Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Oxf Med Case Reports ; 2024(7): omae075, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39040533

RESUMO

Stent fracture is one of the complications of drug-eluting stent implantation. An 84-year-old man underwent coronary angiography for unstable angina. He had diffuse severe stenosis and calcified plaque in the left anterior descending artery and underwent percutaneous coronary intervention (PCI) in the left anterior descending artery for severe stenosis with chest pain. Thereafter, two subsequent stent fractures occurred, so the patient underwent another PCI to cover them. However, a stent fracture was found again one year later. The patient was asymptomatic and PCI was avoided due to the risk of further stent fracture. When a stent fracture occurs, it is important to provide appropriate treatment according to the anatomical findings of the vessel, symptoms and the presence of ischemia.

2.
J Clin Med ; 13(5)2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38592259

RESUMO

Background: Minimally invasive mitral valve surgery (MIC-MVS) has been established as preferred treatment of mitral regurgitation (MR), but mitral transcatheter edge-to-edge valve repair (M-TEER) is routinely performed in patients at high surgical risk and is increasingly performed in intermediate risk patients. Methods: From 2010 to 2021, we performed 723 M-TEER and 123 isolated MIC-MVS procedures. We applied a sensitivity analysis by matching age, left ventricular ejection fraction (LVEF), EuroSCORE II and etiology of MR. Results: Baseline characteristics showed significant differences in the overall cohort (p < 0.01): age 78.3 years vs. 61.5 years, EuroSCORE II 5.5% vs. 1.3% and LVEF 48.4% vs. 60.4% in M-TEER vs. MIC-MVS patients. Grade of MR at discharge was moderate/severe in 24.5% (171/697) in M-TEER vs. 6.5% (8/123) in MIC-MVS (p < 0.01). One-year survival was 91.5% (552/723) in M-TEER vs. 97.6% (95/123) in MIC-MVS (p = 0.04). A matching with 49 pairs (n = 98) showed comparable survival during follow-up, but a numerically higher mean mitral valve gradient of 4.1 mmHg (95% CI: 3.6-4.6) vs. 3.4 mmHg (95% CI: 3.0-3.8) in M-TEER (p = 0.04). Conclusions: Patients undergoing M-TEER had lower one-year survival than MIC-MVS, but differences disappeared after matching. Reduction in MR was less effective in M-TEER patients and postprocedural mitral valve gradients were higher.

3.
EuroIntervention ; 20(8): e487-e495, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38629416

RESUMO

BACKGROUND: Data on the likelihood of left ventricle (LV) recovery in patients with severe LV dysfunction and severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) and its prognostic value are limited. AIMS: We aimed to assess the likelihood of LV recovery following TAVI, examine its association with midterm mortality, and identify independent predictors of LV function. METHODS: In our multicentre registry of 17 TAVI centres in Western Europe and Israel, patients were stratified by baseline LV function (ejection fraction [EF] >/≤30%) and LV response: no LV recovery, LV recovery (EF increase ≥10%), and LV normalisation (EF ≥50% post-TAVI). RESULTS: Our analysis included 10,872 patients; baseline EF was ≤30% in 914 (8.4%) patients and >30% in 9,958 (91.6%) patients. The LV recovered in 544 (59.5%) patients, including 244 (26.7%) patients whose LV function normalised completely (EF >50%). Three-year mortality for patients without severe LV dysfunction at baseline was 29.4%. Compared to this, no LV recovery was associated with a significant increase in mortality (adjusted hazard ratio 1.32; p<0.001). Patients with similar LV function post-TAVI had similar rates of 3-year mortality, regardless of their baseline LV function. Three variables were associated with a higher likelihood of LV recovery following TAVI: no previous myocardial infarction (MI), estimated glomerular filtration rate >60 mL/min, and mean aortic valve gradient (mAVG) (expressed either as a continuous variable or as a binary variable using the standard low-flow, low-gradient aortic stenosis [AS] definition). CONCLUSIONS: LV recovery following TAVI and the extent of this recovery are major determinants of midterm mortality in patients with severe AS and severe LV dysfunction undergoing TAVI. Patients with no previous MI and those with an mAVG >40 mmHg show the best results following TAVI, which are at least equivalent to those for patients without severe LV dysfunction. (ClinicalTrials.gov: NCT04031274).


