Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 137
Filtrar
1.
Int J Cardiol ; : 132174, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38754590

RESUMO

BACKGROUND: Accurate assessment of aortic valve (AV) stenosis (AS) on transthoracic echocardiogram is crucial for appropriate clinical management. However, discordance between aortic valve area (AVA) and Doppler can complicate the diagnosis of severe AS in low-gradient (LG) AS phenotypes. METHODS: We reviewed 220 consecutive patients with suspected severe AS and AVA ≤1.0 cm2 on transthoracic echocardiogram who were evaluated for transcatheter AV replacement (TAVR) within a large health system from 2015 to 2019. We compared AV calcium score and aorta-mitral angle (AMA) on 3-chamber views from ECG-gated cardiovascular CT among patients with high-gradient (HG) AS (N = 18), paradoxical low-flow low-gradient (PLFLG) AS (N = 24) and normal-flow low-gradient (NFLG) AS (N = 14). RESULTS: All groups had comparable age, comorbidities, and AV calcium scores. Compared to patients with HG AS (mean AMA 120 ±â€¯10°), those with PLFLG AS (104 ±â€¯12°; p < 0.001) and NFLG AS (106 ±â€¯13°; p = 0.008) had narrower mean AMA values on cardiovascular CT. CONCLUSION: LG AS patients have significantly narrower AMA than HG AS patients on cardiovascular CT. Due to difficulty obtaining parallel Doppler alignment, narrower AMA may contribute to AVA-Doppler discordance on echocardiogram. These findings emphasize the need for additional information in the setting of LG AS.

2.
Echocardiography ; 41(2): e15774, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38329886

RESUMO

BACKGROUND: Guidelines recommend 3D echocardiography (3DE) to assess left ventricular ejection fraction (LVEF) on transthoracic echocardiogram (TTE) when possible, but it is unclear which factors are most strongly associated with reporting 3DE LVEF in real-world practice. METHODS: We evaluated 3DE LVEF reporting by age, sex, BMI, TTE location and variation in reporting by sonographer and reader. All TTEs were performed without contrast enhancement agent at a large medical center from 9/2015 to 12/2020 using ultrasound machines capable of 3DE. We used multivariable logistic regression to assess which factors were most associated with reporting 3DE LVEF. RESULTS: Among 35 641 TTEs included in this study, 57.4% were performed on women. 3DE LVEF was reported on 18 391 TTEs (51.6% of cohort; 50.5% for women and 52.4% for men). Portable inpatient TTEs (n = 5569) had the lowest rates of 3DE LVEF reporting (30.9%), while general outpatient TTEs (n = 15 933) had greater reporting (56.9%). Outpatient TTEs with an indication for chemotherapy (n = 3244) had the highest rates of 3DE LVEF (87.2%). The median (IQR) percentage of TTEs reporting 3D LVEF was 52.7% (43.1%-68.1%) among sonographers and 51.6% (46.5%-59.6%) among readers. Among 20082 (56.3%) TTEs with 3DE LVEF measured by sonographers, 91.6% were included by readers in the final report. After adjustment, performing sonographer in the highest reporting quartile was most strongly associated with reporting 3DE LVEF (OR 7.04, 95% CI 6.55-7.56), while an inpatient portable study had the strongest negative association for reporting (OR .38, 95% CI .35-.40). CONCLUSIONS: Use of 3DE LVEF in real-world practice varies substantially based on performing sonographer and is low for hospitalized patients, but can be frequently used for chemotherapy. Initiatives are needed to increase sonographer 3DE acquisition in most clinical settings.


