Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 91(5): 2074-2088, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38192239

RESUMO

PURPOSE: Quantitative MRI techniques such as MR fingerprinting (MRF) promise more objective and comparable measurements of tissue properties at the point-of-care than weighted imaging. However, few direct cross-modal comparisons of MRF's repeatability and reproducibility versus weighted acquisitions have been performed. This work proposes a novel fully automated pipeline for quantitatively comparing cross-modal imaging performance in vivo via atlas-based sampling. METHODS: We acquire whole-brain 3D-MRF, turbo spin echo, and MPRAGE sequences three times each on two scanners across 10 subjects, for a total of 60 multimodal datasets. The proposed automated registration and analysis pipeline uses linear and nonlinear registration to align all qualitative and quantitative DICOM stacks to Montreal Neurological Institute (MNI) 152 space, then samples each dataset's native space through transformation inversion to compare performance within atlas regions across subjects, scanners, and repetitions. RESULTS: Voxel values within MRF-derived maps were found to be more repeatable (σT1 = 1.90, σT2 = 3.20) across sessions than vendor-reconstructed MPRAGE (σT1w = 6.04) or turbo spin echo (σT2w = 5.66) images. Additionally, MRF was found to be more reproducible across scanners (σT1 = 2.21, σT2 = 3.89) than either qualitative modality (σT1w = 7.84, σT2w = 7.76). Notably, differences between repeatability and reproducibility of in vivo MRF were insignificant, unlike the weighted images. CONCLUSION: MRF data from many sessions and scanners can potentially be treated as a single dataset for harmonized analysis or longitudinal comparisons without the additional regularization steps needed for qualitative modalities.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos
2.
J Magn Reson Imaging ; 59(5): 1758-1768, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37515516

RESUMO

PURPOSE: To explore whether MR fingerprinting (MRF) scans provide motion-robust and quantitative brain tissue measurements for non-sedated infants with prenatal opioid exposure (POE). STUDY TYPE: Prospective. POPULATION: 13 infants with POE (3 male; 12 newborns (age 7-65 days) and 1 infant aged 9-months). FIELD STRENGTH/SEQUENCE: 3T, 3D T1-weighted MPRAGE, 3D T2-weighted TSE and MRF sequences. ASSESSMENT: The image quality of MRF and MRI was assessed in a fully crossed, multiple-reader, multiple-case study. Sixteen image quality features in three types-image artifacts, structure and myelination visualization-were ranked by four neuroradiologists (8, 7, 5, and 8 years of experience respectively), using a 3-point scale. MRF T1 and T2 values in 8 white matter brain regions were compared between babies younger than 1 month and babies between 1 and 2 months. STATISTICAL TESTS: Generalized estimating equations model to test the significance of differences of regional T1 and T2 values of babies under 1 month and those older. MRI and MRF image quality was assessed using Gwet's second order auto-correlation coefficient (AC2) with confidence levels. The Cochran-Mantel-Haenszel test was used to assess the difference in proportions between MRF and MRI for all features and stratified by the type of features. A P value <0.05 was considered statistically significant. RESULTS: The MRF of two infants were excluded in T1 and T2 value analysis due to severe motion artifact but were included in the image quality assessment. In infants under 1 month of age (N = 6), the T1 and T2 values were significantly higher compared to those between 1 and 2 months of age (N = 4). MRF images showed significantly higher image quality ratings in all three feature types compared to MRI images. CONCLUSIONS: MR Fingerprinting scans have potential to be a motion-robust and efficient method for nonsedated infants. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 1.


Assuntos
Analgésicos Opioides , Processamento de Imagem Assistida por Computador , Recém-Nascido , Humanos , Masculino , Processamento de Imagem Assistida por Computador/métodos , Estudos Prospectivos , Imagens de Fantasmas , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
3.
Magn Reson Med ; 91(5): 1978-1993, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38102776

RESUMO

PURPOSE: To propose a new reconstruction method for multidimensional MR fingerprinting (mdMRF) to address shading artifacts caused by physiological motion-induced measurement errors without navigating or gating. METHODS: The proposed method comprises two procedures: self-calibration and subspace reconstruction. The first procedure (self-calibration) applies temporally local matrix completion to reconstruct low-resolution images from a subset of under-sampled data extracted from the k-space center. The second procedure (subspace reconstruction) utilizes temporally global subspace reconstruction with pre-estimated temporal subspace from low-resolution images to reconstruct aliasing-free, high-resolution, and time-resolved images. After reconstruction, a customized outlier detection algorithm was employed to automatically detect and remove images corrupted by measurement errors. Feasibility, robustness, and scan efficiency were evaluated through in vivo human brain imaging experiments. RESULTS: The proposed method successfully reconstructed aliasing-free, high-resolution, and time-resolved images, where the measurement errors were accurately represented. The corrupted images were automatically and robustly detected and removed. Artifact-free T1, T2, and ADC maps were generated simultaneously. The proposed reconstruction method demonstrated robustness across different scanners, parameter settings, and subjects. A high scan efficiency of less than 20 s per slice has been achieved. CONCLUSION: The proposed reconstruction method can effectively alleviate shading artifacts caused by physiological motion-induced measurement errors. It enables simultaneous and artifact-free quantification of T1, T2, and ADC using mdMRF scans without prospective gating, with robustness and high scan efficiency.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Algoritmos , Imagens de Fantasmas , Artefatos
4.
J Am Chem Soc ; 139(9): 3312-3315, 2017 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-28121424

RESUMO

Covalent conjugation of water-soluble polymers to proteins is critical for evading immune surveillance in the field of biopharmaceuticals. The most common and long-standing polymer modification is the attachment of methoxypoly(ethylene glycol) (mPEG), termed PEGylation, which has led to several clinically approved pharmaceuticals. Recent data indicate that brush-type polymers significantly enhance in vitro and in vivo properties. Herein, the polymer conformation of poly(ethylene glycol) is detailed and compared with those of water-soluble polyacrylate and polynorbornene (PNB) when attached to icosahedral virus-like particles. Small-angle neutron scattering reveals vastly different polymer conformations of the multivalent conjugates. Immune recognition of conjugated particles was evaluated versus PEGylated particles, and PNB conjugation demonstrated the most effective shielding from antibody recognition.


