Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Lett ; 47(14): 3552-3555, 2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35838728

RESUMO

A single-cycle light source in the near infrared is demonstrated enabling sensitive applications of ultrafast optical field control of electronic transport. The compact Er:fiber system generates passively phase-locked pulses with broadband spectra covering 150 THz to 350 THz at a duration of 4.2 fs and 40 MHz repetition rate. A second output arm is equipped with an electro-optic modulator (EOM) that switches the arrival time of the pulses by 700 ps at arbitrary frequencies up to 20 MHz, enabling timing modulation of the pump pulse without changing the average intensity. As a benchmark demonstration, we investigate the carrier relaxation dynamics in low-temperature-grown InGaAs (LT-InGaAs) using quantum interference currents (QuICs).

2.
Opt Express ; 29(21): 33632-33641, 2021 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-34809172

RESUMO

Moth-eye structures are patterned onto gallium selenide surfaces with sub-micrometer precision. In this way, Fresnel reflection losses are suppressed to below one percent within an ultrabroad optical bandwidth from 15 to 65 THz. We tune the geometry by rigorous coupled-wave analysis. Subsequently, ablation with a Ga+ ion beam serves to write optimized structures in areas covering 30 by 30 µm. The benefits are demonstrated via optical rectification of femtosecond laser pulses under tight focusing, resulting in emission of phase-stable transients in the mid-infrared. We analyze the performance of antireflection coating directly in the time domain by ultrabroadband electro-optic sampling.

3.
Opt Lett ; 45(17): 4714-4717, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32870839

RESUMO

The nonlinear transformation of fluctuations by frequency broadening is found to produce strong anti-correlations in the spectral output. This effect is investigated by dispersive Fourier transform measurements. We exploit the anti-correlations in order to cancel the intensity noise in a subsequent sum-frequency mixing step. This principle allows for the generation of tunable visible pulses by cascaded nonlinear mixing whilst maintaining the same intensity noise performance as the input pulses. In addition, we demonstrate that the power fluctuations occurring in the process of passive stabilization of the carrier-envelope phase locking via difference frequency generation may be cancelled by an analogous strategy.

4.
Anal Bioanal Chem ; 412(26): 7131-7140, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32794005

RESUMO

Proton transfer reaction time-of-flight mass spectrometry (PTR-ToF-MS) is a powerful tool for real-time monitoring of trace concentrations of volatile organic compounds (VOCs). The sensitivity of PTR-ToF-MS also depends on the ability to effectively focus and transmit ions from the relatively high-pressure drift tube (DT) to the low-pressure mass analyzer. In the present study, a modular ion-funnel (IF) is placed adjacent to the DT of a PTR-ToF-MS instrument to improve the ion-focusing. IF consists of a series of electrodes with gradually decreasing orifice diameters. Radio frequency (RF) voltage and direct current (DC) electric field are then applied to the electrodes to get the ions focused. We investigated the effect of the RF voltage and DC field on the sensitivity of a pattern of VOCs including hydrocarbons, alcohols, aldehydes, ketones, and aromatic compounds. In a proof-of-concept study, the instrument operating both as normal DT (DC-mode) and at optimal IF conditions (RF-mode) was applied for the breath analysis of 21 healthy human subjects. For the range of investigated VOCs, an improvement of one order of magnitude in sensitivity was observed in RF-mode compared with DC-mode. Limits of detection could be improved by a factor of 2-4 in RF-mode compared with DC-mode. Operating the instrument in RF-mode allowed the detection of more compounds in the exhaled air compared with DC-mode. Incorporation of the IF considerably improved the performance of PTR-ToF-MS allowing the real-time monitoring of a larger number of potential breath biomarkers. Graphical abstract.


