Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 297
Filtrar
1.
Abdom Radiol (NY) ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38744704

RESUMO

OBJECTIVE: Fully-automated CT-based algorithms for quantifying numerous biomarkers have been validated for unenhanced abdominal scans. There is great interest in optimizing the documentation and reporting of biophysical measures present on all CT scans for the purposes of opportunistic screening and risk profiling. The purpose of this study was to determine and adjust the effect of intravenous (IV) contrast on these automated body composition measures at routine portal venous phase post-contrast imaging. METHODS: Final study cohort consisted of 1,612 older adults (mean age, 68.0 years; 594 women) all imaged utilizing a uniform CT urothelial protocol consisting of pre-contrast, portal venous, and delayed excretory phases. Fully-automated CT-based algorithms for quantifying numerous biomarkers, including muscle and fat area and density, bone mineral density, and solid organ volume were applied to pre-contrast and portal venous phases. The effect of IV contrast upon these body composition measures was analyzed. Regression analyses, including square of the Pearson correlation coefficient (r2), were performed for each comparison. RESULTS: We found that simple, linear relationships can be derived to determine non-contrast equivalent values from the post-contrast CT biomeasures. Excellent positive linear correlation (r2 = 0.91-0.99) between pre- and post-contrast values was observed for all automated soft tissue measures, whereas moderate positive linear correlation was observed for bone attenuation (r2 = 0.58-0.76). In general, the area- and volume-based measurement require less adjustment than attenuation-based measures, as expected. CONCLUSION: Fully-automated quantitative CT-biomarker measures at portal venous phase abdominal CT can be adjusted to a non-contrast equivalent using simple, linear relationships.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38740719

RESUMO

PURPOSE: Lymph nodes (LNs) in the chest have a tendency to enlarge due to various pathologies, such as lung cancer or pneumonia. Clinicians routinely measure nodal size to monitor disease progression, confirm metastatic cancer, and assess treatment response. However, variations in their shapes and appearances make it cumbersome to identify LNs, which reside outside of most organs. METHODS: We propose to segment LNs in the mediastinum by leveraging the anatomical priors of 28 different structures (e.g., lung, trachea etc.) generated by the public TotalSegmentator tool. The CT volumes from 89 patients available in the public NIH CT Lymph Node dataset were used to train three 3D off-the-shelf nnUNet models to segment LNs. The public St. Olavs dataset containing 15 patients (out-of-training-distribution) was used to evaluate the segmentation performance. RESULTS: For LNs with short axis diameter ≥ 8 mm, the 3D cascade nnUNet model obtained the highest Dice score of 67.9 ± 23.4 and lowest Hausdorff distance error of 22.8 ± 20.2. For LNs of all sizes, the Dice score was 58.7 ± 21.3 and this represented a ≥ 10% improvement over a recently published approach evaluated on the same test dataset. CONCLUSION: To our knowledge, we are the first to harness 28 distinct anatomical priors to segment mediastinal LNs, and our work can be extended to other nodal zones in the body. The proposed method has the potential for improved patient outcomes through the identification of enlarged nodes in initial staging CT scans.

3.
ArXiv ; 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38711428

RESUMO

Accurate training labels are a key component for multi-class medical image segmentation. Their annotation is costly and time-consuming because it requires domain expertise. In our previous work, a dual-branch network was developed to segment single-class edematous adipose tissue. Its inputs include a few strong labels from manual annotation and many inaccurate weak labels from existing segmentation methods. The dual-branch network consists of a shared encoder and two decoders to process weak and strong labels. Self-supervision iteratively updates weak labels during the training process. This work aims to follow this strategy and automatically improve training labels for multi-class image segmentation. Instead of using weak and strong labels to only train the network once in the previous work, transfer learning is used to train the network and improve weak labels sequentially. The dual-branch network is first trained by weak labels alone to initialize model parameters. After the network is stabilized, the shared encoder is frozen, and strong and weak decoders are fine-tuned by strong and weak labels together. The accuracy of weak labels is iteratively improved in the fine-tuning process. The proposed method was applied to a three-class segmentation of muscle, subcutaneous and visceral adipose tissue on abdominal CT scans. Validation results on 11 patients showed that the accuracy of training labels was statistically significantly improved, with the Dice similarity coefficient of muscle, subcutaneous and visceral adipose tissue increased from 74.2% to 91.5%, 91.2% to 95.6%, and 77.6% to 88.5%, respectively (p<0.05). In comparison with our earlier method, the label accuracy was also significantly improved (p<0.05). These experimental results suggested that the combination of the dual-branch network and transfer learning is an efficient means to improve training labels for multi-class segmentation.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38758290

