Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
Int J Cardiol ; 399: 131684, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38151162

RESUMO

BACKGROUND: Coronary computed tomography angiography (CCTA)-based fractional flow reserve (CT-FFR) allows for noninvasive determination of the functional severity of anatomic lesions in patients with coronary artery disease. The aim of this study was to intra-individually compare CT-FFR between photon-counting detector (PCD) and conventional energy-integrating detector (EID) CT systems. METHODS: In this single-center prospective study, subjects who underwent clinically indicated CCTA on an EID-CT system were recruited for a research CCTA on PCD-CT within 30 days. Image reconstruction settings were matched as closely as possible between EID-CT (Bv36 kernel, iterative reconstruction strength level 3, slice thickness 0.5 mm) and PCD-CT (Bv36 kernel, quantum iterative reconstruction level 3, virtual monoenergetic level 55 keV, slice thickness 0.6 mm). CT-FFR was measured semi-automatically using a prototype on-site machine learning algorithm by two readers. CT-FFR analysis was performed per-patient and per-vessel, and a CT-FFR ≤ 0.75 was considered hemodynamically significant. RESULTS: A total of 22 patients (63.3 ± 9.2 years; 7 women) were included. Median time between EID-CT and PCD-CT was 5.5 days. Comparison of CT-FFR values showed no significant difference and strong agreement between EID-CT and PCD-CT in the per-vessel analysis (0.88 [0.74-0.94] vs. 0.87 [0.76-0.93], P = 0.096, mean bias 0.02, limits of agreement [LoA] -0.14/0.19, r = 0.83, ICC = 0.92), and in the per-patient analysis (0.81 [0.60-0.86] vs. 0.76 [0.64-0.86], P = 0.768, mean bias 0.02, LoA -0.15/0.19, r = 0.90, ICC = 0.93). All included patients were classified into the same category (CT-FFR > 0.75 vs ≤0.75) with both CT systems. CONCLUSIONS: CT-FFR evaluation is feasible with PCD-CT and it shows a strong agreement with EID-CT-based evaluation when images are similarly reconstructed.


Assuntos
Angiografia por Tomografia Computadorizada , Reserva Fracionada de Fluxo Miocárdico , Humanos , Feminino , Angiografia por Tomografia Computadorizada/métodos , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Angiografia Coronária/métodos , Imagens de Fantasmas
2.
Eur Radiol Exp ; 7(1): 59, 2023 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-37875769

RESUMO

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) may influence imaging characteristics for various clinical conditions due to higher signal and contrast-to-noise ratio in virtual monoenergetic images (VMI). Radiomics analysis relies on quantification of image characteristics. We evaluated the impact of different VMI reconstructions on radiomic features in in vitro and in vivo PCD-CT datasets. METHODS: An organic phantom consisting of twelve samples (four oranges, four onions, and four apples) was scanned five times. Twenty-three patients who had undergone coronary computed tomography angiography on a first generation PCD-CT system with the same image acquisitions were analyzed. VMIs were reconstructed at 6 keV levels (40, 55, 70, 90, 120, and 190 keV). The phantoms and the patients' left ventricular myocardium (LVM) were segmented for all reconstructions. Ninety-three original radiomic features were extracted. Repeatability and reproducibility were evaluated through intraclass correlations coefficient (ICC) and post hoc paired samples ANOVA t test. RESULTS: There was excellent repeatability for radiomic features in phantom scans (all ICC = 1.00). Among all VMIs, 36/93 radiomic features (38.7%) in apples, 28/93 (30.1%) in oranges, and 33/93 (35.5%) in onions were not significantly different. For LVM, the percentage of stable features was high between VMIs ≥ 90 keV (90 versus 120 keV, 77.4%; 90 versus 190 keV, 83.9%; 120 versus 190 keV, 89.3%), while comparison to lower VMI levels led to fewer reproducible features (40 versus 55 keV, 8.6%). CONCLUSIONS: VMI levels influence the stability of radiomic features in an organic phantom and patients' LVM; stability decreases considerably below 90 keV. RELEVANCE STATEMENT: Spectral reconstructions significantly influence radiomic features in vitro and in vivo, necessitating standardization and careful attention to these reconstruction parameters before clinical implementation. KEY POINTS: • Radiomic features have an excellent repeatability within the same PCD-CT acquisition and reconstruction. • Differences in VMI lead to decreased reproducibility for radiomic features. • VMI ≥ 90 keV increased the reproducibility of the radiomic features.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Miocárdio
3.
Eur J Radiol ; 166: 111008, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37542817