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Esquerda , Humanos , Valva Aórtica/cirurgia , Ventrículos do Coração , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Estudos Multicêntricos como Assunto , Estudos Clínicos como Assunto
4.
J Am Heart Assoc ; 13(6): e033233, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38497463

RESUMO

BACKGROUND: Nonobstructive general angioscopy (NOGA) can identify vulnerable plaques in the aortic lumen that serve as potential risk factors for cardiovascular events such as embolism. However, the association between computed tomography (CT) images and vulnerable plaques detected on NOGA remains unknown. METHODS AND RESULTS: We investigated 101 patients (67±11 years; women, 13.8%) who underwent NOGA and contrast-enhanced CT before or after 90 days in our hospital. On CT images, the aortic wall thickness, aortic wall area (AWA), and AWA in the vascular area were measured at the thickest point from the 6th to the 12th thoracic vertebral levels. Furthermore, the association between these measurements and the presence or absence of NOGA-derived aortic plaque ruptures (PRs) at the same vertebral level was assessed. NOGA detected aortic PRs in the aortic lumens at 145 (22.1%) of the 656 vertebral levels. The presence of PRs was significantly associated with greater aortic wall thickness (3.3±1.7 mm versus 2.1±1.2 mm), AWA (1.33±0.68 cm2 versus 0.89±0.49 cm2), and AWA in the vascular area (23.2%±9.3% versus 17.2%±7.6%) (P<0.001 for all) on the CT scans compared with the absence of PRs. The frequency of PRs significantly increased as the aortic wall thickness increased. Notably, a few NOGA-derived PRs were detected on CT in near-normal intima. CONCLUSIONS: The presence of NOGA-derived PRs was strongly associated with increased aortic wall thickness, AWA, and AWA in the vascular area, measured using CT. NOGA can detect PRs in the intima that appear almost normal on CT scans.


Assuntos
Tomografia Computadorizada Multidetectores , Placa Aterosclerótica , Humanos , Feminino , Angioscopia/métodos , Aorta Torácica , Aorta
5.
Clin Res Cardiol ; 113(1): 1-10, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36645506

RESUMO

BACKGROUND: Transcatheter mitral valve replacement (TMVR) has emerged as alternative to transcatheter edge-to-edge repair (TEER) for treatment of mitral regurgitation (MR); however, the role of TMVR with the Tendyne system among established treatments of MR is not well defined. We assessed characteristics and outcomes of patients treated with the Tendyne system in the current clinical practice. METHODS: We reviewed patients who underwent cardiac computed tomography and were judged eligible for the Tendyne system. RESULTS: A total of 63 patients were eligible for TMVR with the Tendyne system. Of these, 17 patients underwent TMVR, and 46 were treated by TEER. Patients treated with the Tendyne system were more likely to have a high transmitral pressure gradient and unsuitable mitral valve morphology for TEER than those treated with TEER. TMVR with the Tendyne system reduced the severity of MR to less than 1 + in 94.1% of the patients at discharge and achieved a greater reduction in left ventricular (LV) end-diastolic volume at the 30-day follow-up compared with TEER. In contrast, patients treated with the Tendyne system had a higher 30-day mortality than those treated with TEER, while the mortality between 30 days and one year was comparable between Tendyne and TEER. CONCLUSIONS: Among patients eligible for the Tendyne system, approximately a quarter of the patients underwent TMVR with the Tendyne system, which led substantial reduction of MR and LV reverse remodeling than TEER. In contrast, the 30-day mortality rate was higher after TMVR with the Tendyne compared to TEER.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/métodos , Resultado do Tratamento , Insuficiência da Valva Mitral/cirurgia
6.
Clin Res Cardiol ; 113(1): 58-67, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37178161

