Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 6709, 2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-37185591

RESUMO

Particle therapy (PT) used for cancer treatment can spare healthy tissue and reduce treatment toxicity. However, full exploitation of the dosimetric advantages of PT is not yet possible due to range uncertainties, warranting development of range-monitoring techniques. This study proposes a novel range-monitoring technique introducing the yet unexplored concept of simultaneous detection and imaging of fast neutrons and prompt-gamma rays produced in beam-tissue interactions. A quasi-monolithic organic detector array is proposed, and its feasibility for detecting range shifts in the context of proton therapy is explored through Monte Carlo simulations of realistic patient models and detector resolution effects. The results indicate that range shifts of [Formula: see text] can be detected at relatively low proton intensities ([Formula: see text] protons/spot) when spatial information obtained through imaging of both particle species are used simultaneously. This study lays the foundation for multi-particle detection and imaging systems in the context of range verification in PT.


Assuntos
Terapia com Prótons , Humanos , Terapia com Prótons/métodos , Diagnóstico por Imagem , Prótons , Raios gama , Dosagem Radioterapêutica , Método de Monte Carlo , Imagens de Fantasmas
2.
ACS Omega ; 6(35): 22643-22654, 2021 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-34514236

RESUMO

The elemental composition has been extensively used to characterize wine and to find correlations with environmental and winemaking factors. Although X-ray fluorescence (XRF) techniques offer many advantages, they have been rarely used for wine analysis. Here, we show the comparison of wine elemental composition results obtained by total reflection X-ray fluorescence (TXRF) and energy dispersive X-ray fluorescence (EDXRF) for elements K, Ca, Mn, Fe, Cu, Zn, Br, Rb, and Sr. The results obtained by TXRF and EDXRF have been additionally verified by inductively coupled plasma-mass spectrometry. The important analytical features of XRF techniques in wine science have been described, the preservation of volatile elements (e.g., Br) being one of their main advantages. In addition, we have shown that XRF techniques offer an optimal analytical approach for building large data sets containing highly reliable and reproducible results of elemental abundances in wines, corresponding soils, and grape juice. Such data sets are especially important for the geographic authentication of wine. This has been shown for 37 Austrian and Croatian wines collected together with respective soils from selected wine regions. The element abundances in soil reflect in a large portion in grape juice and finished wine suggesting that the contribution of the soil, that is, the plant uptake capacity expressed as c i(wine)/c i(soil) concentration factors, can be a highly discriminating factor for wine fingerprinting. This indeed has been proved in the present study in comparison to discrimination based only on wine element abundances. We have identified Fe, Zn, Br, Rb, and Sr as the best discriminator elements for the geographical authentication of wine. The study opens a new perspective in extending the application of XRF techniques as a cost-effective analytical tool for creating large databases of soil, grape juice, and wine element abundances for the evaluation of soil characteristics and other environmental parameters on wine composition.

3.
J Hazard Mater ; 403: 123613, 2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-32814242

RESUMO

Red mud (RM) contains large quantities of microscale particles < 1 µm and high concentrations of potentially toxic elements. In this research, we have used two types of RM of similar chemical properties but containing different quantities of micro-particles, to test whether their size plays a role in the uptake of chemical elements by earthworm Eisenia fetida. Earthworms were exposed for seven days to artificial soils (prepared in the laboratory following a protocol) amended with increasing quantities of RM. Mortality of 86 % occurred when earthworms were exposed to amended soil containing 46 % of particles below 1 µm. Surprisingly, tissue analyses have shown decreased concentrations of metals instead of the expected toxic effect. SEM analysis revealed that micro-particles strongly adhere to the earthworm epidermis putting them under the large stress. Micro-particles in RM clog their minute dermal pores of 90 nm-735 nm in diameter, which size depends on whether the earthworm's body is contracted or stretched. Strong adhesion of micro-particles to earthworms' epidermis and blockage of their microsize pores prevented normal dermal respiration and absorption of chemical elements through their epithelium resulting in a decrease of most measured metals, especially essential elements potassium, calcium and iron, followed by the lethal outcomes.


Assuntos
Oligoquetos , Poluentes do Solo , Animais , Bioacumulação , Solo , Poluentes do Solo/análise , Poluentes do Solo/toxicidade
4.
Sci Rep ; 8(1): 4925, 2018 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-29563507

RESUMO

The prospecting activities for finding new rare earth elements (REE) sources have increased greatly in recent years. One of the main discoveries was announced in 2011 by Japanese researchers who found large quantities of REE on the ocean seafloor at the sea depths greater than 4,000 m. The classic approach to investigate REE in deep sea sediments is to obtain sediment samples by drilling that is followed by laborious laboratory analysis. This is very expensive, time consuming and not appropriate for exploring vast areas. In order to efficiently explore the ocean floor for REE deposits, the further development of affordable sensors is needed. Here, we propose two nuclear techniques for exploring REE in surface deep sea sediments: i) Passive measurement of lutetium-176 radioactivity, appropriate if long-term in-situ measurements are possible, and ii) The use of the neutron sensor attached to a remotely operated vehicle for rapid in-situ measurement of gadolinium by thermal neutron-capture. Since concentrations of lutetium and gadolinium show strong linear correlation to the total REE concentrations in deep sea sediments, it is possible to deduce the total REE content by measuring Lu or Gd concentrations only.

5.
Appl Radiat Isot ; 70(7): 1070-4, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22221463

RESUMO

A multi-sensor system was evaluated for the determination of barrel content with regard to eventual pollution hazards. The proposed system is able to investigate (in situ) the interior of a barrel filled with various unknown substances ranging from chemical and radioactive waste, raw sewage sludge, municipal incinerator ashes to common household trash. The crucial part of the system is a neutron sensor, which enables the identification of substance content without actually opening the barrel at all. A comparative laboratory test with the 3″×3″ and 5″×5″×10″ NaI(Tl) gamma ray detectors was made after which 3″×3″ detector was selected and incorporated in the submarine called "Surveyor". A field test was made in the Croatian Adriatic coast on the island Losinj. Field tests show that the commercial system utilizing the described method could be constructed for barrel inspection regardless of the measurement environment (underwater, on land, dumping site, isolated location, etc.).

6.
Appl Radiat Isot ; 68(4-5): 888-92, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19833524

RESUMO

Once the presence of the anomaly on the bottom of the shallow coastal sea water has been confirmed it is necessary to establish if it contains explosive or chemical warfare charge. We propose that this be performed by using neutron sensor installed within an underwater vessel. When positioned above the object, or to its side, the system can inspect the object for the presence of the threat materials by using alpha particle tagged neutrons from the sealed tube d+t neutron generator.


Assuntos
Substâncias para a Guerra Química/análise , Substâncias Explosivas/análise , Análise de Ativação de Nêutrons/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Nêutrons , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Appl Radiat Isot ; 61(1): 73-9, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15145441

RESUMO

Measurements of characteristic gamma ray spectra resulting from A(n, n'gamma)A reactions induced by 14 eV neutrons on different bulk samples (graphite, water, melamin) were performed. Of particular importance are results of experiments with objects buried in the soil. It has been shown that samples of graphite can be identified when buried under 10 m of soil. NaI(Tl) and BaF(2) scintilators were used as gamma ray detectors. Background radiation was reduced by the associated alpha particle technique.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...