Assuntos
Testes Respiratórios , Espectrometria de Massas/métodos , Compostos Orgânicos Voláteis/análise , Adulto , Feminino , Humanos , Íons , Limite de Detecção , Masculino , Pessoa de Meia-Idade , Estudo de Prova de Conceito , Adulto Jovem
5.
Light Sci Appl ; 9: 30, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32140221

RESUMO

Phase-stable electromagnetic pulses in the THz frequency range offer several unique capabilities in time-resolved spectroscopy. However, the diversity of their application is limited by the covered spectral bandwidth. In particular, the upper frequency limit of photoconductive emitters - the most widespread technique in THz spectroscopy - reaches only up to 7 THz in the regular transmission mode due to absorption by infrared-active optical phonons. Here, we present ultrabroadband (extending up to 70 THz) THz emission from an Au-implanted Ge emitter that is compatible with mode-locked fibre lasers operating at wavelengths of 1.1 and 1.55 µm with pulse repetition rates of 10 and 20 MHz, respectively. This result opens up the possibility for the development of compact THz photonic devices operating up to multi-THz frequencies that are compatible with Si CMOS technology.

6.
Front Chem ; 7: 401, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31263690

RESUMO

Soft chemical ionization mass spectrometric techniques, such as proton transfer reaction mass spectrometry (PTR-MS), are often used in breath analysis, being particularly powerful for real-time measurements. To ascertain the type and concentration of volatiles in exhaled breath clearly assignable product ions resulting from these volatiles need to be determined. This is difficult for compounds where isomers are common, and one important class of breath volatiles where this occurs are ketones. Here we present a series of extensive measurements on the reactions of H3O+ with a selection of ketones using PTR-MS. Of particular interest is to determine if ketone isomers can be distinguished without the need for pre-separation by manipulating the ion chemistry through changes in the reduced electric field. An additional issue for breath analysis is that the product ion distributions for these breath volatiles are usually determined from direct PTR-MS measurements of the compounds under the normal operating conditions of the instruments. Generally, no account is made for the effects on the ion-molecule reactions by the introduction of humid air samples or increased CO2 concentrations into the drift tubes of these analytical devices resulting from breath. Therefore, another motivation of this study is to determine the effects, if any, on the product ion distributions under the humid conditions associated with breath sampling. However, the ultimate objective for this study is to provide a valuable database of use to other researchers in the field of breath analysis to aid in analysis and quantification of trace amounts of ketones in human breath. Here we present a comprehensive compendium of the product ion distributions as a function of the reduced electric field for the reactions of H3O+. (H2O)n (n = 0 and 1) with nineteen ketones under normal and humid (100% relative humidity for 37 °C) PTR-MS conditions. The ketones selected for inclusion in this compendium are (in order of increasing molecular weight): 2-butanone; 2-pentanone; 3-pentanone; 2-hexanone; 3-hexanone; 2-heptanone; 3-heptanone; 4-heptanone; 3-octanone; 2-nonanone; 3-nonanone; 2-decanone; 3-decanone; cyclohexanone; 3-methyl-2-butanone; 3-methyl-2-pentanone; 2-methyl-3-pentanone; 2-methyl-3-hexanone; and 2-methyl-3-heptanone.

7.
Phytochemistry ; 154: 77-84, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30006091

RESUMO

In many Araceae both scent and heat production are known to temporally vary throughout anthesis, and in several species strong scents are released for pollinator attraction when thermogenesis is also strong. However, it is not known whether the temporal patterns of both scent emission and temperature are strictly synchronous and, for example, reach their maxima at the same time. We studied Arum maculatum, a brood-site deceptive species attracting its moth fly pollinators with strong fetid scents, to study temporal patterns in scent emission and temperature during anthesis. Inflorescence scents were collected and analysed by dynamic headspace and gas chromatography-mass spectrometry (GC-MS) or by proton-transfer-reaction-time-of-flight mass spectrometry (PTR-TOFMS), and the temperature of the appendix, which is the heating osmophore during pollinator attraction, was recorded by a thermocouple. We overall found that scent emission and temperature patterns were strongly correlated. However, in none of the seven studied individuals was the highest amount of scent released at times with the maximum temperature difference. Thus, patterns of scent emission and temperature are somewhat asynchronous suggesting that high scent emission rates and temporal scent patterns in plants with thermogenesis cannot be solely explained by temperature patterns. This calls for more in-depth studies to better understand the interplay between scent emission and thermogenesis.