RESUMO

BACKGROUND: Malnutrition is associated with adverse outcomes in patients with aortic stenosis. The Triglycerides × Total Cholesterol × Body Weight Index (TCBI) is a simple scoring model to evaluate the status of nutrition. However, the prognostic relevance of this index in patients undergoing transcatheter aortic valve replacement (TAVR) is unknown. This study aimed to evaluate the association of the TCBI with clinical outcomes in patients undergoing TAVR. METHODS: A total of 1377 patients undergoing TAVR were evaluated in this study. The TCBI was calculated by the formula; triglyceride (mg/dL) × total cholesterol (mg/dL) × body weight (kg)/1000. The primary outcome was all-cause mortality within 3 years. RESULTS: Patients with a low TCBI, based on a cut-off value of 985.3, were more likely to have elevated right atrial pressure (p = 0.04), elevated right ventricular pressure (p < 0.01), right ventricular systolic dysfunction (p < 0.01), tricuspid regurgitation ≥ moderate (p < 0.01). Patients with a low TCBI had a higher cumulative 3-year all-cause (42.3% vs. 31.6%, p < 0.01; adjusted HR 1.36, 95% CI 1.05-1.77, p = 0.02) and non-cardiovascular mortality (15.5% vs. 9.1%, p < 0.01; adjusted HR 1.95, 95% CI 1.22-3.13, p < 0.01) compared to those with a high TCBI. Adding a low TCBI to EuroSCORE II improved the predictive value for 3-year all-cause mortality (net reclassification improvement, 0.179, p < 0.01; integrated discrimination improvement, 0.005, p = 0.01). CONCLUSION: Patients with a low TCBI were more likely to have right-sided heart overload and exhibited an increased risk of 3-year mortality. The TCBI may provide additional information for risk stratification in patients undergoing TAVR.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Avaliação Nutricional , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Peso Corporal , Colesterol , Valva Aórtica/cirurgia , Índice de Gravidade de Doença , Fatores de Risco
7.
Clin Res Cardiol ; 113(1): 156-167, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37792020

RESUMO

BACKGROUND: Obesity and underweight represent classical risk factors for outcome in patients treated for cardiovascular disease. This study describes the impact of different body mass index (BMI) categories on 1-year clinical outcome in patients with tricuspid regurgitation (TR) undergoing transcatheter-edge-to-edge repair (TEER). METHODS: We analyzed 211 consecutive patients (age 78.3 ± 7.2 years, 55.5% female, median EuroSCORE II 9.6 ± 6.7) with tricuspid regurgitation undergoing TEER from June 2015 until May 2021. Patients were prospectively enrolled in our single center registry and were retrospectively analyzed. Patients were stratified according to body mass index (BMI) into 4 groups: BMI < 20 kg/m2 (underweight), BMI 20.0 to < 25.0 kg/m2 (normal weight), BMI 25.0 to > 30.0 kg/m2 (overweight) and BMI ≥ 30 kg/m2 (obese). RESULTS: Kaplan-Meier survival curves demonstrated inferior survival for underweight and obese patients, but comparable outcomes for normal and overweight patients (global log rank test, p < 0.01). Cardiovascular death was significantly higher in underweight patients compared to the other groups (24.1% vs. 7.0% vs. 6.3% vs. 6.4%; p < 0.01). Over all, there were comparable rates of bleeding, stroke and myocardial infarction. Multivariable Cox regression analysis (adjusted for age, gender, coronary artery disease, chronic obstructive pulmonary disease, tricuspid annular plane systolic excursion, left-ventricular ejection fraction) confirmed underweight (HR 3.88; 95% CI 1.64-7.66; p < 0.01) and obesity (HR 3.24; 95% CI 1.37-9.16; p < 0.01) as independent risk factors for 1-year all-cause mortality. CONCLUSIONS: Compared to normal weight and overweight patients, obesity and underweight patients undergoing TEER display significant higher 1-year all-cause mortality.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Índice de Massa Corporal , Sobrepeso , Volume Sistólico , Estudos Retrospectivos , Magreza , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Função Ventricular Esquerda , Obesidade
8.
J Cardiovasc Comput Tomogr ; 18(1): 26-32, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38105119