RESUMO

PURPOSE: To intra-individually compare the objective and subjective image quality of coronary computed tomography angiography (CCTA) between photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT). METHOD: Consecutive patients undergoing clinically indicated CCTA on an EID-CT system were prospectively enrolled for a research CCTA performed on a PCD-CT system within 30 days. Polychromatic images were reconstructed for both EID- and PCD-CT, while virtual monoenergetic images (VMI) were generated at 40, 45, 50, 55, 60 and 70 keV for PCD-CT. Two blinded readers calculated contrast-to-noise ratio (CNR) for each major coronary artery and rated image noise, vessel attenuation, vessel sharpness, and overall quality on a 1-5 Likert scale. Patients were then stratified by body mass index (BMI) [high (>30 kg/m2) vs low (<30 kg/m2)] for subgroup analysis. RESULTS: A total of 20 patients (67.5 ± 9.0 years, 75% male) were included in the study. Compared with EID-CT, coronary artery CNR values from PCD-CT monoenergetic and polychromatic reconstructions were all significantly higher than CNR values from EID-CT, with incrementally greater differences in obese subjects (all p < 0.008). Subjective image noise and sharpness were also significantly higher for all VMI reconstructions compared to EID-CT (all p < 0.008). All subjective scores were significantly higher for 55, 60, and 70 keV PCD-CT than EID-CT values (all p < 0.05). CONCLUSIONS: The improved objective and subjective image quality of PCD-CT compared to EID-CT may provide better visualization of the coronary arteries for a wide array of patients, especially those with a high BMI.


Assuntos
Vasos Coronários , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos , Coração , Fótons , Imagens de Fantasmas
4.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1684-1693, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37354175

RESUMO

BACKGROUND: The PAINESD (Pulmonary disease, Age, Ischemic cardiomyopathy, NYHA functional class, Ejection fraction, Storm, Diabetes mellitus) risk score has been validated as a predictor of periprocedural acute hemodynamic decompensation (AHD) in patients undergoing ventricular tachycardia (VT) ablation. Whether the addition of total scar volume (TSV) determined by preprocedure computed tomography imaging provides additional risk stratification has not been previously investigated. OBJECTIVES: The purpose of this study was to evaluate the impact of TSV on the risk of AHD and its adjunctive benefit to the PAINESD score newly modified as Pulmonary disease, Age, Ischemic cardiomyopathy, NYHA class, Ejection fraction, Storm, Scar volume, Diabetes mellitus (PAINES2D) based on the addition of scar volumes. METHODS: This was a retrospective analysis of all index VT ablations at a quaternary care center from 2017 to 2022. Associations between TSV and AHD were evaluated among patients with structural heart disease. RESULTS: Among 61 patients with TSV data, 13 (21%) had periprocedural AHD. TSV and PAINESD were independently associated with AHD risk. Both TSV and PAINESD were associated with AHD (P = 0.016 vs P = 0.053, respectively). The highest TSV tertile (≥37.30 mL) showed significant association with AHD (P = 0.018; OR: 4.80) compared to the other tertiles. The PAINESD and PAINES2D scores had significant impact on AHD (P = 0.046 and P = 0.010, respectively). The PAINES2D score had a greater impact on AHD compared to PAINESD (area under the curve: 0.73; P = 0.011; 95% CI: 0.56-0.91 and area under the curve: 0.67; P = 0.058; 95% CI: 0.49-0.85, respectively). CONCLUSIONS: Addition of TSV to a modified PAINESD score, PAINES2D, enhances risk prediction of AHD. Further prospective study is needed to assess benefit in various cardiomyopathy populations undergoing VT ablation.


Assuntos
Ablação por Cateter , Hemodinâmica , Taquicardia Ventricular , Humanos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cicatriz/complicações , Cicatriz/diagnóstico por imagem , Hemodinâmica/fisiologia , Estudos Retrospectivos , Medição de Risco , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Masculino , Feminino , Idoso , Tomografia Computadorizada por Raios X
5.
Invest Radiol ; 58(9): 673-680, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36822677

