Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
J Prosthet Dent ; 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38772783

RESUMO

STATEMENT OF PROBLEM: Additive (3-dimensional printing) and subtractive (milling) methods are digital approaches to fabricating zirconia restorations. Comparisons of their resultant fabrication accuracy and restoration fit are lacking. PURPOSE: The purpose of this systematic review and meta-analysis was to evaluate the accuracy and fit of monolithic zirconia crowns fabricated by 3-dimensional printing and milling. MATERIAL AND METHODS: The PubMed (Medline), Scopus, Embase, Web of Science, Cochrane Library, and Google Scholar databases were searched up to August 2023. Eligible records were included, and the standardized mean difference (SMD) analyzed 4 outcomes: marginal fit, intaglio fit, trueness, and precision. Publication bias was analyzed with Trim-and-fill, the Egger regression test, and Begg funnel plot. Methodological quality was rated using the QUIN tool. RESULTS: A total of 15 publications were found eligible out of the initial 6539 records. The 3-dimensional printing group demonstrated a lower marginal fit (SMD=1.46, 95% CI=[0.67, 2.26], P<.001; I2=83%, P<.001) and trueness (SMD=0.69, 95% CI=[0.20, 1.18], P=.006; I2=88%, P<.001) and a significantly higher precision (SMD=-2.19, 95% CI=[-2.90, -1.48], P<.001; I2=56%, P=.045). The intaglio fit did not differ significantly across the study groups (SMD=0.77, 95% CI=[-0.22, 1.77], P=.127; I2=87%, P<.001). CONCLUSIONS: Given the high degree of heterogeneity, it can be cautiously concluded that while 3-dimensional printing led to greater precision, the outcomes of the 2 accuracy and adaptation parameters most crucial to the longevity of the restorations-trueness and marginal fit-showed the superiority of the milling technique.

2.
J Dent Sci ; 19(2): 871-877, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38618120

RESUMO

Background/purpose: Translucent monolithic zirconia restorations have recently introduced. The purpose of this study was to evaluate the clinical behavior and the survival rate of the posterior third-generation monolithic zirconia crowns (MZCs) during three years of clinical service. Materials and methods: Twenty-four patients who needed thirty crowns were enrolled in this study. Digital impressions were made, and the crowns were milled and cemented with a resin cement. The crowns outcomes were assessed using the California Dental Association's (CDA) criteria. Gingival index (GI), plaque index (PI), and periodontal probing depth (PPD) for MZCs and contralateral natural teeth (control) were assessed. Margin index (MI) for MZCs was also assessed. Data analysis was conducted using the Wilcoxon signed-rank and the Friedman tests. Results: The 3-year survival rate was 100%. All MZCs were rated as satisfactory throughout the follow-up period, and no biological or mechanical complications were observed. No differences were recorded when GI, PI and PPD at 3-year of follow-up were compared to baseline. No differences were recorded between crowned and control teeth. The MI remained stable throughout the study period. Conclusion: The third-generation monolithic zirconia appears to be a good treatment option for the rehabilitation of posterior single teeth.

3.
J Prosthodont Res ; 68(1): 78-84, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-36990752

RESUMO

Purpose To evaluate and compare the survival, success rates, and biological and technical complications of three-unit posterior monolithic and veneered zirconia and metal-ceramic (MC) posterior fixed partial dentures (FPDs) fabricated using a digital workflow and computer-aided design and computer-aided manufacturing (CAD/CAM) over a 5-year follow-up.Methods Ninety patients in need of three-unit posterior FPDs were randomized to receive monolithic zirconia (MZ), veneered zirconia (VZ), and MC restorations (n = 30 each). Teeth preparations were scanned using an intraoral scanner, and restorations were milled and cemented with resin cement. Clinical performance and periodontal parameters were assessed at baseline and yearly up to 5 years after insertion. Data analysis was performed using the Kaplan-Meier method, Friedman test, and Wilcoxon signed-rank test with Bonferroni correction and Mann-Whitney U test.Results The 5-year survival rates of the MZ, VZ, and MC FPDs were 87%, 97%, and 100%, respectively (P = 0.04). Most complications were biological in nature. Only one MZ FPD fractured 58 months after placement. All the restorations were assessed as satisfactory at each recall. Differences were found in the gingival index score over time in the VZ and MC groups. The margin index remained stable throughout the follow-up period in both zirconia groups.Conclusions The results of this study suggest that using a digital workflow to fabricate posterior FPDs is an adequate treatment option and that monolithic zirconia could be a viable alternative to metal-ceramic or veneered zirconia. However, further long-term studies are necessary to provide stronger evidence in patients with bruxism.