Assuntos
Acrilatos/química , Plásticos/química , Polietilenoglicóis/química , Vacinas de Partículas Semelhantes a Vírus/química , Animais , Camundongos , Modelos Moleculares , Estrutura Molecular , Difração de Nêutrons , Espalhamento a Baixo Ângulo
5.
Biomater Sci ; 4(5): 839-48, 2016 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-26906463

RESUMO

MAX8 ß-hairpin peptide hydrogel is a solid, preformed gel that can be syringe injected due to shear-thinning properties and can recover solid gel properties immediately after injection. This behavior makes the hydrogel an excellent candidate as a local drug delivery vehicle. In this study, vincristine, a hydrophobic and commonly used chemotherapeutic, is encapsulated within MAX8 hydrogel and shown to release constantly over the course of one month. Vincristine was observed to be cytotoxic in vitro at picomolar to nanomolar concentrations. The amounts of drug released from the hydrogels over the entire time-course were in this concentration range. After encapsulation, release of vincristine from the hydrogel was observed for four weeks. Further characterization showed the vincristine released during the 28 days remained biologically active, well beyond its half-life in bulk aqueous solution. This study shows that vincristine-loaded MAX8 hydrogels are excellent candidates as drug delivery vehicles, through sustained, low, local and effective release of vincristine to a specific target. Oscillatory rheology was employed to show that the shear-thinning and re-healing, injectable-solid properties that make MAX8 a desirable drug delivery vehicle are unaffected by vincristine encapsulation. Rheology measurements also were used to monitor hydrogel nanostructure before and after drug encapsulation.


Assuntos
Preparações de Ação Retardada/química , Sistemas de Liberação de Medicamentos , Hidrogéis/química , Peptídeos/química , Antineoplásicos/química , Linhagem Celular Tumoral , Sobrevivência Celular , Portadores de Fármacos/química , Meia-Vida , Humanos , Interações Hidrofóbicas e Hidrofílicas , Injeções , Reologia , Espalhamento a Baixo Ângulo , Vincristina/química
6.
Nat Chem ; 8(1): 33-41, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26673262

RESUMO

Gels formed via metal-ligand coordination typically have very low branch functionality, f, as they consist of ∼2-3 polymer chains linked to single metal ions that serve as junctions. Thus, these materials are very soft and unable to withstand network defects such as dangling ends and loops. We report here a new class of gels assembled from polymeric ligands and metal-organic cages (MOCs) as junctions. The resulting 'polyMOC' gels are precisely tunable and may feature increased branch functionality. We show two examples of such polyMOCs: a gel with a low f based on a M2L4 paddlewheel cluster junction and a compositionally isomeric one of higher f based on a M12L24 cage. The latter features large shear moduli, but also a very large number of elastically inactive loop defects that we subsequently exchanged for functional ligands, with no impact on the gel's shear modulus. Such a ligand substitution is not possible in gels of low f, including the M2L4-based polyMOC.


Assuntos
Géis/química , Compostos Organometálicos/química , Polímeros/química , Elasticidade , Géis/síntese química , Ligantes , Simulação de Dinâmica Molecular , Compostos Organometálicos/síntese química , Polímeros/síntese química , Propriedades de Superfície
7.
Integr Biol (Camb) ; 4(1): 84-92, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22120019

RESUMO

Integrins play a key role in cell-cell and cell-matrix interactions. Artificial surfaces grafted with integrin ligands, mimicking natural interfaces, have been used to study integrin-mediated cell adhesion. Here we report the use of a new chemical engineering technology in combination with single-molecule nanomechanical measurements to quantify peptide binding to integrins. We prepared latex beads with covalently-attached dextran. The beads were then functionalized with the bioactive peptides, cyclic RGDFK (cRGD) and the fibrinogen γC-dodecapeptide (H12), corresponding to the active sites for fibrinogen binding to the platelet integrin αIIbß3. Using optical tweezers-based force spectroscopy to measure non-specific protein-protein interactions, we found the dextran-coated beads nonreactive towards fibrinogen, thus providing an inert platform for biospecific modifications. Using periodate oxidation followed by reductive amination, we functionalized the bead-attached dextran with either cRGD or H12 and used the peptide-grafted beads to measure single-molecule interactions with the purified αIIbß3. Bimolecular force spectroscopy revealed that the peptide-functionalized beads were highly and specifically reactive with the immobilized αIIbß3. Further, the cRGD- and H12-functionalized beads displayed a remarkable interaction profile with a bimodal force distribution up to 90 pN. The cRGD-αIIbß3 interactions had greater binding strength than that of H12-αIIbß3, indicating that they are more stable and resistant mechanically, consistent with the platelet reactivity of RGD-containing ligands. Thus, the results reported here describe the mechanistic characteristics of αIIbß3-ligand interactions, confirming the utility of peptide-functionalized latex beads for the quantitative analysis of molecular recognition.


Assuntos
Plaquetas/metabolismo , Adesão Celular/fisiologia , Fibrinogênio/metabolismo , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/metabolismo , Sítios de Ligação , Plaquetas/citologia , Dextranos/farmacologia , Humanos , Pinças Ópticas , Peptídeos Cíclicos/sangue , Espectroscopia de Infravermelho com Transformada de Fourier
SELEÇÃO DE REFERÊNCIAS