Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Eur Radiol ; 34(4): 2689-2698, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37804340

RESUMO

OBJECTIVES: Visualizing left atrial anatomy including the pulmonary veins (PVs) is important for planning the procedure of pulmonary vein isolation with ablation in patients with atrial fibrillation (AF). The aims of our study are to investigate the feasibility of the 3D whole-heart bright-blood and black-blood phase-sensitive (BOOST) inversion recovery sequence in patients with AF scheduled for ablation or electro-cardioversion, and to analyze the correlation between image quality and heart rate and rhythm of patients. METHODS: BOOST was performed for assessing PVs both with T2 preparation pre-pulse (T2prep) and magnetization transfer preparation (MTC) in 45 patients with paroxysmal or permanent AF scheduled for ablation or electro-cardioversion. Image quality analyses were performed by two independent observers. Qualitative assessment was made using the Likert scale; for quantitative analysis, signal to noise ratios (SNR) and contrast to noise ratios (CNR) were calculated for each PV. Heart rate and rhythm were analyzed based on standard 12-lead ECGs. RESULTS: All MTC-BOOST acquisitions achieved diagnostic quality in the PVs, while a significant proportion of T2prep-BOOST images were not suitable for assessing PVs. SNR and CNR values of the MTC-BOOST bright-blood images were higher if patients had sinus rhythm. We found a significant or nearly significant negative correlation between heart rate and the SNR and CNR values of MTC-BOOST bright-blood images. CONCLUSION: 3D whole-heart MTC-BOOST bright-blood imaging is suitable for visualizing the PVs in patients with AF, producing diagnostic image quality in 100% of cases. However, image quality was influenced by heart rate and rhythm. CLINICAL RELEVANCE STATEMENT: The novel 3D whole-heart BOOST CMR sequence needs no contrast administration and is performed during free-breathing; therefore, it is easy to use for a wide range of patients and is suitable for visualizing the PVs in patients with AF. KEY POINTS: • The applicability of the novel 3D whole-heart bright-blood and black-blood phase-sensitive sequence to pulmonary vein imaging in clinical practice is unknown. • Magnetization transfer-bright-blood and black-blood phase-sensitive imaging is suitable for visualizing the pulmonary veins in patients with atrial fibrillation with excellent or good image quality. • Bright-blood and black-blood phase-sensitive cardiac magnetic resonance sequence is easy to use for a wide range of patients as it needs no contrast administration and is performed during free-breathing.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos de Viabilidade , Átrios do Coração/diagnóstico por imagem , Eletrocardiografia , Imageamento por Ressonância Magnética , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos
2.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37931067

RESUMO

AIMS: Cerebral thrombo-embolism is a dreaded complication of pulmonary vein isolation (PVI) for atrial fibrillation; its surrogate, silent cerebral embolism (SCE) can be detected by diffusion-weighted brain magnetic resonance imaging (bMRI). Initial investigations have raised a concern that very high-power, short-duration (vHPSD; 90 W/4 s) temperature-controlled PVI with the QDOT Micro catheter may be associated with a higher incidence of SCE compared with low-power long-duration ablation. We aimed to assess the incidence of procedural complications of vHPSD PVI with an emphasis on cerebral safety. METHODS AND RESULTS: We enrolled 328 consecutive patients undergoing their PVI procedure using vHPSD. A subgroup of 61 consecutive patients underwent diffusion-weighted bMRI within 24 h of the procedure, and incidence and predictors of SCE were studied. The mean procedure time and left atrial dwell time for the overall cohort were 69.6 ± 24.1 and 46.5 ± 21.5 min, respectively. First-pass isolation was achieved in 82%. No stroke or transient ischaemic attack occurred. Silent cerebral embolism was identified in 5 of 61 patients (8.2%). Silent cerebral embolism following procedures was significantly associated with lower baseline generator impedance (105.8 vs. 112.6 Ω, P < 0.0001) and with intermittent loss of catheter-tissue contact during ablation (14.1% vs. 6.1%, P < 0.0001). CONCLUSION: Very high-power, short-duration PVI is a safe technique with an excellent acute success rate. Silent cerebral embolism incidence in our cohort was below the previously reported range, with no clinically overt cerebral complications. Lower baseline generator impedance and loss of contact during ablation may contribute to a higher risk of SCEs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Embolia Intracraniana , Veias Pulmonares , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/epidemiologia , Incidência , Átrios do Coração , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Resultado do Tratamento
3.
Front Cardiovasc Med ; 10: 1177347, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37396587