RESUMO

BACKGROUND: The role of assessment of mitral annular calcification (MAC) using cardiac computed tomography (CCT) in mitral transcatheter edge-to-edge repair (TEER) remains unclear. The aim of this study was to investigate the association of MAC assessed by CCT with procedural and clinical outcomes in patients undergoing TEER. METHODS: We retrospectively analyzed 275 patients who underwent pre-procedural CCT prior TEER. Mitral calcium volume (MCV) and MAC score were measured by CCT. Functional procedural success was defined as residual mitral regurgitation of ≤2+ with mean transmitral gradient of <5 â€‹mmHg at discharge. All-cause mortality within two years after TEER was collected. RESULTS: MAC was present in 115 of 275 patients (41.8 %). The median MCV was 198 â€‹mm3 (interquartile range [IQR]: 84 to 863 â€‹mm3), and the median MAC score was 3 (IQR: 2 to 4). Higher MCV and MAC score were inversely related to the rate of functional procedural success, independently of anatomical features of mitral valve. Patients with moderate/severe MAC, defined as MAC score of ≥4, had a lower rate of functional procedural success than those without MAC (56.1 â€‹% vs. 81.3 â€‹%; p â€‹= â€‹0.002). Moreover, higher MCV and MAC score were associated with a higher risk of all-cause mortality within two years, irrespective of baseline characteristics and functional procedural success. CONCLUSIONS: The presence and burden of MAC assessed by CCT were associated with procedural and clinical outcomes in patients undergoing TEER. The CCT-based assessment of MAC may improve patient selection for TEER.


Assuntos
Calcinose , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Valor Preditivo dos Testes , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Tomografia
9.
Front Cardiovasc Med ; 10: 1266767, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38054091

RESUMO

Background: This study aimed to examine the clinical role of non-gated computed tomography (CT) in ruling out fatal chest pain in patients with non-ST-elevation acute coronary syndrome (NSTE-ACS), with a focus on the time of arrival at the hospital to coronary angiography (CAG) and peak creatine kinase (CK) levels. Methods: We retrospectively examined 196 NSTE-ACS patients who were admitted with urgently diagnosed NSTE-ACS and underwent percutaneous coronary intervention between March 2019 and October 2022. The patients were divided into three groups, namely, non-CT group, CT and defect- group, and CT and defect+ group, based on whether they underwent a CT scan and the presence or absence of perfusion defects on the CT image. Results: After the initial admission for NSTE-ACS, 40 patients (20.4%) underwent non-gated CT prior to CAG. Among these 40 patients, 27 had a perfusion defect on the CT scan. The incidence of contrast-induced nephropathy was not different among the three groups. The CT and defect+ group had a shorter arrival-to-CAG time than that of the non-CT group. In NSTE-ACS patients with elevated CK levels, the CT and defect+ group had lower peak CK levels than those in the non-CT group. Conclusion: NSTE-ACS patients with perfusion defects on non-gated CT had a shorter time from arrival to CAG, which might be associated with a lower peak CK. Non-gated CT might be useful for early diagnosis and early revascularization in the clinical setting of NSTE-ACS.

11.
J Clin Med ; 12(8)2023 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-37109312

RESUMO

Before the development of transcatheter interventions, patients with mitral regurgitation (MR) and high surgical risk were often conservatively treated and subject to poor prognoses. We aimed to assess the therapeutic approaches and outcomes in the contemporary era. The study participants were consecutive high-risk MR patients from April 2019 to October 2021. Among the 305 patients analyzed, 274 (89.8%) underwent mitral valve interventions, whereas 31 (10.2%) received medical therapy alone. Of the interventions, transcatheter edge-to-edge mitral repair (TEER) was the most frequent (82.0% of overall), followed by transcatheter mitral valve replacement (TMVR) (4.6%). In patients treated with medical therapy alone, non-optimal morphologies for TEER and TMVR were shown in 87.1% and 65.0%, respectively. Patients undergoing mitral valve interventions experienced less frequent heart failure (HF) rehospitalization compared to those with medical therapy alone (18.2% vs. 42.0%, p < 0.01). Mitral valve intervention was associated with a lower risk of HF rehospitalization (HR 0.36 [0.18-0.74]) and an improved New York Heart Association class (p < 0.01). Most high-risk MR patients can be treated with mitral valve interventions. However, approximately 10% remained on medical therapy alone and were considered as unsuitable for current transcatheter technologies. Mitral valve intervention was associated with a lower risk of HF rehospitalization and improved functional status.