Assuntos
Araceae/química , Inflorescência/química , Odorantes/análise , Temperatura , Compostos Orgânicos Voláteis/análise , Cromatografia Gasosa-Espectrometria de Massas
8.
Opt Lett ; 42(10): 2050-2053, 2017 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-28504746

RESUMO

Recent demonstrations of passively phase-locked fiber-based combs motivate broadband characterization of the noise associated with the stabilized carrier-envelope offset frequency. In our study, we analyze the phase noise of a 100 MHz Er:fiber system in a wide range spanning from microhertz to the Nyquist frequency. An interferometric detection method enables analysis of the high-frequency output of an f-to-2f interferometer. The dominant contribution of a broadband white noise floor at high frequencies attests quantum-limited performance. An out-of-loop measurement of the carrier-envelope phase reveals its jitter to be as low as 250 mrad when integrated over 12 orders of magnitude of the radio-frequency spectrum.

9.
Biotechnol J ; 12(6)2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28106351

RESUMO

Monitoring and control of pH is essential for the control of reaction conditions and reaction progress for any biocatalytic or biotechnological process. Microfluidic enzymatic reactors are increasingly proposed for process development, however typically lack instrumentation, such as pH monitoring. We present a microfluidic side-entry reactor (µSER) and demonstrate for the first time real-time pH monitoring of the progression of an enzymatic reaction in a microfluidic reactor as a first step towards achieving pH control. Two different types of optical pH sensors were integrated at several positions in the reactor channel which enabled pH monitoring between pH 3.5 and pH 8.5, thus a broader range than typically reported. The sensors withstood the thermal bonding temperatures typical of microfluidic device fabrication. Additionally, fluidic inputs along the reaction channel were implemented to adjust the pH of the reaction. Time-course profiles of pH were recorded for a transketolase and a penicillin G acylase catalyzed reaction. Without pH adjustment, the former showed a pH increase of 1 pH unit and the latter a pH decrease of about 2.5 pH units. With pH adjustment, the pH drop of the penicillin G acylase catalyzed reaction was significantly attenuated, the reaction condition kept at a pH suitable for the operation of the enzyme, and the product yield increased. This contribution represents a further step towards fully instrumented and controlled microfluidic reactors for biocatalytic process development.


Assuntos
Reatores Biológicos , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/métodos , Microfluídica , Biocatálise , Catálise , Ensaios Enzimáticos , Concentração de Íons de Hidrogênio , Cinética , Técnicas Analíticas Microfluídicas/instrumentação , Transcetolase/metabolismo
10.
Biosens Bioelectron ; 88: 188-195, 2017 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-27523821

RESUMO

The necessities of developing fast, portable, cheap and easy to handle pesticide detection platforms are getting attention of scientific and industrial communities. Although there are some approaches to develop microchip based pesticide detection platforms, there is no compact microfluidic device for the complementary, fast, cheap, reusable and reliable analysis of different pesticides. In this work, a microfluidic device is developed for in-situ analysis of pesticide concentration detected via metabolism/photosynthesis of Chlamydomonas reinhardtii algal cells (algae) in tap water. Algae are grown in glass based microfluidic chip, which contains integrated optical pH and oxygen sensors in a portable system for on-site detection. In addition, intrinsic algal fluorescence is detected to analyze the pesticide concentration in parallel to pH and oxygen sensors with integrated fluorescence detectors. The response of the algae under the effect of different concentrations of pesticides is evaluated and complementary inhibition effects depending on the pesticide concentration are demonstrated. The three different sensors allow the determination of various pesticide concentrations in the nanomolar concentration range. The miniaturized system provides the fast quantification of pesticides in less than 10min and enables the study of toxic effects of different pesticides on Chlamydomonas reinhardtii green algae. Consequently, the microfluidic device described here provides fast and complementary detection of different pesticides with algae in a novel glass based microfluidic device with integrated optical pH, oxygen sensors and algal fluorescence.