RESUMO

PURPOSE: Body composition measurements from routine abdominal CT can yield personalized risk assessments for asymptomatic and diseased patients. In particular, attenuation and volume measures of muscle and fat are associated with important clinical outcomes, such as cardiovascular events, fractures, and death. This study evaluates the reliability of an Internal tool for the segmentation of muscle and fat (subcutaneous and visceral) as compared to the well-established public TotalSegmentator tool. METHODS: We assessed the tools across 900 CT series from the publicly available SAROS dataset, focusing on muscle, subcutaneous fat, and visceral fat. The Dice score was employed to assess accuracy in subcutaneous fat and muscle segmentation. Due to the lack of ground truth segmentations for visceral fat, Cohen's Kappa was utilized to assess segmentation agreement between the tools. RESULTS: Our Internal tool achieved a 3% higher Dice (83.8 vs. 80.8) for subcutaneous fat and a 5% improvement (87.6 vs. 83.2) for muscle segmentation, respectively. A Wilcoxon signed-rank test revealed that our results were statistically different with p < 0.01. For visceral fat, the Cohen's Kappa score of 0.856 indicated near-perfect agreement between the two tools. Our internal tool also showed very strong correlations for muscle volume (R 2 =0.99), muscle attenuation (R 2 =0.93), and subcutaneous fat volume (R 2 =0.99) with a moderate correlation for subcutaneous fat attenuation (R 2 =0.45). CONCLUSION: Our findings indicated that our Internal tool outperformed TotalSegmentator in measuring subcutaneous fat and muscle. The high Cohen's Kappa score for visceral fat suggests a reliable level of agreement between the two tools. These results demonstrate the potential of our tool in advancing the accuracy of body composition analysis.

5.
BJR Artif Intell ; 1(1): ubae003, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38476957

RESUMO

The adoption of artificial intelligence (AI) tools in medicine poses challenges to existing clinical workflows. This commentary discusses the necessity of context-specific quality assurance (QA), emphasizing the need for robust QA measures with quality control (QC) procedures that encompass (1) acceptance testing (AT) before clinical use, (2) continuous QC monitoring, and (3) adequate user training. The discussion also covers essential components of AT and QA, illustrated with real-world examples. We also highlight what we see as the shared responsibility of manufacturers or vendors, regulators, healthcare systems, medical physicists, and clinicians to enact appropriate testing and oversight to ensure a safe and equitable transformation of medicine through AI.

6.
Comput Med Imaging Graph ; 114: 102363, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38447381

RESUMO

Reliable localization of lymph nodes (LNs) in multi-parametric MRI (mpMRI) studies plays a major role in the assessment of lymphadenopathy and staging of metastatic disease. Radiologists routinely measure the nodal size in order to distinguish benign from malignant nodes, which require subsequent cancer staging. However, identification of lymph nodes is a cumbersome task due to their myriad appearances in mpMRI studies. Multiple sequences are acquired in mpMRI studies, including T2 fat suppressed (T2FS) and diffusion weighted imaging (DWI) sequences among others; consequently, the sizing of LNs is rendered challenging due to the variety of signal intensities in these sequences. Furthermore, radiologists can miss potentially metastatic LNs during a busy clinical day. To lighten these imaging and workflow challenges, we propose a computer-aided detection (CAD) pipeline to detect both benign and malignant LNs in the body for their subsequent measurement. We employed the recently proposed Dynamic Head (DyHead) neural network to detect LNs in mpMRI studies that were acquired using a variety of scanners and exam protocols. The T2FS and DWI series were co-registered, and a selective augmentation technique called Intra-Label LISA (ILL) was used to blend the two volumes with the interpolation factor drawn from a Beta distribution. In this way, ILL diversified the samples that the model encountered during the training phase, while the requirement for both sequences to be present at test time was nullified. Our results showed a mean average precision (mAP) of 53.5% and a sensitivity of ∼78% with ILL at 4 FP/vol. This corresponded to an improvement of ≥10% in mAP and ≥12% in sensitivity at 4FP (p ¡ 0.05) respectively over current LN detection approaches evaluated on the same dataset. We also established the out-of-distribution robustness of the DyHead model by training it on data acquired by a Siemens Aera scanner and testing it on data from the Siemens Verio, Siemens Biograph mMR, and Philips Achieva scanners. Our pilot work represents an important first step towards automated detection, segmentation, and classification of lymph nodes in mpMRI.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Humanos , Metástase Linfática/diagnóstico por imagem , Metástase Linfática/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Linfonodos/diagnóstico por imagem , Estadiamento de Neoplasias
7.
ArXiv ; 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38529074

