its invasiveness, we developed a potential surrogate intraoperative three-score skin-repair-quality scale based on visual assessment of the quality of the skin repair (suture inter-run distance ≤ 3 mm, absence of tear and absence of ischemia), with high quality defined by a score ≥ 2/3 and low quality by a score < 2/3, and assessed its relationship with improved outcome. RESULTS: Compared with unrepaired lambs, lambs with watertight repair achieved a high level of neuroprotection (neuroprotection score of 4/4 in 5/7 vs 0/7 lambs) as evidenced by: a significant 100% (vs 14%) reversal of hindbrain herniation on MRI; low CSF leakage (14% vs 100%); better hindlimb motor function, with higher joint-movement score, locomotor grade and MEP area under the curve and peak-to-peak amplitude; higher neuronal density in the hippocampus and corpus callosum; and higher reactive astrogliosis at the SBA lesion epicenter. Conversely, lambs with non-watertight SBA repair did not achieve the same level of neuroprotection (score of 4/4 in 1/7 lambs) compared with unrepaired lambs, with: a non-significant 86% (vs 14%) reversal of hindbrain herniation; high CSF leakage (43% vs 100%); no improvement in motor function; low brain neuron count in both the hippocampus and corpus callosum; and small spinal astroglial cell area at the epicenter. Both watertight layered repair and high (≥ 2/3) intraoperative skin-repair-quality score were associated with improved outcome, but the watertightness test and skin-repair-quality scale could not be used interchangeably due to result discrepancies. CONCLUSIONS: Watertight layered fetal SBA repair is neuroprotective since it improves brain and spinal-cord structure and function in the fetal lamb model. This translational research has important clinical implications. A neurosurgical technique that achieves watertightness should be adopted in all fetal centers to improve neuroprotection. Future clinical studies could assess whether a high skin-repair-quality score (≥ 2/3) correlates with neuroprotection. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Doenças do Desenvolvimento Ósseo , Meningomielocele , Espinha Bífida Cística , Disrafismo Espinal , Gravidez , Feminino , Ovinos , Animais , Neuroproteção , Disrafismo Espinal/cirurgia , Feto/cirurgia , Espinha Bífida Cística/cirurgia , Meningomielocele/cirurgia
5.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 2565-2568, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086012

RESUMO

This paper presents a novel, low cost, organ perfusion machine designed for use in research. The modular and versatile nature of the system allows for additional sensing equipment to be added or adapted for specific use. Here we introduce the system and present its preliminary evaluation by assessing its ability to maintain a predetermined input pressure. A proportional-integral-derivative (PID) controller was implemented and tested on a porcine liver to maintain input pressure to the hepatic artery and compared to bench tests. The results confirmed the effectiveness of the controller for maintaining input through the hepatic artery (HA) in a timely manner. Clinical Relevance-Machine Perfusion (MP) is proving to be an invaluable adjunct in clinical practice. With its ongoing success in the transplant arena, we propose MP for use in research. A cost-effective, versatile system that can be modified for specific research use to test new pharmacological therapies, imaging techniques or develop simulation training would be beneficial.


Assuntos
Fígado , Animais , Perfusão/métodos , Suínos
6.
Front Surg ; 9: 957450, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35990100

RESUMO

Introduction: Microsurgery for the clipping of intracranial aneurysms remains a technically challenging and high-risk area of neurosurgery. We aimed to describe the technical challenges of aneurysm surgery, and the scope for technological innovations to overcome these barriers from the perspective of practising neurovascular surgeons. Materials and Methods: Consultant neurovascular surgeons and members of the British Neurovascular Group (BNVG) were electronically invited to participate in an online survey regarding surgery for both ruptured and unruptured aneurysms. The free text survey asked three questions: what do they consider to be the principal technical barriers to aneurysm clipping? What technological advances have previously contributed to improving the safety and efficacy of aneurysm clipping? What technological advances do they anticipate improving the safety and efficacy of aneurysm clipping in the future? A qualitative synthesis of responses was performed using multi-rater emergent thematic analysis. Results: The most significant reported historical advances in aneurysm surgery fell into five themes: (1) optimising clip placement, (2) minimising brain retraction, (3) tissue handling, (4) visualisation and orientation, and (5) management of intraoperative rupture. The most frequently reported innovation by far was indocyanine green angiography (84% of respondents). The three most commonly cited future advances were hybrid surgical and endovascular techniques, advances in intraoperative imaging, and patient-specific simulation and planning. Conclusions: While some surgeons perceive that the rate of innovation in aneurysm clipping has been dwarfed in recent years by endovascular techniques, surgeons surveyed highlighted a broad range of future technologies that have the potential to continue to improve the safety of aneurysm surgery in the future.

