Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
1.
Arch Orthop Trauma Surg ; 143(7): 4299-4307, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36645460

RESUMO

INTRODUCTION: Risk factors (RF) associated with aseptic loosening (AL) in total knee arthroplasty (TKA) are poorly understood. Therefore, the aim of this study was to investigate the anatomical shape variations in relation to the inner-diameter of the femur and the tibia as prognostic RF for AL of full hinge prosthesis (FHP) in primary and revision TKA. MATERIALS AND METHODS: We retrospectively examined all patients, who underwent revision surgery (2003-2018) due to AL of the FHP in primary (n = 38) and revision TKA (n = 46). Diagnosis-appropriate controls without AL at minimum follow-up of 24 months were randomly collected for each group. Besides other risk factors, we also measured the inner diameter of the femur according to the Citak classification and of the tibia on anteroposterior radiographies. RESULTS: RF for AL are younger age in primary and revision as well as > 1 previous surgeries in revision TKA. The femoral index was shown to be a RF for AL in revision TKA (p = 0.001), but not in primary TKA. The novel tibial index was associated with AL in primary with AUC 0.776 (95% CI 0.67, 0.88), 65.8% sensitivity, 86.6% specificity and in revision TKA with AUC 0.817 (95% CI 0.73, 0.91), 82.6% sensitivity and 71.7% specificity. CONCLUSION: This is the first study to calculate the tibial measurements and the tibial index according to Citak et al. and to identify them as prognostic RF for AL of the full hinge knee prosthesis in TKA and confirm the femoral index as a RF for AL also in revision full hinge knee prosthesis. Therefore, the preoperative radiological evaluation should include the analysis of the anatomical shape variants in order to select the appropriate prosthesis design with a possibly enhanced prognosis.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Estudos Retrospectivos , Falha de Prótese , Fatores de Risco , Desenho de Prótese , Reoperação , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia
2.
Arch Orthop Trauma Surg ; 143(6): 2895-2900, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35597883

RESUMO

INTRODUCTION: Even though an increased interest in the use of the EFAS Score (European Foot and Ankle Society) has been observed, no data comparing it with radiological findings has been presented in the literature. Accordingly, the aim of this study is to investigate how the post-operative integration of the AMIC® (autologous matrix-induced chondrogenesis)-membrane for osteochondral lesion of the talus using the MOCART (Magnetic Resonance Observation of Cartilage Repair Tissue) - Score is related to the clinical satisfaction of the patients. MATERIAL AND METHODS: A group of 24 patients aged between 17 and 63 (with a mean age of 35.7) were included at least 1 year post-operatively. They had all undergone an AMIC®-procedure of the talus. MRI findings using the MOCART Score were correlated to the EFAS Score at the same time point. RESULTS: Our main results showed no correlation between the MOCART-Score and the EFAS-Score (R = - 0.08). There was also no correlation between the MOCART-Score, the FFI-Score (Foot and Function Index) (R = 0.2) and the MOXFQ-Score (Manchester-Oxford Foot Questionnaire) (R = 0.12). There was no correlation between components of the MOCART-Score with the EFAS-Score (R between - 0.32 and 0.23). CONCLUSION: Our results question whether the MRI (a standard part of AMIC®-procedure-of-the-ankle post-operative follow-up) is still the most appropriate tool for post-operative control. They also offer a starting point for future discussion regarding the need for post-operative MRI and the use of other radiological diagnostics in relation to clinical satisfaction.


Assuntos
Cartilagem Articular , Fraturas Intra-Articulares , Tálus , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Tálus/diagnóstico por imagem , Tálus/cirurgia , Resultado do Tratamento , Transplante Autólogo/métodos , Imageamento por Ressonância Magnética/métodos , Extremidade Inferior , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/cirurgia
3.
Technol Health Care ; 30(6): 1417-1422, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35661032