RESUMO

Pheochromocytomas and Paragangliomas (PPGLs) are rare adrenal and extra-adrenal tumors which have the potential to metastasize. For the management of patients with PPGLs, CT is the preferred modality of choice for precise localization and estimation of their progression. However, due to the myriad variations in size, morphology, and appearance of the tumors in different anatomical regions, radiologists are posed with the challenge of accurate detection of PPGLs. Since clinicians also need to routinely measure their size and track their changes over time across patient visits, manual demarcation of PPGLs is quite a time-consuming and cumbersome process. To ameliorate the manual effort spent for this task, we propose an automated method to detect PPGLs in CT studies via a proxy segmentation task. As only weak annotations for PPGLs in the form of prospectively marked 2D bounding boxes on an axial slice were available, we extended these 2D boxes into weak 3D annotations and trained a 3D full-resolution nnUNet model to directly segment PPGLs. We evaluated our approach on a dataset consisting of chest-abdomen-pelvis CTs of 255 patients with confirmed PPGLs. We obtained a precision of 70% and sensitivity of 64.1% with our proposed approach when tested on 53 CT studies. Our findings highlight the promising nature of detecting PPGLs via segmentation, and furthers the state-of-the-art in this exciting yet challenging area of rare cancer management.

8.
ArXiv ; 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38529079

RESUMO

Coronary artery calcification (CAC) is a strong and independent predictor of cardiovascular disease (CVD). However, manual assessment of CAC often requires radiological expertise, time, and invasive imaging techniques. The purpose of this multicenter study is to validate an automated cardiac plaque detection model using a 3D multiclass nnU-Net for gated and non-gated non-contrast chest CT volumes. CT scans were performed at three tertiary care hospitals and collected as three datasets, respectively. Heart, aorta, and lung segmentations were determined using TotalSegmentator, while plaques in the coronary arteries and heart valves were manually labeled for 801 volumes. In this work we demonstrate how the nnU-Net semantic segmentation pipeline may be adapted to detect plaques in the coronary arteries and valves. With a linear correction, nnU-Net deep learning methods may also accurately estimate Agatston scores on chest non-contrast CT scans. Compared to manual Agatson scoring, automated Agatston scoring indicated a slope of the linear regression of 0.841 with an intercept of +16 HU (R2 = 0.97). These results are an improvement over previous work assessing automated Agatston score computation in non-gated CT scans.

9.
ArXiv ; 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38529076

RESUMO

Multi-parametric MRI of the body is routinely acquired for the identification of abnormalities and diagnosis of diseases. However, a standard naming convention for the MRI protocols and associated sequences does not exist due to wide variations in imaging practice at institutions and myriad MRI scanners from various manufacturers being used for imaging. The intensity distributions of MRI sequences differ widely as a result, and there also exists information conflicts related to the sequence type in the DICOM headers. At present, clinician oversight is necessary to ensure that the correct sequence is being read and used for diagnosis. This poses a challenge when specific series need to be considered for building a cohort for a large clinical study or for developing AI algorithms. In order to reduce clinician oversight and ensure the validity of the DICOM headers, we propose an automated method to classify the 3D MRI sequence acquired at the levels of the chest, abdomen, and pelvis. In our pilot work, our 3D DenseNet-121 model achieved an F1 score of 99.5% at differentiating 5 common MRI sequences obtained by three Siemens scanners (Aera, Verio, Biograph mMR). To the best of our knowledge, we are the first to develop an automated method for the 3D classification of MRI sequences in the chest, abdomen, and pelvis, and our work has outperformed the previous state-of-the-art MRI series classifiers.