Assuntos
Falha de Restauração Dentária , Planejamento de Dentadura , Humanos , Estudos Prospectivos , Fluxo de Trabalho , Cerâmica , Zircônio , Prótese Parcial Fixa , Desenho Assistido por Computador , Porcelana Dentária
4.
J Clin Med ; 12(23)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38068516

RESUMO

The immediate loading protocol has become increasingly popular due to the progressive growth in demand for a reduction in treatment times. The possibility of applying this protocol would depend on certain important factors. The application of the digital workflow mentioned in the protocol guarantees rapidity, precision, and esthetics. This report aims to describe a fully digital workflow using a dual scan impression technique to fabricate immediate fixed complete dentures (FCDs) for zygomatic and standard implants. A 58-year-old female patient requested treatment for her severely atrophic maxilla, and four unrehabilitated implants in the mandible. After proper diagnosis and planification, four zygomatic implants and two standard implants were placed. During the surgery, transmucosal abutments were placed on all implants. After suturing, the positions of the implants were recorded using a stereophotogrammetric technique, creating a standard tessellation (STL) file. In the lower arch, the second phase of the surgery was carried out: the transmucosal abutments were placed, and then the implant positions were recorded in the same way. The soft tissues were rescanned after suturing with an intraoral scanner (IOS), and all STL files were aligned to obtain the virtual final models. The pre-design after virtual modifications was aligned with the definitive models. The provisional prostheses were milled and placed after six hours after the surgery, and the definitive prostheses were placed six months after the surgery. The dual scan technique used obtained a precise fit for both the provisional and definitive FCDs. This technique might be an effective and reliable alternative for the fabrication of immediate and definitive screw-retained FCDs in a completely digital workflow. The time taken for scanning and fabrication was reduced, and the clinician's and patient's satisfaction were improved.

5.
Materials (Basel) ; 16(17)2023 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-37687747

RESUMO

The purpose of this study was to investigate the effect of low-pressure plasma on the contact angle, shear bond strength (SBS), and the failure mode of zirconia ceramic. Zirconia specimens were divided into three groups according to the surface treatment methods as follows: sandblasting with aluminum oxide (ZR-C), sandblasting with aluminum oxide and oxygen plasma (ZR-CP), and argon plasma (ZR-P). The contact angle, SBS, and surface characteristics were tested after thermocycling. Data analysis was made using the Kruskal-Wallis test and one-way analysis of variance. Plasma treatment significantly reduced the contact angle (p < 0.001) with the lowest value for the Zr-P group. An increase in oxygen and a decrease in carbon was observed on the zirconia surface in both plasma groups. For the SBS, there were significant differences among the groups (p < 0.018), the Zr-CP group showing the highest bond strength. Mixed failures were the most frequent. Plasma treatment was effective in increasing the wettability, increasing the oxygen/carbon ratio without changing zirconia surface morphology. The sandblasting plus plasma with oxygen group exhibited the highest bond strength.

6.
Rev. med. cine ; 19(3): 215-223, sep. 2023. ilus
Artigo em Espanhol | IBECS | ID: ibc-225626

RESUMO

El objetivo de este artículo es realizar un análisis de una selección de discursos empleados en el documental The End of Medicine (2022) con el fin de esclarecer la complejidad del entramado de factores imbricados en las relaciones entre humanos y no humanos en la pandemia. El cine documental es una de las principales herramientas estéticas con las cuales poder visibilizar públicamente registros de instituciones y agentes sociopolíticos ante un acontecimiento. Por ello, el artículo discurre en torno a esta obra documental como un ejercicio de comunicación social de la ciencia, al optar como metodología por la clasificación crítica y discursiva de algunos de los argumentos empleados en la misma, ofreciendo así un cartografiado de los contextos de las que se presenta la principal amenaza actual para la salud, como es la resistencia a los antibióticos. Contextos que se sostienen en entornos en los que se propician los mercados mojados, las granjas intensivas, la zoonosis o el mercado de animales salvajes. Todos ellos suponen un desafío tanto para la salud como para la gobernanza de nuestras instituciones. Si bien esta última se diluye en muchos puntos, como veremos en el artículo, como es en el caso del racismo contra comunidades asiáticas durante la pandemia. Con todo ello, este texto ofrece, gracias al documental, múltiples posibilidades de situarnos ante las complejidades de un mapa que requiere del fortalecimiento de los distintos modos de gobernanza posible para garantizar los derechos fundamentales de la ciudadanía. (AU)