Assuntos
Técnicas Biossensoriais/instrumentação , Chlamydomonas reinhardtii/efeitos dos fármacos , Técnicas Analíticas Microfluídicas/instrumentação , Oxigênio/análise , Praguicidas/análise , Poluentes Químicos da Água/análise , Atrazina/análise , Atrazina/toxicidade , Chlamydomonas reinhardtii/fisiologia , Clorófitas/efeitos dos fármacos , Clorófitas/fisiologia , Diurona/análise , Diurona/toxicidade , Água Potável/análise , Desenho de Equipamento , Fluorescência , Concentração de Íons de Hidrogênio , Dispositivos Lab-On-A-Chip , Oxigênio/metabolismo , Praguicidas/toxicidade , Fotossíntese/efeitos dos fármacos , Simazina/análise , Simazina/toxicidade , Poluentes Químicos da Água/toxicidade
11.
Rapid Commun Mass Spectrom ; 30(6): 691-7, 2016 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-26864521

RESUMO

RATIONALE: Due to the recent rapid increase in electronic cigarette (e-cigarette) use worldwide, there is a strong scientific but also practical interest in analyzing e-cigarette aerosols. Most studies to date have used standardized but time-consuming offline technologies. Here a proof-of-concept for a fast online quantification setup based on proton transfer reaction mass spectrometry (PTR-MS) is presented. METHODS: The combination of a novel sampling interface with a time-of-flight PTR-MS instrument specially designed for three scenarios is introduced: (i) mainstream aerosol analysis (aerosol that the user inhales prior to exhalation), and analysis of exhaled breath following (ii) mouth-hold (no inhalation) and (iii) inhalation of e-cigarette aerosols. A double-stage dilution setup allows the various concentration ranges in these scenarios to be accessed. RESULTS: First, the instrument is calibrated for the three principal constituents of the e-cigarettes' liquids, namely propylene glycol, vegetable glycerol and nicotine. With the double-stage dilution the instrument's dynamic range was easily adapted to cover the concentration ranges obtained in the three scenarios: 20-1100 ppmv for the mainstream aerosol characterisation; 4-300 ppmv for the mouth-hold; and 2 ppbv to 20 ppmv for the inhalation experiment. CONCLUSIONS: It is demonstrated that the novel setup enables fast, high time resolution e-cigarette studies with online quantification. This enables the analysis and understanding of any puff-by-puff variations in e-cigarette aerosols. Large-scale studies involving a high number of volunteers will benefit from considerably higher sample throughput and shorter data processing times.

12.
Anal Bioanal Chem ; 407(25): 7757-63, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26253230

RESUMO

Proton transfer reaction mass spectrometry (PTR-MS) is a well-established technique for real-time analysis of volatile organic compounds (VOCs). Although it is extremely sensitive (with sensitivities of up to 4500 cps/ppbv, limits of detection <1 pptv and the response times of approximately 100 ms), the selectivity of PTR-MS is still somewhat limited, as isomers cannot be separated. Recently, selectivity-enhancing measures, such as manipulation of drift tube parameters (reduced electric field strength) and using primary ions other than H3O(+), such as NO(+) and O2 (+), have been introduced. However, monoterpenes, which belong to the most important plant VOCs, still cannot be distinguished so more traditional technologies, such as gas chromatography mass spectrometry (GC-MS), have to be utilised. GC-MS is very time consuming (up to 1 h) and cannot be used for real-time analysis. Here, we introduce a sensitive, near-to-real-time method for plant monoterpene research-PTR-MS coupled with fastGC. We successfully separated and identified six of the most abundant monoterpenes in plant studies (α- and ß-pinenes, limonene, 3-carene, camphene and myrcene) in less than 80 s, using both standards and conifer branch enclosures (Norway spruce, Scots pine and black pine). Five monoterpenes usually present in Norway spruce samples with a high abundance were separated even when the compound concentrations were diluted to 20 ppbv. Thus, fastGC-PTR-ToF-MS was shown to be an adequate one-instrument solution for plant monoterpene research.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Monoterpenos/análise , Picea/química , Pinus/química , Compostos Orgânicos Voláteis/análise , Monoterpenos Acíclicos , Alcenos/análise , Alcenos/isolamento & purificação , Monoterpenos Bicíclicos , Compostos Bicíclicos com Pontes/análise , Compostos Bicíclicos com Pontes/isolamento & purificação , Monoterpenos/isolamento & purificação , Prótons , Compostos Orgânicos Voláteis/isolamento & purificação , Volatilização
13.
J Mass Spectrom ; 50(2): 427-31, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25800025