Assuntos
Ecocardiografia Tridimensional , Função Ventricular Esquerda , Masculino , Humanos , Feminino , Volume Sistólico
3.
J Am Soc Echocardiogr ; 37(1): 2-63, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38182282

RESUMO

In patients with significant cardiac valvular disease, intervention with either valve repair or valve replacement may be inevitable. Although valve repair is frequently performed, especially for mitral and tricuspid regurgitation, valve replacement remains common, particularly in adults. Diagnostic methods are often needed to assess the function of the prosthesis. Echocardiography is the first-line method for noninvasive evaluation of prosthetic valve function. The transthoracic approach is complemented with two-dimensional and three-dimensional transesophageal echocardiography for further refinement of valve morphology and function when needed. More recently, advances in computed tomography and cardiac magnetic resonance have enhanced their roles in evaluating valvular heart disease. This document offers a review of the echocardiographic techniques used and provides recommendations and general guidelines for evaluation of prosthetic valve function on the basis of the scientific literature and consensus of a panel of experts. This guideline discusses the role of advanced imaging with transesophageal echocardiography, cardiac computed tomography, and cardiac magnetic resonance in evaluating prosthetic valve structure, function, and regurgitation. It replaces the 2009 American Society of Echocardiography guideline on prosthetic valves and complements the 2019 guideline on the evaluation of valvular regurgitation after percutaneous valve repair or replacement.


Assuntos
Doenças das Valvas Cardíacas , Coração , Adulto , Humanos , Imageamento por Ressonância Magnética , Ecocardiografia , Próteses e Implantes , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/cirurgia , Espectroscopia de Ressonância Magnética
5.
J Am Soc Echocardiogr ; 37(3): 276-284.e3, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37879379

RESUMO

OBJECTIVES: Prior data indicate a very rare risk of serious adverse drug reaction (ADR) to ultrasound enhancement agents (UEAs). We sought to evaluate the frequency of ADR to UEA administration in contemporary practice. METHODS: We retrospectively reviewed 4 US health systems to characterize the frequency and severity of ADR to UEA. Adverse drug reactions were considered severe when cardiopulmonary involvement was present and critical when there was loss of consciousness, loss of pulse, or ST-segment elevation. Rates of isolated back pain and headache were derived from the Mayo Clinic Rochester stress echocardiography database where systematic prospective reporting of ADR was performed. RESULTS: Among 26,539 Definity and 11,579 Lumason administrations in the Mayo Clinic Rochester stress echocardiography database, isolated back pain or headache was more frequent with Definity (0.49% vs 0.04%, P < .0001) but less common with Definity infusion versus bolus (0.08% vs 0.53%, P = .007). Among all sites there were 201,834 Definity and 84,943 Lumason administrations. Severe and critical ADR were more frequent with Lumason than with Definity (0.0848% vs 0.0114% and 0.0330% vs 0.0010%, respectively; P < .001 for each). Among the 3 health systems with >2,000 Lumason administrations, the frequency of severe ADR with Lumason ranged from 0.0755% to 0.1093% and the frequency of critical ADR ranged from 0.0293% to 0.0525%. Severe ADR rates with Definity were stable over time but increased in more recent years with Lumason (P = .02). Patients with an ADR to Lumason since the beginning of 2021 were more likely to have received a COVID-19 vaccination compared with matched controls (88% vs 75%; P = .05) and more likely to have received Moderna than Pfizer-Biotech (71% vs 26%, P < .001). CONCLUSION: Severe and critical ADR, while rare, were more frequent with Lumason, and the frequency has increased in more recent years. Additional work is needed to better understand factors, including associations with recently developed mRNA vaccines, which may be contributing to the increased rates of ADR to UEA since 2021.


Assuntos
Vacinas contra COVID-19 , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Fluorocarbonos , Humanos , Estudos Retrospectivos , Estudos Prospectivos , Incidência , Ecocardiografia , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/diagnóstico , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/epidemiologia , Cefaleia , Dor nas Costas
6.
Pregnancy Hypertens ; 34: 27-32, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37783090

