Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cornea ; 41(3): 353-358, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34839329

RESUMO

PURPOSE: The aim of this study was to describe a new type of medical device that allows for internet-enabled patient self-screening, without the aid of an ophthalmic professional, through biomicroscopy self-imaging and self-measurement of the best-corrected visual acuity (BCVA). METHODS: In this prospective nonrandomized comparative study, 56 patients were instructed to screen their own eyes using a custom-built e-Device containing miniaturized slitlamp optics and a visual acuity Snellen chart virtually projected at 20 ft. BCVA measurements were recorded, and biomicroscopic videos were scored for image quality of the anterior segment status on a scale from 1 to 5 (1 = poor and 5 = excellent) by a blinded observer. RESULTS: After a short instruction, all patients were able to self-image their eyes and perform a self-BCVA measurement using the e-Device. Patient self-image quality with the e-Device scored on average 3.3 (±0.8) for videos (n = 76) and 3.6 (±0.6) for photographs (n = 49). Self-BCVA measurement was within 1 Snellen line from routine BCVA levels in 66 of 72 eyes (92%). When compared with conventional biomicroscopy, patient self-biomicroscopy allowed for recognition of the relevant pathology (or absence thereof) in 26 of 35 eyes (74%); 9 cases showed insufficient image quality attributed to device operating error (n = 6) and mild corneal edema and/or scarring (n = 3). Patient satisfaction with the device was 4.4 (±0.9). CONCLUSIONS: An e-Device for combined BCVA self-measurement and biomicroscopy self-imaging may have potential as an aid in remote ophthalmic examination in the absence of an ophthalmic professional and may be considered for patients who are unable to visit an ophthalmic clinic for routine follow-up.


Assuntos
COVID-19/prevenção & controle , Quarentena , SARS-CoV-2 , Autoexame/métodos , Telemedicina/métodos , Seleção Visual/instrumentação , Acuidade Visual/fisiologia , Adulto , Idoso , COVID-19/epidemiologia , Controle de Doenças Transmissíveis/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Microscopia com Lâmpada de Fenda
2.
IEEE Trans Biomed Eng ; 67(3): 931-937, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31247540

RESUMO

Intraocular pressure (IOP) is the leading modifiable risk factor for preventing vision loss in glaucoma patients. Direct and frequent IOP measurements are highly desirable to assess adequacy of treatment and prevent further vision loss. In this study, we report on successful in vivo measurements of intraocular pressure in rabbits using an optical IOP measurement system. The sensor was implanted during cataract surgery in two New Zealand white (NZW) rabbits and tested in vivo for ten weeks. Prior to implantation, the sensors were characterized in vitro in the physiologically relevant pressure range of 0-60 mmHg. A portable wireless handheld reader consisting of an internal beam splitter, a monochromatic light source, and a digital single-lens reflex (DSLR) camera was also designed and implemented to capture interference patterns from the sensor. The sensitivity and accuracy of the sensor was 30 nm/mmHg and ±0.2 mmHg, respectively. Ten weeks post-implantation, the two NZW rabbits continued to respond well to the implant with no observable inflammation, signs of infection, or biofouling. All IOP measurements were obtained using the portable DSLR handheld reader. Successful in vivo studies demonstrate biocompatibility of the IOP sensor and prove feasibility of the IOP measurement system. The system has the potential to be used in both clinical and patient point-of-care (home) settings to frequently and accurately measure pressure.


Assuntos
Pressão Intraocular/fisiologia , Tonometria Ocular/instrumentação , Tecnologia sem Fio/instrumentação , Animais , Pesquisa Biomédica , Desenho de Equipamento , Glaucoma , Interferometria , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...