Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Head Face Med ; 19(1): 28, 2023 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-37430304

RESUMO

BACKGROUND: Computed tomography (CT) has become the primary imaging modality for visualization of the paranasal sinuses. In this retrospective, single center patient study the radiation dose development in the past 12 years in CT imaging of the paranasal sinuses was assessed. METHODS: The computed tomography dose index (CTDIVol) and dose length product (DLP) of a total of 1246 patients (average age: 41 ± 18 years, 361 females, 885 males) were evaluated, who received imaging of the paranasal sinuses either for chronic sinusitis diagnostic, preoperatively or posttraumatically. Scans were performed on three different CT scanners (Somatom Definition AS, Somatom Definition AS+, Somatom Force, all from Siemens Healthineers) and on one CBCT (Morita) ranging from 2010 to 2022. Reconstruction techniques were filtered back projection and three generations of iterative reconstruction (IRIS, SAFIRE, ADMIRE, all from Siemens Healthineers). Group comparisons were performed using either parametrical (ANOVA) or non-parametrical tests (Kruskal-Wallis Test), where applicable. RESULTS: Over the past 12 years, there was a 73%, 54%, and 66% CTDIVol reduction and a significant (p < 0.001) 72%, 33%, and 67% DLP reduction in assessing the paranasal sinuses for chronic sinusitis, preoperatively and posttraumatically, respectively. CONCLUSION: Technological developments in CT imaging, both hardware and software based, have led to a significant reduction in dose exposure in recent years. Particularly in imaging of the paranasal sinuses, the reduction of radiation exposure is of great interest due to the often young patient age and radiation-sensitive organs in the area of radiation exposure.


Assuntos
Seios Paranasais , Doses de Radiação , Tomografia Computadorizada por Raios X , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/tendências , Seios Paranasais/diagnóstico por imagem
2.
PLoS One ; 18(1): e0279907, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36607911

RESUMO

OBJECTIVES: Paranasal sinus imaging due to chronic inflammatory disease is one of the most common examinations in head and neck radiology with CT imaging considered the current gold standard. In this phantom study we analyzed different low dose CT protocols in terms of image quality, radiation exposure and subjective evaluation in order to establish an optimized scanning protocol. METHODS: In a phantom study, an Alderson phantom was scanned using 12 protocols between 70-120 kV and 25-200 mAs with and without tin filtration. For all datasets, iterative reconstruction was used. Data were objectively evaluated (image noise, (dose-weighted) contrast-to-noise ratio) and for subjective evaluation an online survey using a Likert scale was performed to reach a large group of clinically experienced reader (n = 62). The protocol was considered diagnostically insufficient if the median score was 4 and above and if more than 10% of raters scored 4 and above on the Likert scale. For an interreader agreement an ICC was calculated. To compare clinical value in relation to the applied dose and the objective image parameters, we calculated a figure of merit (FOM) and ranked the protocols accordingly. RESULTS: There was an overall moderate agreement between the 62 readers for the 12 examined CT protocols. In this phantom study, protocols with 100 kV with spectral shaping and 50-100 mAs obtained the best results for its combination of dose, image quality and clinical information value for diagnosing sinusitis (FOM 1st- 2nd place) with the 70 kV and 50 mAs as a good alternative as well (Sinusitis: FOM shared 2nd). For preoperative planning, where a higher dose is necessary, 100 kV with spectral shaping and 100 mAs achieved the overall best results (FOM 1st place) with 70 kV and 50 mAs ranking 4th. CONCLUSION: 100-kV protocols with spectral shaping or low kV protocols (70 kV) with a similarly low dose showed the best figure of merit for imaging sinonasal disease and preoperative planning. With modern scanner technology available, spectral shaping or low KV protocols should be used for sinusitis imaging.


Assuntos
Sinusite , Estanho , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Intensificação de Imagem Radiográfica/métodos , Sinusite/diagnóstico por imagem , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...