13.
Cardiovasc Revasc Med ; 49: 42-46, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36609100

RESUMO

BACKGROUND: Recently, the Chronic Kidney Disease-Epidemiology Collaboration working group has published new formulas for race-independent estimation of glomerular filtration rate (GFR). We investigated the old and new eGFR equations in patients transcatheter aortic valve implantation (TAVI). METHODS: We conducted a retrospective analysis based on the data from a prospective registry of patients who underwent TAVI from January 2008 to May 2019. The primary endpoint was 30-day mortality after TAVI, and the secondary endpoints included one- and three-year mortality. RESULTS: In total, 1792 patients undergoing TAVI were included in the present analysis. The thirty-day mortality was 4.6 % (95 % CI 3.8-5.7 %), and the one- and three-year mortality were 17.5 % (95 % CI 15.7-19.4 %) and 34.4 % (95 % CI 32.0-37.0 %). After the application of the new eGFR formula, 12.0 % of patients were reclassified within the GFR category in CKD, while 13.2 % of patients were reclassified within the GFR categories of the EuroSCORE II. Hazard ratios for 30-day, one-year, and three-year mortality increased after introduction of the new creatine-based eq. (1.51, 1.52, 1.49 vs. 1.87, 1.79, 1.74, respectively). Compared to the old equation, the new eGFR <60 ml/min/1.73 m2 had a better discrimination ability for the 30-day mortality (Harell's C: 0.563 (95 % CI 0.518-0.608) vs, 0.583 (95 % CI 0.546-0.636); delta Harell's C, 0.031 ± 0.022, p < 0.001). Similar findings were consistently observed in the cystatin creatinine-based equations. CONCLUSIONS: The application of the new race-independent estimators of GFR results in the reassessment of renal function in a significant proportion of TAVI patients and may influence the risk stratification of this population.


Assuntos
Estenose da Valva Aórtica , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Medição de Risco , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/terapia , Taxa de Filtração Glomerular , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Creatinina
14.
Clin Res Cardiol ; 111(12): 1367-1376, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35852581

RESUMO

BACKGROUND: Liver dysfunction is associated with an increased risk of mortality after cardiac interventions. The Fibrosis-4 (FIB-4 index), a marker of hepatic fibrosis, has been associated with a worse prognosis in heart failure. The prognostic relevance of the index in patients undergoing transcatheter aortic valve replacement (TAVR) is unknown. The aim of this study was to evaluate the clinical implications associated with the FIB-4 index in patients undergoing TAVR. METHODS: Between May 2012 and June 2019, 941 patients undergoing TAVR were stratified into a low or high FIB-4 index group, based on a cutoff value that was determined according to a receiver operating characteristic curve predicting 1-year all-cause mortality. RESULTS: Patients with a high FIB-4 index (n = 480), based on the cutoff value of 1.82, showed higher rates of pulmonary hypertension (43.8% vs. 31.8%, p < 0.01), right-ventricular systolic dysfunction (29.5% vs. 19.2%, p < 0.01) and larger inferior vena cava diameter (1.6 ± 0.6 cm vs. 1.3 ± 0.6 cm, p < 0.01) than patients with a low FIB-4 index (n = 461). Furthermore, a high FIB-4 index was associated with a significantly higher cumulative 1-year all-cause mortality (17.5% vs. 10.2%, p < 0.01) and non-cardiovascular mortality (12.1% vs. 2.5%, p < 0.01), compared to a low FIB-4 index. Multivariable analysis revealed that a high FIB-4 index was independently associated with all-cause mortality (HR: 1.75 [95% CI: 1.18-2.59], p < 0.01). CONCLUSIONS: A high FIB-4 index is associated with right-sided heart overload and an increased risk of mortality in patients undergoing TAVR. The FIB-4 index may be useful as an additional predictor of outcomes in these patients.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Prognóstico , Índice de Gravidade de Doença , Fibrose , Valva Aórtica/cirurgia , Fatores de Risco
15.
Heart Vessels ; 37(10): 1801-1807, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35505257