10.
ArXiv ; 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38529078

RESUMO

The skeletal region is one of the common sites of metastatic spread of cancer in the breast and prostate. CT is routinely used to measure the size of lesions in the bones. However, they can be difficult to spot due to the wide variations in their sizes, shapes, and appearances. Precise localization of such lesions would enable reliable tracking of interval changes (growth, shrinkage, or unchanged status). To that end, an automated technique to detect bone lesions is highly desirable. In this pilot work, we developed a pipeline to detect bone lesions (lytic, blastic, and mixed) in CT volumes via a proxy segmentation task. First, we used the bone lesions that were prospectively marked by radiologists in a few 2D slices of CT volumes and converted them into weak 3D segmentation masks. Then, we trained a 3D full-resolution nnUNet model using these weak 3D annotations to segment the lesions and thereby detected them. Our automated method detected bone lesions in CT with a precision of 96.7% and recall of 47.3% despite the use of incomplete and partial training data. To the best of our knowledge, we are the first to attempt the direct detection of bone lesions in CT via a proxy segmentation task.

11.
Br J Radiol ; 97(1156): 770-778, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38379423

RESUMO

OBJECTIVE: Assess automated CT imaging biomarkers in patients who went on to hip fracture, compared with controls. METHODS: In this retrospective case-control study, 6926 total patients underwent initial abdominal CT over a 20-year interval at one institution. A total of 1308 patients (mean age at initial CT, 70.5 ± 12.0 years; 64.4% female) went on to hip fracture (mean time to fracture, 5.2 years); 5618 were controls (mean age 70.3 ± 12.0 years; 61.2% female; mean follow-up interval 7.6 years). Validated fully automated quantitative CT algorithms for trabecular bone attenuation (at L1), skeletal muscle attenuation (at L3), and subcutaneous adipose tissue area (SAT) (at L3) were applied to all scans. Hazard ratios (HRs) comparing highest to lowest risk quartiles and receiver operating characteristic (ROC) curve analysis including area under the curve (AUC) were derived. RESULTS: Hip fracture HRs (95% CI) were 3.18 (2.69-3.76) for low trabecular bone HU, 1.50 (1.28-1.75) for low muscle HU, and 2.18 (1.86-2.56) for low SAT. 10-year ROC AUC values for predicting hip fracture were 0.702, 0.603, and 0.603 for these CT-based biomarkers, respectively. Multivariate combinations of these biomarkers further improved predictive value; the 10-year ROC AUC combining bone/muscle/SAT was 0.733, while combining muscle/SAT was 0.686. CONCLUSION: Opportunistic use of automated CT bone, muscle, and fat measures can identify patients at higher risk for future hip fracture, regardless of the indication for CT imaging. ADVANCES IN KNOWLEDGE: CT data can be leveraged opportunistically for further patient evaluation, with early intervention as needed. These novel AI tools analyse CT data to determine a patient's future hip fracture risk.


Assuntos
Fraturas do Quadril , Tomografia Computadorizada por Raios X , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Estudos Retrospectivos , Estudos de Casos e Controles , Tomografia Computadorizada por Raios X/métodos , Fraturas do Quadril/diagnóstico por imagem , Absorciometria de Fóton/métodos , Biomarcadores , Densidade Óssea/fisiologia
12.
ArXiv ; 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38410646

RESUMO

Recent studies indicate that Generative Pre-trained Transformer 4 with Vision (GPT-4V) outperforms human physicians in medical challenge tasks. However, these evaluations primarily focused on the accuracy of multi-choice questions alone. Our study extends the current scope by conducting a comprehensive analysis of GPT-4V's rationales of image comprehension, recall of medical knowledge, and step-by-step multimodal reasoning when solving New England Journal of Medicine (NEJM) Image Challenges - an imaging quiz designed to test the knowledge and diagnostic capabilities of medical professionals. Evaluation results confirmed that GPT-4V performs comparatively to human physicians regarding multi-choice accuracy (81.6% vs. 77.8%). GPT-4V also performs well in cases where physicians incorrectly answer, with over 78% accuracy. However, we discovered that GPT-4V frequently presents flawed rationales in cases where it makes the correct final choices (35.5%), most prominent in image comprehension (27.2%). Regardless of GPT-4V's high accuracy in multi-choice questions, our findings emphasize the necessity for further in-depth evaluations of its rationales before integrating such multimodal AI models into clinical workflows.