7.
Wiad Lek ; 75(1 pt 2): 300-303, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35182139

RESUMO

OBJECTIVE: The aim: To analyze the effect of Korean red ginseng on status of the vegetative nervous system and well-being of patients with asthenic syndrome assotiated with mild combat traumatic brain injury. PATIENTS AND METHODS: Materials and methods: We have examined 42 patients. Duration of their injury was from 4 to 6 years. We have investigated the indices of the vegetative tonus, vegetative reactivity and vegetative provisioning, its neurally mediated component - adrenaline and noradrenaline and melatonin hormone in daily urine. Some neuropsychological data were investigated with the help of HAM method (Health, Activity and Mood scale). RESULTS: Results: After the treatment with Korean red ginseng all indices of the vegetative nervous system improved significantly. Accordingly, the rates of adrenaline and noradrenaline and the hormone melatonin, which were reduced before treatment in most of the examined, increased. The HAM values also improved after the treatment. CONCLUSION: Conclusions: The use of Korean red ginseng restores efficiency, sleep, activity, and improves the mood of patients with aftereffects of mild traumatic brain injury and does not cause any adverse reaction.


Assuntos
Concussão Encefálica , Melatonina , Astenia , Concussão Encefálica/psicologia , Humanos , Síndrome
8.
Front Robot AI ; 9: 1099275, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36686214

RESUMO

In robotic-assisted partial nephrectomy, surgeons remove a part of a kidney often due to the presence of a mass. A drop-in ultrasound probe paired to a surgical robot is deployed to execute multiple swipes over the kidney surface to localise the mass and define the margins of resection. This sub-task is challenging and must be performed by a highly-skilled surgeon. Automating this sub-task may reduce cognitive load for the surgeon and improve patient outcomes. The eventual goal of this work is to autonomously move the ultrasound probe on the surface of the kidney taking advantage of the use of the Pneumatically Attachable Flexible (PAF) rail system, a soft robotic device used for organ scanning and repositioning. First, we integrate a shape-sensing optical fibre into the PAF rail system to evaluate the curvature of target organs in robotic-assisted laparoscopic surgery. Then, we investigate the impact of the PAF rail's material stiffness on the curvature sensing accuracy, considering that soft targets are present in the surgical field. We found overall curvature sensing accuracy to be between 1.44% and 7.27% over the range of curvatures present in adult kidneys. Finally, we use shape sensing to plan the trajectory of the da Vinci surgical robot paired with a drop-in ultrasound probe and autonomously generate an Ultrasound scan of a kidney phantom.

9.
Surg Oncol ; 38: 101637, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34358880

RESUMO

BACKGROUND: Compared to open surgery, minimally invasive liver resection has improved short term outcomes. It is however technically more challenging. Navigated image guidance systems (IGS) are being developed to overcome these challenges. The aim of this systematic review is to provide an overview of their current capabilities and limitations. METHODS: Medline, Embase and Cochrane databases were searched using free text terms and corresponding controlled vocabulary. Titles and abstracts of retrieved articles were screened for inclusion criteria. Due to the heterogeneity of the retrieved data it was not possible to conduct a meta-analysis. Therefore results are presented in tabulated and narrative format. RESULTS: Out of 2015 articles, 17 pre-clinical and 33 clinical papers met inclusion criteria. Data from 24 articles that reported on accuracy indicates that in recent years navigation accuracy has been in the range of 8-15 mm. Due to discrepancies in evaluation methods it is difficult to compare accuracy metrics between different systems. Surgeon feedback suggests that current state of the art IGS may be useful as a supplementary navigation tool, especially in small liver lesions that are difficult to locate. They are however not able to reliably localise all relevant anatomical structures. Only one article investigated IGS impact on clinical outcomes. CONCLUSIONS: Further improvements in navigation accuracy are needed to enable reliable visualisation of tumour margins with the precision required for oncological resections. To enhance comparability between different IGS it is crucial to find a consensus on the assessment of navigation accuracy as a minimum reporting standard.