RESUMO

BACKGROUND: Posterior instrumentation using pedicle screws and rods is the most commonly used technique for the treatment of thoracolumbar fractures of the spine. The procedure aims to restore the neurologic and biomechanical functions of the spine and allows for early mobilization and rapid reintegration into society. It is unclear whether the magnitude of correction has an effect on postoperative outcomes. OBJECTIVE: We aimed to determine whether the magnitude of sagittal angular correction during posterior instrumentation of the spine had an effect on postoperative quality of life, pain and function outcomes as measured using the EQ5D-3L and the Core Outcome Measures Index (COMI) instruments. We also aimed to quantify the correlation between EQ5D-3L and COMI scores. METHODS: We analyzed the pre- and postoperative radiographs of 52 patients who underwent percutaneous pedicle screw placement for thoracolumbar fractures, as well as their self-reported EQ5D-3L and COMI quality of life, pain and functional outcome scores. Regression models were constructed to estimate the effect that the magnitude of Cobb angle correction had on postoperative outcomes. We also estimated the correlation between EQ5D-3L and COMI scores. RESULTS: The median EQ5D-3L TTO score was 0.9 (range, -0.1 to 1). The median COMI score was 3.1 (range, 0 to 10). There was no significant effect of the magnitude of correction on EQ5d-3L TTO scores (p= 0.3379; R= 0.36) or on COMI scores (p= 0.3379; R= 0.15). Age and bone mineral density were not found to be significant predictors of outcome (p= 0.05). There was a strong correlation between the EQ5D-3L TTO and COMI scores (r=-0.62). CONCLUSION: The magnitude of Cobb angle correction during pedicle screw instrumentation of thoracolumbar fractures did not influence quality of life, pain or function outcomes. There was good correlation between EQ5D-3L TTO scores and COMI scores.


Assuntos
Parafusos Pediculares , Fraturas da Coluna Vertebral , Humanos , Fraturas da Coluna Vertebral/cirurgia , Vértebras Torácicas/cirurgia , Qualidade de Vida , Vértebras Lombares/cirurgia , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Dor , Estudos Retrospectivos
4.
In Vivo ; 36(1): 384-390, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34972739

RESUMO

BACKGROUND/AIM: Open surgical reduction/fixation of thoracolumbar fractures results in significant soft-tissue trauma and related complications. Minimally-invasive technical developments could deliver similar radiological outcomes, while avoiding the related complications. We evaluated radiological and perioperative outcomes in thoracolumbar fractures by using a novel minimally-invasive device. PATIENTS AND METHODS: Twenty-six patients with 29 thoracolumbar fractures using the NForce device were analyzed. Postoperative reduction and alignment were assessed by radiographic measurement of the local kyphosis angle (LKA) up until a follow-up period of 9 months. RESULTS: Postoperative imaging revealed an average reduction of traumatic kyphosis of 8.25° (±7.72°) with an average postoperative LKA of 3.24° (±8.97°). The highest degree of reduction was 27.39°. The mean LKA had increased to 5.08° (±5.17°) at 3 months postoperative, 5.43° (±4.32°) at 6 months and 6.21° (±3.82°) at 9 months. CONCLUSION: The minimally invasive NForce system is effective in performing anatomic percutaneous reduction/fixation.


Assuntos
Fraturas da Coluna Vertebral , Vértebras Torácicas , Fixação Interna de Fraturas , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Estudos Retrospectivos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/lesões , Vértebras Torácicas/cirurgia , Resultado do Tratamento
5.
Arch Orthop Trauma Surg ; 142(2): 315-322, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33638676

RESUMO

INTRODUCTION: In our previous studies, we were able to identify anatomical differences as a predictor for aseptic loosening following primary and revision surgery with the use of rotating hinge prosthesis. This study was performed to answer following question: can a novel radiological classification system of the distal femur be identified? MATERIALS AND METHODS: A total of 200 patients who received standardized anteroposterior (AP) and lateral views of the knee joint were included in this study. On AP radiographs, we measured the distance between inner diameter of the femur at 20 cm proximally from the knee and at a point 2 cm proximally from the adductor tubercle. The ratio of the inner diameter of the femoral canal at 20 cm proximal of knee joint to the inner diameter of medullary canal at 2 cm proximal of adductor tubercle was used as a novel index ratio. Two observers blindly and independently reviewed the anteroposterior radiographs twice. RESULTS: Three groups of anatomical classification can be constructed for each sex according to the 25th and 75th percentiles. A higher distribution of Type C was found in female patients. The median intra-observer reliability for rater 1 was 0.995 (IQR 0.994-0.997). We had also a high inter-observer reliability with ICC of 0.997 (95% CI 0.996-0.998). CONCLUSIONS: The novel classification presents three different types of the knee joint for male and female patients. Type C has a wider inner diaphyseal diameter compared to Type A with a narrow inner diaphyseal diameter.