RESUMO

The left axillary artery is an attractive alternative access route for transcatheter aortic valve replacement (TAVR) and may provide better outcomes compared to other alternatives. Nevertheless, there remain concerns about vascular complications, lack of compressibility, and thorax-related complications. Between March 2019 and March 2021, 13 patients underwent transaxillary TAVR for severe aortic stenosis at the University Hospital Bonn. The puncture was performed with a puncture at the distal segment of the axillary artery through the axilla, with additional femoral access for applying a safety wire inside the axillary artery. Device success was defined according to the VARC 2 criteria. The study participants were advanced in age (77 ± 9 years old), and 54% were female, with an intermediate risk for surgery (STS risk score 4.7 ± 2.0%). The average diameter of the distal segment of the axillary artery was 5.8 ± 1.0 mm (i.e., the puncture site) and 7.6 ± 0.9 mm for the proximal axillary artery. Device success was achieved in all patients. 30-day major adverse cardiac and cerebrovascular events were 0%. With complete percutaneous management, stent-graft implantation was performed at the puncture site in 38.5% of patients. Minor bleeding was successfully managed with manual compression. Moreover, no thorax-related complications, hematomas, or nerve injuries were observed. Percutaneous trans-axilla TAVR was found to be feasible and safe. This modified approach may mitigate the risk of bleeding and serious complications in the thorax and be less invasive than surgical alternatives.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Axila/cirurgia , Feminino , Artéria Femoral/cirurgia , Hemorragia/etiologia , Humanos , Masculino , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
16.
BMC Cardiovasc Disord ; 22(1): 201, 2022 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-35484492

RESUMO

BACKGROUND: The clinical efficacy of the Impella for high-risk percutaneous coronary intervention (PCI) and cardiogenic shock remains under debate. We thus sought to investigate the protective effects on the heart with the Impella's early use pre-PCI using cardiac magnetic resonance imaging (CMRI). METHODS: We retrospectively evaluated the difference in the subacute phase CMR imaging results (19 ± 9 days after admission) between patients undergoing an Impella (n = 7) or not (non-Impella group: n = 18 [12 intra-aortic balloon pumps (1 plus veno-arterial extracorporeal membrane oxygenation) and 6 no mechanical circulation systems]) in broad anterior ST-elevation myocardial infarction (STEMI) cases. A mechanical circulation system was implanted pre-PCI. RESULTS: No differences were found in the door-to-balloon time, peak creatine kinase, and hospital admission days between the Impella and non-Impella groups; however, the CMRI-derived left ventricular ejection fraction was significantly greater (45 ± 13% vs. 34 ± 7.6%, P = 0.034) and end-diastolic and systolic volumes smaller in the Impella group (149 ± 29 vs. 187 ± 41 mL, P = 0.006: 80 ± 29 vs. 121 ± 40 mL, P = 0.012). Although the global longitudinal peak strain did not differ, the global radial (GRS) and circumferential peak strain (GCS) were significantly higher in the IMPELLA than non-IMPELLA group. Greater systolic and diastolic strain rates (SRs) in the Impella than non-Impella group were observed in non-infarcted rather than infarcted areas. CONCLUSIONS: Early implantation of an Impella before PCIs for STEMIs sub-acutely prevented cardiac dysfunction through preserving the GRS, GCS, and systolic and diastolic SRs in the remote myocardium. This study provided mechanistic insight into understanding the usefulness of the Impella to prevent future heart failure.