13.
ArXiv ; 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38410656

RESUMO

Purpose: Body composition measurements from routine abdominal CT can yield personalized risk assessments for asymptomatic and diseased patients. In particular, attenuation and volume measures of muscle and fat are associated with important clinical outcomes, such as cardiovascular events, fractures, and death. This study evaluates the reliability of an Internal tool for the segmentation of muscle and fat (subcutaneous and visceral) as compared to the well-established public TotalSegmentator tool. Methods: We assessed the tools across 900 CT series from the publicly available SAROS dataset, focusing on muscle, subcutaneous fat, and visceral fat. The Dice score was employed to assess accuracy in subcutaneous fat and muscle segmentation. Due to the lack of ground truth segmentations for visceral fat, Cohen's Kappa was utilized to assess segmentation agreement between the tools. Results: Our Internal tool achieved a 3% higher Dice (83.8 vs. 80.8) for subcutaneous fat and a 5% improvement (87.6 vs. 83.2) for muscle segmentation respectively. A Wilcoxon signed-rank test revealed that our results were statistically different with p < 0.01. For visceral fat, the Cohen's kappa score of 0.856 indicated near-perfect agreement between the two tools. Our internal tool also showed very strong correlations for muscle volume (R2=0.99), muscle attenuation (R2=0.93), and subcutaneous fat volume (R2=0.99) with a moderate correlation for subcutaneous fat attenuation (R2=0.45). Conclusion: Our findings indicated that our Internal tool outperformed TotalSegmentator in measuring subcutaneous fat and muscle. The high Cohen's Kappa score for visceral fat suggests a reliable level of agreement between the two tools. These results demonstrate the potential of our tool in advancing the accuracy of body composition analysis.

14.
Comput Med Imaging Graph ; 112: 102335, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38271870

RESUMO

Segmentation of multiple pelvic structures in MRI volumes is a prerequisite for many clinical applications, such as sarcopenia assessment, bone density measurement, and muscle-to-fat volume ratio estimation. While many CT-specific datasets and automated CT-based multi-structure pelvis segmentation methods exist, there are few MRI-specific multi-structure segmentation methods in literature. In this pilot work, we propose a lightweight and annotation-free pipeline to synthetically translate T2 MRI volumes of the pelvis to CT, and subsequently leverage an existing CT-only tool called TotalSegmentator to segment 8 pelvic structures in the generated CT volumes. The predicted masks were then mapped back to the original MR volumes as segmentation masks. We compared the predicted masks against the expert annotations of the public TCGA-UCEC dataset and an internal dataset. Experiments demonstrated that the proposed pipeline achieved Dice measures ≥65% for 8 pelvic structures in T2 MRI. The proposed pipeline is an alternative method to obtain multi-organ and structure segmentations without being encumbered by time-consuming manual annotations. By exploiting the significant research progress in CTs, it is possible to extend the proposed pipeline to other MRI sequences in principle. Our research bridges the chasm between the current CT-based multi-structure segmentation and MRI-based segmentation. The manually segmented structures in the TCGA-UCEC dataset are publicly available.


Assuntos
Processamento de Imagem Assistida por Computador , Pelve , Processamento de Imagem Assistida por Computador/métodos , Pelve/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Imageamento por Ressonância Magnética/métodos
15.
Int J Comput Assist Radiol Surg ; 19(3): 443-448, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38233598

RESUMO

PURPOSE: Edema, or swelling, is a common symptom of kidney, heart, and liver disease. Volumetric edema measurement is potentially clinically useful. Edema can occur in various tissues. This work focuses on segmentation and volume measurement of one common site, subcutaneous adipose tissue. METHODS: The density distributions of edema and subcutaneous adipose tissue are represented as a two-class Gaussian mixture model (GMM). In previous work, edema regions were segmented by selecting voxels with density values within the edema density distribution. This work improves upon the prior work by generating an adipose tissue mask without edema through a conditional generative adversarial network. The density distribution of the generated mask was imported into a Chan-Vese level set framework. Edema and subcutaneous adipose tissue are separated by iteratively updating their respective density distributions. RESULTS: Validation results on 25 patients with edema showed that the segmentation accuracy significantly improved. Compared to GMM, the average Dice Similarity Coefficient increased from 56.0 to 61.7% ([Formula: see text]) and the relative volume difference decreased from 36.5 to 30.2% ([Formula: see text]). CONCLUSION: The generated adipose tissue density prior improved edema segmentation accuracy. Accurate edema volume measurement may prove clinically useful.