RESUMO

OBJECTIVES: Continuous hemodynamic monitoring offers the opportunity to individualize management in severe preeclampsia (PEC). We compared cardiac output (CO) and total peripheral resistance (TPR) measured by bioreactance (NICOM), Clearsite™ Fingercuff [CS), and 3D-echocardiography (3DE). STUDY DESIGN: This prospective observational study included 12 pregnant patients with early PEC. CO and TPR were measured simultaneously by NICOM, CS, and 3DE antepartum and 1-2 days postpartum. Using 3DE as the standard, CS and NICOM interchangeability, precision, accuracy, and correlation were assessed. RESULTS: Compared to 3DE-CO, CS-CO was highly correlated (R2 = 0.70, p = <0.0001) with low percentage error (PE 29%) which met criteria for interchangeablity. CS-TPR had strong correlation (R2 = 0.81, p = <0.0001) and low PE (29%). While CS tended to slightly overestimate CO (bias + 2.05 ±1.18 L/min, limit of agreement (LOA) -0.20 to 4.31) and underestimate TPR (bias -279 ±156 dyes/sec/cm5; LOA -580 to 18.4) these differences were unlikely to be clinically significant. Thus CS could be interchangeable with 3DE for CO and TPR. NICOM-CO had only moderate correlation with 3DE-CO (R2 = 0.29, p = 0.01) with high PE (52%) above threshold for interchangeability. NICOM-CO had low mean bias (-1.2 ±1.68 L/min) but wide 95% LOA (-4.41 to 2.14) suggesting adequate accuracy but low precision in relation to 3DE-CO. NICOM-TPR had poor correlation with 3DE-TPR (R2 = 0.32, p = 0.001) with high PE (67%), relatively low mean bias (238 ±256), and wide 95% LOA (-655 to 1131). NICOM did not meet the criteria for interchangeable with 3DE for CO and TPR. CONCLUSIONS: Clearsite Fingercuff, but not NICOM, has potential to be clinically useful for CO and TPR monitoring in severe preeclampsia.


Assuntos
Monitorização Hemodinâmica , Pré-Eclâmpsia , Gravidez , Feminino , Humanos , Pré-Eclâmpsia/diagnóstico , Monitorização Fisiológica , Débito Cardíaco , Resistência Vascular
7.
J Am Soc Echocardiogr ; 36(1): 3-28, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36428195

RESUMO

Acute rheumatic fever and its chronic sequela, rheumatic heart disease (RHD), pose major health problems globally, and remain the most common cardiovascular disease in children and young people worldwide. Echocardiography is the most important diagnostic tool in recognizing this preventable and treatable disease and plays an invaluable role in detecting the presence of subclinical disease needing prompt therapy or follow-up assessment. This document provides recommendations for the comprehensive use of echocardiography in the diagnosis and therapeutic intervention of RHD. Echocardiographic diagnosis of RHD is made when typical findings of valvular and subvalvular abnormalities are seen, including commissural fusion, leaflet thickening, and restricted leaflet mobility, with varying degrees of calcification. The mitral valve is predominantly affected, most often leading to mitral stenosis. Mixed valve disease and associated cardiopulmonary pathology are common. The severity of valvular lesions and hemodynamic effects on the cardiac chambers and pulmonary artery pressures should be rigorously examined. It is essential to take advantage of all available modalities of echocardiography to obtain accurate anatomic and hemodynamic details of the affected valve lesion(s) for diagnostic and strategic pre-treatment planning. Intraprocedural echocardiographic guidance is critical during catheter-based or surgical treatment of RHD, as is echocardiographic surveillance for post-intervention complications or disease progression. The role of echocardiography is indispensable in the entire spectrum of RHD management.


Assuntos
Estenose da Valva Mitral , Febre Reumática , Cardiopatia Reumática , Criança , Humanos , Adolescente , Cardiopatia Reumática/diagnóstico por imagem , Ecocardiografia , Febre Reumática/complicações , Estenose da Valva Mitral/diagnóstico por imagem , Valva Mitral , Progressão da Doença
8.
PLoS One ; 17(12): e0277385, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36548259