The aim of this paper is to analyze a selection of discourses of the documentary film The End of Medicine (2022) in order to shed light on the complexity of the net of factors involved in the relationships among humans and non-humans during the pandemic. Documentary film is one of the main aesthetic tools with which we find proceedings of institutions and socio-political agents of an event publicly. Therefore, the article discusses this documental film as an exercise of social communication of science, with a methodology that classifies some of the arguments from a critical and discursive view. Thus offering a mapping of the contexts of what is presented as the main threat to health, such as resistance to antibiotics. Contexts that are sustained in environments in which wet markets, intensive farms, zoonosis or the wild animal market are improved. All of these pose a challenge both to health and to the governance of our institutions. Although the last one is diluted at many points, as we will see in the article, such as in the case of racism against Asian communities during the pandemic. All in all, this paper offers, thanks to the documentary film, multiple possibilities of situating ourselves in the complexities of a map that requires the strengthening of the different possible modes of governance to guarantee the fundamental rights of citizens. (AU)


Assuntos
Humanos , Pandemias , Infecções por Coronavirus/epidemiologia , Comunicação , Filmes Cinematográficos , Zoonoses
7.
BMC Oral Health ; 22(1): 449, 2022 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-36261829

RESUMO

BACKGROUND: Peri-implantitis is a usual finding but estimates of its prevalence fluctuate very much. This may be due to the wide variety of disease definitions. This systematic review aims to estimate the overall prevalence of peri-implantitis and the effect of different study designs, function times and use of probing depth on prevalence rate. METHODS: Following electronic and manual searches of the literature published from January 2005 to December 2021, data were extracted from the studies fitting the study criteria. Fifty-seven articles were included in this study. RESULTS: Prevalence of peri-implantitis was 19.53% (95% CI 12.87-26.19) at the patient-level, and 12.53% (95% CI 11.67-13.39) at the implant-level and it remains highly variable even following restriction to the clinical case definition. The use of probing depth like diagnostic criteria affected the prevalence data. CONCLUSION: The results indicate that it remains essential the identification of the diagnostic markers for more accurate disease classification.


Assuntos
Implantes Dentários , Peri-Implantite , Humanos , Peri-Implantite/epidemiologia , Peri-Implantite/etiologia , Prevalência , Projetos de Pesquisa
8.
Parasite Epidemiol Control ; 19: e00273, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36118050

RESUMO

Chagas Disease (CD), a chronic infection caused by the Trypanosoma cruzi parasite, is a Neglected Tropical Disease endemic to Latin America. With a re-emergence in Venezuela during the past two decades, the spread of CD has proved susceptible to, and inhibitable by a digital, real-time surveillance system effectuated by Citizen Scientists in communities throughout the country. The #TraeTuChipo (#BringYourKissingBug) campaign implemented in January 2020, has served as such a strategy counting on community engagement to define the current ecological distribution of CD vectors despite the absence of a functional national surveillance program. This pilot campaign collected data through online surveys, social media platforms, and/or telephone text messages. A total of 79 triatomine bugs were reported from eighteen Venezuelan states; 67 bugs were identified as Panstrongylus geniculatus, 1 as Rhodnius pictipes, 1 as Triatoma dimidiata, and 10 as Triatoma maculata. We analyzed 8 triatomine feces samples spotted from 4 Panstrongylus geniculatus which were confirmed positive by qPCR for T. cruzi . Further molecular characterization of discrete typing units (DTUs), revealed that all samples contained TcI, the most highly diverse and broadly distributed strain of T. cruzi. Moreover, analysis of the mitochondrial 12S gene revealed Myotis keaysi, Homo sapiens, and Gallus gallus as the main triatomine feeding sources. This study highlights a novel Citizen Science approach which may help improve the surveillance systems for CD in endemic countries.