Assuntos
Abdome , Insuficiência Cardíaca , Humanos , Edema/diagnóstico por imagem , Tecido Adiposo/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos
17.
Abdom Radiol (NY) ; 49(4): 1330-1340, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38280049

RESUMO

PURPOSE: To evaluate the relationship between socioeconomic disadvantage using national area deprivation index (ADI) and CT-based body composition measures derived from fully automated artificial intelligence (AI) tools to identify body composition measures associated with increased risk for all-cause mortality and adverse cardiovascular events. METHODS: Fully automated AI body composition tools quantifying abdominal aortic calcium, abdominal fat (visceral [VAT], visceral-to-subcutaneous ratio [VSR]), and muscle attenuation (muscle HU) were applied to non-contrast CT examinations in adults undergoing screening CT colonography (CTC). Patients were partitioned into 5 socioeconomic groups based on the national ADI rank at the census block group level. Pearson correlation analysis was performed to determine the association between national ADI and body composition measures. One-way analysis of variance was used to compare means across groups. Odds ratios (ORs) were generated using high-risk, high specificity (90% specificity) body composition thresholds with the most disadvantaged groups being compared to the least disadvantaged group (ADI < 20). RESULTS: 7785 asymptomatic adults (mean age, 57 years; 4361:3424 F:M) underwent screening CTC from April 2004-December 2016. ADI rank data were available in 7644 patients. Median ADI was 31 (IQR 22-43). Aortic calcium, VAT, and VSR had positive correlation with ADI and muscle attenuation had a negative correlation with ADI (all p < .001). Compared with the least disadvantaged group, mean differences for the most disadvantaged group (ADI > 80) were: Aortic calcium (Agatston) = 567, VAT = 27 cm2, VSR = 0.1, and muscle HU = -6 HU (all p < .05). Compared with the least disadvantaged group, the most disadvantaged group had significantly higher odds of having high-risk body composition measures: Aortic calcium OR = 3.8, VAT OR = 2.5, VSR OR = 2.0, and muscle HU OR = 3.1(all p < .001). CONCLUSION: Fully automated CT body composition tools show that socioeconomic disadvantage is associated with high-risk body composition measures and can be used to identify individuals at increased risk for all-cause mortality and adverse cardiovascular events.


Assuntos
Inteligência Artificial , Doenças Cardiovasculares , Adulto , Humanos , Pessoa de Meia-Idade , Cálcio , Composição Corporal , Tomografia Computadorizada por Raios X , Biomarcadores , Estudos Retrospectivos
18.
Abdom Radiol (NY) ; 49(2): 642-650, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38091064

RESUMO

PURPOSE: To detect and assess abdominal aortic aneurysms (AAAs) on CT in a large asymptomatic adult patient population using fully-automated deep learning software. MATERIALS AND METHODS: The abdominal aorta was segmented using a fully-automated deep learning model trained on 66 manually-segmented abdominal CT scans from two datasets. The axial diameters of the segmented aorta were extracted to detect the presence of AAAs-maximum axial aortic diameter greater than 3 cm were labeled as AAA positive. The trained system was then externally-validated on CT colonography scans of 9172 asymptomatic outpatients (mean age, 57 years) referred for colorectal cancer screening. Using a previously-validated automated calcified atherosclerotic plaque detector, we correlated abdominal aortic Agatston and volume scores with the presence of AAA. RESULTS: The deep learning software detected AAA on the external validation dataset with a sensitivity, specificity, and AUC of 96%, (95% CI 89%, 100%), 96% (96%, 97%), and 99% (98%, 99%) respectively. The Agatston and volume scores of reported AAA-positive cases were statistically significantly greater than those of reported AAA-negative cases (p < 0.0001). Using plaque alone as a AAA detector, at a threshold Agatston score of 2871, the sensitivity and specificity were 84% (73%, 94%) and 87% (86%, 87%), respectively. CONCLUSION: Fully-automated detection and assessment of AAA on CT is feasible and accurate. There was a strong statistical association between the presence of AAA and the quantity of abdominal aortic calcified atherosclerotic plaque.


Assuntos
Aneurisma da Aorta Abdominal , Placa Aterosclerótica , Adulto , Humanos , Pessoa de Meia-Idade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/epidemiologia , Aorta Abdominal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Sensibilidade e Especificidade
19.
Int J Comput Assist Radiol Surg ; 19(1): 163-170, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37326816

RESUMO

PURPOSE: Reliable measurement of lymph nodes (LNs) in multi-parametric MRI (mpMRI) studies of the body plays a major role in the assessment of lymphadenopathy and staging of metastatic disease. Previous approaches do not adequately exploit the complementary sequences in mpMRI to universally detect and segment lymph nodes, and they have shown fairly limited performance. METHODS: We propose a computer-aided detection and segmentation pipeline to leverage the T2 fat-suppressed (T2FS) and diffusion-weighted imaging (DWI) series from a mpMRI study. The T2FS and DWI series in 38 studies (38 patients) were co-registered and blended together using a selective data augmentation technique, such that traits of both series were visible in the same volume. A mask RCNN model was subsequently trained for universal detection and segmentation of 3D LNs. RESULTS: Experiments on 18 test mpMRI studies revealed that the proposed pipeline achieved a precision of [Formula: see text]%, sensitivity of [Formula: see text]% at 4 false positives (FP) per volume, and dice score of [Formula: see text]%. This represented an improvement of [Formula: see text]% in precision, [Formula: see text]% in sensitivity at 4 FP/volume, and [Formula: see text]% in dice score, respectively, over current approaches evaluated on the same dataset. CONCLUSION: Our pipeline universally detected and segmented both metastatic and non-metastatic nodes in mpMRI studies. At test time, the input data used by the trained model could either be the T2FS series alone or a blend of co-registered T2FS and DWI series. Contrary to prior work, this eliminated the reliance on both the T2FS and DWI series in a mpMRI study.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Pulmão , Mediastino , Linfonodos/diagnóstico por imagem , Linfonodos/patologia
20.
Abdom Radiol (NY) ; 49(1): 173-181, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37906271

RESUMO

RATIONALE AND OBJECTIVES: Measuring small kidney stones on CT is a time-consuming task often neglected. Volumetric assessment provides a better measure of size than linear dimensions. Our objective is to analyze the growth rate and prognosis of incidental kidney stones in asymptomatic patients on CT. MATERIALS AND METHODS: This retrospective study included 4266 scans from 2030 asymptomatic patients who underwent two or more nonenhanced CT scans for colorectal screening between 2004 and 2016. The DL software identified and measured the volume, location, and attenuation of 883 stones. The corresponding scans were manually evaluated, and patients without follow-up were excluded. At each follow-up, the stones were categorized as new, growing, persistent, or resolved. Stone size (volume and diameter), attenuation, and location were correlated with the outcome and growth rates of the stones. RESULTS: The stone cohort comprised 407 scans from 189 (M: 124, F: 65, median age: 55.4 years) patients. The median number of stones per scan was 1 (IQR: [1, 2]). The median stone volume was 17.1 mm3 (IQR: [7.4, 43.6]) and the median peak attenuation was 308 HU (IQR: [204, 532]. The 189 initial scans contained 291stones; 91 (31.3%) resolved, 142 (48.8%) grew, and 58 (19.9) remained persistent at the first follow-up. At the second follow-up (for 27 patients with 2 follow-ups), 14/44 (31.8%) stones had resolved, 19/44 (43.2%) grew and 11/44 (25%) were persistent. The median growth rate of growing stones was 3.3 mm3/year, IQR: [1.4,7.4]. Size and attenuation had a moderate correlation (Spearman rho 0.53, P < .001 for volume, and 0.50 P < .001 for peak attenuation) with the growth rate. Growing and persistent stones had significantly greater maximum axial diameter (2.7 vs 2.3 mm, P =.047) and peak attenuation (300 vs 258 HU, P =.031) CONCLUSION: We report a 12.7% prevalence of incidental kidney stones in asymptomatic adults, of which about half grew during follow-up with a median growth rate of about 3.3 mm3/year.


Assuntos
Cálculos Renais , Adulto , Humanos , Pessoa de Meia-Idade , Seguimentos , Estudos Retrospectivos , Cálculos Renais/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Rim
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...