RESUMO

BACKGROUND: Natural history of atrial and ventricular secondary mitral regurgitation (SMR) is poorly understood. We compared the impact of the degree of SMR on survival between atrial and ventricular dysfunction. METHODS: We conducted a retrospective cohort study of patients who underwent echocardiography in a healthcare network between 2013-2018. We compared the survival of patients with atrial and ventricular dysfunction, using propensity scores developed from differences in patient demographics and comorbidities within SMR severity strata (none, mild, moderate or severe). We fitted Cox proportional hazards models to estimate the risk-adjusted hazards of death across different severities of SMR between patients with atrial and ventricular dysfunction. RESULTS: Of 11,987 patients included (median age 69 years [IQR 58-80]; 46% women), 6,254 (52%) had isolated atrial dysfunction, and 5,733 (48%) had ventricular dysfunction. 3,522 patients were matched from each arm using coarsened exact matching. Hazard of death in atrial dysfunction without SMR was comparable to ventricular dysfunction without SMR (HR 1.1, 95% CI 0.9-1.3). Using ventricular dysfunction without SMR as reference, hazards of death remained higher in ventricular dysfunction than in atrial dysfunction across increasing severities of SMR: mild SMR (HR 2.1, 95% CI 1.8-2.4 in ventricular dysfunction versus HR 1.7, 95%CI 1.5-2.0 in atrial dysfunction) and moderate/severe SMR (HR 2.8, 95%CI 2.4-3.4 versus HR 2.4, 95%CI 2.0-2.9). CONCLUSIONS: SMR across all severities were associated with better survival in atrial dysfunction than in ventricular dysfunction, though the magnitude of the diminishing survival were similar between atrial and ventricular dysfunction in increasing severity of SMRs.


Assuntos
Fibrilação Atrial , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Humanos , Feminino , Idoso , Masculino , Fibrilação Atrial/complicações , Estudos Retrospectivos , Ecocardiografia , Disfunção Ventricular Esquerda/complicações , Resultado do Tratamento
9.
Am J Physiol Heart Circ Physiol ; 323(3): H559-H568, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35960632

RESUMO

Atrial cardiomyopathy has been recognized as having important consequences for cardiac performance and clinical outcomes. The pathophysiological role of the left atrial (LA) appendage and the effect of percutaneous left atrial appendage occlusion (LAAO) upon LA mechanics is incompletely understood. We evaluated if changes in LA stiffness due to endocardial LAAO can be detected by LA pressure-volume (PV) analysis and whether stiffness parameters are associated with baseline characteristics. Patients undergoing percutaneous endocardial LAAO (n = 25) were studied using a novel PV analysis using near-simultaneous three-dimensional LA volume measurements by transesophageal echocardiography (TEE) and direct invasive LA pressure measurements. LA stiffness (dP/dV, change in pressure with change in volume) was calculated before and after LAAO. Overall LA stiffness significantly increased after LAAO compared with baseline (median, 0.41-0.64 mmHg/mL; P ≪ 0.001). LA body stiffness after LAAO correlated with baseline LA appendage size by indexed maximum depth (Spearman's rank correlation coefficient Rs = 0.61; P < 0.01). LA stiffness change showed an even stronger correlation with baseline LA appendage size by indexed maximum depth (Rs = 0.70; P < 0.001). We found that overall LA stiffness increases after endocardial LAAO. Baseline LA appendage size correlates with the magnitude of increase and LA body stiffness. These findings document alteration of LA mechanics after endocardial LAAO and suggest that the LA appendage modulates overall LA compliance.NEW & NOTEWORTHY Our study documents a correlation of LA appendage remodeling with the degree of chronically abnormal LA body stiffness. In addition, we found that LA appendage size was the baseline parameter that best correlated with the magnitude of a further increase in overall LA stiffness after appendage occlusion. These findings offer insights about the LA appendage and LA mechanics that are relevant to patients at risk for adverse atrial remodeling, especially candidates for LA appendage occlusion.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Doenças Vasculares , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/etiologia , Cateterismo Cardíaco , Ecocardiografia Transesofagiana/métodos , Humanos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
10.
Echocardiography ; 39(6): 827-836, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35607253