Assuntos
Fêmur , Prótese do Joelho , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Masculino , Radiografia , Reprodutibilidade dos Testes
6.
Eur J Trauma Emerg Surg ; 48(5): 3659-3667, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33388784

RESUMO

AIM: Intramedullar nailing of tibial mid-shaft fractures is a common surgical treatment. Fracture reduction, however, remains challenging and maltorsion is a common discrepancy which aggravates functional impairment of gait and stability. The use of radiographic tools such as the cortical step sign (CSS) and the diameter difference sign (DDS) could improve fracture reduction. Therefore, the validity of the CSS and DDS was analyzed to facilitate detection of maltorsion in tibial mid-shaft fractures. METHODS: Tibial mid-shaft fractures were induced in human cadaveric tibiae according to the AO classification type A3. Torsional discrepancies from 0° to 30° in-/external direction were enforced after intramedullary nailing. Fluoroscopic-guided fracture reduction was assessed in two planes via analysis of the medical cortical thickness (MCT), lateral cortical thickness (LCT), tibial diameter (TD), anterior cortical thickness (ACT), posterior cortical thickness (PCT) and the transverse diameter (TD) of the proximal and distal fracture fragment. RESULTS: The TD, LCT and ACT have shown a highly significant correlation to predict tibial maltorsion. While a model combining ACT, LCT, PCT and TD lateral was most suitable model to identify tibial maltorsion, a torsional discrepancy of 15°was most reliably detected with use of the TD and ACT. CONCLUSION: The present study has shown, that maltorsion can be reliably assessed by the CSS and DDS during fluoroscopy. Thus, torsional discrepancies in tibial mid-shaft fractures can be most reliably assessed in the lateral plane by analysis of the LCT and TD.


Assuntos
Fixação Intramedular de Fraturas , Fraturas da Tíbia , Pinos Ortopédicos , Diáfises , Fixação de Fratura , Humanos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Resultado do Tratamento
7.
Acta Inform Med ; 29(2): 130-133, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34584337

RESUMO

BACKGROUND: The use of computer assisted surgery, navigation (NAV) in shoulder arthroplasty is still under discussion, regarding the clinical outcome and prosthesis longevity, especially when combining these factors with cost, time and surgeon's experience. Beside the NAV, there has been in use patient-specific instrumentation (PSI) as an additional tool for more precise glenoid implant position. Surgical NAV and PSI for glenoid implant positioning in anatomic and reverse total shoulder arthroplasty are in last years under observation and discussion. OBJECTIVE: To critically review and evaluate the current literature regarding the use of computer navigation and PSI in shoulder arthroplasty. METHODS: Critical review of the existing literature. RESULTS: Cost-effectiveness, prosthesis longevity and revision arthroplasty rate have not yet been proven clinically. Moreover, heterogeneity is high in studies that include different positioning systems (NAV, PSI and standard instrumentation). Heterogeneity is due to differences in surgical technique, implants, surgeon's expertise, radiographic image analysis technique. CONCLUSION: The use of navigation systems and PSI should be clinically proven in the shoulder arthroplasty. Independent experts' opinion and independent high level studies lack at the moment. There will be still a lot of talk regarding this topic in future.

8.
BMC Musculoskelet Disord ; 22(1): 590, 2021 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-34174846

RESUMO

AIM: The treatment of tibial fractures with an intramedullary nail is an established procedure. However, torsional control remains challenging using intraoperatively diagnostic tools. Radiographic tools such as the Cortical Step Sign (CSS) and the Diameter Difference Sign (DDS) may serve as tools for diagnosing a relevant malrotation. The aim of this study was to investigate the effect of torsional malalignment on CSS and DDS parameters and to construct a prognostic model to detect malalignment. METHODS: A proximal tibial shaft fracture was set in human tibiae. Torsion was set stepwise from 0° to 30° in external and internal torsion. Images were obtained with a C-arm and transferred to a PC for measuring the medical cortical thickness (MCT), lateral cortical thickness (LCT), tibial diameter (TD) in AP and the anterior cortical thickness (ACT) as well as the posterior cortical thickness (PCT) and the transverse diameter (TD) of the proximal and the distal main fragment. RESULTS: There were significant differences between the various degrees of torsion for each of the absolute values of the examined variables. The parameters with the highest correlation were TD, LCT and ACT. A model combining ACT, LCT, PCT and TD lateral was most suitable model in identifying torsional malalignment. The best prediction of clinically relevant torsional malalignment, namely 15°, was obtained with the TD and the ACT. CONCLUSION: This study shows that the CSS and DDS are useful tools for the intraoperative detection of torsional malalignment in proximal tibial shaft fractures and should be used to prevent maltorsion.