Assuntos
Hepatectomia/métodos , Laparoscopia/métodos , Neoplasias Hepáticas/cirurgia , Cirurgia Assistida por Computador/métodos , Humanos , Neoplasias Hepáticas/patologia , Prognóstico
10.
Neuroimage ; 232: 117895, 2021 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-33617994

RESUMO

BACKGROUND: After more than eight decades of electroconvulsive therapy (ECT) for pharmaco-resistant depression, the mechanisms governing its anti-depressant effects remain poorly understood. Computational anatomy studies using longitudinal T1-weighted magnetic resonance imaging (MRI) data have demonstrated ECT effects on hippocampus volume and cortical thickness, but they lack the interpretational specificity about underlying neurobiological processes. METHODS: We sought to fill in the gap of knowledge by acquiring quantitative MRI indicative for brain's myelin, iron and tissue water content at multiple time-points before, during and after ECT treatment. We adapted established tools for longitudinal spatial registration of MRI data to the relaxometry-based multi-parameter maps aiming to preserve the initial total signal amount and introduced a dedicated multivariate analytical framework. RESULTS: The whole-brain voxel-based analysis based on a multivariate general linear model showed that there is no brain tissue oedema contributing to the predicted ECT-induced hippocampus volume increase neither in the short, nor in the long-term observations. Improvements in depression symptom severity over time were associated with changes in both volume estimates and brain tissue properties expanding beyond mesial temporal lobe structures to anterior cingulate cortex, precuneus and striatum. CONCLUSION: The obtained results stemming from multi-contrast MRI quantitative data provided a fingerprint of ECT-induced brain tissue changes over time that are contrasted against the background of established morphometry findings. The introduced data processing and statistical testing algorithms provided a reliable analytical framework for longitudinal multi-parameter brain maps. The results, particularly the evidence of lack of ECT impact on brain tissue water, should be considered preliminary considering the small sample size of the study.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/diagnóstico por imagem , Transtorno Depressivo Maior/diagnóstico por imagem , Transtorno Depressivo Maior/terapia , Eletroconvulsoterapia/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Encéfalo/fisiopatologia , Transtorno Depressivo Maior/fisiopatologia , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
11.
Eur Psychiatry ; 63(1): e88, 2020 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-32921324

RESUMO

BACKGROUND: Healthcare services are increasingly confronted with challenges related to old age mental disorders. The survey aimed to provide an overview of existing psychogeriatric services in Albania, Bulgaria, Greece, and North Macedonia. METHODS: After identification of psychogeriatric units across the four countries, their head physicians were asked to provide data on their clinical, teaching, and research activity, as well as staff composition. Moreover, the attitudes of head physicians to current needs and future service development were explored. RESULTS: A total of 15 psychogeriatric units were identified (3 in Bulgaria, 8 in Greece, and 4 in North Macedonia). Results show wide variation regarding the location, team size and composition, service availability, numbers of patients attending, and inpatient treatment length. Most head physicians underscored the urgent need for breakthroughs in the graduate and postgraduate education in psychogeriatrics of medical and nonmedical professionals, as well as in the interconnection of their units with community primary healthcare services and long-term care facilities for seniors via telemedicine. They would welcome the development of national standards for psychogeriatric units, potentially embodying clear pointers for action. A number of head physicians advocated the development of nationwide old age mental health registries. CONCLUSIONS: Regional disparities in resources and services for seniors' mental health services were unveiled. These data may enrich the dialogue on optimizing psychogeriatric services through planning future cross-border collaborations mainly based on telemedicine services, especially in the era of the novel coronavirus pandemic, and training/education in psychogeriatrics of mental health professionals.