Assuntos
Infarto Miocárdico de Parede Anterior , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Infarto Miocárdico de Parede Anterior/complicações , Infarto Miocárdico de Parede Anterior/diagnóstico por imagem , Infarto Miocárdico de Parede Anterior/terapia , Humanos , Imageamento por Ressonância Magnética , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Choque Cardiogênico/diagnóstico por imagem , Choque Cardiogênico/etiologia , Volume Sistólico , Função Ventricular Esquerda
17.
J Atheroscler Thromb ; 29(1): 69-81, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33208566

RESUMO

AIM: According to recent clinical trials, a combination of direct oral anticoagulants with antiplatelet drugs is often recommended for atrial fibrillation patients who receive drug-eluting stents (DESs). Although the optimal combination comprises direct factor Xa inhibitors and a P2Y12 receptor antagonist (or aspirin), their influence on vascular responses to DESs remains unclear. METHODS: Pigs were given either aspirin and clopidogrel (dual antiplatelet therapy [DAPT] group), aspirin and rivaroxaban (AR group), or clopidogrel and rivaroxaban (CR group), followed by everolimus-eluting stent (Promus Element) implantation into the coronary artery. Stented coronary arteries were evaluated via intravascular optical coherence tomography (OCT) and histological analysis at 1 and 3 months. RESULTS: OCT revealed lower neointimal thickness in the DAPT group and comparable thickness among all groups at 1 and 3 months, respectively. Histological analyses revealed comparable neointimal area among all groups and the smallest neointimal area in the CR group at 1 and 3 months, respectively. In the DAPT and AR groups, the neointima continued to grow from 1 to 3 months. A shortened time course for neointima growth was observed in the CR group, with rapid growth within a month (maintained for 3 months). A higher incidence of in-stent thrombi was observed in the AR group at 1 month; no thrombi were found in either group at 3 months. More smooth muscle cells with contractile features were found in the CR group at both 1 and 3 months. CONCLUSIONS: Our results proved the noninferiority of the combination of rivaroxaban with an antiplatelet drug, particularly the dual therapy using rivaroxaban and clopidogrel, compared to DAPT after DES implantation.


Assuntos
Clopidogrel/administração & dosagem , Stents Farmacológicos , Inibidores do Fator Xa/administração & dosagem , Oclusão de Enxerto Vascular/prevenção & controle , Inibidores da Agregação Plaquetária/administração & dosagem , Rivaroxabana/administração & dosagem , Animais , Aspirina/administração & dosagem , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/patologia , Estenose Coronária/prevenção & controle , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Quimioterapia Combinada , Everolimo/administração & dosagem , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/patologia , Imunossupressores/administração & dosagem , Masculino , Suínos , Tomografia de Coerência Óptica
18.
J Atheroscler Thromb ; 29(4): 464-473, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33658453

RESUMO

AIM: Coronary plaque rupture is the main cause of acute coronary syndrome (ACS), but the role of blood flow features around plaque rupture for ACS is still unknown. The present study aimed to assess the relationship between the geometric configuration of ruptured plaque and ACS occurrence using computational fluid dynamics (CFD) by moving particle method in patients with coronary artery disease. METHODS: In this study, 45 patients with coronary artery disease who underwent three-dimensional intravascular ultrasound (IVUS) and had a coronary ruptured plaque (24 plaques with provoked ACS, 21 without) were included. To compare the difference in blood flow profile around ruptured plaque between the patients with and without ACS, the IVUS images were analyzed via the novel CFD analysis. RESULTS: There were no significant differences in localized flow profile around ruptured plaque between the two groups when the initial particle velocity was 10.0 cm/s corresponded to a higher coronary flow velocity at ventricular diastole. However, when it was 1.0 cm/s corresponded to lower coronary flow velocity at ventricular systole, particles with lower velocity (0 ≤ V ≤ 5 cm/s) were more prevalent around ACS-PR ( p=0.035), whereas particles with higher velocity (10 ≤ V ≤ 20 cm/s) were more often detected in silent plaque ruptures (p=0.018). CONCLUSIONS: Three-dimensional IVUS revealed that coronary plaque rupture was a complex one with a wide variety of its stereoscopic configuration, leading to various patterns of the local coronary flow profile. A novel CFD analysis suggested that the local flow was more stagnant around ACS-provoked ruptures than in silent ones.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Placa Aterosclerótica , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/etiologia , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Placa Aterosclerótica/complicações , Placa Aterosclerótica/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos
19.
Int J Cardiol ; 348: 26-32, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34923001