Assuntos
Mau Alinhamento Ósseo , Fixação Intramedular de Fraturas , Fraturas da Tíbia , Pinos Ortopédicos , Cadáver , Diáfises , Humanos
9.
In Vivo ; 35(3): 1625-1632, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33910845

RESUMO

BACKGROUND/AIM: Septic arthritis (SA) requires rapid diagnosis and therapy to avoid joint damage. This study evaluated the diagnostic accuracy of leukocyte esterase (LE) and glucose (GLC) strip tests for diagnosing SA. PATIENTS AND METHODS: Synovial fluids from 455 patients with atraumatic joint effusions were assessed prospectively over a 5-year period with LE and glucose strip tests. Results were compared to modified Newman criteria for diagnosing joint infections. Synovial fluid cultures, crystal, blood and synovial cell analyses were also performed. RESULTS: Forty-one patients had SA and 252 non-SA. A positive LE reading combined with negative glucose reading could detect SA with 100% specificity, 85% sensitivity, 100% positive predictive value (PPV) and 98% negative predictive value (NPV). Positive synovial LE reading alone detected SA with 82% specificity, 95% sensitivity, 47% PPV, and 99% NPV. CONCLUSION: Combined LE and glucose strip tests represent a low-cost tool for rapidly diagnosing or ruling out SA.


Assuntos
Artrite Infecciosa , Artrite Infecciosa/diagnóstico , Biomarcadores , Hidrolases de Éster Carboxílico , Glucose , Humanos , Indicadores e Reagentes , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Líquido Sinovial
12.
Injury ; 52(10): 2707-2711, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32033807

RESUMO

BACKGROUND: Percutaneous sacroiliac (SI) screw fixation is the standard operative treatment of traumatic disruptions to the posterior pelvic ring. The technique offers good outcomes and early postoperative mobilization, which is vital in elderly patients with fragility fractures of the pelvis. While a double-screw technique has been shown to provide optimal biomechanical stability compared to a single-screw construct, anatomic variations and patient-specific characteristics may prevent the safe insertion of two SI screws. We aimed to determine whether cement augmentation of a single SI screw would provide biomechanical stability comparable to that of the double-screw technique. METHODS: Three sacroiliac screw osteosynthesis configurations were tested on 10 human cadaveric pelvis specimens: a single cannulated screw; two cannulated screws; and a single, cement-augmented cannulated screw. Displacement and stiffness of the anterior and posterior pelvic ring after fixation with each technique were measured under axial load. Results where compared using linear regression and paired t-tests. RESULTS: A single uncemented screw offered significantly worse stability in the anterior pelvis compared to a double-screw technique (P < 0.05) and to a single cement-augmented screw technique (P < 0.05). There was no significant difference in anterior pelvic ring stability between the single cement-augmented screw technique and the double-screw technique (P > 0.05). There was no significant difference in the stability of the posterior pelvic ring between the three techniques (P > 0.05). CONCLUSIONS: A single cement-augmented cannulated sacroiliac screw provides biomechanical stability similar to that of a non-augmented double-screw technique in the treatment of posterior pelvic ring fractures.


Assuntos
Parafusos Ósseos , Ossos Pélvicos , Idoso , Fenômenos Biomecânicos , Cimentos Ósseos , Fixação Interna de Fraturas , Humanos , Ossos Pélvicos/cirurgia
13.
Orthop Traumatol Surg Res ; 107(4): 102668, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32798125