RESUMO

Introduction: Left atrial appendage (LAA) thrombus is the most common source of embolization in atrial fibrillation (AF). Transesophageal echocardiography (TEE) is the gold standard method for LAA thrombus exclusion. Our pilot study aimed to compare the efficacy of a new non-contrast-enhanced cardiac magnetic resonance (CMR) sequence (BOOST) with TEE for the detection of LAA thrombus and to evaluate the usefulness of BOOST images for planning radiofrequency catheter ablation (RFCA) compared with left atrial (LA) contrast-enhanced computed tomography (CT). We also attempted to assess the patients' subjective experiences with TEE and CMR. Methods: Patients with AF undergoing either electrical cardioversion or RFCA were enrolled. Participants underwent pre-procedural TEE and CMR scans to evaluate LAA thrombus status and pulmonary vein anatomy. Patient experiences with TEE and CMR were assessed using a questionnaire developed by our team. Some patients scheduled for RFCA also had pre-procedural LA contrast-enhanced CT. In such cases, the operating physician was asked to subjectively define the quality of the CT and CMR scan on a scale of 1-10 (1 = worst, 10 = best) and comment on CMR's usefulness in RFCA planning. Results: Seventy-one patients were enrolled. In 94.4%, both TEE and CMR excluded, and in 1 patient, both modalities reported the presence of LAA thrombus. In 1 patient, TEE was inconclusive, but CMR excluded LAA thrombus. In 2 patients, CMR could not exclude the presence of thrombus, but in 1 of those cases, TEE was also indecisive. During TEE, 67%, during CMR, only 1.9% of patients reported pain (p < 0.0001), and 89% would prefer CMR in case of a repeat examination. The quality of the left atrial contrast-enhanced CT scans was better compared with the image quality of the CMR BOOST sequence [8 (7-9) vs. 6 (5-7), p < 0.0001]. Still, the CMR images were useful for procedural planning in 91% of cases. Conclusion: The new CMR BOOST sequence provides appropriate image quality for ablation planning. The sequence might be useful for excluding larger LAA thrombi; however, its accuracy in detecting smaller thrombi is limited. Most patients preferred CMR over TEE in this indication.

5.
Front Cardiovasc Med ; 9: 951943, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36277778

RESUMO

Aims: To evaluate the patient- and procedure-related predictors of transcatheter aortic-valve implantation (TAVI)-associated ischemic brain lesions and to assess the effect of silent cerebral ischemic lesions (SCIL) on neurocognitive function. Methods and results: We investigated 113 consecutive patients with severe aortic stenosis who underwent brain magnetic resonance imaging (MRI) within a week following TAVI. To assess periprocedural cerebral ischemic lesions, diffusion-weighted MRI was utilized. We used multivariate linear regression to identify the independent predictors of TAVI-related ischemic lesion volume (ILV) and periprocedural stroke. Neurocognitive evaluation was performed before and following TAVI at 6-month and one-year follow-up. Following TAVI, a total of 944 new cerebral ischemic lesions were detected in 104 patients (92%). The median ILV was 257 µl (interquartile range [IQR]:97.1-718.8µl) with a median lesion number of 6/patient [IQR:2-10]. The majority of ischemic lesions were clinically silent (95%), while 5% of the lesions induced a stroke, which was confirmed by MRI. Predilatation (ß = 1.13[95%CI:0.32-1.93], p = 0.01) and the number of valve positioning attempts during implantation (ß = 0.28[95%CI:0.06-0.50], p = 0.02) increased the log-transformed total ILV. Predilatation (OR = 12.04[95%CI:1.46-99.07], p = 0.02) and alternative access routes (OR = 7.84[95%CI:1.01-61.07], p = 0.02) were associated with stroke after adjustments for comorbidities and periprocedural factors. The presence of SCILs were not associated with a change in neurocognitive function that remained stable during the one-year follow-up. Conclusion: While periprocedural ischemic lesions are frequent, most of them are clinically silent and might not impact the patients' neurocognitive function. The number of valve positioning attempts, predilatation, and alternative access routes should be taken into consideration during TAVI to reduce the ILV and risk for stroke.

6.
BMC Cardiovasc Disord ; 22(1): 395, 2022 09 04.
Artigo em Inglês | MEDLINE | ID: mdl-36058933

RESUMO

BACKGROUND: Refractory cardiogenic shock is still a major clinical challenge with high mortality rates, although several devices can be used to conquer this event. These devices have different advantages and disadvantages originating from their insertion or cannulation method, therefore many complications can occur during their use. The aim of our study was to develop and create prototypes of a novel minimal invasively insertable, transapical cannula for surgical ventricular assist devices, which uniquely incorporates the inflow and outflow routes for the blood of the patient in itself, therefore it enables the use for only one cannula for patients in cardiogenic shock. METHODS: To define the available space for the planned cannula in the left ventricle and ascending aorta, we analyzed computed tomography scans of 24 heart failure patients, who were indicated to left ventricular assist device therapy. Parallel to these measurements, hydrodynamical calculations were performed to determine the sizes of the cannulas, which were necessary to provide effective cardiac output. RESULTS: After the designing steps, we produced prototypes of double-lumened, tube-in-tube apically insertable devices for three different patient groups, which included a separated venous and an arterial part using 3D modelling and printing technology. All the created cannulas are able to provide 5 l/min circulatory support. CONCLUSION: As a result of our research we created a sizing method based on the specific analysis of computed tomography pictures of end stage heart failure patients and a cannula concept, which can provide effective antegrade flow for patients in cardiogenic shock. We believe the improved version of our tool could have a significant therapeutic role in the future after further development based on animal and in vivo tests.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Animais , Cânula/efeitos adversos , Cateterismo Cardíaco , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Choque Cardiogênico/diagnóstico por imagem , Choque Cardiogênico/terapia
7.
J Clin Med ; 11(15)2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35956102