Assuntos
Atitude do Pessoal de Saúde , Necessidades e Demandas de Serviços de Saúde , Transtornos Mentais/terapia , Serviços de Saúde Mental , Bulgária , Grécia , Pesquisas sobre Atenção à Saúde , Humanos , República da Macedônia do Norte , Telemedicina/métodos
12.
Surg Endosc ; 34(10): 4702-4711, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32780240

RESUMO

BACKGROUND: The laparoscopic approach to liver resection may reduce morbidity and hospital stay. However, uptake has been slow due to concerns about patient safety and oncological radicality. Image guidance systems may improve patient safety by enabling 3D visualisation of critical intra- and extrahepatic structures. Current systems suffer from non-intuitive visualisation and a complicated setup process. A novel image guidance system (SmartLiver), offering augmented reality visualisation and semi-automatic registration has been developed to address these issues. A clinical feasibility study evaluated the performance and usability of SmartLiver with either manual or semi-automatic registration. METHODS: Intraoperative image guidance data were recorded and analysed in patients undergoing laparoscopic liver resection or cancer staging. Stereoscopic surface reconstruction and iterative closest point matching facilitated semi-automatic registration. The primary endpoint was defined as successful registration as determined by the operating surgeon. Secondary endpoints were system usability as assessed by a surgeon questionnaire and comparison of manual vs. semi-automatic registration accuracy. Since SmartLiver is still in development no attempt was made to evaluate its impact on perioperative outcomes. RESULTS: The primary endpoint was achieved in 16 out of 18 patients. Initially semi-automatic registration failed because the IGS could not distinguish the liver surface from surrounding structures. Implementation of a deep learning algorithm enabled the IGS to overcome this issue and facilitate semi-automatic registration. Mean registration accuracy was 10.9 ± 4.2 mm (manual) vs. 13.9 ± 4.4 mm (semi-automatic) (Mean difference - 3 mm; p = 0.158). Surgeon feedback was positive about IGS handling and improved intraoperative orientation but also highlighted the need for a simpler setup process and better integration with laparoscopic ultrasound. CONCLUSION: The technical feasibility of using SmartLiver intraoperatively has been demonstrated. With further improvements semi-automatic registration may enhance user friendliness and workflow of SmartLiver. Manual and semi-automatic registration accuracy were comparable but evaluation on a larger patient cohort is required to confirm these findings.


Assuntos
Realidade Aumentada , Fígado/cirurgia , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
13.
Med Image Anal ; 53: 11-25, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30660103

RESUMO

Accounting for 26% of all new cancer cases worldwide, breast cancer remains the most common form of cancer in women. Although early breast cancer has a favourable long-term prognosis, roughly a third of patients suffer from a suboptimal aesthetic outcome despite breast conserving cancer treatment. Clinical-quality 3D modelling of the breast surface therefore assumes an increasingly important role in advancing treatment planning, prediction and evaluation of breast cosmesis. Yet, existing 3D torso scanners are expensive and either infrastructure-heavy or subject to motion artefacts. In this paper we employ a single consumer-grade RGBD camera with an ICP-based registration approach to jointly align all points from a sequence of depth images non-rigidly. Subtle body deformation due to postural sway and respiration is successfully mitigated leading to a higher geometric accuracy through regularised locally affine transformations. We present results from 6 clinical cases where our method compares well with the gold standard and outperforms a previous approach. We show that our method produces better reconstructions qualitatively by visual assessment and quantitatively by consistently obtaining lower landmark error scores and yielding more accurate breast volume estimates.


Assuntos
Neoplasias da Mama/cirurgia , Mama/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Cirurgia Assistida por Computador/métodos , Gravação em Vídeo/instrumentação , Pontos de Referência Anatômicos , Calibragem , Estética , Feminino , Humanos
15.
IEEE Trans Med Imaging ; 37(5): 1204-1213, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29727283

RESUMO

Estimating the 3-D pose of instruments is an important part of robotic minimally invasive surgery for automation of basic procedures as well as providing safety features, such as virtual fixtures. Image-based methods of 3-D pose estimation provide a non-invasive low cost solution compared with methods that incorporate external tracking systems. In this paper, we extend our recent work in estimating rigid 3-D pose with silhouette and optical flow-based features to incorporate the articulated degrees-of-freedom (DOFs) of robotic instruments within a gradient-based optimization framework. Validation of the technique is provided with a calibrated ex-vivo study from the da Vinci Research Kit (DVRK) robotic system, where we perform quantitative analysis on the errors each DOF of our tracker. Additionally, we perform several detailed comparisons with recently published techniques that combine visual methods with kinematic data acquired from the joint encoders. Our experiments demonstrate that our method is competitively accurate while relying solely on image data.