RESUMO

BACKGROUND: Periprosthetic joint infection is a serious disease with severe consequences for the patient's life. It is not known whether one-stage or two-stage replacement arthroplasty is superior. So far, there have been no studies on short-term complications between both surgical procedures. Therefore, we performed a retrospective study aiming to determine: 1) Does two-stage septic exchange arthroplasty have a higher short-term complication rate than one-stage? 2) Is there a difference in length of hospital stay and the in-hospital mortality rate between two- and one-stage septic exchange arthroplasty? HYPOTHESIS: Two-stage septic exchange arthroplasty has a higher short-term complication rate than one-stage. PATIENTS AND METHODS: Retrospectively 429 patients who underwent a one- or two stage revision arthroplasty (288 hips and 141 knees) due to chronic PJI between January 2015 and December 2016 were recruited (one-stage: n=385, two-stage: n=44). Differences in postoperative complications, surgical therapy, ASA, Charlson Comorbidity Index (CCI), length of hospital, need for plastic surgery, pathogen, in-hospital morbidity and in-hospital mortality were compared using multiple logistic and Poisson regression. Regarding comorbidities, age, gender and BMI the groups were comparable. RESULTS: It was 3.5 times more likely to suffer from a medical complication if a two stage septic exchange was performed (OR 3.465, (95% CI: 2.573-4.358) [p<0.01]). In medical complications the two-stage group showed significantly more events (two-stage: 9 of 44=20.5%; one-stage: 30 of 385=7.8% [p=0.013]). The one-stage group showed more (not significant) nerve palsies after hip septic exchange. There was no difference in mortality between the groups (two-stage: 1/44=2.3%; one-stage: 3/385=0.8% [p=0.882]), the overall mortality was 0.93%. The duration of hospital stay was 23.9±19 days for the one-stage and 42.2±17.7 days for the two-stage group (p<0.001). CONCLUSION: We found that it is more likely to develop a medical complication after two-stage septic revision arthroplasty. There was no difference in overall surgical complications between the two surgical approaches. We did not find a significant difference in short term mortality between the two techniques, although the mortality rate was slightly higher in the two-stage group. LEVEL OF EVIDENCE: III, retrospective case control study.


Assuntos
Artroplastia de Quadril , Artroplastia de Substituição , Infecções Relacionadas à Prótese , Artroplastia de Quadril/efeitos adversos , Estudos de Casos e Controles , Humanos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Reoperação , Estudos Retrospectivos
14.
Technol Health Care ; 29(2): 343-350, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32716336

RESUMO

BACKGROUND: Vertebroplasty and kyphoplasty are now well-established methods for treating compression fractures of vertebral bodies (AO type A) as well as vertebral body metastases [1, 2, 3]. However, polymethylmethacrylate (PMMA) augmented vertebrae show fractures of subsequent vertebral bodies due to the increased stability of the augmented vertebral body [4]. Resorbable cements are currently only used experimentally. Many commercially available resorbable calcium phosphate cements do not exhibit sufficient biomechanical stability to treat vertebral body fractures [5]. Resomer C212© (Evonik Industries AG, Essen, Germany) is a slow resorbable poly-ε-caprolactone that has low melting temperatures and good biomechanical properties. OBJECTIVE: This is a feasibility study on how the poly-ε-caprolactone Resomer C212© can be used for kypho- or vertebroplasty, what temperatures are used in the argumentation and how differences in load capacity are measurable compared to conventional PMMA cement. METHODS: 23 Sawbones© blocks (7.5 Open Cell Foam, SKU: 1522-09, laminated on both sides, 4 × 4 × 2.9 cm, Sawbones, Vashon Island, USA) were divided into three groups: 7 without augmentation, 8 augmented with PMMA cement Traumacem V+© (DePuy Synthes, West Chester, USA) and 8 augmented with Resomer C212©. Temperature measurements were made in a 37∘C water bath centrally in the block and on the top and bottom plates. This was followed by a maximum load of up to 2000 N using a universal testing machine (Instron E 10000, Instron Industrial Products, Grove City, USA). RESULTS: In the Resomer C212© test group, the maximum average increase in temperature was 4.15 ± 4.72∘C central, 0.3 ± 0.31∘C at the top and 0.78 ± 1.27∘C at the base. In the cement test group, the average increase in temperature was 9.80 ± 10.65∘C centrally in the test block, 1.50 ± 0.73∘C at the top plate and 1.42 ± 0.66∘C and the base plate. In the axial compression test, the 7 non-kyphoplasted test blocks showed a first loading peak on average at 275.23 ± 80.98 N, a rigidity of 238.47 ± 71.01 N/mm2. In the Traumacem V+© group, the mean peak load was 313.72 ± 46.26 N and rigidity was 353.45 ± 77.23 N/mm2. The Resomer C212© group achieved a peak load of 311.74 ± 52.05 N and a stiffness of 311.30 ± 126.63 N/mm2. A compression to 50% could not be seen in any test block under the load of 2000 N. At 2000 N, Traumacem V+©'s average height reduction was 9.26 ± 2.16 mm and Resomer C212© was 10.93 ± 0.81 mm. CONCLUSIONS: It has been shown that the application of Resomer C212© in kyphoplasty or vertebroplasty is well feasible. Thermal analysis showed significantly lower temperatures and shorter temperature application in the Resomer C212© group. In the biomechanical load up to 2000 N no significant differences could be observed between the individual groups.


