Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 35(9): 2487-91, 2015 Sep.
Artigo em Chinês | MEDLINE | ID: mdl-26669153

RESUMO

Confocal three dimensional (3D) micro X-ray fluorescence (XRF) spectrometer based on a polycapillary focusing X-ray lens (PFXRL) in the excitation channel and a polycapillary parallel X-ray lens (PPXRL) in the detection channel was developed. The PFXRL and PPXRL were placed in a confocal configuration. This was helpful in improving the signal-to-noise ratio of the XRF spectra, and accordingly lowered the detection limitation of the XRF technology. The confocal configuration ensured that only the XRF signal from the confocal micro-volume overlapped by the output focal spot of the PFXRL and the input focal spot of the PPXRL could be detected by the detector. Therefore, the point-to-point information of XRF for samples could be obtained non-destructively by moving the sample located at the confocal position. The magnitude of the gain in power density of the PFXRL was 10(3). This let the low power conventional X-ray source be used in this confocal XRF, and, accordingly, decreased the requirement of high power X-ray source for the confocal XRF based on polycapillary X-ray optics. In this paper, we used the confocal 3D micro X-ray fluorescence spectrometer to non-destructively analyzed mineral samples and to carry out a 3D point-to-point elemental mapping scanning, which demonstrated the capabilities of confocal 3D micro XRF technology for non-destructive analysis elements composition and distribution for mineral samples. For one mineral sample, the experimental results showed that the area with high density of element of iron had high density of copper. To some extent, this reflected the growth mechanisms of the mineral sample. The confocal 3D micro XRF technology has potential applications in such fields like the analysis identification of ore, jade, lithoid utensils, "gamble stone" and lithoid flooring.

2.
Appl Opt ; 54(35): 10326-32, 2015 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-26836854

RESUMO

A combined shading system (CSS) consisting of a beam stop and a pinhole is proposed to be used between an ellipsoidal monocapillary (EM) and a conventional laboratory x-ray source to obtain an adjustable hollow-cone output beam for different experiments with no need for changing the EM. The CSS can change the incident x-ray beam on the EM by adjusting the position of the beam stop and the pinhole, with the corresponding change of the output beam of the EM. In this study, the adjustable hollow-cone output x-ray beam of an 80-mm-long EM with a CSS was studied in detail with a laboratory Cu x-ray generator with a focal spot diameter of 50 µm. The adjustable range of the focal spot size of the EM was from 8.6 to 58.7 µm. The adjustable range of the gain of the focal spot of the EM was from 0 to 1350. The beam divergence of the hollow-cone output beam of the EM ranged from 6 to 16.75 mrad. The illumination angle of the hollow-cone output beam of the EM ranged from 0 to 5.95 mrad. In addition, the potential application of the proposed adjusting method in testing the performance of the EM is briefly discussed.


Assuntos
Dispositivos Ópticos , Cristalografia por Raios X/instrumentação , Microanálise por Sonda Eletrônica/instrumentação , Microscopia Confocal/instrumentação , Fenômenos Ópticos , Espalhamento a Baixo Ângulo , Espectrometria por Raios X/instrumentação , Difração de Raios X/instrumentação , Raios X
3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(8): 2223-6, 2013 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-24159881

RESUMO

A confocal micro X-ray fluorescence thickness gauge based on a polycapillary focusing X-ray lens, a polycapillary parallel X-ray lens and a laboratory X-ray source was designed in order to analyze nondestructively the thickness of thin film and cladding material. The performances of this confocal thickness gauge were studied. Two Ni films with a thickness of about 25 and 15 microm respectively were measured. The relative errors corresponding to them were 3.5% and 7.1%, respectively. The thickness uniformity of a Ni films with a thickness of about 10 microm was analyzed. This confocal technology for measuring the thickness was both spatially resolved and elemental sensitive, and therefore, it could be used to measure the thickness of the multilayer sample and analyze the thickness uniformity of the sample. This confocal thickness gauge had potential applications in analyzing the thickness of sample.

4.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(11): 3147-50, 2013 Nov.
Artigo em Chinês | MEDLINE | ID: mdl-24555400

RESUMO

The confocal micro X-ray fluorescence (XRF) based on polycapillary X-ray lens and conventional X-ray source was used to carry out the scanning analysis of the distribution of the elements in a single hair. The elemental distribution in the single hair was obtained. In the confocal micro XRF technology, the output focal spot of the polycapillary focusing X-ray lens and the input focal spot of the polycapillary parallel X-ray lens were adjusted confocally. The detector could only detect the X-rays from the overlapping foci. This confocal structure decreased the effects of the background on the X-ray spectra, and was accordingly helpful for improving the accuracy of this XRF technology. A polycapillary focusing X-ray lens with a high gain in power density was used to decrease the requirement of power of the X-ray source used in this confocal technology, and made it possible to perform such confocal micro XRF analysis by using the conventional X-ray source with low cost. Experimental results indicated that the confocal micro X-ray fluorescence based on polycapillary X-ray lens had potential applications in analyzing the elemental distribution of individual hairs.


Assuntos
Cabelo/química , Espectrometria por Raios X , Oligoelementos/análise , Fluorescência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...