Assuntos
Imageamento Tridimensional , Procedimentos Cirúrgicos Robóticos , Animais , Fenômenos Biomecânicos , Humanos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Modelos Biológicos , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Instrumentos Cirúrgicos , Punho/fisiologia
16.
Eur J Vasc Endovasc Surg ; 52(4): 451-457, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27328621

RESUMO

OBJECTIVES: Fenestrated endovascular aneurysm repair (FEVAR) exposes operators and patients to considerable amounts of radiation. Introduction of fusion of three-dimensional (3D) computed tomography (CT) with intraoperative fluoroscopy puts new focus on advanced imaging techniques in the operating environment and has been found to reduce radiation and facilitate faster repair. The aim of this study is to evaluate the radiation dose effect of introducing a team-based approach to complex aortic repair. METHODS: Procedural details for a cohort of 21 patients undergoing FEVAR after fusion-guided (Modern Group) imaging was introduced are compared with 21 patients treated in the immediate 12 months prior to implementation (Historic Group) at a centre with expertise in FEVAR. Non-parametric tests were used to compare procedure time (PT), air kerma, dose-area product (DAP), fluoroscopy time (FT), estimated blood loss (EBL) and pre- and post-operative estimated glomerular filtration rate (eGFR) between the groups. RESULTS: Change in operative approach resulted in a significant reduction in PT for the Modern group (median 285 mins; interquartile range 268-322) compared with the Historic group (450 mins; IQR 360-540 p = <0.001). There were reductions in skin dose for the Modern group (1.6 Gy; IQR 1.09-2.1) compared with the Historic group (4.4 Gy; 3.2-7.05 p = <0.001), and DAP (Modern 159 Gy.cm2; IQR 123-226 vs 264.93 Gy.cm2; 173.3-366.8 for Historic (p = 0.006). There were no significant differences in FT, and pre- and post-operative eGFR between the two groups. Weight and height were distributed equally across both groups. Structured dose reports including the changes in frame rate were not available for analysis. CONCLUSIONS: Implementation of a team-based approach to radiation reduction significantly reduces radiation dose. These findings suggest that the radiation safety awareness that accompanies the introduction of fusion imaging may improve the overall radiation safety profile of FEVAR for patients and providers.


Assuntos
Procedimentos Endovasculares , Doses de Radiação , Implante de Prótese Vascular , Fluoroscopia , Humanos , Tomografia Computadorizada por Raios X
17.
J Microbio Robot ; 11(1): 1-18, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-29082124

RESUMO

Digestive diseases are a major burden for society and healthcare systems, and with an aging population, the importance of their effective management will become critical. Healthcare systems worldwide already struggle to insure quality and affordability of healthcare delivery and this will be a significant challenge in the midterm future. Wireless capsule endoscopy (WCE), introduced in 2000 by Given Imaging Ltd., is an example of disruptive technology and represents an attractive alternative to traditional diagnostic techniques. WCE overcomes conventional endoscopy enabling inspection of the digestive system without discomfort or the need for sedation. Thus, it has the advantage of encouraging patients to undergo gastrointestinal (GI) tract examinations and of facilitating mass screening programmes. With the integration of further capabilities based on microrobotics, e.g. active locomotion and embedded therapeutic modules, WCE could become the key-technology for GI diagnosis and treatment. This review presents a research update on WCE and describes the state-of-the-art of current endoscopic devices with a focus on research-oriented robotic capsule endoscopes enabled by microsystem technologies. The article also presents a visionary perspective on WCE potential for screening, diagnostic and therapeutic endoscopic procedures.