RESUMO

OBJECTIVES: The aim of this study was to evaluate the impact of virtual monoenergetic imaging (VMI) and quantum iterative reconstruction (QIR) on the accuracy of coronary artery calcium scoring (CACS) using a virtual noniodine (VNI) reconstruction algorithm on a first-generation, clinical, photon counting detector computed tomography system. MATERIALS AND METHODS: Coronary artery calcium scoring was evaluated in an anthropomorphic chest phantom simulating 3 different patient sizes by using 2 extension rings (small: 300 × 200 mm, medium: 350 × 250 mm, large: 400 × 300 mm) and in patients (n = 61; final analyses only in patients with coronary calcifications [n = 34; 65.4 ± 10.0 years; 73.5% male]), who underwent nonenhanced and contrast-enhanced, electrocardiogram-gated, cardiac computed tomography on a photon counting detector system. Phantom and patient data were reconstructed using a VNI reconstruction algorithm at different VMI (55-80 keV) and QIR (strength 1-4) levels (CACS VNI ). True noncontrast (TNC) scans at 70 keV and QIR "off" were used as reference for phantom and patient studies (CACS TNC ). RESULTS: In vitro and in vivo CACS VNI showed strong correlation ( r > 0.9, P < 0.001 for all) and excellent agreement (intraclass correlation coefficient > 0.9 for all) with CACS TNC at all investigated VMI and QIR levels. Phantom and patient CACS VNI significantly increased with decreasing keV levels (in vitro: from 475.2 ± 26.3 at 80 keV up to 652.5 ± 42.2 at 55 keV; in vivo: from 142.5 [7.4/737.7] at 80 keV up to 248.1 [31.2/1144] at 55 keV; P < 0.001 for all), resulting in an overestimation of CACS VNI at 55 keV compared with CACS TNC at 70 keV in some cases (in vitro: 625.8 ± 24.4; in vivo: 225.4 [35.1/959.7]). In vitro CACS increased with rising QIR at low keV. In vivo scores were significantly higher at QIR 1 compared with QIR 4 only at 60 and 80 keV (60 keV: 220.3 [29.6-1060] vs 219.5 [23.7/1048]; 80 keV: 152.0 [12.0/735.6] vs 142.5 [7.4/737.7]; P < 0.001). CACS VNI was closest to CACS TNC at 60 keV, QIR 2 (+0.1%) in the small; 55 keV, QIR 1 (±0%) in the medium; 55 keV, QIR 4 (-0.1%) in the large phantom; and at 60 keV, QIR 1 (-2.3%) in patients. CONCLUSIONS: Virtual monoenergetic imaging reconstructions have a significant impact on CACS VNI . The effects of different QIR levels are less consistent and seem to depend on several individual conditions, which should be further investigated.


Assuntos
Cálcio , Vasos Coronários , Humanos , Masculino , Feminino , Razão Sinal-Ruído , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Algoritmos
6.
Radiology ; 307(2): e222030, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36719292

RESUMO

Background Photon-counting detector (PCD) CT provides comprehensive spectral data with every acquisition, but studies evaluating myocardial extracellular volume (ECV) quantification with use of PCD CT compared with an MRI reference remain lacking. Purpose To compare ECV quantification for myocardial tissue characterization between a first-generation PCD CT system and cardiac MRI. Materials and Methods In this single-center prospective study, adults without contraindication to iodine-based contrast media underwent same-day cardiac PCD CT and MRI with native and postcontrast T1 mapping and late gadolinium enhancement for various clinical indications for cardiac MRI (the reference standard) between July 2021 and January 2022. Global and midventricular ECV were assessed with use of three methods: single-energy PCD CT, dual-energy PCD CT, and MRI T1 mapping. Quantitative comparisons among all techniques were performed. Correlation and reliability between different methods of ECV quantification were assessed with use of the Pearson correlation coefficient (r) and the intraclass correlation coefficient. Results The final sample included 29 study participants (mean age ± SD, 54 years ± 17; 15 men). There was a strong correlation of ECV between dual- and single-energy PCD CT (r = 0.91, P < .001). Radiation dose was 40% lower with dual-energy versus single-energy PCD CT (volume CT dose index, 10.1 mGy vs 16.8 mGy, respectively; P < .001). In comparison with MRI, dual-energy PCD CT showed strong correlation (r = 0.82 and 0.91, both P < .001) and good to excellent reliability (intraclass correlation coefficients, 0.81 and 0.90) for midventricular and global ECV quantification, but it overestimated ECV by approximately 2%. Single-energy PCD CT showed similar relationship with MRI but underestimated ECV by 3%. Conclusion Myocardial tissue characterization with photon-counting detector CT-based quantitative extracellular volume analysis showed a strong correlation to MRI. © RSNA, 2023 Supplemental material is available for this article.


Assuntos
Meios de Contraste , Gadolínio , Masculino , Adulto , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos
7.
Invest Radiol ; 58(2): 148-155, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36165932