RESUMO

In this study we demonstrate the potential of selective reagent ionisation-time of flight-mass spectrometry for the rapid and selective identification of a popular new psychoactive substance blend called 'synthacaine', a mixture that is supposed to imitate the sensory and intoxicating effects of cocaine. Reactions with H3O(+) result in protonated parent molecules which can be tentatively assigned to benzocaine and methiopropamine. However, by comparing the product ion branching ratios obtained at two reduced electric field values (90 and 170 Td) for two reagent ions (H3O(+) and NO(+)) to those of the pure chemicals, we show that identification is possible with a much higher level of confidence then when relying solely on the m/z of protonated parent molecules. A rapid and highly selective analytical identification of the constituents of a recreational drug is particularly crucial to medical personnel for the prompt medical treatment of overdoses, toxic effects or allergic reactions.


Assuntos
Drogas Ilícitas/análise , Espectrometria de Massas/métodos , Psicotrópicos/análise , Detecção do Abuso de Substâncias/métodos , Benzocaína/análise , Benzocaína/química , Drogas Ilícitas/química , Metanfetamina/análogos & derivados , Metanfetamina/análise , Metanfetamina/química , Psicotrópicos/química , Tiofenos/análise , Tiofenos/química
14.
Analyst ; 139(10): 2551-9, 2014 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-24695649

RESUMO

In this study we evaluate magnetic optical sensor particles (MOSePs) with incorporated sensing functionalities regarding their applicability in microfluidic devices. MOSePs can be separated from the surrounding solution to form in situ sensor spots within microfluidic channels, while read-out is accomplished outside the chip. These magnetic sensor spots exhibit benefits of sensor layers (high brightness and convenient usage) combined with the advantages of dispersed sensor particles (ease of integration). The accumulation characteristics of MOSePs with different diameters were investigated as well as the in situ sensor spot stability at varying flow rates. Magnetic sensor spots were stable at flow rates specific to microfluidic applications. Furthermore, MOSePs were optimized regarding fiber optic and imaging read-out systems, and different referencing schemes were critically discussed on the example of oxygen sensors. While the fiber optic sensing system delivered precise and accurate results for measurement in microfluidic channels, limitations due to analyte consumption were found for microscopic oxygen imaging. A compensation strategy is provided, which utilizes simple pre-conditioning by exposure to light. Finally, new application possibilities were addressed, being enabled by the use of MOSePs. They can be used for microscopic oxygen imaging in any chip with optically transparent covers, can serve as flexible sensor spots to monitor enzymatic activity or can be applied to form fixed sensor spots inside microfluidic structures, which would be inaccessible to integration of sensor layers.

