Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-36937038

RESUMO

Background: Warm fresh whole blood (WFWB) is an ideal resuscitation fluid for exsanguinating patients but there are myriad logistic and infectious issues associated with its use. Cold whole blood (CWB) may be an acceptable alternative to the reconstituted whole blood (RWB), the current standard of care. A leukoreduction filter has been developed which maintains platelet count while eliminating white blood cells but its effect on platelet function is unknown. We hypothesize that CWB will retain an acceptable functional coagulation profile after filtration and over time. Study Design and Methods: WFWB and CWB samples were obtained from eight donors and four units of RWB were created. The quantitative and qualitative in vitro coagulation profiles of WFWB, RWB, and CWB over time were compared. Results: Filtration was successful at removing white blood cells (5.5 ± 1.2 vs. 0.3 ± 0.3 × 106/L) while retaining an adequate platelet count (172.0 ± 47.0 to 166.0 ± 42.3 × 109/L) and hemoglobin concentration (13.7 ± 0.5 vs. 13.0 ± 0.7 g/dL). Rotational Thromboelastography (ROTEM) results revealed a similar clotting time (CT) before and after filtration (64.9 ± 5.1 vs. 64.1 ± 6.8 s) but a decreased maximum clot firmness (MCF) (58.6 ± 4.2 vs. 54.9 ± 4.6 mm). Platelet aggregation decreased substantially (28.8 ± 6.7 vs. 9.3 ± 2.1 ohm) immediately after filtration. CWB function continued to diminish over time. Conclusion: CWB holds great promise as a surrogate for WFWB, but use of a platelet-sparing LR filter diminishes platelet function almost immediately after filtration.

3.
Immunohematology ; 24(3): 93-101, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19845076

RESUMO

The Mayo Clinic, in Rochester, Minnesota, recently set forth a directive to develop a Mayo Emergency Incident Command System (MEICS) plan to respond to major disasters. The MEICS plan that was developed interfaces with national response plans to ensure effective communication and coordination between our institution and local, state, and federal agencies to establish a common language and communication structure. The MEICS plan addresses multiple aspects of dealing with resource needs during a crisis, including the need for blood and transfusion medicine services. The MEICS plan was developed to supplement our current local emergency preparedness procedures and provide a mechanism for responding to the escalating severity of an emergency to deal with situations of a magnitude that is outside the normal experience. A plan was developed to interface the existing Transfusion Medicine disaster plan standard operating procedures (SOP) with the institutional and Department of Laboratory Medicine (DLMP) MEICS plans. The first step in developing this interface was defining MEICS. Other major steps were defining the chain of command, developing a method for visually indicating who is "in charge," planning communication, defining the actions to be taken, assessing resource needs, developing flowcharts and updating SOPs, and developing a blood rationing team to deal with anticipated blood shortages. Several key features of the interface and updated disaster plan that were developed are calling trees for response personnel, plans for relocating leadership to alternative command centers, and action sheets to assist with resource assessment. The action sheets also provide documentation of key actions by response personnel.


Assuntos
Transfusão de Sangue , Planejamento em Desastres/organização & administração , Serviços Médicos de Emergência/organização & administração , Laboratórios Hospitalares/organização & administração , Planejamento em Desastres/normas , Serviços Médicos de Emergência/normas , Humanos , Laboratórios Hospitalares/normas , Minnesota
4.
Immunohematology ; 23(2): 55-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18004934

RESUMO

Anti-AnWj (Anton) has been associated with clinically significant hemolytic transfusion reactions. More than 99 percent of studied populations have RBCs that express the antigen. Reported here is a patient with anti-AnWj who was transfused with antigen-positive RBCs without adverse reaction.


Assuntos
Antígenos de Grupos Sanguíneos/imunologia , Incompatibilidade de Grupos Sanguíneos/imunologia , Transfusão de Eritrócitos/efeitos adversos , Anemia/terapia , Humanos , Isoanticorpos/sangue , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
6.
Immunohematology ; 18(2): 40-2, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-15373563