RESUMO

INTRODUCTION AND OBJECTIVES: Mitral valve (MV) prolapse is highly prevalent in patients with atrial septal defect (ASD). Abnormal left ventricular geometry has been proposed as the main mechanism of MV prolapse in ASD, however, the changes in the morphology of the MV apparatus remain to be clarified. Our aim was to assess the MV geometry in patients with ASD and MV prolapse. METHODS: We evaluated 99 patients (73% female, median age 40 years) with ASD who underwent a three-dimensional transesophageal echocardiogram. Three-dimensional analysis of the MV was done using dedicated automated software. Transthoracic echocardiographic parameters were assessed post ASD closure in 28 patients. RESULTS: MV prolapse was found in 39% of patients. Although smaller left ventricular dimensions and greater interatrial shunt were found in patients with MV prolapse compared with those without prolapse, there was no difference in the subvalvular parameters. MV prolapse was associated with larger mitral anterior-posterior diameter, anterolateral-posteromedial diameter, anterior perimeter, posterior perimeter, total perimeter, and anterior leaflet area (all p < 0.05). Mitral regurgitation was more frequent in patients with MV prolapse (80 vs. 48%, p = 0.002). CONCLUSIONS: In patients with ASD, the main mechanism of MV prolapse is the presence of an organic primary process of the MV apparatus (excessive anterior mitral leaflet tissue and mitral annular enlargement).


Assuntos
Ecocardiografia Tridimensional , Comunicação Interatrial , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Adulto , Ecocardiografia , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Feminino , Comunicação Interatrial/complicações , Comunicação Interatrial/diagnóstico por imagem , Humanos , Masculino , Insuficiência da Valva Mitral/complicações , Prolapso da Valva Mitral/complicações , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso
11.
Am J Cardiol ; 172: 1-6, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35317929

RESUMO

Although there have been advances in ischemic heart disease (IHD) care, variation in IHD-related mortality trends across the United States has not been well described. We used the Centers for Disease Control and Prevention's Wide-ranging Online Data for Epidemiologic Research database to evaluate variation in IHD-related mortality for demographic groups in the United States between 1999 and 2019. Age-adjusted mortality rates (AAMRs) were stratified by gender, race, Hispanic ethnicity, and US state. Crude mortality rates were evaluated using 10-year age groups. IHD-related AAMRs decreased from 195 to 88 per 100,000 nationally, with slower a decrease from 2010 to 2019 (average annual percent change [AAPC] -2.6% [95% confidence interval -2.9% to -2.2%]) compared with 2002 to 2010 (AAPC -5.3% [95% confidence interval -5.6% to -4.9%]). All groups had decreases in AAMRs, although Black populations persistently had the highest AAMR, and women had greater relative decreases than men. AAPC was -3.7% for White men, -4.7% for White women, -3.9% for Black men, -4.9% for Black women, -4.1% for Hispanic men, and -5.1% for Hispanic women. Populations ≥65 years had greater relative mortality decreases than populations <65 years. The median AAMR (2019) and AAPC (1999 to 2019) across states was 86 (range 58 to 134) and -3.8% (range -1.7% to -4.8%), respectively. In conclusion, declines in IHD-related mortality have slowed in the United States, with a significant geographic variation. Black populations persistently had the highest AAMRs, and decreases were relatively greater for women and populations ≥65 years. The impact of demographics and geography on IHD should be further explored and addressed as part of public health measures.