15.
J Phys Chem A ; 118(37): 8229-36, 2014 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-24559481

RESUMO

We have investigated the reactions of NO(+), H3O(+), O2(+), and Kr(+) with picric acid (2,4,6 trinitrophenol, C6H3N3O7, PiA) using a time-of-flight mass spectrometer with a switchable reagent ion source. NO(+) forms a simple adduct ion PiA·NO(+), while H3O(+) reacts with PiA via nondissociative proton transfer to form PiAH(+). In contrast, both O2(+) and Kr(+) react with PiA by nondissociative charge transfer to produce PiA(+). For Kr(+), we also observe dissociation of PiA, producing NO2(+) with a branching percentage of approximately 40%. For the reagent ions H3O(+) and O2(+) (and operating the drift tube with normal laboratory air), we find that the intensities of the PiAH(+) and PiA(+) ions both exhibit a peak at a given drift-tube voltage (which is humidity dependent). This unusual behavior implies a peak in the detection sensitivity of PiA as a function of the drift-tube voltage (and hence E/N). Aided by electronic-structure calculations and our previous studies of trinitrotoluene and trinitrobenzene, we provide a possible explanation for the observed peak in the detection sensitivity of PiA.


Assuntos
Espectrometria de Massas/métodos , Picratos/análise , Indicadores e Reagentes/química , Criptônio/química , Óxido Nítrico/química , Oxigênio/química , Picratos/química , Teoria Quântica , Água/química
16.
Int J Mass Spectrom ; 360: 28-38, 2014 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-25844048

RESUMO

The rapid expansion in the number and use of new psychoactive substances presents a significant analytical challenge because highly sensitive instrumentation capable of detecting a broad range of chemical compounds in real-time with a low rate of false positives is required. A Selective Reagent Ionisation-Time of Flight-Mass Spectrometry (SRI-ToF-MS) instrument is capable of meeting all of these requirements. With its high mass resolution (up to m/Δm of 8000), the application of variations in reduced electric field strength (E/N) and use of different reagent ions, the ambiguity of a nominal (monoisotopic) m/z is reduced and hence the identification of chemicals in a complex chemical environment with a high level of confidence is enabled. In this study we report the use of a SRI-ToF-MS instrument to investigate the reactions of H3O+, O2+, NO+ and Kr+ with 10 readily available (at the time of purchase) new psychoactive substances, namely 4-fluoroamphetamine, methiopropamine, ethcathinone, 4-methylethcathinone, N-ethylbuphedrone, ethylphenidate, 5-MeO-DALT, dimethocaine, 5-(2-aminopropyl)benzofuran and nitracaine. In particular, the dependence of product ion branching ratios on the reduced electric field strength for all reagent ions was investigated and is reported here. The results reported represent a significant amount of new data which will be of use for the development of drug detection techniques suitable for real world scenarios.

17.
J Mass Spectrom ; 48(9): 1015-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24078242

RESUMO

The isomers 4-methylethcathinone and N-ethylbuphedrone are substitutes for the recently banned drug mephedrone. We find that with conventional proton transfer reaction mass spectrometry (PTR-MS), it is not possible to distinguish between these two isomers, because essentially for both substances, only the protonated molecules are observed at a mass-to-charge ratio of 192 (C12 H18NO(+)). However, when utilising an advanced PTR-MS instrument that allows us to switch the reagent ions (selective reagent ionisation) from H3O(+) (which is commonly used in PTR-MS) to NO(+), O2(+) and Kr(+), characteristic product (fragment) ions are detected: C4H10N(+) (72 Da) for 4-methylethcathinone and C5 H12N(+) (86 Da) for N-ethylbuphedrone; thus, selective reagent ionisation MS proves to be a powerful tool for fast detection and identification of these compounds.


Assuntos
Drogas Desenhadas/química , Espectrometria de Massas/métodos , Metanfetamina/análogos & derivados , Psicotrópicos/química , Indicadores e Reagentes , Íons/química , Isomerismo , Metanfetamina/química
18.
Rapid Commun Mass Spectrom ; 27(2): 325-32, 2013 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-23239380