RESUMO

PURPOSE: The aim of this study was to evaluate strategies to reduce contrast media volumes for coronary computed tomography (CT) angiography on a clinical first-generation dual-source photon-counting detector (PCD)-CT system using a dynamic circulation phantom. MATERIALS AND METHODS: Coronary CT angiograph is an established method for the assessment of coronary artery disease that relies on the administration of iodinated contrast media. Reduction of contrast media volumes while maintaining diagnostic image quality is desirable. In this study, a dynamic phantom containing a 3-dimensional-printed model of the thoracic aorta and coronary arteries was evaluated using a clinical contrast injection protocol with stepwise reduced contrast agent concentrations (100%, 75%, 50%, 40%, 30%, and 20% contrast media content of the same 50 mL bolus, resulting in iodine delivery rates of 1.5, 1.1, 0.7, 0.6, 0.4 and 0.3 gl/s) on a first-generation, dual-source PCD-CT. Polychromatic images (T3D) and virtual monoenergetic images were reconstructed in the range of 40 to 70 keV in 5-keV steps. Attenuation and noise were measured in the coronary arteries and background material and the contrast-to-noise ratio (CNR) were calculated. Attenuation of 350 HU and a CNR of the reference protocol at 70 keV were regarded as sufficient for simulation of diagnostic purposes. Vessel sharpness and noise power spectra were analyzed for the aforementioned reconstructions. RESULTS: The standard clinical contrast protocol (bolus with 100% contrast) yielded diagnostic coronary artery attenuation for all tested reconstructions (>398 HU). A 50% reduction in contrast media concentration demonstrated sufficient attenuation of the coronary arteries at 40 to 55 keV (>366 HU). Virtual monoenergetic image reconstructions of 40 to 45 and 40 keV allowed satisfactory attenuation of the coronary arteries for contrast concentrations of 40% and 30% of the original protocol. A reduction of contrast agent concentration to 20% of the initial concentration provided insufficient attenuation in the target vessels for all reconstructions. The highest CNR was found for virtual monoenergetic reconstructions at 40 keV for all contrast media injection protocols, yielding a sufficient CNR at a 50% reduction of contrast agent concentration. CONCLUSIONS: Using virtual monoenergetic image reconstructions at 40 keV on a dual-source PCD-CT system, contrast media concentration could be reduced by 50% to obtain diagnostic attenuation and objective image quality for coronary CT angiography in a dynamic vessel phantom. These initial feasibility study results have to be validated in clinical studies.


Assuntos
Meios de Contraste , Iodo , Angiografia por Tomografia Computadorizada/métodos , Tomografia Computadorizada por Raios X/métodos , Angiografia/métodos , Razão Sinal-Ruído , Estudos Retrospectivos
8.
Top Magn Reson Imaging ; 31(1): 3-8, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35225839

RESUMO

ABSTRACT: We present a patient with history of systemic lupus erythematosus who presented with acute chest pain. Electrocardiography, invasive coronary angiography, and cardiac MRI were performed during the course of her evaluation. Invasive coronary angiography demonstrated obstructive disease in the diagonal system and cardiovascular MRI confirmed an anterior infarct consistent with the electrocardiographic findings. However, MRI also revealed focal inferoseptal hypoperfusion inconsistent with electrocardiographic and angiographic findings. Rather, these findings indicate the presence of concurrent microvascular coronary artery disease, which has a high prevalence among women with autoimmune disease.


Assuntos
Doença da Artéria Coronariana , Lúpus Eritematoso Sistêmico , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Eletrocardiografia , Feminino , Humanos , Lúpus Eritematoso Sistêmico/complicações , Lúpus Eritematoso Sistêmico/diagnóstico por imagem , Imageamento por Ressonância Magnética
9.
Front Cardiovasc Med ; 9: 1053398, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36741832

RESUMO

Purpose: To compare coronary artery calcium volume and score (CACS) between photon-counting detector (PCD) and conventional energy integrating detector (EID) computed tomography (CT) in a phantom and prospective patient study. Methods: A commercially available CACS phantom was scanned with a standard CACS protocol (120 kVp, slice thickness/increment 3/1.5 mm, and a quantitative Qr36 kernel), with filtered back projection on the EID-CT, and with monoenergetic reconstruction at 70 keV and quantum iterative reconstruction off on the PCD-CT. The same settings were used to prospectively acquire data in patients (n = 23, 65 ± 12.1 years), who underwent PCD- and EID-CT scans with a median of 5.5 (3.0-12.5) days between the two scans in the period from August 2021 to March 2022. CACS was quantified using a commercially available software solution. A regression formula was obtained from the aforementioned comparison and applied to simulate risk reclassification in a pre-existing cohort of 514 patients who underwent a cardiac EID-CT between January and December 2021. Results: Based on the phantom experiment, CACS PCD-CT showed a more accurate measurement of the reference CAC volumes (overestimation of physical volumes: PCD-CT 66.1 ± 1.6% vs. EID-CT: 77.2 ± 0.5%). CACS EID-CT and CACS PCD-CT were strongly correlated, however, the latter measured significantly lower values in the phantom (CACS PCD-CT : 60.5 (30.2-170.3) vs CACS EID-CT 74.7 (34.6-180.8), p = 0.0015, r = 0.99, mean bias -9.7, Limits of Agreement (LoA) -36.6/17.3) and in patients (non-significant) (CACS PCD-CT : 174.3 (11.1-872.7) vs CACS EID-CT 218.2 (18.5-876.4), p = 0.10, r = 0.94, mean bias -41.1, LoA -315.3/232.5). The systematic lower measurements of Agatston score on PCD-CT system led to reclassification of 5.25% of our simulated patient cohort to a lower classification class. Conclusion: CACS PCD-CT is feasible and correlates strongly with CACS EID-CT , however, leads to lower CACS values. PCD-CT may provide results that are more accurate for CACS than EID-CT.

10.
J Am Coll Radiol ; 18(11S): S380-S393, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34794595

RESUMO

Noncerebral vasculitis is a wide-range noninfectious inflammatory disorder affecting the vessels. Vasculitides have been categorized based on the vessel size, such as large-vessel vasculitis, medium-vessel vasculitis, and small-vessel vasculitis. In this document, we cover large-vessel vasculitis and medium-vessel vasculitis. Due to the challenges of vessel biopsy, imaging plays a crucial role in diagnosing this entity. While CTA and MRA can both provide anatomical details of the vessel wall, including wall thickness and enhancement in large-vessel vasculitis, FDG-PET/CT can show functional assessment based on the glycolytic activity of inflammatory cells in the inflamed vessels. Given the size of the vessel in medium-vessel vasculitis, invasive arteriography is still a choice for imaging. However, high-resolution CTA images can depict small-caliber aneurysms, and thus can be utilized in the diagnosis of medium-vessel vasculitis. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Vasculite , Diagnóstico por Imagem , Humanos , Sociedades Médicas , Estados Unidos
11.
J Am Coll Radiol ; 18(11S): S482-S487, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34794602

RESUMO

The initial diagnosis of retroperitoneal bleeding can be challenging by physical examination and clinical presentation. Prompt imaging can make the diagnosis and be lifesaving. When selecting appropriate imaging for these patient's, consideration must be made for sensitivity and ability to image the retroperitoneum, as well as speed of imaging.The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Assuntos
Medicina Baseada em Evidências , Sociedades Médicas , Diagnóstico Diferencial , Diagnóstico por Imagem , Humanos , Estados Unidos
12.
J Am Coll Radiol ; 18(5S): S139-S152, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33958109

RESUMO

Diverticulosis remains the commonest cause for acute lower gastrointestinal tract bleeding (GIB). Conservative management is initially sufficient for most patients, followed by elective diagnostic tests. However, if acute lower GIB persists, it can be investigated with colonoscopy, CT angiography (CTA), or red blood cell (RBC) scan. Colonoscopy can identify the site and cause of bleeding and provide effective treatment. CTA is a noninvasive diagnostic tool that is better tolerated by patients, can identify actively bleeding site or a potential bleeding lesion in vast majority of patients. RBC scan can identify intermittent bleeding, and with single-photon emission computed tomography, can more accurately localize it to a small segment of bowel. If patients are hemodynamically unstable, CTA and transcatheter arteriography/embolization can be performed. Colonoscopy can also be considered in these patients if rapid bowel preparation is feasible. Transcatheter arteriography has a low rate of major complications; however, targeted transcatheter embolization is only feasible if extravasation is seen, which is more likely in hemodynamically unstable patients. If bleeding site has been previously localized but the intervention by colonoscopy and transcatheter embolization have failed to achieve hemostasis, surgery may be required. Among patients with obscure (nonlocalized) recurrent bleeding, capsule endoscopy and CT enterography can be considered to identify culprit mucosal lesion(s). The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Assuntos
Radiologia , Sociedades Médicas , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/terapia , Humanos , Trato Gastrointestinal Inferior/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Estados Unidos
13.
Eur Radiol Exp ; 5(1): 13, 2021 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-33763736

RESUMO

The widespread clinical use of cardiovascular imaging inspires constant improvement in imaging technology and post-processing applications. Recent advances in hardware and software have brought about important developments in the assessment of myocardial ischemia such as the rapid evaluation of cardiac volumes and function, ability for detection of subtle myocardial changes, and the combination of anatomic and functional assessment of a coronary artery stenosis via a single modality, which was previously not possible in a noninvasive fashion. These milestones indicate the start of a new era, a paradigm shift that broadens the role of noninvasive imaging. The thematic series Myocardial tissue characterization in ischemic heart disease introduces a set of narrative review and original articles by world renowned authors demonstrating such novel advancements and the state-of-the-art techniques in cardiac imaging.


Assuntos
Isquemia Miocárdica , Técnicas de Imagem Cardíaca , Diagnóstico por Imagem , Humanos , Isquemia Miocárdica/diagnóstico por imagem
14.
J Cardiovasc Magn Reson ; 23(1): 7, 2021 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-33557887

RESUMO

BACKGROUND: Patients with thoracic aortic dilatation who undergo annual computed tomography angiography (CTA) are subject to repeated radiation and contrast exposure. The purpose of this study was to evaluate the feasibility of a non-contrast, respiratory motion-resolved whole-heart cardiovascular magnetic resonance angiography (CMRA) technique against reference standard CTA, for the quantitative assessment of cardiovascular anatomy and monitoring of disease progression in patients with thoracic aortic dilatation.  METHODS: Twenty-four patients (68.6 ± 9.8 years) with thoracic aortic dilatation prospectively underwent clinical CTA and research 1.5T CMRA between July 2017 and November 2018. Scans were repeated in 15 patients 1 year later. A prototype free-breathing 3D radial balanced steady-state free-precession whole-heart CMRA sequence was used in combination with compressed sensing-based reconstruction. Area, circumference, and diameter measurements were obtained at seven aortic levels by two experienced and two inexperienced readers. In addition, area and diameter measurements of the cardiac chambers, pulmonary arteries and pulmonary veins were also obtained. Agreement between the two modalities was assessed with intraclass correlation coefficient (ICC) analysis, Bland-Altman plots and scatter plots. RESULTS: Area, circumference and diameter measurements on a per-level analysis showed good or excellent agreement between CTA and CMRA (ICCs > 0.84). Means of differences on Bland-Altman plots were: area 0.0 cm2 [- 1.7; 1.6]; circumference 1.0 mm [- 10.0; 12.0], and diameter 0.6 mm [- 2.6; 3.6]. Area and diameter measurements of the left cardiac chambers showed good agreement (ICCs > 0.80), while moderate to good agreement was observed for the right chambers (all ICCs > 0.56). Similar good to excellent inter-modality agreement was shown for the pulmonary arteries and veins (ICC range 0.79-0.93), with the exception of the left lower pulmonary vein (ICC < 0.51). Inter-reader assessment demonstrated mostly good or excellent agreement for both CTA and CMRA measurements on a per-level analysis (ICCs > 0.64). Difference in maximum aortic diameter measurements at baseline vs follow up showed excellent agreement between CMRA and CTA (ICC = 0.91). CONCLUSIONS: The radial whole-heart CMRA technique combined with respiratory motion-resolved reconstruction provides comparable anatomical measurements of the thoracic aorta and cardiac structures as the reference standard CTA. It could potentially be used to diagnose and monitor patients with thoracic aortic dilatation without exposing them to radiation or contrast media.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aortografia , Angiografia por Tomografia Computadorizada , Coração/diagnóstico por imagem , Angiografia por Ressonância Magnética , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/patologia , Aneurisma da Aorta Torácica/patologia , Dilatação Patológica , Progressão da Doença , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo
15.
J Thorac Imaging ; 36(6): 345-352, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-32205821

RESUMO

OBJECTIVES: Computed tomography (CT) myocardial perfusion imaging (CT-MPI) with hyperemia induced by regadenoson was evaluated for the detection of myocardial ischemia, safety, relative radiation exposure, and patient experience compared with single-photon emission computed tomography (SPECT) imaging. MATERIALS AND METHODS: Twenty-four patients (66.5 y, 29% male) who had undergone clinically indicated SPECT imaging and provided written informed consent were included in this phase II, IRB-approved, and FDA-approved clinical trial. All patients underwent coronary CT angiography and CT-MPI with hyperemia induced by the intravenous administration of regadenoson (0.4 mg/5 mL). Patient experience and findings on CT-MPI images were compared to SPECT imaging. RESULTS: Patient experience and safety were similar between CT-MPI and SPECT procedures and no serious adverse events due to the administration of regadenoson occurred. SPECT resulted in a higher number of mild adverse events than CT-MPI. Patient radiation exposure was similar during the combined coronary computed tomography angiography and CT-MPI (4.4 [2.7] mSv) and SPECT imaging (5.6 [1.7] mSv) (P-value 0.401) procedures. Using SPECT as the reference standard, CT-MPI analysis showed a sensitivity of 58.3% (95% confidence interval [CI]: 27.7-84.8), a specificity of 100% (95% CI: 73.5-100), and an accuracy of 79.1% (95% CI: 57.9-92.87). Low apparent sensitivity occurred when the SPECT defects were small and highly suspicious for artifacts. CONCLUSIONS: This study demonstrated that CT-MPI is safe, well tolerated, and can be performed with comparable radiation exposure to SPECT. CT-MPI has the benefit of providing both complete anatomic coronary evaluation and assessment of myocardial perfusion.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Angiografia Coronária , Estudos de Viabilidade , Feminino , Humanos , Masculino , Purinas , Pirazóis , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
16.
Eur Radiol ; 31(5): 2778-2787, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33068186

RESUMO

OBJECTIVES: The proton density-weighted, in-phase stack-of-stars (PDIP-SOS) MRI technique provides calcification visualization in peripheral artery disease (PAD). This study sought to investigate the diagnostic accuracy of a combined non-contrast quiescent-interval slice-selective (QISS) MRA and PDIP-SOS MRI protocol for the detection of PAD, in comparison with CTA and digital subtraction angiography (DSA). METHODS: Twenty-six prospectively enrolled PAD patients (70 ± 8 years) underwent lower extremity CTA and 1.5-T or 3-T PDIP-SOS/QISS MRI prior to DSA. Two readers rated image quality and graded stenosis (≥ 50%) on QISS MRA without/with calcification visualization. Sensitivity, specificity, and area under the curve (AUC) were calculated against DSA. Calcification was quantified and compared between MRI and non-contrast CT (NCCT) using paired t test, Pearson's correlation, and Bland-Altman analysis. RESULTS: Image quality ratings were significantly higher for CTA compared to those for MRA (4.0 [3.0-4.0] and 3.0 [3.0-4.0]; p = 0.0369). The sensitivity and specificity of QISS MRA, QISS MRA with PDIP-SOS, and CTA for ≥ 50% stenosis detection were 85.4%, 92.2%, and 90.2%, and 90.3%, 93.2%, and 94.2%, respectively, while AUCs were 0.879, 0.928, and 0.923, respectively. A significant increase in AUC was observed when PDIP-SOS was added to the MRA protocol (p = 0.0266). Quantification of calcification showed significant differences between PDIP-SOS and NCCT (80.6 ± 31.2 mm3 vs. 88.0 ± 29.8 mm3; p = 0.0002) with high correlation (r = 0.77, p < 0.0001) and moderate mean of differences (- 7.4 mm3). CONCLUSION: QISS MRA combined with PDIP-SOS MRI provides improved, CTA equivalent, accuracy for the detection of PAD, although its image quality remains inferior to CTA. KEY POINTS: • Agreement in stenosis detection rate using non-contrast quiescent-interval slice-selective MRA compared to DSA improved when calcification visualization was provided to the readers. • An increase was observed in both sensitivity and specificity for the detection of ≥ 50% stenosis when MRI-based calcification assessment was added to the protocol, resulting in a diagnostic accuracy more comparable to CTA. • Quantification of calcification showed statistical difference between MRI and non-contrast CT; however, a high correlation was observed between the techniques.


Assuntos
Doença Arterial Periférica , Calcificação Vascular , Angiografia Digital , Constrição Patológica/diagnóstico por imagem , Meios de Contraste , Humanos , Extremidade Inferior/diagnóstico por imagem , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Doença Arterial Periférica/complicações , Doença Arterial Periférica/diagnóstico por imagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Calcificação Vascular/complicações , Calcificação Vascular/diagnóstico por imagem
17.
J Am Coll Radiol ; 17(5S): S315-S322, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32370975

RESUMO

This publication includes the appropriate imaging modalities to assess suspected deep vein thrombosis in the upper extremities. Ultrasound duplex Doppler is the most appropriate imaging modality to assess upper-extremity deep vein thrombosis. It is a noninvasive test, which can be performed at the bedside and used for serial evaluations. Ultrasound can also directly identify thrombus by visualizing echogenic material in the vein and by lack of compression of the vein walls from manual external pressure. It can indirectly identify thrombus from altered blood-flow patterns. It is most appropriate in the evaluation of veins peripheral to the brachiocephalic vein. CT venography and MR venography are not first-line imaging tests, but are appropriate to assess the central venous structures, or to assess the full range of venous structures from the hand to the right atrium. Catheter venography is appropriate if therapy is required. Radionuclide venography and chest radiography are usually not appropriate to assess upper-extremity deep vein thrombosis. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Assuntos
Trombose Venosa Profunda de Membros Superiores , Angiografia por Tomografia Computadorizada , Diagnóstico por Imagem , Humanos , Sociedades Médicas , Estados Unidos , Extremidade Superior/diagnóstico por imagem , Trombose Venosa Profunda de Membros Superiores/diagnóstico por imagem
18.
J Thorac Imaging ; 35(3): 198-203, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32032251

RESUMO

PURPOSE: The purpose of this study was to evaluate the utilization of invasive and noninvasive tests and compare cost in patients presenting with chest pain to the emergency department (ED) who underwent either triple-rule-out computed tomography angiography (TRO-CTA) or standard of care. MATERIALS AND METHODS: We performed a retrospective single-center analysis of 2156 ED patients who presented with acute chest pain with a negative initial troponin and electrocardiogram for myocardial injury. Patient cohorts matched by patient characteristics who had undergone TRO-CTA as a primary imaging test (n=1139) or standard of care without initial CTA imaging (n=1017) were included in the study. ED visits, utilization of tests, and costs during the initial episode of hospital care were compared. RESULTS: No significant differences in the diagnosis of coronary artery disease, pulmonary embolism, or aortic dissection were observed. Median ED waiting time (4.5 vs. 7.0 h, P<0.001), median total length of hospital stay (5.0 vs. 32.0 h, P<0.001), hospital admission rate (12.6% vs. 54.2%, P<0.001), and ED return rate to our hospital within 30 days (3.5% vs. 14.6%, P<0.001) were significantly lower in the TRO-CTA group. Moreover, reduced rates of additional testing and invasive coronary angiography (4.9% vs. 22.7%, P<0.001), and ultimately lower total cost per patient (11,783$ vs. 19,073$, P<0.001) were observed in the TRO-CTA group. CONCLUSIONS: TRO-CTA as an initial imaging test in ED patients presenting with acute chest pain was associated with shorter ED and hospital length of stay, fewer return visits within 30 days, and ultimately lower ED and hospitalization costs.


Assuntos
Dor no Peito/economia , Angiografia por Tomografia Computadorizada/economia , Angiografia Coronária/economia , Doença da Artéria Coronariana/complicações , Custos e Análise de Custo/métodos , Padrão de Cuidado/economia , Dor Aguda/líquido cefalorraquidiano , Dor Aguda/diagnóstico por imagem , Dor Aguda/economia , Dor Aguda/etiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Dor no Peito/diagnóstico por imagem , Dor no Peito/etiologia , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Angiografia Coronária/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/economia , Custos e Análise de Custo/economia , Custos e Análise de Custo/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Padrão de Cuidado/estatística & dados numéricos , Adulto Jovem
19.
Eur Radiol Exp ; 3(1): 29, 2019 07 31.
Artigo em Inglês | MEDLINE | ID: mdl-31363865

RESUMO

BACKGROUND: Whole-heart magnetic resonance angiography (MRA) requires sophisticated methods accounting for respiratory motion. Our purpose was to evaluate the image quality of compressed sensing-based respiratory motion-resolved three-dimensional (3D) whole-heart MRA compared with self-navigated motion-corrected whole-heart MRA in patients with known thoracic aorta dilation. METHODS: Twenty-five patients were prospectively enrolled in this ethically approved study. Whole-heart 1.5-T MRA was acquired using a prototype 3D radial steady-state free-precession free-breathing sequence. The same data were reconstructed with a one-dimensional motion-correction algorithm (1D-MCA) and an extradimensional golden-angle radial sparse parallel reconstruction (XD-GRASP). Subjective image quality was scored and objective image quality was quantified (signal intensity ratio, SIR; vessel sharpness). Wilcoxon, McNemar, and paired t tests were used. RESULTS: Subjective image quality was significantly higher using XD-GRASP compared to 1D-MCA (median 4.5, interquartile range 4.5-5.0 versus 4.0 [2.25-4.75]; p < 0.001), as well as signal homogeneity (3.0 [3.0-3.0] versus 2.0 [2.0-3.0]; p = 0.003), and image sharpness (3.0 [2.0-3.0] vs 2.0 [1.25-3.0]; p < 0.001). SIR with the 1D-MCA and XD-GRASP was 6.1 ± 3.9 versus 7.4 ± 2.5, respectively (p < 0.001); while signal homogeneity was 274.2 ± 265.0 versus 199.8 ± 67.2 (p = 0.129). XD-GRASP provided a higher vessel sharpness (45.3 ± 10.7 versus 40.6 ± 101, p = 0.025). CONCLUSIONS: XD-GRASP-based motion-resolved reconstruction of free-breathing 3D whole-heart MRA datasets provides improved image contrast, sharpness, and signal homogeneity and seems to be a promising technique that overcomes some of the limitations of motion correction or respiratory navigator gating.


Assuntos
Aorta Torácica , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/fisiopatologia , Coração/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Respiração , Idoso , Doenças da Aorta/patologia , Dilatação Patológica , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Movimento , Estudos Prospectivos
20.
Am J Med Sci ; 358(4): 299-303, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31353027

RESUMO

Apical hypertrophic cardiomyopathy is a variant of hypertrophic cardiomyopathy characterized by apical hypertrophy, deep T-wave inversions in precordial electrocardiogram (EKG) leads, and a ventriculogram shaped like the "Ace of Spades." Patients are often asymptomatic but sometimes present with atypical chest pain, angina, or atrial fibrillation. The deep T-wave inversions on EKG often mimic acute coronary syndrome. Coronary angiogram in these patients is unrevealing, but the characteristic left ventriculogram establishes this diagnosis. The deep T-wave inversions can appear suddenly or deepen over years, making the diagnosis difficult to establish early in the disease. Transthoracic echocardiogram may miss the hypertrophied apex, but echo contrast imaging or cardiac magnetic resonance imaging can reliably confirm the diagnosis and detect apical aneurysms. We present a case of apical hypertrophic cardiomyopathy which was not evident despite many admissions, EKGs, cardiac catheterizations and echocardiograms until the diagnosis was confirmed with left ventriculogram and cardiac magnetic resonance imaging 20 years after initial presentation.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico , Dor no Peito/diagnóstico , Idoso , Cateterismo Cardíaco , Cardiomiopatia Hipertrófica/fisiopatologia , Dor no Peito/fisiopatologia , Angiografia Coronária , Eletrocardiografia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Diagnóstico Ausente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...