Assuntos
Hispânico ou Latino , Isquemia Miocárdica , População Negra , Coleta de Dados , Etnicidade , Feminino , Humanos , Masculino , Estados Unidos/epidemiologia
12.
Eur Heart J Cardiovasc Imaging ; 23(7): 944-955, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35243501

RESUMO

AIMS: Atrial fibrillation (AF) is associated with atrial enlargement, mitral annulus (MA) and tricuspid annulus (TA) dilation, and atrial functional regurgitation (AFR). However, less is known about the impact of AF on both atrioventricular valves in those with normal and abnormal ventricular function. We aimed to compare the remodelling of the TA and MA in patients with non-valvular AF without significant AFR. METHODS AND RESULTS: Ninety-two patients referred for transoesophageal echocardiography were included and categorized into three groups: (i) AF with normal left ventricular (LV) function (Normal LV-AF), n = 36; (ii) AF with LV systolic dysfunction (LVSD-AF), n = 29; and (iii) Controls in sinus rhythm, n = 27. Three-dimensional MA and TA geometry were analysed using automated software. In patients with AF regardless of LV function, the MA and TA areas were larger compared with controls (LVSD-AF vs. Normal LV-AF vs. Controls, end-systolic MA: 5.2 ± 1.1 vs. 4.5 ± 0.7 vs. 3.9 ± 0.7 cm2/m2; end-systolic TA: 5.6 ± 1.3 vs. 5.3 ± 1.3 vs. 4.1 ± 0.7 cm2/m2; P < 0.05 for each comparison with Controls). TA and MA areas were not statistically different between the two AF groups. The TA increase over controls was greater than that of the MA in the Normal LV-AF group (27.7% vs. 15.6%, P = 0.041). Conversely, in the LVSD-AF group, MA and TA increased similarly (35.9% vs. 32.4%, P = 0.660). CONCLUSION: Patients with AF showed dilation of both TA and MA compared with patients in sinus rhythm. In patients with normal LV function, AF was associated with greater TA dilation than MA dilation whereas in patients with LVSD the TA and MA were equally dilated.


Assuntos
Fibrilação Atrial , Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Fibrilação Atrial/fisiopatologia , Ecocardiografia Tridimensional/métodos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia
13.
Artigo em Inglês | MEDLINE | ID: mdl-35064846

RESUMO

Percutaneous left atrial appendage (LAA) occlusion is increasingly performed in patients with atrial fibrillation and long-term contraindications for anticoagulation. Our aim was to evaluate the effects of LAA occlusion with the Watchman device on the geometry of the LAA orifice and assess its impact on the adjacent left upper pulmonary vein (LUPV) hemodynamics. We included 50 patients who underwent percutaneous LAA occlusion with the Watchman device and had acceptable three-dimensional transesophageal echocardiography images of LAA pre- and post-device placement. We measured offline the LAA orifice diameters in the long axis, and the minimum and maximum diameters, circumference, and area in the short axis view. Eccentricity index was calculated as maximum/minimum diameter ratio. The LUPV peak S and D velocities pre- and post-procedure were also measured. Patients were elderly (mean age 76 ± 8 years), 30 (60%) were men. There was a significant increase of all LAA orifice dimensions following LAA occlusion: diameter 1 (pre-device 18.1 ± 3.2 vs. post-device 21.5 ± 3.4 mm, p < 0.001), diameter 2 (20.6 ± 3.9 vs. 22.1 ± 3.6 mm, p < 0.001), minimum diameter (17.6 ± 3.1 vs. 21.3 ± 3.4 mm, p < 0.001), maximum diameter (21.5 ± 3.9 vs. 22.4 ± 3.6 mm, p = 0.022), circumference (63.6 ± 10.7 vs. 69.6 ± 10.5 mm, p < 0.001), and area (3.1 ± 1.1 vs. 3.9 ± 1.2 cm2, p < 0.001). Eccentricity index decreased after procedure (1.23 ± 0.16 vs. 1.06 ± 0.06, p < 0.001). LUPV peak S and D velocities did not show a significant difference (0.29 ± 0.15 vs. 0.30 ± 0.14 cm/s, p = 0.637; and 0.47 ± 0.19 vs. 0.48 ± 0.20 cm/s, p = 0.549; respectively). LAA orifice stretches significantly and it becomes more circular following LAA occlusion without causing a significant impact on the LUPV hemodynamics.