9.
Clin Oral Investig ; 26(6): 4327-4335, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35142924

RESUMO

OBJECTIVES: To evaluate and to compare the clinical performance and survival rate of posterior monolithic and veneered zirconia fixed partial dentures (FPDs). MATERIAL AND METHODS: Sixty 3-unit posterior FPDs were included in the study. The patients were randomly distributed into two groups (n = 30 each) to receive either a monolithic (Zenostar T, Wieland Dental) or veneered zirconia (IPS e.max ZirCAD, Ivoclar Vivadent) FPD. Each patient received only 1 FPD. Tooth preparations were scanned (Trios 3, 3Shape), designed (Dental System 2016, 3 Shape), milled (Zenotec CAM 3.2, Wieland Dental), and cemented with a resin cement. Technical and biological outcomes and periodontal parameters were assessed. Data analysis was made using the Friedman and the Wilcoxon signed-rank tests with the Bonferroni correction and the Mann-Whitney U test. RESULTS: The survival rate at 3 years was 100% for veneered and 90% for monolithic zirconia restorations. Three monolithic zirconia FPDs were lost because of biologic complications. The main complication in the veneered zirconia FPDs was the fracture of the veneering ceramic in 4 of the veneered zirconia FPDs. No fracture of the frameworks was observed in any of the groups. All restorations were assessed as satisfactory after 3 years. No differences in periodontal parameters were observed between the groups. CONCLUSIONS: The results of this study suggest that monolithic zirconia and complete digital flow could be a viable alternative to veneered zirconia in the posterior regions. CLINICAL RELEVANCE: The monolithic zirconia restorations with a digital workflow can be a viable alternative in posterior fixed partial dentures, with good periodontal outcomes. CLINICAL TRIAL REGISTRATION NUMBER: ClinicalTrials.gov (Identifier NCT 04,879,498).


Assuntos
Porcelana Dentária , Falha de Restauração Dentária , Desenho Assistido por Computador , Facetas Dentárias , Prótese Parcial Fixa , Seguimentos , Humanos , Zircônio
10.
Materials (Basel) ; 15(2)2022 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-35057389

RESUMO

Clinical studies on the behavior of posterior translucent monolithic zirconia restorations are lacking. We assessed the clinical outcome and survival rate of posterior third-generation monolithic zirconia crowns over a 2-year period. A total of 24 patients, requiring 30 posterior full-contour restorations were selected. All abutments were scanned, and crowns were milled and cemented with a self-adhesive dual cure cement. Crowns were assessed using the California Dental Association's criteria. Gingival status was assessed by evaluating the gingival index, plaque index, periodontal probing depth of the abutments and control teeth, and the margin index of the abutment teeth. Statistical analyses were performed using the Friedman and the Wilcoxon signed-rank tests. During the 2-year follow-up, no biological or mechanical complications were observed, and the survival and success rate was 100%. All restorations ranked as satisfactory throughout the follow-up period. The gingival index and plaque index were worse at the end of the 2-year follow-up. The margin index was stable during the 2 years of clinical service. No significant differences were recorded in periodontal parameters between crowns and control teeth. Third-generation monolithic zirconia could be a reliable alternative to posterior metal-ceramic and second-generation monolithic zirconia posterior crowns.

11.
J Prosthodont ; 31(7): 606-613, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34860426

RESUMO

PURPOSE: To compare the load to fracture of cobalt-chromium (Co-Cr) 3-unit posterior fixed partial denture (FPD) frameworks manufactured by conventional and digital techniques and to evaluate the influence of the framework design on the fracture load. MATERIAL AND METHODS: Eighty 3-unit Co-Cr posterior FPD frameworks were fabricated with two designs: intermediate pontic (n = 40) and cantilever (n = 40). Each design was randomly divided into four groups (n = 10): casting, direct metal laser sintering, soft metal milling, and hard metal milling. After thermal cycling, all specimens were subjected to a 3-point bending test until fracture. Data were statistically analyzed using one-way ANOVA, Welch and Brown-Forsythe test, Ryan-Einot-Gabriel-Welsch F and Tamhane T2 post hoc test, Student's t test, and Weibull statistics (α = 0.05). RESULTS: Significant differences (p < 0.001; F = 39.59) were found among intermediate pontic frameworks (except between laser sintering and hard metal milling), and cantilevered frameworks (F = 36.75) (except between laser sintering and hard metal milling, and casting and soft metal milling). The cantilever groups showed load to fracture values significantly lower than those of the intermediate pontic (p < 0.001; F = 28.29). The Weibull statistics corroborated the results. CONCLUSIONS: Hard metal milling and laser sintered frameworks exhibited the highest load to fracture values. However, all tested frameworks demonstrated clinically acceptable load to fracture values. The framework design directly affected the fracture load, with drastically lower values in cantilevered frameworks.