Assuntos
Fraturas por Compressão , Cifoplastia , Fraturas da Coluna Vertebral , Vertebroplastia , Fenômenos Biomecânicos , Cimentos Ósseos , Estudos de Viabilidade , Humanos , Fraturas da Coluna Vertebral/cirurgia
15.
Orthop Traumatol Surg Res ; 107(1): 102745, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33333281

RESUMO

BACKGROUND: Elderly patients suffering from hip fractures are usually not able to fulfil postoperative weight-bearing restrictions. Therefore, the operative fixation construct has to be as stable as possible. Aim of the present study was to determine (1) whether a therapeutic advantage could be achieved when using hip arthroplasty to treat acetabular fractures in geriatric patients; (2) whether an acetabular revision cup would be suitable for achieving fast postoperative mobilization and full weight-bearing; and (3) when a treatment with an uncemented hip revision cup for the primary fixation of osteoporotic acetabular fractures in geriatric patients is indicated. MATERIALS AND METHODS: The functional outcome of THA using a reconstruction cup for an acetabular fracture was evaluated in ten patients using standardized scoring instruments. In addition, an analysis of the preexisting literature referring to total hip replacement in geriatric acetabular fractures was conducted and an algorithm for standardizing the treatment approach for geriatric patients with acetabular fractures was developed. RESULTS: The mean EQ-5D-3L quality of life score 0.7. The mean VAS Score was 58.2. The average Barthel Index was 80.0 points [range: 0-100]. The mean HHS was 72.0 points, while the MHH Score yielded an average of 63.4 points. The average AP Score was 7.5. The literature analysis showed that total hip arthroplasty could be a feasible option for geriatric acetabular fractures. CONCLUSION: Primary hip arthroplasty using uncemented revision cup fixed with angular stable screws showed good results and is a feasible treatment option of acetabular fractures in geriatric patients. The approach is especially beneficial in patients with poor bone stock and allows postoperative full weight-bearing. The presented treatment algorithm could be a useful tool for identifying the most appropriate treatment option. LEVEL OF EVIDENCE: IIb.


Assuntos
Artroplastia de Quadril , Fraturas do Quadril , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Idoso , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Humanos , Falha de Prótese , Qualidade de Vida , Reoperação
16.
Int Orthop ; 45(1): 125-132, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33188603

RESUMO

PURPOSE: This study aimed to determine the risk factors of aseptic loosening (AL) in complex revision total knee arthroplasty (TKA) cases using rotating hinge knee prosthesis. METHODS: Patients who had undergone re-revision rotating hinge prosthesis surgery between January 2012 and December 2017 were included. Parameters related to AL were retrospectively reviewed. For this purpose, 31 aseptic loosening patients and 30 control patients were included in the study. Various risk factors were evaluated. Risk factors for AL after re-revision were determined using univariate and multiple logistic regression analyses. RESULTS: Thirty-one AL patients and 30 control patients were included. In the AL group, tibial tantalum cone and impaction grafting were performed significantly less frequently than the control group (p = 0.002 and p < 0.001). Logistic regression analysis revealed that smoking, right-sided TKA, and large femoral canal anteroposterior diameter were factors that increased the risk of AL after re-revision, while tibial tantalum cone decreased the risk of loosening. Smokers had an 11.847-fold higher risk for AL; right-sided TKA led to a 4.594-fold higher risk for AL. However, the presence of a tibial tantalum cone was associated with an 8.403-fold lower risk for AL. CONCLUSIONS: We conclude that smoking, right-sided prosthesis, and large femoral canal diameter increased the risk of AL, while tantalum cone and impaction grafting reduced this risk in patients who underwent re-revision surgery with rotating hinge prosthesis after TKA.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/efeitos adversos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
17.
J Bone Joint Surg Am ; 103(6): 517-523, 2021 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-33369984

