Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 10(6): e27188, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38500996

RESUMO

Limited data highlight the need to understand differences in SARS-CoV-2 omicron (B.1.1.529) variant viral load between the gold standard nasopharyngeal (NP) swab, mid-turbinate (MT)/anterior nasal swabs, oropharyngeal (OP) swabs, and saliva. MT, OP, and saliva samples from symptomatic individuals in Atlanta, GA, in January 2022 and longitudinal samples from a small familial cohort were tested by both RT-PCR and ultrasensitive antigen assays. Higher concentrations in the nares were observed in the familial cohort, but a dominant sample type was not found among 39 cases in the cross-sectional cohort. The composite of positive MT or OP assay for both RT-PCR and antigen assay trended toward higher diagnostic yield but did not achieve significant difference. Our data did not identify a singular preferred sample type for SARS-CoV-2 testing, but higher levels of saliva nucleocapsid, a trend toward higher yield of composite OP/MT result, and association of apparent MT or OP predominance with symptoms warrant further study.

2.
medRxiv ; 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37986832

RESUMO

Motivation: The motivation for this work was the need to establish a predefined cutoff based on genome copies per ml (GE/ml) rather than Ct, which can vary depending on the laboratory and assay used. A GE/ml-based threshold was necessary to define what constituted 'low positives" for samples that were included in data sets submitted to the FDA for emergency use approval for SARS-CoV-2 antigen tests. Summary: SARS-CoV-2, the causal agent of the global COVID-19 pandemic, made its appearance at the end of 2019 and is still circulating in the population. The pandemic led to an urgent need for fast, reliable, and widely available testing. After December 2020, the emergence of new variants of SARS-CoV-2 led to additional challenges since new and existing tests had to detect variants to the same extent as the original Wuhan strain. When an antigen-based test is submitted to the Food and Drug Administration (FDA) for Emergency Use Authorization (EUA) consideration it is benchmarked against PCR comparator assays, which yield cycle threshold (CT) data as an indirect indicator of viral load - the lower the CT, the higher the viral load of the sample and the higher the CT, the lower the viral load. The FDA mandates that 10-20% of clinical samples used to evaluate the antigen test have to be low positive. Low positive, as defined by the FDA, are clinical samples in which the CT of the SARS-CoV-2 target gene is within 3 CT of the mean CT value of the approved comparator test's Limit of Detection (LOD). While all comparator tests are PCR-based, the results from different PCR assays used are not uniform. Results vary depending on assay platform, target gene, LOD and laboratory methodology. The emergence and dominance of the Omicron variant further challenged this approach as the fraction of low positive clinical samples dramatically increased as compared to earlier SARS-CoV-2 variants. This led to 20-40% of clinical samples having high CT values and therefore assays vying for an EUA were failing to achieve the 80% Percent Positive Agreement (PPA) threshold required. Here we describe the methods and statistical analyses used to establish a predefined cutoff, based on genome copies per ml (GE/ml) to classify samples as low positive (less than the cutoff GE/ml) or high positive (greater than the cutoff GE/mL). CT 30 for the E gene target using Cobas® SARS-CoV-2-FluA/B platform performed at TriCore Reference Laboratories, and this low positive cutoff value was used for two EUA authorizations. Using droplet digital PCR and methods described here, a value 49,447.72 was determined as the GE/ml equivalent for the low positive cutoff. The CT cutoff corresponding to 49447.72 GE/ml was determined across other platforms and laboratories. The methodology and statistical analysis described here can now be used for standardization of all comparators used for FDA submissions with a goal towards establishing uniform criteria for EUA authorization.

3.
J Clin Microbiol ; 61(10): e0013823, 2023 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-37728336

RESUMO

Rapid antigen tests (RATs) have become an invaluable tool for combating the COVID-19 pandemic. However, concerns have been raised regarding the ability of existing RATs to effectively detect emerging SARS-CoV-2 variants. We compared the performance of 10 commercially available, emergency use authorized RATs against the Delta and Omicron SARS-CoV-2 variants using both individual patient and serially diluted pooled clinical samples. The RATs exhibited lower sensitivity for Omicron samples when using PCR cycle threshold (CT) value (a rough proxy for RNA concentration) as the comparator. Interestingly, however, they exhibited similar sensitivity for Omicron and Delta samples when using quantitative antigen concentration as the comparator. We further found that the Omicron samples had lower ratios of antigen to RNA, which offers a potential explanation for the apparent lower sensitivity of RATs for that variant when using C T value as a reference. Our findings underscore the complexity in assessing RAT performance against emerging variants and highlight the need for ongoing evaluation in the face of changing population immunity and virus evolution.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Pandemias , RNA
4.
J Clin Virol ; 162: 105426, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37028004