Assuntos
Cromo , Tecnologia Digital , Cobalto , Desenho Assistido por Computador , Prótese Parcial Fixa , Humanos , Teste de Materiais
12.
Infect Dis Clin Pract (Baltim Md) ; 29(6): e462-e464, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34803352

RESUMO

The COVID-19 pandemic has challenged clinicians to recognize COVID-19 as one of the diagnostic explanation for common presentations, including fever, cough, and shortness of breath. Latent tuberculosis is responsible for 80% of active tuberculosis cases in the United States, and presentation can vary from asymptomatic to disseminated disease. This potential diagnosis should be thoroughly investigated in foreign-born patients in US hospitals, regardless of travel history and presenting symptoms. We report a patient diagnosed with postpartum disseminated tuberculosis with hematogenous spread to the fetus.

13.
Scand J Gastroenterol ; 56(7): 820-828, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34043920

RESUMO

OBJECTIVE: Patients with long-standing colonic inflammatory bowel disease (cIBD) are at increased risk of developing colorectal cancer (CRC). Dye-spray chromoendoscopy (DCE) with targeted biopsies is the preferred technique for surveillance of dysplasia. Virtual chromoendoscopy (VCE) are arising to improve detection rates and adherence to surveillance guidelines, although its role is not yet well defined. The purpose of this study is to assess the effectiveness of VCE with iSCAN as an alternative method for dysplasia detection in cIBD. METHODS: Retrospective case-control study with 191 patients included, 98 in the DCE (Indigo carmine) group and 93 in the VCE (iSCAN, twin-mode 1-3) group. The dysplasia detection and the exploration time were analysed. A logistic regression analysis was performed to ascertain the factors related to colonic dysplasia. RESULTS: A total of 44 dysplastic lesions were detected in 21 (11%) patients. No differences were found in the per lesion and the per patient analysis (dysplastic versus non-dysplastic). Median withdrawal time was shorter in the VCE group than in the DCE group (9 min versus 14 min; p < .001). Location of lesions in the right colon was independently associated with an increased risk for colonic dysplasia (OR = 4.04, 95%CI 1.11-14.65; p = .034) after adjusting for age at inclusion, age at diagnosis, high risk for CRC and Kudo pit pattern. CONCLUSIONS: VCE with iSCAN presents a similar diagnostic performance to conventional DCE in the detection of colonic dysplasia in patients with long-standing cIBD. Furthermore, VCE with iSCAN is a less time-consuming surveillance alternative to DCE.


Assuntos
Colite Ulcerativa , Neoplasias Colorretais , Doenças Inflamatórias Intestinais , Estudos de Casos e Controles , Colonoscopia , Corantes , Detecção Precoce de Câncer , Humanos , Estudos Retrospectivos
14.
Materials (Basel) ; 14(4)2021 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-33670544

RESUMO

The aim of this study was to investigate the load to fracture and fracture pattern of prosthetic frameworks for tooth-supported fixed partial dentures (FPDs) fabricated with different subtractive computer-aided design and computer-aided manufacturing (CAD-CAM) materials. MATERIALS AND METHODS: Thirty standardized specimens with two abutments were fabricated to receive three-unit posterior FDP frameworks with an intermediate pontic. Specimens were randomly divided into three groups (n = 10 each) according to the material: group 1 (MM)-milled metal; group 2 (L)-zirconia; and group 3 (P)-Polyetheretherketone (PEEK). The specimens were thermo-cycled and subjected to a three-point bending test until fracture using a universal testing machine (cross-head speed: 1 mm/min). Axial compressive loads were applied at the central fossa of the pontics. Data analysis was made using one-way analysis of variance, Tamhane post hoc test, and Weibull statistics (α = 0.05). RESULTS: Significant differences were observed among the groups for the fracture load (p < 0.0001). MM frameworks showed the highest fracture load values. The PEEK group registered higher fracture load values than zirconia samples. The Weibull statistics corroborated these results. The fracture pattern was different among the groups. CONCLUSIONS: Milled metal provided the highest fracture load values, followed by PEEK, and zirconia. However, all tested groups demonstrated clinically acceptable fracture load values higher than 1000 N. PEEK might be considered a promising alternative for posterior FPDs.