RESUMO

Nephroprotective imaging in peripheral arterial disease (PAD) is often crucial. We compared the diagnostic performance of non-contrast Quiescent-interval single-shot magnetic resonance angiography (QISS MRA) and carbon-dioxide digital subtraction angiography (CO2 DSA) in chronic lower extremity PAD patients. A 19-segment lower extremity arterial model was used to assess the degree of stenosis (none, <50%, 50−70%, >70%) and the image quality (5-point Likert scale: 1-non-diagnostic, 5-excellent image quality). Intra-class correlation coefficient (ICC) was calculated for inter-rater reliability. Diagnostic accuracy and interpretability were evaluated using CO2 DSA as a reference standard. 523 segments were evaluated in 28 patients (11 male, mean age: 71 ± 9 years). Median and interquartile range of subjective image quality parameters for QISS MRA were significantly better compared to CO2 DSA for all regions: (aortoiliac: 4 [4−5] vs. 3 [3−4]; femoropopliteal: 4 [4−5] vs. 4 [3−4]; tibioperoneal: 4 [3−5] vs. 3 [2−3]; all regions: 4 [4−5] vs. 3 [3−4], all p < 0.001). QISS MRA out-performed CO2 DSA regarding interpretability (98.3% vs. 86.0%, p < 0.001). Diagnostic accuracy parameters of QISS MRA for the detection of obstructive luminal stenosis (70%<) as compared to CO2 DSA were as follows: sensitivity 82.6%, specificity 96.9%, positive predictive value 89.1%, negative predictive value 94.8%. Regarding the degree of stenosis, interobserver variability for all regions was 0.97 for QISS MRA and 0.82 for CO2 DSA. QISS MRA proved to be superior to CO2 DSA regarding subjective image quality and interpretability for the imaging of chronic lower extremity PAD.

8.
Neuroradiology ; 64(12): 2343-2356, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35915181

RESUMO

PURPOSE: We assessed diffusion tensor imaging (DTI) metric changes of the corpus callosum and cingulum correlated to postprocedural ischemic lesion load (ILL) and cognitive performance in transcatheter aortic valve replacement (TAVR). METHODS: TAVR subjects had DTI post-TAVR (≤ 8 days) and at 6 months (78 participants, males 56%, age 78.8 years ± 6.3) and four neurocognitive tests (pre-TAVR, post-TAVR, 6 months, 1 year). DTI metrics (fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), radial diffusivity (RD)) were calculated for 7 regions: corpus callosum (genu, body, splenium) and cingulum (cingulate gyrus, parahippocampal cingulum bilaterally). DTI metrics post-TAVR and at 6 months were compared with Student's t-test (p < 0.0071) and ANOVA covarying for sex, ILL (p < 0.05) with post hoc analysis of ILL groups (p < 0.0167). Repeated-measures linear mixed-effect model (p < 0.05) was performed to investigate the effect of time and ILL on cognition. RESULTS: At 6 months, significant decrease of the following DTI metrics was detected: AD (genu, body, splenium, right parahippocampal cingulum: p ≤ 0.0046); MD (body, both cingulate gyri: p ≤ 0.0050); RD (left cingulate gyrus: p = 0.0021); FA (splenium: p < 0.0001). ANOVA confirmed significant effect of female sex on AD + MD reduction (body, right cingulate gyrus) and AD reduction (left cingulate gyrus) (p ≤ 0.0254). Significant negative effect of ILL on some DTI metric changes was found (AD + MD-body: p ≤ 0.0050; MD-left cingulate gyrus: p = 0.0087). Cognitive performance remained stable with significant negative correlation of ILL and retrograde memory and visual scores (p ≤ 0.0483). CONCLUSION: Significant effect of TAVR on cerebral microstructural integrity was found with reduced diffusivities opposite to the trends reported in various neurodegenerative conditions/ageing, notably in women and lower ILL, and with preserved/improved cognition. TRIAL REGISTRATION NUMBER: NCT02826200 at ClinicalTrials.gov; date of registration: 07. July 2016.


