1.
Med Phys ; 47(8): 3389-3401, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32304583

RESUMO

PURPOSE: Near-infrared fluorescence (NIRF) imaging using exogenous contrast has gained much attention as a technique for enhancing visualization of vasculature using untargeted agents, as well as for the detection and localization of cancer with targeted agents. In order to address the emerging need for standardization of NIRF imaging technologies, it is necessary to identify the best practices suitable for objective, quantitative testing of key image quality characteristics. Toward the development of a battery of test methods that are rigorous yet applicable to a wide variety of devices, we have evaluated techniques for phantom design, measurement, and calculation of specific performance metrics. METHODS: Using a NIRF imaging system for indocyanine green imaging, providing excitation at 780 nm and detection above 830 nm, we explored methods to evaluate uniformity, field of view, spectral crosstalk, spatial resolution, depth of field, sensitivity, linearity, and penetration depth. These measurements were performed using fluorophore-doped multiwell plate and high turbidity planar phantoms, as well as a 3D-printed multichannel phantom and a USAF 1951 resolution target. RESULTS AND CONCLUSIONS: Based on a wide range of approaches described in medical and fluorescence imaging literature, we have developed and demonstrated a cohesive battery of test methods for evaluation of fluorescence image quality in wide-field imagers. We also propose a number of key metrics that can facilitate direct, quantitative comparison of device performance. These methods have the potential to facilitate more uniform evaluation and inter-comparison of clinical and preclinical imaging systems than is typically achieved, with the long-term goal of establishing international standards for fluorescence image quality assessment.


Assuntos
Corantes Fluorescentes , Imagem Óptica , Fluorescência , Imagens de Fantasmas
2.
J Biomed Opt ; 21(5): 56003, 2016 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-27156717

RESUMO

With improved diagnostic capabilities and complex optical designs, endoscopic technologies are advancing. As one of the several important optical performance characteristics, geometric distortion can negatively affect size estimation and feature identification related diagnosis. Therefore, a quantitative and simple distortion evaluation method is imperative for both the endoscopic industry and the medical device regulatory agent. However, no such method is available yet. While the image correction techniques are rather mature, they heavily depend on computational power to process multidimensional image data based on complex mathematical model, i.e., difficult to understand. Some commonly used distortion evaluation methods, such as the picture height distortion (DPH) or radial distortion (DRAD), are either too simple to accurately describe the distortion or subject to the error of deriving a reference image. We developed the basic local magnification (ML) method to evaluate endoscope distortion. Based on the method, we also developed ways to calculate DPH and DRAD. The method overcomes the aforementioned limitations, has clear physical meaning in the whole field of view, and can facilitate lesion size estimation during diagnosis. Most importantly, the method can facilitate endoscopic technology to market and potentially be adopted in an international endoscope standard.


Assuntos
Endoscópios/normas , Endoscopia/métodos , Modelos Teóricos