1.
J Environ Monit ; 1(4): 383-7, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11529141

RESUMO

Determinations of PCB were carried out as part of a project aimed at developing cleanup methods for PCB-containing elastic sealant used in outdoor joints between concrete blocks. The goals of the project were to develop methods, which minimise the spread of PCB to the outdoor environment and to indoor air, and which keep the PCB levels as low as reasonably possible in the workplace environment whilst removing the elastic sealant. The following PCB determinations were carried out: (1) concentration in the elastic sealant; (2) concentration in the concrete close to the sealant; (3) concentration in soil; (4) concentration in the indoor air; and (5) concentration in the air in the workplace environment. The cleanup process consisted of a number of different steps: (1) cutting the elastic sealant with an oscillating knife; (2) grinding the concrete with a mechanical machine; (3) sawing the concrete with a mechanical saw and (4) cutting the concrete with a mechanical chisel. In all these different steps a high capacity vacuum cleaner connected to the machines was used. The elastic sealant contained 4.7 to 8.1% total PCB of a technical product with a composition most similar to Clophene A40. The concrete close to the sealant (first 2 mm) contained 0.12 and 1.7% total PCB at two different places. The pattern of the PCB in the concrete resembled that of the sealant. PCB concentrations in the soil from the ground close to the building were 0.1 and 0.3 ppm at two different places before the remedial action. The source of the PCB in the soil is most likely the sealant as the PCB pattern is similar for the two materials. The PCB levels in the workplace air at the beginning of the project, when the techniques were not fully developed, were generally above the occupational exposure limit of 10 micrograms m-3 (up to 120 micrograms m-3). Later when the techniques were optimised to better take care of dust and gases produced during the cutting and grinding etc., the levels were below or close to 10 micrograms m-3. The pattern of the PCB in the workplace air was different from that of the sealant and contained higher levels of lighter components. The PCB concentrations in the indoor air were measured before and during the remedial process. The levels were around 600 ng m-3 and there was no significant increase during the removal of the sealant. The PCB level after the remedial action will be measured later. The pattern of the PCB in the indoor air was different from that of the sealant as well as from that of the workplace air. Higher levels of the lighter PCB were present indoors compared to the composition in both workplace air and in sealant. Extracts of PCB were analysed by GC-MS with a SIM method (selected ion monitoring). Standard procedures were used for extraction of solid materials. For the air samples an OVS tube was used with XAD-2 as adsorbent. The filter and adsorbent were extracted with toluene. This work shows that it is important to perform remedial action of PCB-containing elastic sealant as: (1) there is a spread of PCB to the indoor air giving high enough concentrations to make this the main PCB load on humans living in the apartments studied in this project; (2) large amounts are spread to the soil from these sealants; and (3) many of the PCB-containing elastic sealants used need to be changed from a functional perspective.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Exposição Ambiental , Poluentes Ambientais/análise , Bifenilos Policlorados/análise , Poluição do Ar em Ambientes Fechados/prevenção & controle , Habitação , Humanos , Manufaturas , Poluentes do Solo , Local de Trabalho
2.
Arch Biochem Biophys ; 351(2): 197-206, 1998 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-9514646

RESUMO

Four site-directed mutants of spinach plastocyanin, Pc(Leu12His), Pc(Leu15His), Pc(Thr79His), and Pc(Lys81His), have been modified by covalent attachment of a photoactive [Ru(bpy)2(im)]2+ complex at the surface-exposed histidine residues. The Pc-Ru complexes were characterized with optical absorption, CD, and EPR spectroscopy and their spectra were found to be similar to the unmodified proteins except in the case of the Pc(Leu12His) mutant which lost the Cu ion irreversibly during the Ru modification. Electron transfer (ET) within the other Pc-Ru complexes was studied with time-resolved optical spectroscopy, using an external-quencher approach. The fully reduced [Cu(I), Ru(II)] proteins were photoexcited and subsequently oxidized by an external quencher, [Ru(NH3)6]Cl3, forming the [Cu(I), Ru(III)] proteins. This was followed by an internal ET from Cu(I) to Ru(III). The rates of the internal ET reactions exhibit an exponential dependence on metal-to-metal separation, with a decay factor of 1.1 A-1. From a temperature-dependence study of the Ru-modified Pc(Lys81His) protein, a reorganization energy for the Cu-to-Ru ET reaction of 1.2 eV was determined. In this analysis it was found necessary to include an appreciable temperature dependence in the driving force of the ET reaction.


Assuntos
Transporte de Elétrons/fisiologia , Plastocianina/química , Compostos de Rutênio/farmacologia , Spinacia oleracea/fisiologia , Cobre/química , Cobre/metabolismo , Modelos Moleculares , Mutagênese Sítio-Dirigida/genética , Fotólise , Plastocianina/genética , Estrutura Terciária de Proteína , Compostos de Rutênio/metabolismo , Análise Espectral , Temperatura
3.
Biophys Chem ; 54(2): 191-7, 1995 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-7756569

RESUMO

The quenching of the triplet state of Zn-cytochrome c in electrostatic complexes with cytochrome oxidase and its soluble CuA domain has been studied by laser flash photolysis. The triplet state of free Zn-cytochrome c decayed with a rate of about 200 s-1. With the oxidase, biphasic decay with rate constants of 2 x 10(5) and 2 x 10(3) s-1, respectively, was observed. At high ionic strength (I = 0.2) the decay was the same as with free Zn-cytochrome c. The quenching was also eliminated by reduction of the oxidase. The decay rate in the complex with the CuA domain was 4 x 10(4) s-1. The results are interpreted in terms of rapid electron transfer to CuA and a slower one to cytochrome a. No electron transfer products were detected, because the backward reaction is faster than the forward one. This can be explained by the high driving force (1.1 eV) for the forward electron transfer, taking the system into the inverted Marcus region. The distance in the electrostatic complex between cytochrome c and the electron acceptor, presumed to be CuA, is calculated to be 16 A.


Assuntos
Cobre/química , Grupo dos Citocromos c/química , Citocromos c , Complexo IV da Cadeia de Transporte de Elétrons/química , Animais , Bovinos , Fenômenos Químicos , Físico-Química , Eletroquímica , Transporte de Elétrons , Cinética , Oxirredução , Fotólise , Espectrofotometria Ultravioleta
4.
J Chromatogr A ; 696(1): 139-48, 1995 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-7735462

RESUMO

Photophysical and photochemical properties of o-phthalaldehyde/beta-mercaptoethanol-labelled aliphatic alpha-peptides were investigated. It is found that alpha-peptide derivatives have lower fluorescence quantum yields, higher photodestruction quantum yields and lower yields for formation of solvated electrons as compared to amino acid and simple alkylamine derivatives in aqueous alkaline solution. These properties of the alpha-peptide derivatives sets narrow limits for their utilization in laser-based (high light intensity) detector systems. In contrast, the thermal stability of the peptide derivatives was found to be severalfold higher than for the parent amino acid derivatives. The differential rates of thermal derivative degradation could be utilized in a new approach towards selective determination of peptides. determination of peptides. determination of peptides.


Assuntos
Mercaptoetanol/química , Oligopeptídeos/química , o-Ftalaldeído/química , Fotoquímica , Espectrometria de Fluorescência , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...