Assuntos
Lesões Encefálicas , Substituição da Valva Aórtica Transcateter , Substância Branca , Idoso , Feminino , Humanos , Masculino , Lesões Encefálicas/patologia , Cognição , Imagem de Tensor de Difusão/métodos , Estudos Prospectivos , Substância Branca/patologia
9.
J Clin Med ; 11(15)2022 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-35893427

RESUMO

Although reaching target heart rate (HR) before coronary CT angiography (CCTA) is still of importance, adequate HR control remains a challenge for many patients. Purpose-built cardiac scanners may provide optimal image quality at higher HRs by further improving temporal resolution. We aimed to compare the amount of motion artifacts on CCTA acquired using a dedicated cardiac CT (DCCT) compared to a conventional multidetector CT (MDCT) scanner. We compared 80 DCCT images to 80 MDCT scans matched by sex, age, HR, and coronary dominance. Image quality was graded on a per-patient, per-vessel and per-segment basis. Motion artifacts were assessed using Likert scores (1: non-diagnostic, 2: severe artifacts, 3: mild artifacts, 4: no artifacts). Patients were stratified into four groups according to HR (<60/min, 60−65/min, 66−70/min and >70/min). Overall, 2328 coronary segments were evaluated. DCCT demonstrated superior overall image quality compared to MDCT (3.7 ± 0.4 vs. 3.3 ± 0.7, p < 0.001). DCCT images yielded higher Likert scores in all HR ranges, which was statistically significant in the 60−65/min, 66−70/min and >70/min ranges (3.9 ± 0.2 vs. 3.7 ± 0.2, p = 0.008; 3.5 ± 0.5 vs. 3.1 ± 0.6, p = 0.048 and 3.5 ± 0.4 vs. 2.7 ± 0.7, p < 0.001, respectively). Using a dedicated cardiac scanner results in fewer motion artifacts, which may allow optimal image quality even in cases of high HRs.

10.
PLoS One ; 17(6): e0269807, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35696411

RESUMO

BACKGROUND: While patients with cardiac transthyretin amyloidosis are easily diagnosed with bone scintigraphy, the detection of cardiac light chain (AL) amyloidosis is challenging. Cardiac magnetic resonance (CMR) analyses play an essential role in the differential diagnosis of cardiomyopathies; however, limited data are available from cardiac AL-Amyloidosis. Hence, the purpose of the present study was to analyze the potential role of CMR in the detection of cardiac AL-amyloidosis. METHODS: We included 35 patients with proved cardiac AL-amyloidosis and two control groups constituted by 330 patients with hypertrophic cardiomyopathy (HCM) and 70 patients with arterial hypertension (HT), who underwent CMR examination. The phenotype and degree of left ventricular (LV) hypertrophy and the amount and pattern of late gadolinium enhancement (LGE) were evaluated. In addition, global and regional LV strain parameters were also analyzed using feature-tracking techniques. Sensitivity and specificity of several CMR parameters were analyzed in diagnosing cardiac AL-amyloidosis. RESULTS: The sensitivity and specificity of diffuse septal subendocardial LGE in diagnosing cardiac AL-amyloidosis was 88% and 100%, respectively. Likewise, the sensitivity and specificity of septal myocardial nulling prior to blood pool was 71% and 100%, respectively. In addition, a LV end-diastolic septal wall thickness ≥ 15 mm had an optimal diagnostic performance to differentiate cardiac AL-amyloidosis from HT (sensitivity 91%, specificity 89%). On the other hand, a reduced global LV longitudinal strain (< 15%) plus apical sparing (apex-to-base longitudinal strain > 2) had a very low sensitivity (6%) in detecting AL-Amyloidosis, but with very high specificity (100%). CONCLUSIONS: The findings from this study suggest that CMR could have an optimal diagnostic performance in the diagnosis of cardiac AL-amyloidosis. Hence, further larger studies are warranted to validate the findings from this study.


Assuntos
Neuropatias Amiloides Familiares , Cardiomiopatias , Amiloidose de Cadeia Leve de Imunoglobulina , Neuropatias Amiloides Familiares/patologia , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/patologia , Meios de Contraste , Gadolínio , Humanos , Hipertrofia Ventricular Esquerda/patologia , Amiloidose de Cadeia Leve de Imunoglobulina/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Miocárdio/patologia , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X
11.
Br J Sports Med ; 56(10): 553-560, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34848398

RESUMO

OBJECTIVES: To investigate the cardiovascular consequences of SARS-CoV-2 infection in highly trained, otherwise healthy athletes using cardiac magnetic resonance (CMR) imaging and to compare our results with sex-matched and age-matched athletes and less active controls. METHODS: SARS-CoV-2 infection was diagnosed by PCR on swab tests or serum immunoglobulin G antibody tests prior to a comprehensive CMR examination. The CMR protocol contained sequences to assess structural, functional and tissue-specific data. RESULTS: One hundred forty-seven athletes (94 male, median 23, IQR 20-28 years) after SARS-CoV-2 infection were included. Overall, 4.7% (n=7) of the athletes had alterations in their CMR as follows: late gadolinium enhancement (LGE) showing a non-ischaemic pattern with or without T2 elevation (n=3), slightly elevated native T1 values with or without elevated T2 values without pathological LGE (n=3) and pericardial involvement (n=1). Only two (1.4%) athletes presented with definite signs of myocarditis. We found pronounced sport adaptation in both athletes after SARS-CoV-2 infection and athlete controls. There was no difference between CMR parameters, including native T1 and T2 mapping, between athletes after SARS-CoV-2 infection and the matched athletic groups. Comparing athletes with different symptom severities showed that athletes with moderate symptoms had slightly greater T1 values than athletes with asymptomatic and mildly symptomatic infections (p<0.05). However, T1 mapping values remained below the cut-off point for most patients. CONCLUSION: Among 147 highly trained athletes after SARS-CoV-2 infection, cardiac involvement on CMR showed a modest frequency (4.7%), with definite signs of myocarditis present in only 1.4%. Comparing athletes after SARS-CoV-2 infection and healthy sex-matched and age-matched athletes showed no difference between CMR parameters, including native T1 and T2 values.


Assuntos
COVID-19 , Miocardite , Atletas , Meios de Contraste , Feminino , Gadolínio , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Masculino , Miocardite/diagnóstico por imagem , Miocárdio/patologia , Valor Preditivo dos Testes , SARS-CoV-2
12.
Eur J Radiol ; 145: 110032, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34800835

RESUMO

BACKGROUND: Filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR) are ubiquitously applied in the reconstruction of coronary CT angiography (CCTA) datasets. However, currently no data is available on the impact of a model-based adaptive filter (MBAF2), recently developed for a dedicated cardiac scanner. PURPOSE: Our aim was to determine the effect of MBAF2 on subjective and objective image quality parameters of coronary arteries on CCTA. METHODS: Images of 102 consecutive patients referred for CCTA were evaluated. Four reconstructions of coronary images (FBP, ASIR, MBAF2, ASIR + MBAF2) were co-registered and cross-section were assessed for qualitative (graininess, sharpness, overall image quality) and quantitative [image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)] image quality parameters. Image noise and signal were measured in the aortic root and the left main coronary artery, respectively. Graininess, sharpness, and overall image quality was assessed on a 4-point Likert scale. RESULTS: As compared to FBP, ASIR, and MBAF2, ASIR + MBAF2 resulted in reduced image noise [53.1 ± 12.3, 30.6 ± 8.5, 36.3 ± 4.2, 26.3 ± 4.0 Hounsfield units (HU), respectively; p < 0.001], improved SNR (8.4 ± 2.6, 14.1 ± 3.6, 11.8 ± 2.3, 16.3 ± 3.3 HU, respectively; p < 0.001) and CNR (9.4 ± 2.7, 15.9 ± 4.0, 13.3 ± 2.5, 18.3 ± 3.5 HU, respectively; p < 0.001). No difference in sharpness was observed amongst the reconstructions (p = 0.08). Although ASIR + MBAF2 was non-superior to ASIR regarding overall image quality (p = 0.99), it performed better than FBP (p < 0.001) and MBAF2 (p < 0.001) alone. CONCLUSION: The combination of ASIR and MBAF2 resulted in reduced image noise and improved SNR and CNR. The implementation of MBAF2 in clinical practice may result in improved noise reduction performance and could potentiate radiation dose reduction.


Assuntos
Angiografia por Tomografia Computadorizada , Interpretação de Imagem Radiográfica Assistida por Computador , Algoritmos , Angiografia Coronária , Humanos , Doses de Radiação , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
13.
Artigo em Inglês | MEDLINE | ID: mdl-34574691

RESUMO

BACKGROUND: The Olympic preparation of athletes has been highly influenced by COVID and post-COVID syndrome. As the complex screening of athletes is essential for safe and successful sports, we aimed to repeat the 2019-year sports cardiology screening of the Olympic Swim Team before the Olympics and to compare the results of COVID and non-COVID athletes. METHODS: Patient history, electrocardiogram, laboratory tests, body composition analysis, echocardiography, cardiopulmonary exercise test (CPET) were performed. We used time-ranking points to compare swimming performance. RESULTS: From April 2019, we examined 46 elite swimmers (24 ± 4 years). Fourteen swimmers had COVID infection; all cases were mild. During CPET there was no difference in the performance of COVID (male: VO2 max 55 ± 4 vs. 56.5 ± 5 mL/kg/min, p = 0.53; female: VO2 max 54.6 ± 4 vs. 56 ± 5.5 mL/kg/min, p = 0.86) vs. non-COVID athletes (male VO2 max 56.7 ± 5 vs. 55.5 ± 4.5 mL/kg/min, p = 0.50; female 49.6 ± 3 vs. 50.7 ± 2.6 mL/kg/min, p = 0.47) between 2019 and 2021. When comparing the time results of the National Championships, 54.8% of the athletes showed an improvement (p = 0.75). CONCLUSIONS: COVID infection with short-term detraining did not affect the performance of well-trained swimmers. According to our results, the COVID pandemic did not impair the effectiveness of the preparation for the Tokyo Olympics.


Assuntos
COVID-19 , Atletas , Feminino , Humanos , Masculino , SARS-CoV-2 , Natação , Tóquio
14.
Pathol Oncol Res ; 27: 630459, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34257596

RESUMO

Introduction: An important phase in surgical training is gaining experience in real human anatomical situations. When a cadaver is available it may complement the various artificial practice models. However, it is often necessary to supplement the characteristics of the cadavers with a simulation of a tumor. Our objective was to develop an easy-to-create, realistic artificial tumor-mimic model for peripheral lung tumor resection practice. Methods: In our work we injected barium sulphate enriched silicone suspension into 10 isolated, non-fixed lungs of human cadavers, through the puncture of the visceral pleura. Four lesions-apical, hilar and two peripheral-were created in each of ten specimens. After fixation CT scans were obtained and analyzed. The implanted tumor-mimics were examined after anatomical preparation and slicing. Also performed CT-guided percutaneous puncture was also performed to create the lesions in situ in two lungs of human cadavers. Results: Analyzing the CT data of 10 isolated lungs, out of 40 lesions, 34 were nodular (85.0%) and in the nodular group five were spiculated (12.5%). Satellite lesions were formed in two cases (5.0%). Relevant outflow into vessels or airway occurred in five lesions (12.5%). Reaching the surface of the lung occured in 11 lesions (27.5%). The tumor-mimics were elastic and adhered well to the surrounding tissue. The two lesions, implanted via percutaneous puncture, both were nodular and one also showed lobulated features. Conclusion: Our artificial tumor-mimics were easy to create, varied in shape and size, and with percutaneous implantation the lesions provide a model for teaching every step of a surgical procedure.


Assuntos
Neoplasias Pulmonares/patologia , Pulmão/patologia , Modelos Biológicos , Treinamento por Simulação/métodos , Procedimentos Cirúrgicos Operatórios/educação , Tomografia Computadorizada por Raios X/métodos , Cadáver , Humanos , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia
15.
Front Cardiovasc Med ; 8: 622118, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33763458

RESUMO

Three main mechanisms contribute to global right ventricular (RV) function: longitudinal shortening, radial displacement of the RV free wall (bellows effect), and anteroposterior shortening (as a consequence of left ventricular contraction). Since the importance of these mechanisms may vary in different cardiac conditions, a technology being able to assess their relative influence on the global RV pump function could help to clarify the pathophysiology and the mechanical adaptation of the chamber. Previously, we have introduced our 3D echocardiography (3DE)-based solution-the Right VentrIcular Separate wall motIon quantificatiON (ReVISION) method-for the quantification of the relative contribution of the three aforementioned mechanisms to global RV ejection fraction (EF). Since then, our approach has been applied in several clinical scenarios, and its strengths have been demonstrated in the in-depth characterization of RV mechanical pattern and the prognostication of patients even in the face of maintained RV EF. Recently, various new features have been implemented in our software solution to enable the convenient, standardized, and more comprehensive analysis of RV function. Accordingly, in our current technical paper, we aim to provide a detailed description of the latest version of the ReVISION method with special regards to the volumetric partitioning of the RV and the calculation of longitudinal, circumferential, and area strains using 3DE datasets. We also report the results of the comparison between 3DE- and cardiac magnetic resonance imaging-derived RV parameters, where we found a robust agreement in our advanced 3D metrics between the two modalities. In conclusion, the ReVISION method may provide novel insights into global and also segmental RV function by defining parameters that are potentially more sensitive and predictive compared to conventional echocardiographic measurements in the context of different cardiac diseases.

16.
Int J Cardiovasc Imaging ; 37(6): 2027-2036, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33555536

RESUMO

The prognosis of patients with hypertrophic cardiomyopathy (HCM) varies greatly. Cardiac magnetic resonance (CMR) is the gold standard method for assessing left ventricular (LV) mass and volumes. Myocardial fibrosis can be noninvasively detected using CMR. Moreover, feature-tracking (FT) strain analysis provides information about LV deformation. We aimed to investigate the prognostic significance of standard CMR parameters, myocardial fibrosis, and LV strain parameters in HCM patients. We investigated 187 HCM patients who underwent CMR with late gadolinium enhancement and were followed up. LV mass (LVM) was evaluated with the exclusion and inclusion of the trabeculae and papillary muscles (TPM). Global LV strain parameters and mechanical dispersion (MD) were calculated. Myocardial fibrosis was quantified. The combined endpoint of our study was all-cause mortality, heart transplantation, malignant ventricular arrhythmias and appropriate implantable cardioverter defibrillator (ICD) therapy. The arrhythmia endpoint was malignant ventricular arrhythmias and appropriate ICD therapy. The LVM index (LVMi) was an independent CMR predictor of the combined endpoint independent of the quantification method (p < 0.01). The univariate predictors of the combined endpoint were LVMi, global longitudinal (GLS) and radial strain and longitudinal MD (MDL). The univariate predictors of arrhythmia events included LVMi and myocardial fibrosis. More pronounced LV hypertrophy was associated with impaired GLS and increased MDL. More extensive myocardial fibrosis correlated with impaired GLS (p < 0.001). LVMi was an independent CMR predictor of major events, and myocardial fibrosis predicted arrhythmia events in HCM patients. FT strain analysis provided additional information for risk stratification in HCM patients.


Assuntos
Cardiomiopatia Hipertrófica , Meios de Contraste , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/patologia , Fibrose , Gadolínio , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Miocárdio/patologia , Valor Preditivo dos Testes , Prognóstico
17.
Int J Cardiol ; 331: 124-130, 2021 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-33577906

RESUMO

BACKGROUND: There is a lack of cardiac MRI information on left ventricular (LV) strain and rotational parameters of left ventricular noncompaction (LVNC) patients with reduced ejection fraction (EF). Thus, we sought to use feature tracking (FT) to describe these changes at different levels of EF deterioration. METHODS: We included 31 adult LVNC patients with reduced LV EF (Group B, EF < 50%) without any comorbidities or concomitant cardiac diseases, 31 age- and sex-matched LVNC patients with good EF (Group A, EF > 50%) and 31 healthy controls. Group B was divided according to LV EF into two subgroups (Group B-1: EF 35-50%, Group B-2: EF < 35%). Their global longitudinal, circumferential (GCS), and radial (GRS) strains; LV segmental strains; LV apical and basal rotation values; and patterns and degree of LV dyssynchrony were measured. RESULTS: All of the global and mean segmental strain parameters were significantly worse in Groups B, B-1 and B-2 than in Group A and in the controls. The LV mechanical dispersion increased as LV EF decreased. The degree of apical rotation was the highest in the control group, almost the same in Group A and the lowest and in the reverse direction in Group B-2. A rotational pattern, clockwise-directed rigid body rotation (RBR), was found in 39% of the Group B patients, and a counterclockwise-directed RBR was found in 26% of the Group A patients. CONCLUSIONS: The strain values and rotational parameters changed as the EF decreased. These changes affected the global LV, and we did not identify an LVNC-specific strain pattern.


Assuntos
Disfunção Ventricular Esquerda , Função Ventricular Esquerda , Adulto , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem
18.
Heart ; 106(13): 992-1000, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32447308

RESUMO

OBJECTIVE: We assessed the diagnostic and prognostic implications of early cardiac magnetic resonance (CMR), CMR-based deformation imaging and conventional risk factors in patients with troponin-positive acute chest pain and non-obstructed coronary arteries. METHODS: In total, 255 patients presenting between 2009 and 2019 with troponin-positive acute chest pain and non-obstructed coronary arteries who underwent CMR in ≤7 days were followed for a clinical endpoint of all-cause mortality. Cine movies, T2-weighted and late gadolinium-enhanced images were evaluated to establish a diagnosis of the underlying heart disease. Further CMR analysis, including left ventricular strain, was carried out. RESULTS: CMR (performed at a mean of 2.7 days) provided the diagnosis in 86% of patients (54% myocarditis, 22% myocardial infarction (MI) and 10% Takotsubo syndrome and myocardial contusion (n=1)). The 4-year mortality for a diagnosis of MI, myocarditis, Takotsubo and normal CMR patients was 10.2%, 1.6%, 27.3% and 0%, respectively. We found a strong association between CMR diagnosis and mortality (log-rank: 24, p<0.0001). Takotsubo and MI as the diagnosis, age, hypertension, diabetes, female sex, ejection fraction, stroke volume index and most of the investigated strain parameters were univariate predictors of mortality; however, in the multivariate analysis, only hypertension and circumferential mechanical dispersion measured by strain analysis were independent predictors of mortality. CONCLUSIONS: CMR performed in the early phase establishes the proper diagnosis in patients with troponin-positive acute chest pain and non-obstructed coronary arteries and provides additional prognostic factors. This may indicate that CMR could play an additional role in risk stratification in this patient population.


Assuntos
Angina Pectoris/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Contusões Miocárdicas/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Miocardite/diagnóstico por imagem , Cardiomiopatia de Takotsubo/diagnóstico por imagem , Troponina/sangue , Adulto , Idoso , Angina Pectoris/sangue , Angina Pectoris/mortalidade , Angina Pectoris/terapia , Biomarcadores/sangue , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/terapia , Bases de Dados Factuais , Diagnóstico Diferencial , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Contusões Miocárdicas/sangue , Contusões Miocárdicas/mortalidade , Contusões Miocárdicas/terapia , Infarto do Miocárdio/sangue , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/terapia , Miocardite/sangue , Miocardite/mortalidade , Miocardite/terapia , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Cardiomiopatia de Takotsubo/sangue , Cardiomiopatia de Takotsubo/mortalidade , Cardiomiopatia de Takotsubo/terapia , Fatores de Tempo , Adulto Jovem
19.
Int J Cardiovasc Imaging ; 35(9): 1683-1689, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31037474

RESUMO

The acquisition of short-axis (SA) cine magnetic resonance (MR) images after the administration of contrast agent (CA) is a common, time-saving technique, but a decreased difference in the blood-myocardium contrast on these steady-state free precession (SSFP) cine scans could change the calculated parameters when using threshold-based papillary and trabecular muscle (PTM) quantification. We studied the effect of CA on the parameters calculated from pre- and post-CA SA cine images in noncompaction cardiomyopathy (NC-CMP) and healthy (H) participants using a threshold-based module. A total of 39 individuals (20 patients and 19 healthy) were included prospectively in this study. After the pre-CA SA images were acquired, i.v. gadobutrol (GA) or gadobenate dimeglumine (GD) (GA vs. GD: NC-CMP = 12 vs. 8; C = 12 vs. 7) was administered, and SA scans were repeated after two minutes. A threshold-based PTM software was used for postprocessing. Pre-CA and post-CA SA images were analyzed, and the parameters were compared in both the NC-CMP and H groups. The left ventricular volumes were significantly larger, while the left ventricular myocardial (LVmass) and trabecular mass (LVtrab) values were significantly smaller on the post-CA scans (NC-CMP: pre-CA vs. post-CA, EDV: 74.0 ± 13.6 vs. 81.1 ± 16.3 ml/m2, ESV: 25.3 ± 7.3 vs. 30.1 ± 11.2 ml/m2, LVmass-ED: 82.5 ± 17.5 vs. 75.7 ± 15.9 g/m2, LVtrab-ED: 25.0 ± 6.6 vs. 18.9 ± 4.7 g/m2; Healthy: preCA vs. post-CA, EDV: 69.7 ± 11.9 vs. 72.2 ± 10.7 ml/m2, ESV: 22.6 ± 5.7 vs. 23.9 ± 6.3 ml/m2, LVmass-ED: 71.3 ± 13.6 vs. 68.7 ± 13.9 g/m2, LVtrab-ED: 19.4 ± 2.6 vs. 16.2 ± 3.0 g/m2; p < 0.05). The decreased blood-myocardium contrast difference on post-CA SSFP SA cine images leads to altered cardiac parameters when using threshold-based software for evaluation.


Assuntos
Meios de Contraste/administração & dosagem , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Miocárdio Ventricular não Compactado Isolado/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos/administração & dosagem , Software , Volume Sistólico , Função Ventricular Esquerda , Adulto , Fenômenos Biomecânicos , Estudos de Casos e Controles , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Miocárdio Ventricular não Compactado Isolado/fisiopatologia , Masculino , Meglumina/administração & dosagem , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
20.
PLoS One ; 14(2): e0211624, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30763323

RESUMO

BACKGROUND: We aimed to characterize gender specific left ventricular hypertrophy using a novel, accurate and less time demanding cardiac magnetic resonance (CMR) quantification method to differentiate physiological hypertrophy and hypertrophic cardiomyopathy based on a large population of highly trained athletes and hypertrophic cardiomyopathy patients. METHODS: Elite athletes (n = 150,>18 training hours/week), HCM patients (n = 194) and athletes with hypertrophic cardiomyopathy (n = 10) were examined by CMR. CMR based sport indices such as maximal end-diastolic wall thickness to left ventricular end-diastolic volume index ratio (EDWT/LVEDVi) and left ventricular mass to left ventricular end-diastolic volume ratio (LVM/LVEDV) were calculated, established using both conventional and threshold-based quantification method. RESULTS: Whereas 47.5% of male athletes, only 4.1% of female athletes were in the grey zone of hypertrophy (EDWT 13-16mm). EDWT/LVEDVi discriminated between physiological and pathological left ventricular hypertrophy with excellent diagnostic accuracy (AUCCQ:0.998, AUCTQ:0.999). Cut-off value for LVM/LVEDVCQ<0.82 mm×m2/ml and for EDWT/LVEDViTQ<1.27 discriminated between physiological and pathological left ventricular hypertrophy with a sensitivity of 77.8% and 89.2%, a specificity of 86.7% and 91.3%, respectively. LVM/LVEDV evaluated using threshold-based quantification performed significantly better than conventional quantification even in the male subgroup with EDWT between 13-16mm (p<0.001). CONCLUSIONS: Almost 50% of male highly trained athletes can reach EDWT of 13 mm. CMR based sport indices provide an important tool to distinguish hypertrophic cardiomyopathy from athlete's heart, especially in highly trained athletes in the grey zone of hypertrophy.


Assuntos
Cardiomiopatia Hipertrófica/fisiopatologia , Ventrículos do Coração/fisiopatologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Esportes/fisiologia , Atletas , Cardiomegalia/fisiopatologia , Cardiomegalia Induzida por Exercícios/fisiologia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...