RESUMO

BACKGROUND: Successful results have been reported in association with the use of a rotating-hinge prosthesis for primary total knee arthroplasty (TKA). The objective of the present study was to identify risk factors for aseptic loosening in patients who underwent primary TKA with rotating-hinge knee prostheses. METHODS: The records of 1,235 patients who underwent primary TKA with a rotating-hinge prosthesis at our center were evaluated. A total of 125 patients who underwent revision were further evaluated according to the inclusion and exclusion criteria, and 33 patients who underwent revision because of aseptic loosening were then compared with a group of 30 patients who did not require revision surgery. All data, including radiographic measurements, were obtained from records prior to the primary TKA. RESULTS: On the basis of our review of demographic, anthropometric, clinical, surgical, and radiographic findings, we found that higher body mass index (BMI) was associated with revision. The majority of patients with aseptic loosening had loosening of the femoral component. Furthermore, the inner femoral diameter at 20 cm proximal to the knee joint (on both anteroposterior and lateral images) was found to be predictive of revision among those with aseptic loosening. Receiver operating characteristic curve analysis showed that an inner diameter of the femur of >19 mm on anteroposterior images had a sensitivity of 91% and specificity of 87% for predicting the need for revision surgery in patients with aseptic loosening. CONCLUSIONS: This is one of few studies that has focused on determining risk factors for the failure of rotating-hinge prostheses following TKA surgery. Our findings indicate that a novel variable, the inner (diaphyseal) diameter of the femur at the point 20 cm proximal to the knee joint, is an extremely reliable predictor of revision surgery in patients with aseptic loosening. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia do Joelho , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho , Adulto , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Estudos de Casos e Controles , Feminino , Fêmur/diagnóstico por imagem , Humanos , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
18.
Eur J Med Res ; 25(1): 26, 2020 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-32682448

RESUMO

INTRODUCTION: Unstable fractures of the pelvis remain the predominant cause of severe hemorrhage, shock and early death in severely injured patients. The use of pelvic binders has become increasingly popular, particularly in the preclinical setting. There is currently insufficient evidence available about the stability of the pelvic binder versus supraacetabular fixation using 1 or 2 Schanz screws. We aimed to analyze the stability of the pelvic binder and supraacetabular fixateurs using either 1 or 2 Schanz screws in a cadaver model of an induced pelvic B-type fracture. MATERIALS AND METHODS: The study was undertaken in 7 human fresh-frozen cadaveric pelvises with induced AO-type B fractures. Three stabilization techniques were compared: T-POD (pelvic bandage), supraacetabular external fixator with 1 pin on each side and external fixator with 2 pins on each side. Stability and stiffness were analyzed in a biomechanical testing machine using a 5-step protocol with static and dynamic loading, dislocation data were retrieved by ultrasound sensors at the fracture sites. RESULTS: No significant differences in fracture fragment displacement were detected when using either the T-POD, a 1-pin external fixator or a 2-pin external fixator (P > 0.05). The average difference in displacement between the three methods was < 1 mm. CONCLUSIONS: Pelvic binders are suitable for reduction of pelvic B-type fractures. They provide stability comparable to that of supraacetabular fixators, independently of whether 1 or 2 Schanz screws per side are used. Pelvic binders provide sufficient biomechanical stability for transferring patients without the need to first replace them with surgically applied external fixators. However, soft tissue irritation has to be taken into consideration and prolonged wear should be avoided. LEVEL OF EVIDENCE: Level III.