15.
Stroke ; 53(6): 1883-1891, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35086361

RESUMO

BACKGROUND: There are limited data about the epidemiology and secondary stroke prevention strategies used for patients with depressed left ventricular ejection fraction (LVEF) and sinus rhythm following an acute ischemic stroke (AIS). We sought to describe the prevalence of LVEF ≤40% and sinus rhythm among patients with AIS and antithrombotic treatment practice in a multi-center cohort from 2002 to 2018. METHODS: This was a multi-center, retrospective cohort study comprised of patients with AIS hospitalized in the Greater Cincinnati Northern Kentucky Stroke Study and 4 academic, hospital-based cohorts in the United States. A 1-stage meta-analysis of proportions was undertaken to calculate a pooled prevalence. Univariate analyses and an adjusted multivariable logistic regression model were performed to identify demographic, clinical, and echocardiographic characteristics associated with being prescribed an anticoagulant upon AIS hospitalization discharge. RESULTS: Among 14 338 patients with AIS with documented LVEF during the stroke hospitalization, the weighted pooled prevalence of LVEF ≤40% and sinus rhythm was 5.0% (95% CI, 4.1-6.0%; I2, 84.4%). Of 524 patients with no cardiac thrombus and no prior indication for anticoagulant who survived postdischarge, 200 (38%) were discharged on anticoagulant, 289 (55%) were discharged on antiplatelet therapy only, and 35 (7%) on neither. There was heterogeneity by site in the proportion discharged with an anticoagulant (22% to 45%, P<0.0001). Cohort site and National Institutes of Health Stroke Severity scale >8 (odds ratio, 2.0 [95% CI, 1.1-3.8]) were significant, independent predictors of being discharged with an anticoagulant in an adjusted analysis. CONCLUSIONS: Nearly 5% of patients with AIS have a depressed LVEF and are in sinus rhythm. There is significant variation in the clinical practice of antithrombotic therapy prescription by site and stroke severity. Given this clinical equipoise, further study is needed to define optimal antithrombotic treatment regimens for secondary stroke prevention in this patient population.


Assuntos
Fibrilação Atrial , AVC Isquêmico , Acidente Vascular Cerebral , Assistência ao Convalescente , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Fibrinolíticos/uso terapêutico , Humanos , Alta do Paciente , Prevalência , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda
16.
Pediatr Cardiol ; 43(4): 844-854, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34993558

RESUMO

Multisystem inflammatory syndrome in children (MIS-C) is one of the most significant sequela of coronavirus disease 2019 (COVID-19) in children. Emerging literature has described myocardial dysfunction in MIS-C patients using traditional and two-dimensional speckle tracking echocardiography in the acute phase. However, data regarding persistence of subclinical myocardial injury after recovery is limited. We aimed to detect these changes with deformation imaging, hypothesizing that left ventricular global longitudinal (GLS) and circumferential strain (GCS) would remain impaired in the chronic phase despite normalization of ventricular function parameters assessed by two-dimensional echocardiography. A retrospective, single-institution review of 22 patients with MIS-C was performed. Fractional shortening, GLS, and GCS, along with regional longitudinal (RLS) and circumferential strain (RCS) were compared across the acute, subacute, and chronic timepoints (presentation, 14-42, and > 42 days, respectively). Mean GLS improved from - 18.4% in the acute phase to - 20.1% in the chronic phase (p = 0.4). Mean GCS improved from - 19.4% in the acute phase to - 23.5% in the chronic phase (p = 0.03). RCS and RLS were impaired in the acute phase and showed a trend towards recovery by the chronic phase, with the exception of the basal anterolateral segment. In our longitudinal study of MIS-C patients, GLS and GCS were lower in the acute phase, corroborating with left ventricular dysfunction by traditional measures. Additionally, as function globally recovers, GLS and GCS also normalize. However, some regional segments continue to have decreased strain values which may be an important subclinical marker for future adverse events.