RESUMO

Widespread use of over-the-counter rapid diagnostic tests for SARS-CoV-2 has led to a decrease in availability of clinical samples for viral genomic surveillance. As an alternative sample source, we evaluated RNA isolated from BinaxNOW swabs stored at ambient temperature for SARS-CoV-2 rRT-PCR and full viral genome sequencing. 81 of 103 samples (78.6%) yielded detectable RNA, and 46 of 57 samples (80.7 %) yielded complete genome sequences. Our results illustrate that SARS-CoV-2 RNA extracted from used Binax test swabs provides an important opportunity for improving SARS-CoV-2 genomic surveillance, evaluating transmission clusters, and monitoring within-patient evolution.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , RNA Viral/genética , RNA Viral/análise , Técnicas de Diagnóstico Molecular , Sequenciamento Completo do Genoma/métodos
5.
medRxiv ; 2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36798414

RESUMO

Rapid Antigen Tests (RAT) have become an invaluable tool for combating the COVID-19 pandemic. However, concerns have been raised regarding the ability of existing RATs to effectively detect emerging SARS-CoV-2 variants. We compared the performance of eight commercially available, emergency use authorized RATs against the Delta and Omicron SARS-CoV-2 variants using individual patient and serially diluted pooled clinical samples. The RATs exhibited lower sensitivity for Omicron samples when using PCR Cycle threshold (C T ) value (a proxy for RNA concentration) as the comparator. Interestingly, however, they exhibited similar sensitivity for Omicron and Delta samples when using quantitative antigen concentration as the comparator. We further found that the Omicron samples had lower ratios of antigen to RNA, which offers a potential explanation for the apparent lower sensitivity of RATs for that variant when using C T value as a reference. Our findings underscore the complexity in assessing RAT performance against emerging variants and highlight the need for ongoing evaluation in the face of changing population immunity and virus evolution.

6.
medRxiv ; 2023 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-36712132

RESUMO

Widespread use of over-the-counter rapid diagnostic tests for SARS-CoV-2 has led to a decrease in availability of clinical samples for viral genomic surveillance. As an alternative sample source, we evaluated RNA isolated from BinaxNOW swabs stored at ambient temperature for SARS-CoV-2 rRT-PCR and full viral genome sequencing. 81 of 103 samples (78.6%) yielded detectable RNA, and 46 of 57 samples (80.7 %) yielded complete genome sequences. Our results illustrate that SARS-CoV-2 RNA extracted from used Binax test swabs provides an important opportunity for improving SARS-CoV-2 genomic surveillance, evaluating transmission clusters, and monitoring within-patient evolution.

7.
Cell ; 185(19): 3603-3616.e13, 2022 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-36084631

RESUMO

The effects of mutations in continuously emerging variants of SARS-CoV-2 are a major concern for the performance of rapid antigen tests. To evaluate the impact of mutations on 17 antibodies used in 11 commercially available antigen tests with emergency use authorization, we measured antibody binding for all possible Nucleocapsid point mutations using a mammalian surface-display platform and deep mutational scanning. The results provide a complete map of the antibodies' epitopes and their susceptibility to mutational escape. Our data predict no vulnerabilities for detection of mutations found in variants of concern. We confirm this using the commercial tests and sequence-confirmed COVID-19 patient samples. The antibody escape mutational profiles generated here serve as a valuable resource for predicting the performance of rapid antigen tests against past, current, as well as any possible future variants of SARS-CoV-2, establishing the direct clinical and public health utility of our system.


Assuntos
COVID-19 , SARS-CoV-2 , Animais , Anticorpos Neutralizantes , Anticorpos Antivirais , Epitopos/genética , Humanos , Mamíferos , Mutação , Nucleocapsídeo , SARS-CoV-2/genética
8.
medRxiv ; 2022 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-35169808

RESUMO

BACKGROUND: Upper respiratory samples for SARS-CoV-2 detection include the gold standard nasopharyngeal (NP) swab, and mid-turbinate (MT) nasal swabs, oropharyngeal (OP) swabs, and saliva. Following the emergence of the omicron (B.1.1.529) variant, limited preliminary data suggest that OP swabs or saliva samples may be more sensitive than nasal swabs, highlighting the need to understand differences in viral load across different sites. METHODS: MT, OP, and saliva samples were collected from symptomatic individuals presenting for evaluation in Atlanta, GA, in January 2022. Longitudinal samples were collected from a family cohort following COVID-19 exposure to describe detection of viral targets over the course of infection. RESULTS: SARS-CoV-2 RNA and nucleocapsid antigen measurements demonstrated a nares-predominant phenotype in a familial cohort. A consistent dominant location for SARS-CoV-2 was not found among 54 individuals. Positive percent agreement for virus detection in MT, OP and saliva specimens were 66.7 [54.1-79.2], 82.2 [71.1-93.4], and 72.5 [60.3-84.8] by RT-PCR, respectively, and 46.2 [32.6-59.7], 51.2 [36.2-66.1], and 72.0 [59.6-84.4] by ultrasensitive antigen assay. The composite of positive MT or OP assay was not significantly different than either alone for both RT-PCR and antigen assay (PPA 86.7 [76.7-96.6] and 59.5 [44.7-74.4], respectively). CONCLUSIONS: Our data suggest that SARS-CoV-2 nucleocapsid and RNA exhibited similar kinetics and diagnostic yield in three upper respiratory sample types across the duration of symptomatic disease. Collection of OP or combined nasal and OP samples does not appear to increase sensitivity versus validated nasal sampling for rapid detection of viral antigen.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...