15.
J Prosthodont Res ; 65(3): 291-297, 2021 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-33041277

RESUMO

Purpose To evaluate the influence of intraoral and extraoral digitization systems on marginal discrepancy of monolithic lithium disilicate and monolithic zirconia computer-aided design-computer-aided manufacturing (CAD-CAM) crowns.Methods Forty standardized machined stainless steel specimens with the characteristics of a first molar were manufactured and randomly assigned to two groups (n=20 each), depending on their material: monolithic lithium disilicate ceramic (LM), and monolithic zirconia (ZM). Then, each group was subdivided into two depending on the scanning system used: intraoral scanner (IOS), and extraoral scanner (EOS). The digitization process was standardized with two methacrylate devices, one for each scanner. After scanning and manufacturing of the crowns, the marginal discrepancy was measured under a scanning electron microscope (SEM). Data analysis was made using two-way analysis of variance (ANOVA) and the effect size with Cohen's d.Results All the measurements were within the limits considered acceptable. Regardless the restorative material significant differences between scanners were observed, being the effect from low to moderate. However, no differences were observed between the scanners in either the lithium disilicate or zirconia group.Conclusions The intraoral scan showed lower marginal discrepancy than the extraoral scan in CAD-CAM monolithic crowns, but these differences were not observed in each of the ceramic systems.


Assuntos
Adaptação Marginal Dentária , Planejamento de Prótese Dentária , Cerâmica , Desenho Assistido por Computador , Coroas , Materiais Dentários , Porcelana Dentária
16.
J Prosthodont ; 30(4): 298-304, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32881181

RESUMO

PURPOSE: To evaluate the clinical performance and survival rate of posterior monolithic zirconia fixed partial dentures over a 2-year period. MATERIAL AND METHODS: A total of 20 patients, requiring 20 posterior fixed partial dentures were included in the study. Tooth preparations were scanned, and restorations were milled and cemented with a resin cement. The restorations were assessed for the quality of the surface and the color, anatomical form and marginal integrity. Periodontal status was assessed by determining the plaque index, gingival index, pocket depth, and margin index of the abutment teeth. Data were statistically analyzed using the Friedman and the Wilcoxon signed-rank tests with the Bonferroni correction. RESULTS: The survival rate at 2 years was 100%, and no biological or technical complications were observed. All restorations were assessed as satisfactory. The results obtained for gingival index and plaque index were better at 2 years follow-up, than at baseline. The margin index remained stable throughout the follow-up period. No differences in periodontal parameters were observed between abutment and control teeth. CONCLUSIONS: The high survival rate after 2 years suggest that monolithic zirconia may be an acceptable alternative to metal-ceramic and veneered zirconia restorations in the posterior region. Additional long-term, controlled studies are necessary to confirm the results.


Assuntos
Porcelana Dentária , Falha de Restauração Dentária , Prótese Parcial Fixa , Seguimentos , Humanos , Estudos Prospectivos , Fluxo de Trabalho , Zircônio
17.
J Prosthet Dent ; 125(2): 323.e1-323.e7, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33176924