Assuntos
COVID-19 , Disfunção Ventricular Esquerda , COVID-19/complicações , Criança , Humanos , Estudos Longitudinais , Reprodutibilidade dos Testes , Estudos Retrospectivos , Síndrome de Resposta Inflamatória Sistêmica , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda
18.
Echocardiography ; 39(7): 985-1000, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-33305429

RESUMO

Three-dimensional echocardiography (3DE) has emerged in recent decades from a conceptual, research tool to an important, useful imaging technique that can informatively impact daily clinical practice. However, its adoption into the modern-day echo laboratory requires the acknowledgment of its value, coupled with proper leadership, education, and resources to implement and integrate its use with conventional echo techniques. 3DE integration involves important updates regarding equipment and patient selection, assimilation of 3D protocols into current clinical routine, laboratory workflow adaptation, storage, and reporting. This review will provide a practical blueprint and key points of how to integrate 3DE into today's echo laboratory, necessary resources to implement 3D workflow, logistical challenges that remain, and future directions to further improve assimilation of this relevant echo technique into the laboratory.


Assuntos
Ecocardiografia Tridimensional , Ecocardiografia Tridimensional/métodos , Humanos
19.
JACC Cardiovasc Interv ; 14(21): 2368-2374, 2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34736735

RESUMO

OBJECTIVES: The authors report the first clinical experience with the Conformal Left Atrial Appendage Seal (CLAAS) device. BACKGROUND: The CLAAS device was designed to address the limitations of first-generation left atrial appendage closure (LAAC) devices by providing an implant that is minimally traumatic, can be deployed in a noncoaxial fashion, and does not require postprocedural oral anticoagulation. METHODS: Patients with atrial fibrillation at high stroke risk (CHA2DS2-VASc score ≥2) were recruited using standard selection criteria. The LAAC procedure was guided by transesophageal echocardiography with patients under general anesthesia. The CLAAS device is composed of a foam cup, with a Nitinol endoskeleton with an expanded polytetrafluoroethylene cover, delivered with a standard delivery system using a tether for full recapture. All patients received dual-antiplatelet therapy for 6 months, followed by aspirin alone. Transesophageal echocardiographic follow-up was scheduled for 45 days and 1 year. RESULTS: Twenty-two patients (63.7% with CHA2DS2-VASc scores ≥3, 76.2% with HAS-BLED scores ≥3) were enrolled. The device was successfully implanted in 18 patients and unsuccessfully in 4 patients. There were no serious procedural complications. On transesophageal echocardiography performed at 45 days, 1 significant leak (≥5 mm) was seen, which was due to a large posterior lobe not appreciated at the time of implantation, and 1 device-related thrombus was noted, which resolved on oral anticoagulation. There were no periprocedural strokes, major pericardial effusions, or systemic or device embolization. CONCLUSIONS: This first-in-human study demonstrates the clinical feasibility of the CLAAS device for LAAC.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Acidente Vascular Cerebral , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/diagnóstico por imagem , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ecocardiografia Transesofagiana/efeitos adversos , Humanos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
20.
Circ Heart Fail ; 14(6)2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34422205

RESUMO

Right ventricular dysfunction is a hallmark of advanced pulmonary vascular, lung parenchymal, and left heart disease, yet the underlying mechanisms that govern (mal)adaptation remain incompletely characterized. Owing to the knowledge gaps in our understanding of the right ventricle (RV) in health and disease, the National Heart, Lung, and Blood Institute (NHLBI) commissioned a working group to identify current challenges in the field. These included a need to define and standardize normal RV structure and function in populations; access to RV tissue for research purposes and the development of complex experimental platforms that recapitulate the in vivo environment; and the advancement of imaging and invasive methodologies to study the RV within basic, translational, and clinical research programs. Specific recommendations were provided, including a call to incorporate precision medicine and innovations in prognosis, diagnosis, and novel RV therapeutics for patients with pulmonary vascular disease.


Assuntos
Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hipertensão Pulmonar/terapia , Circulação Pulmonar/fisiologia , Função Ventricular Direita/imunologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/fisiopatologia , National Heart, Lung, and Blood Institute (U.S.) , Estados Unidos , Disfunção Ventricular Direita/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...