Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 68(6)2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36731142

RESUMO

Objective. The radiation response of alanine is very well characterized in the MV photon energy range where it can be used to determine the dose delivered with an accuracy better than 1%, making it suitable as a secondary standard detector in cancer radiation therapy. This is not the case in the very low energy keV x-ray range where the alanine response is affected by large uncertainties and is strongly dependent on the x-ray beam energy. This motivated the study undertaken here.Approach. Alanine pellets with a nominal thickness of 0.5 mm and diameter of 5 mm were irradiated with monoenergetic x-rays at the Diamond Light Source synchrotron, to quantify their response in the 8-20 keV range relative to60Co radiation. The absorbed dose to graphite was measured with a small portable graphite calorimeter, and the DOSRZnrc code in the EGSnrc Monte Carlo package was used to calculate conversion factors between the measured dose to graphite and the absorbed dose to water delivered to the alanine pellets. GafChromic EBT3 films were used to measure the beam profile for modelling in the MC simulations.Main results. The relative responses measured in this energy range were found to range from 0.616 to 0.643, with a combined relative expanded uncertainty of 3.4%-3.5% (k= 2), where the majority of the uncertainty originated from the uncertainty in the alanine readout, due to the small size of the pellets used.Significance. The measured values were in good agreement with previously published data in the overlapping region of x-ray energies, while this work extended the dataset to lower energies. By measuring the response to monoenergetic x-rays, the response to a more complex broad-spectrum x-ray source can be inferred if the spectrum is known, meaning that this work supports the establishment of alanine as a secondary standard dosimeter for low-energy x-ray sources.


Assuntos
Alanina , Síncrotrons , Raios X , Alanina/metabolismo , Alanina/efeitos da radiação , Braquiterapia , Grafite , Método de Monte Carlo , Neoplasias/radioterapia , Radiometria/métodos , Incerteza , Humanos
2.
Phys Med Biol ; 67(6)2022 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-35240589

RESUMO

Detailed characterisation of the Roos secondary standard plane-parallel ionisation chamber has been conducted in a novel 200 MeV Very High Energy Electron (VHEE) beam with reference to the standard 12 MeV electron calibration beam used in our experimental work. Stopping-power-ratios and perturbation factors have been determined for both beams and used to calculated the beam quality correction factor using the Geant4 general purpose MC code. These factors have been calculated for a variety of charged particle transport parameters available in Geant4 which were found to pass the Fano cavity test. Stopping-power-ratios for the 12 MeV electron calibration beam quality were found to agree within uncertainties to that quoted by current dosimetry protocols. Perturbation factors were found to vary by up-to 4% for the calibration beam depending on the parameter configuration, compared with only 0.8% for the VHEE beam. Beam quality correction factors were found to describe an approximately 10% lower dose than would be originally calculated if a beam quality correction were not accounted for. Moreover, results presented here largely resolve unphysical chamber measurements, such as collection efficiencies greater than 100%, and assist in the accurate determination of absorbed dose and ion recombination in secondary standard ionisation chambers.

3.
Phys Med Biol ; 66(24)2021 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-34844225

RESUMO

Objective.The boundary crossing algorithm available in Geant4 10.07-p01 general purpose Monte Carlo code has been investigated for a 12 and 200 MeV electron source by the application of a Fano cavity test.Approach.Fano conditions were enforced through all simulations whilst varying individual charged particle transport parameters which control particle step size, ionisation and single scattering.Main Results.At 12 MeV, Geant4 was found to return excellent dose consistency within 0.1% even with the default parameter configurations. The 200 MeV case, however, showed significant consistency issues when default physics parameters were employed with deviations from unity of more than 6%. The effect of the inclusion of nuclear interactions was also investigated for the 200 MeV beam and was found to return good consistency for a number of parameter configurations.Significance.The Fano test is a necessary investigation to ensure the consistency of charged particle transport available in Geant4 before detailed detector simulations can be conducted.

4.
Sci Rep ; 10(1): 9089, 2020 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-32493952

RESUMO

High dose-rate radiotherapy, known as FLASH, has been shown to increase the differential response between healthy and tumour tissue. Moreover, Very High Energy Electrons (VHEEs) provide more favourable dose distributions than conventional radiotherapy electron and photon beams. Plane-parallel ionisation chambers are the recommended secondary standard systems for clinical reference dosimetry of electrons, therefore chamber response to these high energy and high dose-per-pulse beams must be well understood. Graphite calorimetry, the UK primary standard, has been employed to measure the dose delivered from a 200 MeV pulsed electron beam. This was compared to the charge measurements of a plane-parallel ionisation chamber to determine the absolute collection efficiency and infer the ion recombination factor. The dose-per-pulse measured by the calorimeter ranged between 0.03 Gy/pulse and 5.26 Gy/pulse, corresponding to collection efficiencies between 97% and 4%, respectively. Multiple recombination models currently available have been compared with experimental results. This work is directly applicable to the development of standard dosimetry protocols for VHEE radiotherapy, FLASH radiotherapy and other high dose-rate modalities. However, the use of secondary standard ionisation chambers for the dosimetry of high dose-per-pulse VHEEs has been shown to require large corrections for charge collection inefficiency.