RESUMO

The Rh blood group antigen e is of high incidence and has many epitopes. Partial expression may occur, more commonly in black persons. Individuals with e variant phenotypes can make antibodies to epitopes they lack. While some of these antibodies may be specific for an antigen, e.g., hrB, others, like anti-Rh17 (anti-Hro), show broader specificity, compatible only with D-- and Rhnull red blood cells (RBCs). Anti-Rh17 in persons of the D-- phenotype has been reported to cause mild to fatal HDN. We report an example of anti-Rh17 produced by a black female with an e variant RBC phenotype that caused moderate HDN. A panel of seven monoclonal anti-e demonstrated her RBCs carried a variant e antigen, and her genotype was RHD, RHce by PCR-RFLP analysis. Amniotic fluid with.OD450 values from 30 to 35 weeks' gestation predicted moderate HDN probability by the Liley method. At 38+ weeks, a viable 3165 g female infant was delivered. The infant's direct antiglobulin test was 2+ with anti-IgG. Total bilirubin rose to 14.2 mg/dL within 48 hours. Indirect bilirubin peaked at 14.7 mg/dL. The bilirubin responded to triple phototherapy. The infant was discharged on day 6. Potential for infant morbidity due to anti-Rh17- mediated HDN and the importance of specifying risks to women with this antibody if they contemplate pregnancy are discussed.

8.
Immunohematology ; 12(2): 62-5, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-15387742

RESUMO

Anti-Holley (Hy) has been reported as an IgG antibody occurring in previously transfused or multiparous black patients. In this case anti- Hy was identified in a 16-year-old black, primigravida female admitted at 32 weeks gestation because of premature rupture of the membranes. On admission, her blood type was determined to be A2B, D-positive and an antibody screen was negative. A second antibody screen, performed 4 days later, was positive in all three cells. Anti-Hy was subsequently identified. The antibody was reactive at room temperature, 37 degrees C, and in the antiglobulin phase. IgG and IgM components of anti-Hy were demonstrated in the maternal serum, documenting a primary immune response. This resulted in serologic findings not previously described for anti-Hy. A direct antiglobulin test on the newborn red cells was negative and there was no clinical evidence of hemolytic disease of the newborn (HDN). A monocyte monolayer assay performed with maternal serum yielded negative results. Recent scientific information has resulted in the placement of Hy in the Dombrock blood group system. Alloantibodies to Dombrock system antigens have not been associated with severe HDN.

9.
Immunohematology ; 11(1): 11-3, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-15447072

RESUMO

This study compared the performance of polyethylene glycol (PEG) and low-ionic saline solutions (LISS) as enhancement media for routine use in a large transfusion service. A PEG additive solution (PEG plus LISS) was compared to a LISS additive (LISS plus polymers) and to an albumin-indirect antiglobulin test (A-IAT). Fifty serum samples containing clinically significant alloantibodies and fifty samples without alloantibodies were tested. Following an acute hemolytic transfusion reaction (HTR) involving an anti-K that was not detected with LISS but was retrospectively found to be reactive with PEG, an additional 151 samples received for antibody screening were prospectively evaluated in parallel using PEG and LISS. PEG detected all clinically significant antibodies in the 50 previously tested samples, with mean reactivity scores greater than LISS or A-IAT. In the prospective study, PEG detected 35 clinically significant antibodies and 10 clinically insignificant antibodies, while LISS detected only 15 clinically significant antibodies and 33 clinically insignificant antibodies. PEG appears to increase detection of significant antibodies while decreasing detection of insignificant antibodies. PEG was therefore substituted for LISS as an enhancement medium and has been in routine use for 12 months, with no reported acute or anamnestic HTRs in 6,353 transfusions.

10.
Vox Sang ; 61(1): 18-23, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1949705

RESUMO

Septicemia is a rare complication of blood transfusion. This is probably primarily due to the use of sealed disposable containers for blood collection and the storage of red cell-containing components at 4 degrees C. However, despite these measures, septicemia due to blood transfusion continues to occur. We report here a fatal case of Yersinia enterocolitica septicemia due to a contaminated unit of red cells which was collected from an apparently healthy, asymptomatic blood donor. The organism grows at cold temperature and multiplies during storage of red blood cell-containing components. Contaminated components do not show any visible abnormalities. The possibility of transfusion-transmitted Y. enterocolitica should be considered in patients who have symptoms of sepsis or shock following transfusion.


Assuntos
Reação Transfusional , Yersiniose/microbiologia , Yersinia enterocolitica , Feminino , Humanos , Pessoa de Meia-Idade , Sorotipagem , Fatores de Tempo , Yersiniose/mortalidade , Yersinia enterocolitica/classificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA