Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Sens ; 4(3): 740-747, 2019 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-30773874

RESUMO

We present a new device called a double lateral heterojunction (DLH) as an ammonia sensor in humid atmosphere. It combines polyaniline derivatives in their poor conducting state with a highly conductive molecular material, lutetium bisphthalocyanine, LuPc2. Polyaniline and poly(2,5-dimethoxyaniline) are electrodeposited on ITO interdigitated electrodes, leading to an original device that can be obtained only by electrochemistry and not by other solution processing techniques. Both polymers lead to highly conducting materials that require a neutralization step before their coverage by LuPc2. While the device based on polyaniline shows ohmic behavior, the nonlinear I- V characteristics of the poly(2,5-dimethoxyaniline)-based DLH prove the existence of energy barriers at the interfaces, as demonstrated by impedance spectroscopy. It exhibits a particularly interesting sensitivity to ammonia, at room temperature and in a broad relative humidity range. Thanks to its higher energy barriers, the poly(2,5-dimethoxyaniline)/LuPc2 DLH is the most sensitive device with a limit of detection of 320 ppb. This work paves the way for the use of substituted polyanilines in conductometric sensors not only in the field of air quality monitoring but also in the field of health diagnosis by measurement in human breath.


Assuntos
Amônia/análise , Compostos de Anilina/química , Condutividade Elétrica , Galvanoplastia/instrumentação , Umidade , Limite de Detecção , Polímeros/química , Amônia/química , Semicondutores
2.
ACS Appl Mater Interfaces ; 10(23): 19974-19986, 2018 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-29737156

RESUMO

In this work, we report for the first time on a comprehensive study of poly(2,3,5,6-tetrafluoroaniline) (PTFANI). Contrary to the nonfluorinated polyaniline (PANI) or its analogues bearing one fluorine atom, PTFANI is a poorly conductive material. We present a comprehensive study of the electrosynthesized PTFANI from its monomer in an acidic aqueous medium. PTFANI was fully characterized by a potential-pH diagram, spectroelectrochemistry, and electrochemical quartz crystal microbalance (EQCM) measurements, as well as by a morphological study. Combined with the X-ray photoelectron spectroscopy (XPS) analysis, it allowed us to understand the redox properties of this polymer compared to those of the unsubstituted PANI. At pH < 1.85, no proton transfer occurred during the electrochemical process, but the insertion of anions at the site of the protonated imines was demonstrated through the EQCM and XPS experiments. PTFANI showed a lower ratio of 1 ClO4- per 3 2,3,5,6-tetrafluoroaniline units compared to that of PANI. The behavior at pH > 1.85 was different; no anion upload was observed during the electron transfer, but 1 H+ per electron was involved during the transition between the leucoemeraldine and emeraldine base forms. It should also be noted that the oxidation of the emeraldine into the pernigraniline form was not accessible in PTFANI because of the electron-withdrawing effects of the fluorine atoms. However, we took advantage of the unique behavior of PTFANI to build heterojunctions, by combining with a highly conductive molecular material, namely lutetium bisphthalocyanine, LuPc2. The obtained double-lateral heterojunction exhibited a particularly interesting sensitivity to ammonia, even under humid atmospheres, with a limit of detection of 450 ppb. This work paves the way for the use of PTFANI in other electronic devices and as a sensor not only in the field of air quality monitoring but also in the field of health diagnosis in measuring the human breath.

3.
Sensors (Basel) ; 14(8): 13476-95, 2014 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-25061841

RESUMO

We have prepared different hybrid polymer-phthalocyanine materials by solution processing, starting from two sulfonated phthalocyanines, s-CoPc and CuTsPc, and polyvinylpyrrolidone (PVP), polyethylene glycol (PEG), poly(acrylic acid-co-acrylamide) (PAA-AM), poly(diallyldimethylammonium chloride) (PDDA) and polyaniline (PANI) as polymers. We also studied the response to ammonia (NH3) of resistors prepared from these sensing materials. The solvent casted films, prepared from s-CoPc and PVP, PEG and PAA-AM, were highly insulating and very sensitive to the relative humidity (RH) variation. The incorporation of s-CoPc in PDDA by means of layer-by-layer (LBL) technique allowed to stabilize the film, but was too insulating to be interesting. We also prepared PANI-CuTsPc hybrid films by LBL technique. It allowed a regular deposition as evidenced by the linear increase of the absorbance at 688 nm as a function of the number of bilayers. The sensitivity to ammonia (NH3) of PANi-CuTsPc resistors was very high compared to that of individual materials, giving up to 80% of current decrease when exposed to 30 ppm NH3. Contrarily to what happens with neutral polymers, in PANI, CuTsPc was stabilized by strong electrostatic interactions, leading to a stable response to NH3, whatever the relative humidity in the range 10%-70%. Thus, the synergy of PANI with ionic macrocycles used as counteranions combined with their simple aqueous solution processing opens the way to the development of new gas sensors capable of operating in real world conditions.


Assuntos
Amônia/química , Atmosfera/química , Indóis/química , Polímeros/química , Soluções/química , Compostos de Anilina/química , Umidade , Interações Hidrofóbicas e Hidrofílicas , Isoindóis
4.
Talanta ; 97: 318-24, 2012 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-22841086

RESUMO

In this paper, we studied the effect of humidity on the response of cobalt phthalocyanine-containing resistors to ammonia, in the ppm range. We pointed out the fact that, when alternating exposure periods with recovery periods, the humidity effect had to be carefully studied, in correlation with the flow variation. Thus, for a sulfonated cobalt phthalocyanine, the effect of NH(3) was totally screened as soon as the relative humidity (RH) was above 10%. On the contrary, when using unsubstituted cobalt phthalocyanine (CoPc) as sensing material, the sensors' response to NH(3) appears to be quite stable in a wide RH range, allowing a discrimination between 12, 25 and 50 ppm of NH(3) over the 10-70% RH range. Finally, CoPc offers a promising perspective as sensing material for air quality control applications, even at relatively high humidity levels.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...