RESUMO

STATEMENT OF PROBLEM: Marginal fit of zirconia restorations is an important criterion for their long-term success. However, in spite of the wide use of zirconia in dentistry, the relationship between marginal fit and low-temperature degradation from aging is unclear. PURPOSE: The purpose of this in vitro study was to compare the marginal adaptation of veneered and monolithic zirconia and metal-ceramic computer-aided design and computer-aided manufacturing (CAD-CAM) crowns before and after cementation and to evaluate the influence of artificial aging on the adaptation of zirconia crowns. MATERIAL AND METHODS: Seventy-two standardized dies were prepared to receive a posterior crown and randomly divided into 6 groups (n=12) as per the material and the presence or not of cement: metal-ceramic, veneered zirconia, and monolithic zirconia. The zirconia groups were subjected to accelerated low-temperature degradation through hydrothermal aging in an autoclave at 131 °C and 0.17 MPa for 5 and 20 hours. A scanning electron microscope with a magnification of ×1000 was used for marginal adaptation measurements, and X-ray diffraction (XRD) was used to characterize phase transformation degradation. The data were statistically analyzed using 2-way ANOVA, repeated measures ANOVA with Greenhouse-Geisser correction, and the t test (α=.05). RESULTS: No significant differences in the marginal discrepancy were recorded among the analyzed groups. The presence of cement did not influence marginal fit in any treatment group. No significant differences were observed in the marginal adaptation values before and after aging (P>.05). After 20 hours of aging, the monoclinic phase increase to 8.3% on veneered zirconia and to 3.1% on monolithic crowns. CONCLUSIONS: Monolithic and bilayer CAD-CAM zirconia crowns showed marginal gaps that were within an acceptable range of clinical discrepancy, regardless of cementation. Marginal adaptation was not influenced by aging. Low-temperature degradation did not lead to a significant transformation from the tetragonal to monoclinic phase.


Assuntos
Cimentação , Adaptação Marginal Dentária , Cerâmica , Desenho Assistido por Computador , Coroas , Porcelana Dentária , Planejamento de Prótese Dentária , Zircônio
18.
Materials (Basel) ; 13(21)2020 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-33143092

RESUMO

The precision of fit at the implant-abutment connection is an important criterion for the clinical success of restorations and implants. Several factors are involved among which are the abutment materials and manufacturing techniques. The aim of this study was to investigate the effect of two materials and methods of manufacturing implant abutments, milled titanium versus laser sintered Co-Cr, on the marginal misfit at the implant-abutment interface. Scanning electron microscopes (SEM) were used to geometrically measure the marginal vertical discrepancy of a total of 80 specimens, classified into eight categories, according to the implant system and abutment. The data were statistically analyzed by Student's paired t test, one-way and two-way ANOVA with the Bonferroni-Holm correction at the significance level of p = 0.05. Milled titanium abutments demonstrated the lowest misfit values in the implant systems analyzed. The marginal fit of all the groups was within the clinically acceptable range for implant prostheses.

19.
J Clin Exp Dent ; 12(9): e896-e901, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32994882

RESUMO

Biologically oriented preparation technique (BOPT) is a vertical preparation technique without a finish line to create a new anatomic crown with a prosthetic emergence profile. This case report describe the protocol realized digitally in a patient who required a new fixed partial denture (FPD) in the anterior esthetic zone. After time of temporary restoration, definitive conventional (CI) (double-cord retraction and vinyl polysiloxane material), and digital impression (DI) with three different intraoral scanner (IOS) (Trios®, True Definition® and iTero®) were taken. All digital impression were obtained through three different scans: temporary restoration in the mouth after healing period, prepared teeth, and temporary restoration out of the mouth. To establish which of the IOS was the most accurate, it was necessary to compare the STL files obtained from each of the IOS with the STL file of the conventional impression, which was digitized with a laboratory scanner (3Shape D800). All these STL were imported to a software (ExoCAD 2.4 Plovdiv®), and they were superimposed. To establish the difference in trueness with SC, 6 points were chosen, 3 points in teeth, and another 3 points in soft tissue. The mean measurement in terms of trueness in teeth were: STS (0,039 mm), SI (0,054 mm), STD (0,067 mm); and in soft tissue were: STS (0,051 mm), SI (0,09 mm), STD [0,236 mm]. The IOSs showed differences between them in terms of trueness, being the Trios the most accuracy IOS. Final restoration was fabricated and cemented. The patient was examined at 3, 6 and 12 months, without any type of biological or mechanical complications. Digital impression with an IOS seems to be a viable alternative to perform zirconia FPD in the BOPT tecbique. Key words:Intraoral scanners, accuracy, vertical preparation, precision, CAD-CAM, prosthodontics.

20.
Cureus ; 12(7): e9103, 2020 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-32789048

RESUMO

This case illustrates a rare, underdiagnosed disease, with a high mortality rate that is frequently misdiagnosed as acute bacterial endocarditis. Clinicians should include non-bacterial thrombotic endocarditis (NBTE) as a differential diagnosis in patients with culture-negative endocarditis, so that its underlying etiology can be further investigated.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...