5.
Sci Rep ; 9(1): 10837, 2019 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-31346184

RESUMO

The increased inertia of very high-energy electrons (VHEEs) due to relativistic effects reduces scattering and enables irradiation of deep-seated tumours. However, entrance and exit doses are high for collimated or diverging beams. Here, we perform a study based on Monte Carlo simulations of focused VHEE beams in a water phantom, showing that dose can be concentrated into a small, well-defined volumetric element, which can be shaped or scanned to treat deep-seated tumours. The dose to surrounding tissue is distributed over a larger volume, which reduces peak surface and exit doses for a single beam by more than one order of magnitude compared with a collimated beam.


Assuntos
Simulação por Computador , Dosagem Radioterapêutica , Radioterapia/métodos , Elétrons , Método de Monte Carlo
6.
Sci Rep ; 7(1): 2399, 2017 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-28546551

RESUMO

Raman amplification arising from the excitation of a density echelon in plasma could lead to amplifiers that significantly exceed current power limits of conventional laser media. Here we show that 1-100 J pump pulses can amplify picojoule seed pulses to nearly joule level. The extremely high gain also leads to significant amplification of backscattered radiation from "noise", arising from stochastic plasma fluctuations that competes with externally injected seed pulses, which are amplified to similar levels at the highest pump energies. The pump energy is scattered into the seed at an oblique angle with 14 J sr-1, and net gains of more than eight orders of magnitude. The maximum gain coefficient, of 180 cm-1, exceeds high-power solid-state amplifying media by orders of magnitude. The observation of a minimum of 640 J sr-1 directly backscattered from noise, corresponding to ≈10% of the pump energy in the observation solid angle, implies potential overall efficiencies greater than 10%.

7.
Phys Med Biol ; 59(19): 5811-29, 2014 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-25207591

RESUMO

Very high energy electrons (VHEE) in the range from 100-250 MeV have the potential of becoming an alternative modality in radiotherapy because of their improved dosimetry properties compared with MV photons from contemporary medical linear accelerators. Due to the need for accurate dosimetry of small field size VHEE beams we have performed dose measurements using EBT2 Gafchromic® film. Calibration of the film has been carried out for beams of two different energy ranges: 20 MeV and 165 MeV from conventional radio frequency linear accelerators. In addition, EBT2 film has been used for dose measurements with 135 MeV electron beams produced by a laser-plasma wakefield accelerator. The dose response measurements and percentage depth dose profiles have been compared with calculations carried out using the general-purpose FLUKA Monte Carlo (MC) radiation transport code. The impact of induced radioactivity on film response for VHEEs has been evaluated using the MC simulations. A neutron yield of the order of 10(-5) neutrons cm(-2) per incident electron has been estimated and induced activity due to radionuclide production is found to have a negligible effect on total dose deposition and film response. Neutron and proton contribution to the equivalent doses are negligible for VHEE. The study demonstrates that EBT2 Gafchromic film is a reliable dosimeter that can be used for dosimetry of VHEE. The results indicate an energy-independent response of the dosimeter for 20 MeV and 165 MeV electron beams and has been found to be suitable for dosimetry of VHEE.


Assuntos
Simulação por Computador , Elétrons , Dosimetria Fotográfica/métodos , Método de Monte Carlo , Aceleradores de Partículas , Imagens de Fantasmas , Radiometria/instrumentação , Calibragem , Dosimetria Fotográfica/instrumentação , Humanos , Nêutrons , Fótons/uso terapêutico , Prótons , Radiometria/métodos , Dosagem Radioterapêutica
8.
Med Phys ; 39(6Part17): 3813-3814, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28517464

RESUMO

PURPOSE: Progress in the development of compact high-energy pulsed laser- plasma wakefield accelerators is opening up the potential for using Very High Energy Electron (VHEEs) beams in the range of 150 - 250 MeV for biomedical studies. Initial experiments using VHEE for this purpose have been carried out using the ALPHA-X laser-plasma wakefield accelerator beam line at the University of Strathclyde, Glasgow, UK. The purpose of this investigation is to use Monte Carlo simulations to plan experiments and compare with characterization of the interaction of the VHEE beam using a dosimeter. METHODS: An experiment using the VHEE beam to irradiate a muscle-equivalent BANG polymer gel dosimeter has been carried out. Simulations have been used to prepare for the experiments. These were undertaken using the expected average energy for a pulse set and an energy spread approximated by Gaussian distribution. The model was implemented in FLUKA Monte Carlo code with follow up modeling using the Geant4 toolkit. The results have been compared with 1mm̂3 voxel laser CT based measurements of the dose deposited in the BANG dosimeter and with measurement of the induced radioactivity. RESULTS: The results of the measured dose from induced radioactivity have been compared with data from the FLUKA simulations. The beam model based on an average energy of particles in irradiation gives an acceptable estimate of the induced radioactivity and the dose deposited in the BANG dosimeter. Comparison with the dosimeter scanned profiles shows that the structure of the spectra of VHEE beams in the experiment and secondary scattered particles in the beam line should be accounted for in any model. Such model description of the VHEE beam for the ALPHA-X beam line has been developed. CONCLUSIONS: Monte Carlo simulations using the FLUKA code is an efficient way to plan a VHEE experiment and analyze data from measurements.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...