RESUMO

RATIONALE: Security and protection against terrorist attacks are major issues in modern society. One especially challenging task is the monitoring and protection of air conditioning and heating systems of buildings against terrorist attacks with toxic chemicals. As existing technologies have low selectivity, long response times or insufficient sensitivity, there is a need for a novel approach such as we present here. METHODS: We have analyzed various chemical warfare agents (CWAs) and/or toxic industrial compounds (TICs) and related compounds, namely phosgene, diphosgene, chloroacetone, chloroacetophenone, diisopropylaminoethanol, and triethyl phosphate, utilizing a high-resolution proton-transfer-reaction time-of-flight mass spectrometry (PTR-TOFMS) instrument with the objective of finding key product ions and their intensities, which will allow a low-resolution quadrupole mass spectrometry based PTR-MS system to be used with high confidence in the assignment of threat agents in the atmosphere. RESULTS: We obtained high accuracy PTR-TOFMS mass spectra of the six compounds under study at two different values for the reduced electric field in the drift tube (E/N). From these data we have compiled a table containing product ions, and isotopic and E/N ratios for highly selective threat compound detection with a compact and cost-effective quadrupole-based PTR-MS instrument. Furthermore, using chloroacetophenone (tear gas), we demonstrated that this instrument's response is highly linear in the concentration range of typical Acute Exposure Guideline Levels (AEGLs). CONCLUSIONS: On the basis of the presented results it is possible to develop a compact and cost-effective PTR-QMS instrument that monitors air supply systems and triggers an alarm as soon as the presence of a threat agent is detected. We hope that this real-time surveillance device will help to seriously improve safety and security in environments vulnerable to terrorist attacks with toxic chemicals.

19.
J Mass Spectrom ; 47(9): 1092-7, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22972776

RESUMO

In this work, we illustrate the application of proton transfer reaction mass spectrometry (PTR-MS) in the field of food and drink safety. We present proof-of-principle measurements of four different drinks (water, tea, red wine and white wine) each spiked separately with four different date rape drugs (chloral hydrate, tricholorethanol, γ-butyrolactone and butanediol). At first, the ideal PTR-MS operating conditions (reduced electric field strength and monitoring the most abundant [fragment] ion) for detection of the drugs were determined utilizing a time-of-flight-based PTR-MS instrument. We then dissolved small quantities of the drugs (below the activation threshold for effects on humans) into the various types of drinks and detected them using a quadrupole-based PTR-MS instrument via two different sampling methods: (1) dynamic headspace sampling and (2) direct liquid injection. Both methods have their advantages and drawbacks. Only with dynamic headspace sampling can rape drug contaminations be detected within a timeframe of seconds, and therefore, this method is the most promising use of PTR-MS as a fast, sensitive and selective monitor for the detection of food and drink contamination.


Assuntos
Bebidas/análise , Hipnóticos e Sedativos/análise , Espectrometria de Massas/métodos , Detecção do Abuso de Substâncias/métodos , 4-Butirolactona/análise , Butileno Glicóis/análise , Hidrato de Cloral/análise , Estupro , Sensibilidade e Especificidade
20.
Anal Chem ; 84(9): 4161-6, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-22482459

RESUMO

Fears of terrorist attacks have led to the development of various technologies for the real-time detection of explosives, but all suffer from potential ambiguities in the assignment of threat agents. Using proton transfer reaction mass spectrometry (PTR-MS), an unusual bias dependence in the detection sensitivity of 2,4,6 trinitrotoluene (TNT) on the reduced electric field (E/N) has been observed. For protonated TNT, rather than decreasing signal intensity with increasing E/N, which is the more usual sensitivity pattern observed in PTR-MS studies, an anomalous behavior is first observed, whereby the signal intensity initially rises with increasing E/N. We relate this to unexpected ion-molecule chemistry based upon comparisons of measurements taken with related nitroaromatic compounds (1,3,5 trinitrobenzene, 1,3 dinitrobenzene, and 2,4 dinitrotoluene) and electronic structure calculations. This dependence provides an easily measurable signature that can be used to provide a rapid highly selective analytical procedure to minimize false positives for the detection of TNT. This has major implications for Homeland Security and, in addition, has the potential of making instrumentation cost-effective for use in security areas. This study shows that an understanding of fundamental ion-molecule chemistry occurring in low-pressure drift tubes is needed to exploit selectivity and sensitivity for analytical purposes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...