18.
IEEE Trans Med Imaging ; 33(10): 1913-30, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24876109

RESUMO

Intra-operative imaging techniques for obtaining the shape and morphology of soft-tissue surfaces in vivo are a key enabling technology for advanced surgical systems. Different optical techniques for 3-D surface reconstruction in laparoscopy have been proposed, however, so far no quantitative and comparative validation has been performed. Furthermore, robustness of the methods to clinically important factors like smoke or bleeding has not yet been assessed. To address these issues, we have formed a joint international initiative with the aim of validating different state-of-the-art passive and active reconstruction methods in a comparative manner. In this comprehensive in vitro study, we investigated reconstruction accuracy using different organs with various shape and texture and also tested reconstruction robustness with respect to a number of factors like the pose of the endoscope as well as the amount of blood or smoke present in the scene. The study suggests complementary advantages of the different techniques with respect to accuracy, robustness, point density, hardware complexity and computation time. While reconstruction accuracy under ideal conditions was generally high, robustness is a remaining issue to be addressed. Future work should include sensor fusion and in vivo validation studies in a specific clinical context. To trigger further research in surface reconstruction, stereoscopic data of the study will be made publically available at www.open-CAS.com upon publication of the paper.


Assuntos
Imageamento Tridimensional/métodos , Laparoscopia/métodos , Cirurgia Assistida por Computador/métodos , Animais , Endoscópios , Rim/anatomia & histologia , Rim/cirurgia , Fígado/anatomia & histologia , Fígado/cirurgia , Modelos Biológicos , Reprodutibilidade dos Testes , Suínos
19.
Med Image Anal ; 17(8): 974-96, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23837969

RESUMO

One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-operative morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon's navigation capabilities by observing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted instruments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This paper reviews the state-of-the-art methods for optical intra-operative 3D reconstruction in laparoscopic surgery and discusses the technical challenges and future perspectives towards clinical translation. With the recent paradigm shift of surgical practice towards MIS and new developments in 3D optical imaging, this is a timely discussion about technologies that could facilitate complex CAS procedures in dynamic and deformable anatomical regions.


Assuntos
Algoritmos , Inteligência Artificial , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Laparoscopia/métodos , Reconhecimento Automatizado de Padrão/métodos , Cirurgia Assistida por Computador/métodos , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Eur J Vasc Endovasc Surg ; 45(5): 509-15, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23465454

RESUMO

OBJECTIVES: Accurate assessment and credentialing of physicians is essential. Objective motion analysis of guide-wire/catheter manipulation to assess proficiency during endovascular interventions remains unexplored. This study aims to assess its feasibility and its role in evaluation of technical ability. MATERIALS AND METHODS: A semi-automated catheter-tracking software was developed which allows for frame-by-frame motion analysis of fluoroscopic videos and calculation 2D catheter tip path-length. 21 interventionalists (6 cardiologists, 8 interventional radiologists, 7 vascular surgeons; 14/21 had performed >500 endovascular procedures) performed an identical carotid artery stenting procedure (CAS) on a VIST simulator (Mentice, Gothenburg, Sweden). Operators were sub-divided into four categories according to CAS experience: 6 inexperienced (0 CAS-group A), 3 low-volume (1-20 CAS-group B), 5 moderate-volume (21-50 CAS-group C) and 7 high-volume (>50 CAS-group D) CAS experience. Total PL was calculated for each case and comparisons made between groups. PL was correlated with: quantitative, simulator-derived metrics and qualitative performance scores (generic and procedure-specific) derived from post-hoc video analysis by three blinded observers. RESULTS: Group D used 5160.3 (inter-quartile range- IQR 4046.4-7142.9) pixels of movement, compared to 6856.7 (5914.4-8106.9) for group A (p = 0.046); 10,905.1 (7851.1-14,381.5) for group B (p = 0.017); and 9482.6 (8663.5-13,847.6) for group C (p = 0.003). Statistically significant inverse correlations were seen between total PL and qualitative performance scores (rho = -0.519 for generic (p = 0.027) rho = -0.567 for procedure-specific (p = 0.014) scores). PL did not correlate with any of the simulator-derived metrics (errors, contrast volume, total procedure and fluoroscopy times, cine-loops used). CONCLUSION: Endovascular instrument video motion analysis is feasible and may represent a valuable tool for the objective assessment of endovascular skill.


Assuntos
Competência Clínica , Procedimentos Endovasculares/educação , Gravação de Videoteipe , Estudos de Viabilidade , Humanos , Projetos Piloto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...