Assuntos
Parafusos Ósseos , Fixadores Externos , Fixação de Fratura/instrumentação , Fixação de Fratura/métodos , Fraturas Ósseas/cirurgia , Ossos Pélvicos/lesões , Ossos Pélvicos/cirurgia , Acetábulo/lesões , Acetábulo/cirurgia , Adulto , Idoso , Fenômenos Biomecânicos , Feminino , Seguimentos , Fraturas Ósseas/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos
19.
Technol Health Care ; 28(2): 185-192, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32224535

RESUMO

BACKGROUND: Up to date there is no intramedullary, biodegradable osteosynthesis commercially available to treat non-comminuted midshaft fractures of small hollow bones applying not only a stable osteosynthesis but an additional axial compression to the fracture site. OBJECTIVE AND METHODS: Therefore we (1) designed different implant profiles and simulated the inner tension/volume using CAD. (2) Thereafter we manufactured a prototype with the best volume/tension-ratio using 70:30 poly-(L-lactide-co-D, L-lactide) (PLLA/PDLLA) and poly-ε-caprolactone (PCL) by injection moulding. Both materials are resorbable, licensed for medical use and show a slow degradation over at least one year. (3) The implants were tested in a universal testing machine (Zwick/RoellZ010) using a 3-point-bending-setup. (4) We compared the implants with different types of commercially available Ti6Al4V 6-hole 2, 3 mm-plates including interlocking systems (Leibinger Set, Stryker) (each group n= 6) using a 4-point-bending-test-setup with artificial metacarpal bones (Sawbones®). RESULTS: The 3-point-bending-test-results showed that mean failure-force of PCL-tubes was 57.94 ± 4.28 N whereas the PLLA/PDLLA-tubes had an approximately four-fold higher value of 227.24 ± 1.87 N (p< 0.001). Additionally, the 4-point-bending-test-results showed that the maximum load of PLLA/PDLLA tubes (61.97 ± 3.58 N) was significantly higher than the strongest 6-hole metacarpal plate (22.81 ± 0.76 N) (p< 0.001). CONCLUSION: The study showed that the new type of biodegradable, intramedullary tension-osteosynthesis made of PLLA/PDLLA is even more stable than common plate osteosynthesis in a small-hallow-bone-model. Further in vivo investigation should be performed to evaluate the surgical technique and long-term healing process of the bone and biodegradation process of the implant.


Assuntos
Implantes Absorvíveis , Fixação Intramedular de Fraturas/métodos , Fraturas Ósseas/cirurgia , Poliésteres/farmacologia , Fenômenos Biomecânicos , Placas Ósseas , Humanos
20.
J Arthroplasty ; 35(8): 2200-2203, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32247671

RESUMO

BACKGROUND: Recently, a revised definition of the minor criteria scoring system for diagnosing periprosthetic joint infection (PJI) was developed by the second International Consensus Meeting on musculoskeletal infection. The new system combines preoperative and intraoperative findings, reportedly achieving high sensitivity and specificity. We aimed to validate the modified scoring system at a high-volume center. METHODS: We retrospectively reviewed patients who underwent a revision total hip or knee arthroplasty at our institution from May 2015 to August 2018. Serum C-reactive protein, synovial white blood cell count and polymorphonuclear percentage, leukocyte esterase test, alpha-defensin, microbiological and histologic results, and documented existence of sinus tract and intraoperative purulence were available for all patients. Cases with at least 1 major criterion were considered as infected. Using the new minor criteria, a score of ≥6 reflects PJI, while a score <3 can be considered as noninfected. Sensitivity, specificity, mean accuracy (ACC), positive predictive value (PPV), and negative predictive value (NPV) were analyzed. RESULTS: A total of 345 cases were included. A cutoff score of ≥6 points had the following diagnostic performance: area under the curve (AUC) = 0.90; ACC = 0.88; sensitivity = 0.96; specificity = 0.84; PPV = 0.70; NPV = 0.98. Diagnostic performance was better for the hip (AUC = 0.92; ACC = 0.90; sensitivity = 0.96; specificity = 0.86; PPV = 0.81; NPV = 0.98) than the knee (AUC = 0.89; ACC = 0.85; sensitivity = 0.95; specificity = 0.83; PPV = 0.59; NPV = 0.98). CONCLUSION: The modified scoring system proposed by the 2018 International Consensus Meeting in diagnosing PJI showed high sensitivity and a good performance, especially as rule-out diagnostic criteria. The cutoff level seems to be different between the hip and knee. Further validation studies considering the acknowledged limitations are recommended.


Assuntos
Artroplastia de Quadril , Infecções Relacionadas à Prótese , Artroplastia de Quadril/efeitos adversos , Biomarcadores , Proteína C-Reativa/análise , Consenso , Humanos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/cirurgia , Estudos Retrospectivos , Sensibilidade e Especificidade , Líquido Sinovial/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...