Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Drug Metab Pharmacokinet ; 51: 100519, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37393739

RESUMO

The purpose of this study was to elucidate the lack of supersaturation behavior in the dissolution profile of prazosin hydrochloride (PRZ-HCl) in the compendial dissolution test. The equilibrium solubility was measured by a shake-flask method. Dissolution tests were performed by a compendial paddle method with a phosphate buffer solution (pH 6.8, 50 mM phosphate). The solid form of the residual particles was identified by Raman spectroscopy. In the pH range below 6.5, the equilibrium solubility in phosphate buffer was lower than that in the unbuffered solutions (pH adjusted by HCl and NaOH). Raman spectra showed that the residual solid was a phosphate salt of PRZ. In the pH range above 6.5, the pH-solubility profiles in the phosphate buffer solutions and the unbuffered solutions were the same. The residual solid was a PRZ freebase (PRZ-FB). In the dissolution test, PRZ-HCl particles first changed to a phosphate salt within 5 min, then gradually changed to PRZ-FB after several hours. Since the intestinal fluid is buffered by the bicarbonate system in vivo, the dissolution behavior in vivo may not be properly evaluated using a phosphate buffer solution. For drugs with a low phosphate solubility product, it is necessary to consider this aspect.


Assuntos
Bicarbonatos , Fosfatos , Soluções Tampão , Concentração de Íons de Hidrogênio , Solubilidade , Bicarbonatos/química , Fosfatos/química
2.
ADMET DMPK ; 7(3): 183-195, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-35350659

RESUMO

The purpose of the present study was to harmonize the protocol of equilibrium solubility measurements for poorly water-soluble drugs to lower inter-laboratory variance. The "mandatory" and "recommended" procedures for the shake-flask method were harmonized based on the knowledge and experiences of each company and information from the literature. The solubility of model drugs was measured by the harmonized protocol (HP) and the non-harmonized proprietary protocol of each company (nonHP). Albendazole, griseofulvin, dipyridamole, and glibenclamide were used as model drugs. When using the nonHP, the solubility values showed large inter-laboratory variance. In contrast, inter-laboratory variance was markedly reduced when using the HP.

3.
Anal Sci ; 29(1): 107-12, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23303094

RESUMO

The preparation of cinchonidine (CCND) nanocrystals and their immobilization onto the inner surface of a fused silica capillary was investigated for use in the enantioseparation by capillary electrochromatography. The CCND nanocrystals were prepared by an emulsion method that utilizes crystal growth in an oil-in-water emulsion without a stabilizer. As a result, white-colored aqueous dispersions of organic nanoparticles were obtained. SEM images showed that the prepared CCND nanocrystals were from 300 to 700 nm in size. When the obtained dispersion was introduced into a poly(diallyldimethylammonium chloride) (PDDAC) coated capillary, the nanocrystals were strongly adsorbed onto the inner surface due to an electrostatic interaction between cationic PDDAC and the negatively charged organic nanocrystals. In CCND nanocrystals coated capillary, CEC enantioseparations of racemic amino acids were successfully achieved. The reproducibilities of the detection times were acceptable with a relative standard deviation of less than 7%, indicating that stable nanocrystal coating could be obtained by our proposed method.


Assuntos
Aminoácidos/isolamento & purificação , Eletrocromatografia Capilar/métodos , Alcaloides de Cinchona/química , Nanopartículas/química , Polietilenos/química , Compostos de Amônio Quaternário/química , Dióxido de Silício/química , Adsorção , Aminoácidos/química , Emulsões , Tamanho da Partícula , Eletricidade Estática , Estereoisomerismo , Propriedades de Superfície , Ultrassom
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...