RESUMO

BACKGROUND: Pulmonary hypertension (pH) has a prognostic impact on patients undergoing transcatheter aortic valve replacement (TAVR). Pulmonary artery (PA) dilatation assessed by multidetector computed tomography (MDCT) has the potential to predict PH. The aim of the study was to evaluate the clinical parameters associated with PA dilatation and to investigate its prognostic relevance in patients undergoing TAVR. METHODS: In 770 patients undergoing TAVR between February 2016 and July 2019, PA diameter was measured by MDCT before TAVR. Additionally, PA diameter divided by ascending aorta diameter or body surface area (BSA) was calculated. RESULTS: Of all the CT-derived parameters compared with a receiver operating characteristic curve, the value for PA/BSA with a median of 1.68 (IQR 1.47, 1.91) cm/m2 showed the greatest area-under-the-curve (0.75) for predicting PH at baseline. Based on this median, patients were assigned to a small PA/BSA (n = 386) or a large PA/BSA (n = 384) group. Hereby, a large PA/BSA was independently associated with PH at baseline (OR:8.39 [5.36-13.14], p < 0.001) and after TAVR (OR:1.73 [1.18-2.53], p = 0.005). A large PA/BSA was associated with a significantly higher cumulative two-year all-cause mortality compared to small PA/BSA (30.0% vs. 13.7%, p < 0.001), which was supported in the multivariable model (HR:1.87; 95%CI, 1.12-3.04; p = 0.017). CONCLUSION: Patients with a large PA/BSA on MDCT are more likely to have PH at baseline and after TAVR. Large PA/BSA is associated with an increased risk of mortality and could provide additional information for risk stratification in patients undergoing TAVR.


Assuntos
Estenose da Valva Aórtica , Hipertensão Pulmonar , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Superfície Corporal , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
20.
Heart Vessels ; 36(6): 756-765, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33403471

RESUMO

The significance of microvessels within atherosclerotic plaques is not yet fully clarified. Associated with plaque vulnerability. The aim of this study is to examine tissue characteristics of plaque with microvessels detected by optical coherence tomography (OCT) by use of a commercially available color-coded intravascular ultrasound (IVUS) and coronary angioscopy (CAS). The subjects examined comprised of 44 patients with stable angina pectoris who underwent percutaneous coronary intervention. Microvessels were defined as a tiny tubule with a diameter of 50-300 µm detected over three or more frames in OCT. We compared the total volume of microvessels with tissue component such as fibrotic, lipidic, necrotic, and calcified volume and the number of yellow plaque. In IVUS analysis, % necrotic volume and % lipidic volume were significantly correlated and % fibrotic volume was inversely significantly correlated with the total volume of microvessel (r = 0.485, p = 0.0009; r = 0.401, p = 0.007; r = - 0.432, p = 0.003, respectively). The number of plaque with an angioscopic yellow grade of two or more was significantly correlated with the total volume of microvessel (r = 0.461, p = 0.002). The greater the luminal volume of microvessels, the more the percent content of necrotic/lipidic tissue volume within plaque and the more the number of yellow plaques. These data suggested that microvessels within coronary plaque might be related to plaque vulnerability.


Assuntos
Aterosclerose/diagnóstico , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Imagem Multimodal , Tomografia de Coerência Óptica/métodos , Túnica Íntima/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Idoso , Angioscopia/métodos , Cateterismo Cardíaco , Feminino , Seguimentos , Humanos , Masculino , Microvasos/diagnóstico por imagem , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA