Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 5705-5708, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28269550

RESUMO

Electrode and cap concepts for continuous and ubiquitous monitoring of brain activity will open up new fields of application and contribute to increased use of electroencephalography (EEG) in clinical routine, neurosciences, brain-computer-interfacing and out-of-the-lab monitoring. However, mobile and unobtrusive applications are currently hindered by the lack of applicable convenient and reliable electrode and cap systems. We propose a novel modular electrode concept based on a flexible polymer substrate, coated with electrically conductive metallic films. The overall concept enables design adaptation to different head regions and cap designs. We describe the single modules of the system and investigate the influence of electrode pin number, coating material and adduction force on electrode-skin impedance and perceived wearing comfort. Our results contribute to rapid and comfortable multichannel dry EEG.


Assuntos
Eletroencefalografia/instrumentação , Desenho de Equipamento , Condutividade Elétrica , Eletrodos , Humanos , Metais , Polímeros
2.
Neuroimage ; 70: 410-22, 2013 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-23291276

RESUMO

Magnetoencephalography (MEG) and electroencephalography (EEG) allow functional brain imaging with high temporal resolution. While solving the inverse problem independently at every time point can give an image of the active brain at every millisecond, such a procedure does not capitalize on the temporal dynamics of the signal. Linear inverse methods (minimum-norm, dSPM, sLORETA, beamformers) typically assume that the signal is stationary: regularization parameter and data covariance are independent of time and the time varying signal-to-noise ratio (SNR). Other recently proposed non-linear inverse solvers promoting focal activations estimate the sources in both space and time while also assuming stationary sources during a time interval. However such a hypothesis holds only for short time intervals. To overcome this limitation, we propose time-frequency mixed-norm estimates (TF-MxNE), which use time-frequency analysis to regularize the ill-posed inverse problem. This method makes use of structured sparse priors defined in the time-frequency domain, offering more accurate estimates by capturing the non-stationary and transient nature of brain signals. State-of-the-art convex optimization procedures based on proximal operators are employed, allowing the derivation of a fast estimation algorithm. The accuracy of the TF-MxNE is compared with recently proposed inverse solvers with help of simulations and by analyzing publicly available MEG datasets.


Assuntos
Eletroencefalografia/métodos , Magnetoencefalografia/métodos , Modelos Neurológicos , Humanos , Fatores de Tempo
4.
Clin Neurophysiol ; 123(8): 1581-5, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22321298

RESUMO

OBJECTIVE: While standard magnetoencephalographic systems record only one component of the biomagnetic field, novel vector-biomagnetometers enable measurement of all three components of the field at each sensing point. Because information content in standard one-component magnetoencephalography (MEG) is often not adequate to reconstruct quasi-radial dipolar activity, we tested the hypothesis that quasi-radial activity can be estimated using three-component MEG. METHODS: We stimulated the right median nerve in 11 healthy volunteers and recorded the somatosensory evoked fields over the contralateral hemisphere using a novel vector-biomagnetometer system comprised of SQUID-based magnetometer triplets. Source reconstruction for the early cortical components N20m and P25m was subsequently performed. RESULTS: Both tangential and quasi-radial dipolar activity could be reconstructed in 10 of the 11 participants. Dipole locations were found in the vicinity of the central sulcus, and dipole orientations were predominantly tangential for N20m and quasi-radial for P25m. The mean location difference between the tangential and quasi-radial dipoles was 11.9 mm and the mean orientation difference was 97.5°. CONCLUSIONS: Quasi-radial dipolar activity can be reconstructed from three-component magnetoencephalographic measurements. SIGNIFICANCE: Three-component MEG provides higher information content than does standard MEG.


Assuntos
Potenciais Somatossensoriais Evocados/fisiologia , Nervo Mediano/fisiologia , Córtex Somatossensorial/fisiologia , Adulto , Estimulação Elétrica , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Magnetoencefalografia , Masculino
5.
Artigo em Inglês | MEDLINE | ID: mdl-22254518

RESUMO

The analysis of somatosensory evoked potentials (SEP) and / or fields (SEF) is a well-established and important tool for investigating the functioning of the peripheral and central human nervous system. A standard technique to evoke SEPs / SEFs is the stimulation of the median nerve by using a bipolar electrical stimulus. We aim at an alternative stimulation technique enabling stimulation of deep nerve structures while reducing patient stress and error susceptibility. In the current study, we apply a commercial transcranial magnetic stimulation system for peripheral magnetic stimulation of the median nerve. We compare the results of simultaneously recorded EEG signals to prove applicability of our technique to evoke SEPs including low frequency components (LFC) as well as high frequency oscillations (HFO). Therefore, we compare amplitude, latency and time-frequency characteristics of the SEP of 14 healthy volunteers after electric and magnetic stimulation. Both low frequency components and high frequency oscillations were detected. The HFOs were superimposed onto the primary cortical response N20. Statistical analysis revealed significantly lower amplitudes and increased latencies for LFC and HFO components after magnetic stimulation. The differences indicate the inability of magnetic stimulation to elicit supramaximal responses. A psycho-perceptual evaluation showed that magnetic stimulation was less unpleasant for 12 out of the 14 volunteers. In conclusion, we showed that LFC and HFO components related to median nerve stimulation can be evoked by peripheral magnetic stimulation.


Assuntos
Relógios Biológicos/fisiologia , Estimulação Elétrica/métodos , Eletroencefalografia/métodos , Potenciais Somatossensoriais Evocados/fisiologia , Nervo Mediano/fisiologia , Córtex Somatossensorial/fisiologia , Adulto , Feminino , Humanos , Campos Magnéticos , Masculino , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...